Water Resources and Irrigation Government Departments Closing in 4 days TDR #56812151

Tender For Estimate For Repair/Renovation Of Division Office & New Construction Of 4 No. Rooms At Lehal Pwrmdc Division Office At Kothi No.3 Of Devigarh Canal Colony Patiala (Lehal Division)

Issued by Government Departments · Patiala, Punjab
Tender Value
25.15 Lakhs
Estimated cost
Bid Submission
13 Aug 2026
4 days left
EMD
50000
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Patiala → Punjab
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Estimate For Repair/Renovation Of Division Office & New Construction Of 4 No. Rooms At Lehal Pwrmdc Division Office At Kothi No.3 Of Devigarh Canal Colony Patiala (Lehal Division)

BOQ

Name of Work:- Estimate for repair/renovation of Division office & new construction of 4 No. Rooms at Lehal PWRMDC Division office at Kothi No.3 of Devigarh Canal Colony Patiala (Lehal Division)
Sl. No. Item Description
1Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish
2Earth work Excavation for pipe line in trenches and pits up to 1.5 meters depth in open area where disposal of surplus earth is done alongwith alignment, including trimming and dressing sides, levelling of beds of trenches to correct grade, cutting joint holes, refilling; consolidation and watering of refill in 15cm layers and Restoration of unmetalled or unpaved surface to its original condition excluding cost of shoring and timbering but including the cost of dewatering of rain water, diversion for traffic, night signals, providing & fixing caution boards, watching, fencing etc. Depth upto 0 to 1.5 mtr.
3Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres
4Cement concrete 1:4:8 with brick ballast 40mm gauge using mechanical mixer.
5First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth
6First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level.
7Centering & shuttering for flat surfaces such as uspended floors, roofs, landings, chajjas, shelves etc
8Damp proof course 4cm thick of cement concrete 1:2:4 with 2 coats of bitumen 20/30penetration at 1.65 Kg per sqm laid hot and sanded
9Cold twisted deformed (ribbed/ tor steel) Bars Fe 500 grade, for R.C.C. works where not included in the complete rate of R.C.C. Including bending, binding, and placing in position complete.
10Reinforced cement cocrete M-20 machanically batch mixed using Batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement, centering and shuttering in superstructure.
1112.5mm thick cement plaster with CM 1:4
12Wall painting with plastic emulsion paint of approved brand and manufacturer to give an even shade (two or more coats)
13Finishing walls with cement based water souble exterior paint such as snowcem, robbiacem etc. two or more coats to give an even shade
14Base course of floor consisting of 100mm thick cement concrete 1:8:16 and with stone aggregate 40mm gauge and 100mm sand filling using mechanical mixer for mixing of material
15Providing and laying vitrified floor tiles 600x600mm size premium quality manufactured using Double Charge Technology, with water absorption less than 0.08% and conforming to IS: 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement :4 fine sand) for new flooring laid with cement based high polymer etc., complete
16Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge.
17Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded builtup standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS :1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-InCharge. (Glazing and paneling to be paid for separately):Providing Polyester Powder coating 50 micron any coloured specified to alumnum section of various sizes including carriage of material from market to workshop & workshop to site of work. For Fixed Portion & Chaukhats
18For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour forfixing of fittings wherever required including the cost of PVC Plug / neoprene gasket required.
19Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in paneling fixed in aluminum doors, windows shutters and partition frames with C.P.brass/stainless steel screws etc. complete as per architectural drawings and directions of Engineer-In-Charge. Prelaminated particle board with decorative lamination on one side.
20Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item) Float glass panes of 5mm thickness
21Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, for doors including cost of cutting floors as required, embedding in floors and cover plates with brass pivot and single piece MS sheet outer box with slide plate and with stainless steel cover plate etc. complete as per the direction of Engineer-in-charge.
22Cost of Aluminium fittings complete for doors, windows such as tower bolts, handless and screw etc. for these fittings (Excluding sliding bolt). For shutter area above 0.50 sqm
23Wiring Light Point
24Wiring Call Bell Point
25Wiring 6A Plug Control comprising wall socket Point
26Wiring 16/20A Power PlugControl Point
27Wiring Light Point without Switch
28Wiring Light Point with DoubleControl Switches
29Wiring fan point (With fan box)
30RECESSED AIR CONDITIONER SUPPLY TERMINAL POINT (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): Wiring air conditioner supply terminal point recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 25Amp. combined/universal Socket (shuttered) and modular motor starter 25Amp. (2Module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):-Wiring AC supply terminal point having 1No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. erected at switchboard height. Wiring AC supply terminal point having 1No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. erected at switchboard height.
31Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- Overall size 1.5 sq.mm (Un-sheathed)
32Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- Overall size 4.0 sq.mm (84/0.25mm), 2Core
33Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- Overall size 2.5sq.mm (Un-sheathed)
34Supply and erection of PVC insulated PVC sheathed FR (2Core) round flexible wire with copper conductor cable (ISI marked) confirm to IS:694/1990 left bare in pipe or on surface with cleats of suitable size complete in all respect as desired by the Engineer-in-charge:- Overall size 2.5 sq.mm (50/0.25mm), 2Core
35Supply and erection of PVC insulated PVC sheathed FR (2Core) round flexible wire with copper conductor cable (ISI marked) confirm to IS:694/1990 left bare in pipe or on surface with cleats of suitable size complete in all respect as desired by the Engineer-in-charge:- Overall size 4 sq.mm (84/0.25mm), 2Core
36Supply & erection of PVC Conduit Pipes(ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- Heavy Gauge PVC Conduit Pipe 25mm dia. (On Surface)
37Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications includingconnections with suitable size of thimbles/lugs: - MCB Double Pole 6-32amp. (10kA, CurveC)
38Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitablefor 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications includingconnections with suitable size of thimbles/lugs: - MCB Single Pole 6-32amp.(10kA, Curve-C)
39Erection of Ceiling fans ( Labour rate only)
40Erection of Exhaust fan with louver shutter on the wall/ window grill
41Erection of 1X20/28/36/40W Box Type (LED/ Fluorescent) light fixture ( Labour rate only)
42CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-inCharge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge. 25mm o/d CPVC SDR 11 Pipe & Fitting 20mm O/D
43CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-inCharge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge. 25mm o/d CPVC SDR 11 Pipe & Fitting 25mm O/D
44CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-inCharge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge. 32mm o/d
45Providing & Fixing and jointing brass ball valves screwed with Ss/BRASS ball & spindle & teflon seats on GI pipelines including carriages complete Ball Valve 20mm dia
46Providing & Fixing and jointing brass ball valves screwed with Ss/BRASS ball & spindle & teflon seats on GI pipelines including carriages complete Ball Valve 25 mm dia
47Providing & Fixing and jointing brass ball valves screwed with Ss/BRASS ball & spindle & teflon seats on GI pipelines including carriages complete Ball Valve 32 mm dia
48Providing, fixing and jointing G.I Union Couplings(of approved make with the approval EIC) as per IS 1879 in G.I. Pipe lines complete in all respect 20 mm dia
49Providing, fixing and jointing G.I Union Couplings(of approved make with the approval EIC) as per IS 1879 in G.I. Pipe lines complete inall respect 25 mm dia
50Providing, fixing and jointing G.I Union Couplings (of approved make with the approval EIC) as per IS 1879 in G.I. Pipe lines complete in all respect 32 mm dia
51Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes lines and making good the same to its original condition.
52Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chambercover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design IC 600mmx900mm
53Making connection with existing GI brach main upto 40mm size pipe including cutting of existing pipeline,threading of pipelines from both ends and fixing of GI tee etc in pipeline (including cost of GI tee)
54Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1cement: 2 coarse sand :4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:2 (1cement : 2 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete. pipes 100 to 250 mm dia
55Providing and fixing in position vitreous china ware white lavatory suites of approved make (to theapproval of Engineer-in-charge) consistingof C.P. brass waste 32mm dia with one C.P. brass pillar tap including Rack Bolt Screw Pair 115mm long complete in all respect. Size 630 mm x 450 mm x 830 mm
56Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect 32mm dia
57Providing and fixing in position Chinaware Floor Mounted One Piece EWC type with matching chinaware cistern 10 ltr. Capacity. (without cistern fitting) with P trap or S trap of approved make (to the approval of the Engineer-in-charge) and seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge.Chinaware Floor Mounted One Piece EWC rim less type with matching chinaware cistern 10 ltr.Capacity. (without cistern fitting) size 69x36x74 cm with P trap or S trap and seat cover complete in all respect.
58Providing and fixing jet spray with 2'-6\\" long PVC pipe. With C.P. Brass nut
59Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on top complete in all respect (as required by the Engineer-in- Charge)Size 1500mmx600mm or any other size
60Providing and fixing in position premium range C.P. Brass Fittings and accessories of approved make (to the approval of Engineer-incharge ) complete in all respect.C.P. Brass fittings:C.P.brass 15mmAngular stop cock with Wall flange
61Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect PVC tube connection of size 15 mm x 450 mm with C.P. Brass nut
62Providing & Fixing in position C.P. Brass flange Dome of approved make (to the approval of Engineer -in-charge ) under various fixtures complete in all respect.
63Providing and fixing in position premium range C.P. Brass Fittings and accessories of approved make (to the approval of Engineer-incharge ) complete in all respect.C.P. Brass fittings:C.P. brass 15mmConcealed stop cock with adjustable wall flange with seal.(Outer +Inner Body)
64Providing and fixing in position SS Grating with frame of approved make (to the approval of engineer incharge) complete in all respects.
65Providing and fixing in position premium range C.P.Brass Fittings and accessories of approved make (to the approval of Engineer-incharge ) complete in all respect.C.P. Brass Accessories:C.P. brass towelrack 600mm long with lower hangers
66Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect.
67Providing & Fixing in position C.P. Brass extension piece 25mm long to 100mm long of approved make (to the approval of Engineer-incharge )with various fixtures complete in all respect.C.P. Brass extension piece, 25mm long to 50mm long
68Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mmx 150mm, cover and frame clearopening 300mm x300mm and out of side size330mm x 330mm and chamber including cost of allbricks work in cement morter1:5 cement concrete 1:2:4 incoping around cover andframe etc. as per standarddesign minimum depth of water should be 150 mm witha minimum seal 50mm.100mm internal DiametreH.C.I. gully trap with H.C.I.grating and cast iron coverweighing approximately 7.26kg. and frame clear opening 300mm x 300mm and out ofside size 330mm x 330mm
69Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining.For 110mm o/d pipes P Trap/Floor Trap 110mm x 110mm
70Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of for inlet, outlet and over flo pipes but without fittings and base support for tank. Tripple layer tank approved make (to the approval of Engineer -incharge) with cover with suitable locking arrangement and making Necessary holes for inlet, outlet and over flow pipes but without fittings and base support for tank. Tripple layer tank
71Providing & fixing in position on terrace (at all floor levels) HDPE tank cover for water storage tanks of approved make (to the approval of Engineer -in-charge) complete in all respect.
72Providing and fixing in position G.I. Tank Nipple of approved make (to the approval of Engineer-incharge) in PVC Water storage tanks complete in all respect.
73Providing and fixing in position automatic brass Ball Cock in tanks. Plastic Ball Cock with rod and Plastic Ball 25mm dia
74Providing and fixing in position C.P. Acrylic shelf with C.P.bracket and guard rails of approved make (to the approval of Engineer-incharge ) fixed in with rawl plugs and C.P brass screws complete in all respect. C.P. brass Glass Corner with rail 8 mm thickness and height 250 mm
75Providing & fixing in position single socket SWR UPVC soil waste pipes incl. cutting ,jointing, wastagetype-B 110mm o/d SWR UPVC pipes laid complete in all respect
76Water proofing treatment of Roof Slab with High performance cementitious two component product, consisting of a powder component and an acrylic polymer using two coats ( Dr Fixit Roofseal flex -Packaging Size: 12 .5 kg (7.5 kg powder + 5 kg polymer) / equivalent water proofing Solution ). The slurry thus formed by mixing the two, is to be applied on new roofs to forms a seamless, highly elastic, non-toxic waterproofing layer on the roof with a life expectancy of 7 years. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge.
77Providing ceiling Fan
78Providing LED Tube light of 36W
79Providing LED Bulb of 20W
80Providing Exaust Fan 300 mm
81Providing and fixing ( PPGL) precoated painted galvalume sheet roofing (size, shape and 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost ofpurlins, rafters and trusses and including cutting to size and shape wherever required 0.50 mm (+ 0.05 %) thick pitch of corrugation as approved by Engineer-in-charge) The end rib shall have anti cappillarygroove and return leg. The steel sheet must be having yield strength of 550 MPa ( Fy= 550 MPa) metallic coated with Zinc- Aluminium alloy ( i.e. 55% Al,43.4%Zinc, 1.6% Si-Zincalume) AZ150 ( Min. 150 bm/mm2 total on both sides), pre painted with super Durable Polyster XRW quality paint includes inorganic infrared reflective pigment. The sheet confirms to general requirement of AS/NZS 2728 type 4/ IS 15965 class 3 durability and gloss value of 25%-40%. should be supplied in single length upto 12 metre or as desired by Engineer-in charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x
82Providing and fixing Gutter 250mm wide with PPGL 0.50 thick (TCT) manufactured from zinc / aluminium alloy coated high tensile steel, having minimum yield strength of 550 MPa of approved colour fixed by means of self-drilling screws limped washers as per the manufactures guidelines complete in all respect and to the entire satisfaction of engineer in charge.
83Providing and fixing polycarbonate sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws with EPDM seal, and the joints shall be provided with aluminium strips at top and bottom as a seal complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required ,Pollycarbonate sheet 2mm thick solid type
84Structural steel work in angles, tees, flats, riveted, including cutting, fixing all gusset plates, bolts, nuts, rivets etc.with hoisting and erecting in position.For roof truss,wellcurbs,plategirders etc. of any span forbuilding for bridges upto 15M span
85Applying priming coat with metal primer on new steel or iron work including preparation of surface
86Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade
87Providing and fixing Heat Resistant Terrace Tiles (300mm x 300 mm x 20 mm) with SRI (solar refractive index) >78, solar reflection > 0.70 andinitial emittance > 0.75 onwaterproof and sloped surfaceof terrace, laid on 20 mmthick cement sand mortar inthe ratio of 1:4 (1 cement : 4coarse sand) and grouting the joints with mix of white cement & marble powder inratio of 1:1, including rubbingand polishing of the surface upto 3 cuts complete,including providing skirtingupto 150 mm height along theparapet walls in the same manner.
88Providing and fixing 110 mm dia . U.P.V.C Rain water pipeof 4 kgf./sqm as per IS:4985 including jointing during masonary complete as per specifications and to theentire satisfaction of Engineer-in- charge.
89Providing and fixing 110 mm dia. U.P.V.C bend for Rainwater pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineerin- charge.
90scraping (c) cement plaster
9112.5 mm thick cement plaster 1:4
92Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S.clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerin- charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding.
93Water proofing treatment ofRoof Slab with High performance cementitious twocomponent product, consistingof a powder component andan acrylic polymer using twocoats ( Dr Fixit Roofseal flex -Packaging Size: 12 .5 kg (7.5kg powder + 5 kg polymer) /equivalent water proofing Solution ). The slurry thusformed by mixing the two, isto be applied on new roofs toforms a seamless, highlyelastic, non-toxic waterproofing layer on theroof with a life expectancy of 7 years. The work shall becarried out all complete as per specification and the directionof the Engineer-in-charge
94Distempering with dry distemper of approved manufacture two or more coats over one priming coat togive an even shade
95Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish
96Finishing walls with cement based water soluble exterior paint such as snowcem, robbiacem etc. two or more coats to give an even shade
97Painting two or more coats with synthetic enamel paints in all shades on old wood work or metallic or plastered or concrete surface to give an even shade including rubbing down old paint Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56812151
AUTHORITY Government Departments
TENDER VALUE 25.15 Lakhs
LAST DATE 13-08-2026
Authority
Authority Name Punjab Water Resources Management And Development Corporation Limited
Work Description Tender for Estimate For Repair/Renovation Of Division Office & New Construction Of 4 No. Rooms At Lehal Pwrmdc Division Office At Kothi No.3 Of Devigarh Canal Colony Patiala (Lehal Division)
Basic Detail
Tender No Nit 15/2026
Bidding Type Tender
Location
City Patiala
State Punjab
Key Dates
Publish Date 03 Aug 2026
Submission Date 13 Aug 2026
Open Date 13 Aug 2026
Finance
Tender Value 25.15 Lakhs
Tender Fee 590
EMD 50000
Exemption Not Available
Document List
51452a8f-e8fe-4ce4-ad1c-a9673224afb3.html
BOQ_352005.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 13, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Aug 13, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 4 days