Health and Family Welfare Boards / Undertakings / PSU Closing in 20 days TDR #56811900

Bids Are invited for Ultrasonic Gastrovideoscope - Should Have An Electronic Curved Linear Array Transducer With High Resolution Ccd Which Delivers Higher Quality Ultrasound Image With Greater Imaging Depth. , Should Offer Flexibility From Straighfor

Issued by Boards / Undertakings / PSU · Mumbai, Maharashtra
Tender Value
Ref. Documents
Estimated cost
Bid Submission
24 Aug 2026
20 days left
EMD
92000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Mumbai → Maharashtra
EMD Exemption
Available
Quantity
1

Project Description

Bids Are invited for Ultrasonic Gastrovideoscope - Should Have An Electronic Curved Linear Array Transducer With High Resolution Ccd Which Delivers Higher Quality Ultrasound Image With Greater Imaging Depth. , Should Offer Flexibility From Straighforward Tissue S Ling To Sophisticated Eus Guided Treatment. , Scanning Range Should Be 180° Or More. , Should Have Lens Cleaning Function For Keeping The Endoscopic Field Of View Clear All The Times. , Angulation Should Be Up- 130°/Down-90°, Left-90°/Right- 90° Or More. , Should Have Eus Images With Selectable Frequencies From 5 To 12 Mhz. , Should Operate For B Mode, Color Doppler Mode And Power Doppler Mode For Effective Confirmation Of Blood Flow. , Field Of View Should Be 100 Degree Or More. , Depth Of Field Should Be 3 To 100 Mm Or More. , Direction Of View Should Be Forward Oblique Viewing 55° Or More. , Insertion Tube Outer Diameter - 12.6 Mm Or Less. , Distal End Outer Diameter - 14.6 Mm Or Less. , Instrument Channel Diameter - 3.7 Mm Or More. , Videoscope Should Have Fna (Therapeutic) Capability. , Eus Scope Should Be Fully Immersible For Thorough Cleaning. , Balloon Inflation & Deflation Must Be Controlled From Air/Water & Suction Button. , Should Be Compatible With Existing Endoscopy Processor- Cv 1500, Cv 190 As Well As Ultrasound Processor- Eu Me3, Eu Me2. , Should Provide Dvi,Hd-Sdi Connecting Cables, -1 Each. , Ultrasound Cable (Cat No.Maj 2056) Should Be Provided Along With The Scope To Ensure Excellent Platform Compatibility. , Should Provide Connecting Cable Kit (Cat No. Maj 2477) For Connecting Existing Cv-1500,Cv-190 Processor. , Should Be Provide Co2 Bottle Container (Cat No. Maj 902) For Connecting Existing Cv-1500,Cv-190 Processor -2Nos , Should Provide Video Scope Cable (Cat No. Maj1430) Qty-01 For Connecting 180 Series Scope To Cv190 & Cv1500 Video Processor. , Should Be Supplied With All The Standard Accessories Such As Mouth Piece, Channel Plug, Injection Tube, Balloon, Channel Cleaning Brush, Balloon Applicator, Suction Cleaning Adaptor, Cleaning Adaptor For Instrument Channel, Water Resistant Cap For Both Ends Of Processor End, Eus Scope Suction Valve,Eus Scope Air Water Valve,Biopsy Valve. , Should Be Supplied With Additional Accessories Such As , Should Perform Preventive Maintenance (2Nos) During Warranty,Amc,Cmc & If Entered Into Amc(Includes Unlimited Breakdown Calls) /Cmc (Which Will Include Spare Replacement, Breakdown Calls). Vendor To Submit Sops For Pms At The Time Of Installation/ Commissioning. This Is Mandatory Requirement. , Performance Certificates Of Iq,Oq,Pq Tests To Be Submitted At The Time Of Installation/Commissioning. , Vendor To Submit The Technical Data Sheet, Brochure Etc As A Tender Document With Reference To The Quoted Make & Model. Please Mention The Reference Page No., Quoted Model Name/Number Against Each Item Etc In These Documents Against Each Technical Specifications In The Compliance. , Vendor To Submit List Of Consumables/Consumable Spares And Spare Parts( I.E.Spares Need To Be Replaced At Regular Intervals, Maybe Quarterly/Half Yearly/Yearly Etc.) If Any.Cost Of Consumables To Be Added In The Financial Bid Not In The Technical Bid. , Vendor To Submit Details Of Footprint Size & Weight Of The Quoted Model. , Vendor To Submit Power Consumption. , Demo Of The Quoted Model , Will Be Required If So Desired By The User, After The Opening Of The Technical Bid And Prior To Opening Of Financial Bid. This Is For Technical Evaluation. All Technical Specifications Mentioned Above To Be Mandatorily Shown In The Demo Unit. , Users/Installation List: A List Of Installations Of The Quoted Model With The Address And Contact Numbers To Be Provided. , Predispatch Inspection At Factory Will Be Required If Desired By Authorities. , Should Be Ce/Us Fda/Bis/Icmed Approved. , Vendor Should Provide The User Manual And Service Manual Copy During The Installation Of The Equipment. , Unpacking And Shifting The Consignment To The Installation Site Is To Be Included In The Vendors Scope Of Supply. Bidder/Manufacturer/Authorized Service Provider Should Take Responsibility To Lift /Shift The Consignment From Unloading Site To The Installation Site. Unloading Site Shall Be Stores Department, Tmh Parel. If Needed ,Bidder Has To Arrange For The Labours At No Charge To Tmh Parel. (Before Submitting The Quotation,Bidders May Visit Tmh Parel. To Know Unloading And Installation Site. , Training: , Local Service Support: Should Have Local Office And Service Support/Service Engineer For Attending The Breakdown Calls. Details To Be Submitted. , Response Time: Should Not Be More Than 06 Hrs From Lodging A Breakdown Complaint On Toll Free Or By Email. , Warranty- 2 Years , Cmc- For 8 Years Per Annum After Warranty , Include 2 Preventive Maintenance/ Year And All Breakdown Visits. All Bought Out Items Used In System Should Also Be Included In The Warranty & Cmc. Warranty & Cmc Should Include Upgrades / Update Cost, No Separate Software Licence Fees Will Be Payable. Standby Scope To Be Provided Against Defective Scope. , Please Note : Warranty & Cmc Should Cover Unlimited Breakdowns,Free Spare Replacements, Patinet Bites, Any Type Leakage In The Flexible Scope , Glass Part Breakages , Ccd Damage And Other Regular Problems Observed Such As Flickring,Angulation, Etc. , Loaner Should Be Provided During Warranty And Cmc. , Back To Back Assurance To Be Taken By The Supplier From Oem To Supply Spares For Minimum 10 Years And To Be Submitted. , If 2 Years Warranty, Cmc Per Annum For 8 Years After Warranty And Buyback If Any Wherever Applicable Are Not Adhered To, Tmc Reserves Right To Reject The Offer. , Please Mention Whether Ups Is Required For The Equipment. If So Should Be Included In The Offer. , Only Yes Or No Should Be Mentioned In Compliance Report And Additional Information In Remarks Column. , Please Provide List Of The Consumables/Spares/Reagents/Control/Calibrators (If Any) In Technical Documents And Cost Of The Same Should Be Uploaded In Pdf File In The Financial Documents. , Do Not Mention / Upload Price And Cost In The Technical Documents Otherwise Your Quotation Will Be Disqualified At Technical Stage.

BOQ

Sl. No. Item TitleItem Description
1Should have an electronic curved linear array transducer with High resolution CCD which delivers higher quality ultrasound image with greater imaging depth.Should have an electronic curved linear array transducer with High resolution CCD which delivers higher quality ultrasound image with greater imaging depth.
2Should offer flexibility from straighforward tissue sampling to sophisticated EUS guided treatment.Should offer flexibility from straighforward tissue sampling to sophisticated EUS guided treatment.
3Scanning range should be 180° or more.Scanning range should be 180° or more.
4Should have lens cleaning function for keeping the endoscopic field of view clear all the times.Should have lens cleaning function for keeping the endoscopic field of view clear all the times.
5Angulation should be Up- 130°/Down-90°, Left-90°/Right- 90° Or more.Angulation should be Up- 130°/Down-90°, Left-90°/Right- 90° Or more.
6Should have EUS images with selectable frequencies from 5 to 12 MHz.Should have EUS images with selectable frequencies from 5 to 12 MHz.
7Should operate for B mode, Color doppler mode and power doppler mode for effective confirmation of blood flow.Should operate for B mode, Color doppler mode and power doppler mode for effective confirmation of blood flow.
8Field of view should be 100 degree or more.Field of view should be 100 degree or more.
9Depth of field should be 3 to 100 mm or more.Depth of field should be 3 to 100 mm or more.
10Direction of view should be forward oblique viewing 55° or more.Direction of view should be forward oblique viewing 55° or more.
11Insertion tube outer diameter - 12.6 mm or less.Insertion tube outer diameter - 12.6 mm or less.
12Distal end outer diameter - 14.6 mm or less.Distal end outer diameter - 14.6 mm or less.
13Instrument channel diameter - 3.7 mm or more.Instrument channel diameter - 3.7 mm or more.
14Videoscope should have FNA (therapeutic) capability.Videoscope should have FNA (therapeutic) capability.
15EUS Scope should be fully immersible for thorough cleaning.EUS Scope should be fully immersible for thorough cleaning.
16Balloon inflation & deflation must be controlled from Air/water & suction button.Balloon inflation & deflation must be controlled from Air/water & suction button.
17Should be compatible with existing endoscopy processor- CV 1500, CV 190 as well as ultrasound Processor- EU ME3, EU ME2.Should be compatible with existing endoscopy processor- CV 1500, CV 190 as well as ultrasound Processor- EU ME3, EU ME2.
18Should provide DVI,HD-SDI connecting cables, -1 each.Should provide DVI,HD-SDI connecting cables, -1 each.
19Ultrasound cable (cat no.MAJ 2056) should be provided along with the scope to ensure excellent platform compatibility.Ultrasound cable (cat no.MAJ 2056) should be provided along with the scope to ensure excellent platform compatibility.
20Should provide connecting cable kit (Cat no. MAJ 2477) for connecting existing CV-1500,CV-190 Processor.Should provide connecting cable kit (Cat no. MAJ 2477) for connecting existing CV-1500,CV-190 Processor.
21Should be provide CO2 bottle container (Cat no. MAJ 902) for connecting existing CV-1500,CV-190 Processor -2nosShould be provide CO2 bottle container (Cat no. MAJ 902) for connecting existing CV-1500,CV-190 Processor -2nos
22Should provide video scope cable (Cat no. MAJ1430) Qty-01 for connecting 180 series scope to CV190 & CV1500 video processor.Should provide video scope cable (Cat no. MAJ1430) Qty-01 for connecting 180 series scope to CV190 & CV1500 video processor.
23Should be supplied with all the standard accessories such as mouth piece, channel plug, injection tube, balloon, channel cleaning brush, balloon applicator, suction cleaning adaptor, cleaning adaptor for instrument channel, water resistant cap for both ends of processor end, EUS scope suction valve,EUS scope Air water valve,biopsy valve.Should be supplied with all the standard accessories such as mouth piece, channel plug, injection tube, balloon, channel cleaning brush, balloon applicator, suction cleaning adaptor, cleaning adaptor for instrument channel, water resistant cap for both ends of processor end, EUS scope suction valve,EUS scope Air water valve,biopsy valve.
24Should be supplied with additional accessories such asShould be supplied with additional accessories such as
25Should perform preventive maintenance (2nos) during warranty,AMC,CMC & if entered into AMC(includes unlimited breakdown calls) /CMC (which will include spare replacement, breakdown calls). Vendor to submit SOPs for PMS at the time of installation/ commissioning. This is mandatory requirement.Should perform preventive maintenance (2nos) during warranty,AMC,CMC & if entered into AMC(includes unlimited breakdown calls) /CMC (which will include spare replacement, breakdown calls). Vendor to submit SOPs for PMS at the time of installation/ commissioning. This is mandatory requirement.
26Performance certificates of IQ,OQ,PQ tests to be submitted at the time of installation/commissioning.Performance certificates of IQ,OQ,PQ tests to be submitted at the time of installation/commissioning.
27Vendor to submit the technical data sheet, brochure etc as a tender document with reference to the quoted make & model. Please mention the reference page no., quoted model name/number against each item etc in these documents against each technical specifications in the compliance.Vendor to submit the technical data sheet, brochure etc as a tender document with reference to the quoted make & model. Please mention the reference page no., quoted model name/number against each item etc in these documents against each technical specifications in the compliance.
28Vendor to submit list of consumables/consumable Spares and spare parts( i.e.spares need to be replaced at regular intervals, maybe quarterly/half yearly/yearly etc.) if any.Cost of consumables to be added in the financial bid not in the technical bid.Vendor to submit list of consumables/consumable Spares and spare parts( i.e.spares need to be replaced at regular intervals, maybe quarterly/half yearly/yearly etc.) if any.Cost of consumables to be added in the financial bid not in the technical bid.
29Vendor to submit details of footprint size & weight of the quoted model.Vendor to submit details of footprint size & weight of the quoted model.
30Vendor to submit power consumption.Vendor to submit power consumption.
31Demo of the quoted model , will be required if so desired by the user, after the opening of the technical bid and prior to opening of financial bid. This is for technical evaluation. All technical specifications mentioned above to be mandatorily shown in the demo unit.Demo of the quoted model , will be required if so desired by the user, after the opening of the technical bid and prior to opening of financial bid. This is for technical evaluation. All technical specifications mentioned above to be mandatorily shown in the demo unit.
32User's/Installation list: A list of installations of the quoted model with the address and contact numbers to be provided.User's/Installation list: A list of installations of the quoted model with the address and contact numbers to be provided.
33Predispatch inspection at factory will be required if desired by authorities.Predispatch inspection at factory will be required if desired by authorities.
34Should be CE/US FDA/BIS/ICMED approved.Should be CE/US FDA/BIS/ICMED approved.
35Vendor should provide the User manual and service manual copy during the installation of the equipment.Vendor should provide the User manual and service manual copy during the installation of the equipment.
36Unpacking and shifting the consignment to the installation site is to be included in the vendor's scope of supply. Bidder/manufacturer/authorized service provider should take responsibility to lift /shift the consignment from unloading site to the installation site. Unloading site shall be Stores department, TMH Parel. If needed ,bidder has to arrange for the labours at no charge to TMH Parel. (Before submitting the quotation,bidders may visit TMH Parel. to know unloading and installation site.Unpacking and shifting the consignment to the installation site is to be included in the vendor's scope of supply. Bidder/manufacturer/authorized service provider should take responsibility to lift /shift the consignment from unloading site to the installation site. Unloading site shall be Stores department, TMH Parel. If needed ,bidder has to arrange for the labours at no charge to TMH Parel. (Before submitting the quotation,bidders may visit TMH Parel. to know unloading and installation site.
37Training:Training:
38Local Service Support: Should have local office and service support/service engineer for attending the breakdown calls. Details to be submitted.Local Service Support: Should have local office and service support/service engineer for attending the breakdown calls. Details to be submitted.
39Response Time: Should not be more than 06 hrs from lodging a breakdown complaint on toll free or by email.Response Time: Should not be more than 06 hrs from lodging a breakdown complaint on toll free or by email.
40Warranty- 2 yearsWarranty- 2 years
41CMC- For 8 years per annum after warrantyCMC- For 8 years per annum after warranty
42Include 2 preventive maintenance/ year and all breakdown visits. All bought out items used in system should also be included in the warranty & CMC. Warranty & CMC should include upgrades / update cost, No separate software licence fees will be payable. Standby scope to be provided against defective scope.Include 2 preventive maintenance/ year and all breakdown visits. All bought out items used in system should also be included in the warranty & CMC. Warranty & CMC should include upgrades / update cost, No separate software licence fees will be payable. Standby scope to be provided against defective scope.
43Please note : Warranty & CMC should cover unlimited breakdowns,free spare replacements, patinet bites, any type leakage in the flexible scope , glass part breakages , CCD damage and other regular problems observed such as flickring,angulation, etc.Please note : Warranty & CMC should cover unlimited breakdowns,free spare replacements, patinet bites, any type leakage in the flexible scope , glass part breakages , CCD damage and other regular problems observed such as flickring,angulation, etc.
44Loaner should be provided during Warranty and CMC.Loaner should be provided during Warranty and CMC.
45Back to back assurance to be taken by the supplier from OEM to supply spares for minimum 10 years and to be submitted.Back to back assurance to be taken by the supplier from OEM to supply spares for minimum 10 years and to be submitted.
46If 2 years warranty, CMC per annum for 8 years after warranty and Buyback if any wherever applicable are not adhered to, TMC reserves right to reject the offer.If 2 years warranty, CMC per annum for 8 years after warranty and Buyback if any wherever applicable are not adhered to, TMC reserves right to reject the offer.
47Please mention whether UPS is required for the equipment. If so should be included in the offer.Please mention whether UPS is required for the equipment. If so should be included in the offer.
48Only Yes or No should be mentioned in compliance report and additional information in remarks column.Only Yes or No should be mentioned in compliance report and additional information in remarks column.
49Please provide list of the Consumables/Spares/Reagents/Control/Calibrators (if any) in Technical Documents and cost of the same should be uploaded in PDF file in the Financial Documents.Please provide list of the Consumables/Spares/Reagents/Control/Calibrators (if any) in Technical Documents and cost of the same should be uploaded in PDF file in the Financial Documents.
50Do not mention / upload price and cost in the technical documents otherwise your quotation will be disqualified at technical stage.Do not mention / upload price and cost in the technical documents otherwise your quotation will be disqualified at technical stage.

AI Tender Summary

OUR REF NO 56811900
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 24-08-2026
Authority
Authority Name Tata Memorial Centre
Work Description Bids Are invited for Ultrasonic Gastrovideoscope - Should Have An Electronic Curved Linear Array Transducer With High Resolution Ccd Which Delivers Higher Quality Ultrasound Image With Greater Imaging Depth. , Should Offer Flexibility From Straighforward Tissue S Ling To Sophisticated Eus Guided Treatment. , Scanning Range Should Be 180° Or More. , Should Have Lens Cleaning Function For Keeping The Endoscopic Field Of View Clear All The Times. , Angulation Should Be Up- 130°/Down-90°, Left-90°/Right- 90° Or More. , Should Have Eus Images With Selectable Frequencies From 5 To 12 Mhz. , Should Operate For B Mode, Color Doppler Mode And Power Doppler Mode For Effective Confirmation Of Blood Flow. , Field Of View Should Be 100 Degree Or More. , Depth Of Field Should Be 3 To 100 Mm Or More. , Direction Of View Should Be Forward Oblique Viewing 55° Or More. , Insertion Tube Outer Diameter - 12.6 Mm Or Less. , Distal End Outer Diameter - 14.6 Mm Or Less. , Instrument Channel Diameter - 3.7 Mm Or More. , Videoscope Should Have Fna (Therapeutic) Capability. , Eus Scope Should Be Fully Immersible For Thorough Cleaning. , Balloon Inflation & Deflation Must Be Controlled From Air/Water & Suction Button. , Should Be Compatible With Existing Endoscopy Processor- Cv 1500, Cv 190 As Well As Ultrasound Processor- Eu Me3, Eu Me2. , Should Provide Dvi,Hd-Sdi Connecting Cables, -1 Each. , Ultrasound Cable (Cat No.Maj 2056) Should Be Provided Along With The Scope To Ensure Excellent Platform Compatibility. , Should Provide Connecting Cable Kit (Cat No. Maj 2477) For Connecting Existing Cv-1500,Cv-190 Processor. , Should Be Provide Co2 Bottle Container (Cat No. Maj 902) For Connecting Existing Cv-1500,Cv-190 Processor -2Nos , Should Provide Video Scope Cable (Cat No. Maj1430) Qty-01 For Connecting 180 Series Scope To Cv190 & Cv1500 Video Processor. , Should Be Supplied With All The Standard Accessories Such As Mouth Piece, Channel Plug, Injection Tube, Balloon, Channel Cleaning Brush, Balloon Applicator, Suction Cleaning Adaptor, Cleaning Adaptor For Instrument Channel, Water Resistant Cap For Both Ends Of Processor End, Eus Scope Suction Valve,Eus Scope Air Water Valve,Biopsy Valve. , Should Be Supplied With Additional Accessories Such As , Should Perform Preventive Maintenance (2Nos) During Warranty,Amc,Cmc & If Entered Into Amc(Includes Unlimited Breakdown Calls) /Cmc (Which Will Include Spare Replacement, Breakdown Calls). Vendor To Submit Sops For Pms At The Time Of Installation/ Commissioning. This Is Mandatory Requirement. , Performance Certificates Of Iq,Oq,Pq Tests To Be Submitted At The Time Of Installation/Commissioning. , Vendor To Submit The Technical Data Sheet, Brochure Etc As A Tender Document With Reference To The Quoted Make & Model. Please Mention The Reference Page No., Quoted Model Name/Number Against Each Item Etc In These Documents Against Each Technical Specifications In The Compliance. , Vendor To Submit List Of Consumables/Consumable Spares And Spare Parts( I.E.Spares Need To Be Replaced At Regular Intervals, Maybe Quarterly/Half Yearly/Yearly Etc.) If Any.Cost Of Consumables To Be Added In The Financial Bid Not In The Technical Bid. , Vendor To Submit Details Of Footprint Size & Weight Of The Quoted Model. , Vendor To Submit Power Consumption. , Demo Of The Quoted Model , Will Be Required If So Desired By The User, After The Opening Of The Technical Bid And Prior To Opening Of Financial Bid. This Is For Technical Evaluation. All Technical Specifications Mentioned Above To Be Mandatorily Shown In The Demo Unit. , Users/Installation List: A List Of Installations Of The Quoted Model With The Address And Contact Numbers To Be Provided. , Predispatch Inspection At Factory Will Be Required If Desired By Authorities. , Should Be Ce/Us Fda/Bis/Icmed Approved. , Vendor Should Provide The User Manual And Service Manual Copy During The Installation Of The Equipment. , Unpacking And Shifting The Consignment To The Installation Site Is To Be Included In The Vendors Scope Of Supply. Bidder/Manufacturer/Authorized Service Provider Should Take Responsibility To Lift /Shift The Consignment From Unloading Site To The Installation Site. Unloading Site Shall Be Stores Department, Tmh Parel. If Needed ,Bidder Has To Arrange For The Labours At No Charge To Tmh Parel. (Before Submitting The Quotation,Bidders May Visit Tmh Parel. To Know Unloading And Installation Site. , Training: , Local Service Support: Should Have Local Office And Service Support/Service Engineer For Attending The Breakdown Calls. Details To Be Submitted. , Response Time: Should Not Be More Than 06 Hrs From Lodging A Breakdown Complaint On Toll Free Or By Email. , Warranty- 2 Years , Cmc- For 8 Years Per Annum After Warranty , Include 2 Preventive Maintenance/ Year And All Breakdown Visits. All Bought Out Items Used In System Should Also Be Included In The Warranty & Cmc. Warranty & Cmc Should Include Upgrades / Update Cost, No Separate Software Licence Fees Will Be Payable. Standby Scope To Be Provided Against Defective Scope. , Please Note : Warranty & Cmc Should Cover Unlimited Breakdowns,Free Spare Replacements, Patinet Bites, Any Type Leakage In The Flexible Scope , Glass Part Breakages , Ccd Damage And Other Regular Problems Observed Such As Flickring,Angulation, Etc. , Loaner Should Be Provided During Warranty And Cmc. , Back To Back Assurance To Be Taken By The Supplier From Oem To Supply Spares For Minimum 10 Years And To Be Submitted. , If 2 Years Warranty, Cmc Per Annum For 8 Years After Warranty And Buyback If Any Wherever Applicable Are Not Adhered To, Tmc Reserves Right To Reject The Offer. , Please Mention Whether Ups Is Required For The Equipment. If So Should Be Included In The Offer. , Only Yes Or No Should Be Mentioned In Compliance Report And Additional Information In Remarks Column. , Please Provide List Of The Consumables/Spares/Reagents/Control/Calibrators (If Any) In Technical Documents And Cost Of The Same Should Be Uploaded In Pdf File In The Financial Documents. , Do Not Mention / Upload Price And Cost In The Technical Documents Otherwise Your Quotation Will Be Disqualified At Technical Stage.
Basic Detail
Tender No GEM/2026/B/7861180
Bidding Type Tender
Location
City Mumbai
State Maharashtra
Key Dates
Publish Date 03 Aug 2026
Submission Date 24 Aug 2026
Open Date 24 Aug 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 92000
Exemption Available
Document List
3156fcc9-aa70-4b1f-ba61-643f2d6a84eb.pdf
1785496622.xlsx
AFFIDAVIT_15f28a83-29bd-4941-afb91785498057638_joshineha.pdf
ultrasonic_gastrovideoscope_2026-07-31-14-56-47_a1ec94c1db43a4bf565ab684acabe377.xlsx

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 24, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 20 days
Aug 24, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 20 days

Tender Documents

Download All (ZIP) ↓
pdf

3156fcc9-aa70-4b1f-ba61-643f2d6a84eb.pdf

xlsx

1785496622.xlsx

pdf

AFFIDAVIT_15f28a83-29bd-4941-afb91785498057638_joshineha.pdf

xlsx

ultrasonic_gastrovideoscope_2026-07-31-14-56-47_a1ec94c1db43a4bf565ab684acabe377.xlsx

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders