Communications and Information Technology Government Departments Closing in 6 days TDR #56811510

Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Repair And Maintenance Of Mv Electrical Installation At Te Bts Under Bhubaneswar Ba; Electrical System Or Installation; Service Provider - Attending

Issued by Government Departments · Khordha, Odisha
Tender Value
19.40 Lakhs
Estimated cost
Bid Submission
14 Aug 2026
6 days left
EMD
38808
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Khordha → Odisha
EMD Exemption
Not Available
Quantity
1

Project Description

Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Repair And Maintenance Of Mv Electrical Installation At Te Bts Under Bhubaneswar Ba; Electrical System Or Installation; Service Provider - Attending Electrical Faults Of Lt/Mv Electrical System Comprising Of Lt/Mv Service Connection Line, Feeder Panel, Main Distribution Panel, Mcb Dbs, Riser Mains Etc. On Need Basis By Deputing Qualified And Trained/Skilled Technician Having Valid Electrical License Of Appropriate Voltage And Making Arrangements For Checking, Testing With Suitable Testing Devices, Fault Finding, Replacing Faulty Mcbs/Isolators/Switches/L S/Holders Etc. By New Ones (Cost Of Materials Are Not Included In The Scope Of This Item And Will Be Paid Separately) And Restoration Of The Power Supply To The Telephone Exchange/Admin Bldg/Bts/Staff Quarters Complex Etc. Complete As Required. , Sites Within A Distance Of ≤15 Kms From Ba Hq , Sites Within A Distance Of >15 Kms And ≤ 50Kms From Ba Hq , Sites Within A Distance Of >50 Kms And ≤ 100Kms From Ba Hq , Sites Within A Distance Of >100 Kms And ≤ 150Kms From Ba Hq , Sites Within A Distance Of >150 Kms And ≤ 200Kms From Ba Hq , Supplying And Fixing 6A To 32 A Rating, 240/415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. (Make-Legrand/L&T/Siemens/Schneider) , Single Pole , Double Pole , Supplying And Fixing Following Rating, Double Pole, 240 V, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. , 40 A , 63 A , Supplying And Fixing Following Rating, Four Pole, 415 V, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. (Make-Legrand/L&T/Siemens/Schneider) , 63 A , 100 A , Replacement Of The Faulty And Burn Out Hrc Fuse Links And Porcelain Fuse Units (Fuse Carrier And Base) By New Ones Of Following Ratings I/C Connection Testing Etc. As Required. (Make-Legrand / L&T / Schneider Electric / Siemens/Havells) , 32 S 415V Hrc Fuse Links- Cylindrical Type (L&T/Havells) , 63 S 415V Hrc Fuse Links- Cylindrical Type (L&T/Havells) , 32 S 415V Hrc Fuse Links-Bolted Type (L&T/Havells) , 63 S 415V Hrc Fuse Links- Bolted Type (L&T/Havells) , 100 S 415V Hrc Fuse Links- Din Type (L&T/Havells) , 63 S 415V Porcelain Fuse Unit (Make- Havells/Anchor/Cona/Standard) , 100 S 415V Porcelain Fuse Unit (Make- Havells/Anchor/Cona/Standard) , Replacement Of The Following Burnt Out/Damaged Cable/Wires/Lugs/Sockets Etc. By New One Of Following Types, Sizes And Ratings Frlsh/Hffr Pvc Insulated Single Core (Unsheathed) Bright Annealed Copper Conductor Multistrand Flexible Cable For Voltage Grade Up To 1100V As Per Is694:2010 I/C Laying / Drawing In Existing Conduit/Pipe, Connection, Testing Etc. As Required. , 25Sqmm With Copper Socketing At Both Ends , 16Sqmm With Copper Socketing At Both Ends , 10Sqmm With Copper Socketing At Both Ends , 1 X 6.0 Sq. Mm , 1 X 1.5 Sq. Mm , 2 X 1.5 Sq. Mm , 3 X 1.5 Sq. Mm , 2 X 4 Sq. Mm , 3 X 4 Sq. Mm , Replacement Of The Burnt-Out Cables/Wirings By The Following Sizes Fr Pvc Insulated & Pvc Round Sheathed Multicore Bright Annealed Bare Copper Conductor Flexible Cable For Voltage Grade Up To 1100Volts As Per Is-694-2010 I/C Fixing/Laying On Wall/Ceiling With C Cl S Etc. As Required. , 3 Corex1.5Sqmm , 3 Corex2.5Sqmm , 4 Corex2.5Sqmm , 3 Corex4.0 Sqmm , Supply Of The Following Sizes Pvc Insulated & Pvc Sheathed Aluminium Conductor Armoured Cable 650/1100 V. Grade Confirming To Is : 7098 (Part-1) 1988 I/C Transportation To Respective Sites Etc. As Required For Replacement Of Faulty/Burnt Out Cables. , 2 Core 6 Sqmm , 4 Core 10 Sqmm , 4 Core 16 Sqmm , 4 Core 25 Sqmm , 3.5 Core 50Sqmm , Replacement Of Damaged Mv Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. , 2 X 6 Sq. Mm (19Mm) , 4 X 16 Sq. Mm (28Mm) , 4 X 25 Sq. Mm (28Mm) , 3½ X 50 Sq. Mm (35Mm) , Replacement Of Faulty Service Connection Cables By New One Of 2 Core X 4Sqmm Pvc Insulated And Pvc Sheathed Aluminium Conductor Weather Proof Cable Etc. As Required. , Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Rcc/ Hume/ Metal Pipe As Required. , Up To 35Sqmm , Above 35 Sq. Mm And Up To 95 Sq. Mm , Laying And Fixing Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size On Wall Surface As Required. , Up To 35Sqmm , Above 35 Sq. Mm And Up To 95 Sq. Mm (Cl Ed With 25X3mm Ms Flat Cl ) , Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size Up To 35Sqmm Direct In Ground Including Excavation And Refilling The Trench Etc As Required, But Excluding Sand Cushioning And Protective Covering. , Up To 35Sqmm , Above 35 Sq. Mm And Up To 95 Sq. Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size Up To 35Sqmm In The Existing Duct/Air As Required. , Up To 35Sqmm , Above 35 Sq. Mm And Up To 95 Sq. Mm (Cl Ed With 25X3mm Ms Flat Cl ) , Replacement Of Faulty Sdfus/Sfus By New Ones Of Following Ratings Switch Disconnector Fuse Units (Sdfu) With Din Type Hrc Fuse Links (Open Execution Type) With Terminal Shrouds On Both Sides And Phase Barriers Included, Telescopic Shaft For Depth Adjustment Conforms To Iec 60947-3, Is/Iec 60947-3 (Open Execution Type) After Dismantling The Old Defective Sdfu/Sfu, Fixing Of The New One, Connection & Testing Etc. As Required. (Make: Lk Fn Type/Equivalent Model Of Siemens/Abb/Havells) . , 63 S 415 Volts Tpn Switch Disconnector Fuse Units (Sdfu) With Din Type Hrc Fuse Links , 100 S 415 Volts Tpn Switch Disconnector Fuse Units (Sdfu) With Din Type Hrc Fuse Links , Replacement Of Faulty Sdfus/Sfus By New Ones Of Following Ratings Switch Disconnector Fuse Units (Sdfu) With Hrc Fuse Links In Spacious Sheet Steel Enclosures, So That There Will Be No Need Of Separate Cable Gland Boxes, Having Terminal Shrouds And Phase Barriers On Both Sides Suitable For Cylindrical/Din Type Hrc Fuse Links, Confirming To Iec-60947-3, Is/Iec:60947-3, After Dismantling The Old Defective Sdfu/Sfu, Fixing Of The New One Connection & Testing Etc. As Required. (Make: Lk Fn Type/Equivalent Model Of Siemens/Abb/Havells) . , 63 S 415 Volts Tpn Sdfu In Sheet Steel Enclosure With Din Type Hrc Fuses , 100 S 415 Volts Tpn Sdfu In Sheet Steel Enclosure With Din Type Hrc Fuses , Replacement Of Faulty Change Over Switches By New Onload Type Change Over Switch Disconnector Of Following Ratings In Spacious Sheet Steel Enclosure So That There May Not Be Need Of Separate Cable End Boxes, Having Terminal Shrouds, Source Separator And Phase Barriers, Staggered Terminals Make Cable Termination Easy Conforms To Iec 60947-3, Is/Iec 60947-3), Suitable For Horizontal As Well As Vertical Mounting After Dismantling The Old Defective Ones, Fixing The New One, Connection & Testing Etc. As Required. (Make: Lk /Equivalent Model Of Siemens/Abb/Havells/Hpl-Socomec) . , 63 , 415V, 50Hz, 4-Pole , 100 , 415V, 50Hz, 4-Pole , 125 , 415V, 50Hz, 4-Pole , Replacement Of Faulty Mccbs By New Ones Of Following Ratings Conforming To Is/Iec 60947-2 & Iec 60947-2, Ics= 100% Of Icu, Adjustable Overload Settings: 0.8 - 1.0 X In, Fixed Short-Circuit Settings: 10 X In, Breaking Capacity 25Ka, Etc. After Dismantling The Old Defective Ones, Fixing This New Mccbs, Connection & Testing Etc. As Required. (Make-Lk Type- Dz0-125C /Equivalent Model Of Siemens/Abb) , 63 S 3 Pole 415 Volts 50 Hz , 63 S 4 Pole 415 Volts 50 Hz , 100 S 3Pole 415 Volts 50 Hz , 100 S 4Pole 415 Volts 50 Hz , Replacement Of Faulty And Damaged Ftl Fittings By New One Of Following Ratings, 65000K Cool Day Light Suitable For Operation On 140 Volts To 270 Volts Ac, 50Hz I/C Fixing And Connection Etc. As Required. , 20/22 Watt 65000K Led Batten Polycarbonate/Aluminium Body. (Make-(Philips Ujjwal 20-Watt Led Batten / Equivalent Model Of Surya / Polycab / Crompton) , 12 Watt 6500K Led Full Glow Metal Surface Round Light Fittings Minimum Luminous Efficacy - 100Lm/Watt (Make- Phillips/Equivalent Model Of Havells/Crompton) , 18 Watt 6500K Led Full Glow Metal Surface Round Light Fittings Minimum Luminous Efficacy - 100Lm/Watt (Make- Phillips /Equivalent Model Of Havells /Crompton) , 10Watt 6000K, 850Lumen Led Bulk Head Wall Light (Make- Phillips/ Havells/ Crompton) , 15/16W Led Bulb Suitable For B22 L Holder, Color Temperature: 6500K, Lumens: 1700Lm, Operating Voltage: 220-240 Volts, Low Energy Consumption And Non-Dimmable Type. , 30W Led Bulb (A19) , Crystal White, Energy Efficient, Operating Voltage: 220-240 Volts, Suitable For Indoor And Outdoor Use And Fixing In B22d Holder Etc. As Required. , Mounting Rail For Tled L S./ Led Tubes In Surface Suspended And Wall Mounted Led Batten Having Crca Housing Suitable For Operation On 140-270V 50Hz Ac Supply Including Connection , Testing Etc. As Required. (Make:Phillips, Model- Tmc 502 1Xt-Led 22W) , Mounting Rail For Tled L S./ Led Tubes In Surface Suspended And Wall Mounted Led Batten Having Crca Housing Suitable For Operation On 140-270V 50Hz Ac Supply Including Connection , Testing Etc. As Required. (Make:Phillips, Model-Tmc 502 2Xt-Led 22W) , 20W 4Ft Ultra Bright Led Tube Light With Very High Efficacy 2100Lumen, 6500K & Thd<15%, Single Side Wiring Suitable For Installation In Existing Flt Fixtures Having G13 L Holders In Replacement Of Conventional Fluorescent Tubes. Faulty Led Tubes I/C Connection Etc. As Required. (Make-Phillips/Bajaj/Crompton/Havells). , Replacement Of The L Holders/Ceiling Roses Etc. By New Ones Of Reputed Makes Etc. As Required. , Angle/Batten Holder , 36/40 W Fl Tube Light Holder , Ceiling Rose (3 Plate) , 5/6 S 250 Volts 3 Pin Plug Top , 15/16 S 250 Volts 3 Pin Plug Top , Supplying And Fixing Following Modular Type / Piano Type Switch/ Socket On The Existing Modular Plate/Switch Box Including Connections Etc. As Required. , 6/10 A One Way Modular Switch , 3 Pin 6/10 A Modular Socket , 16/20A Modular Switch , 6 Pin 16/20A Modular Socket , Modular Type Bell Push , 6 /10 S 1 Way Piano Type Switch , 20 S 1 Way Piano Type Switch , 6 S 3 Pin Piano Type Socket , 16 S 3 Pin Piano Type Socket , Supplying And Fixing Following Size/ Modules, Gi Box (At Least 1.2Mm Thick) Along With Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required. , 1 Or 2 Module (75 Mmx75 Mm) , 3 Module (100 Mmx75 Mm) , 4 Module (125 Mmx75 Mm) , 6 Module (200 Mmx75 Mm) , 8 Module (125 Mmx125 Mm) , 12 Module (200 Mmx150 Mm) , Carry Out Repairing Of Electrical Light Fittings By Arranging Qualified And Trained Man Power And Tools, Tackles, Ladders Etc. I/C Dismantling Of Defective/Faulty Components And Fixing Of New Components I.E Chokes, L S, Starters, Interconnection Wires, L Holders Etc. As Required. , Replacement Of Faulty And Unserviceable Ceiling Fan By New Ones Of 1200Mm Sweep, 3Nos Aluminium Blades, Isi Marked Minimum 1-Star Rated, Copper Wound Induction Motor, 350Rpm, Min Air Delivery 226M3/Min, Powder Coated With 260Mm Down Rod Suitable For Operation On 230V 50Hz Ac Supply I/C Installation, Connection And Testing Etc. As Required. (Havells Andria/Ambose Es/Artemis With 2 Years Warranty Or Equivalent Of Usha/Bajaj/Crompton) , Rewinding Of 1200Mm/1400Mm Ceiling Fan By Superior Quality Super Enameled Copper Conductor I/C Heat Varnishing, Testing Etc. As Required. , Overhauling Of Ceiling Fan I/C Dismantling, Heat Varnishing Of Windings, Greasing Of Bearings, Refitting, Testing Etc. As Required. , Replacement Of The Defective Capacitors / Fan Regulators/ Bearings For Ceiling Fans Etc. By The New One Of Following Ratings Etc. As Required. (Make- Anchor/Havells/Cona/Isi) , Stepped Type Electronic Fan Regulator (Switch Type) , Modular Fan Regulator (2 Modules) 5 Steps , Modular Fan Regulator (1 Module) , 2.25 Mfd 440 Volts Capacitor For Ceiling Fan , Bearings For Ceiling Fans (6201 & 6202) Etc. As Required. (Make: Skf/Ss) , Ceiling Fan Cl S Heavy Duty Mild Steel Zinc Golden Colour With Rubber (Shackle Set) , S/F Of Mcb Protected Socket Outlet 4 Module With Metal Box Comprising Of 01No. 25 S Socket And 01No. 25 S Plug And 01No. 25 S C Series Spmcb For Split Ac Units I/C Connection, Testing Etc. As Required. (Make- Legrand /Havells/Hpl/Standard) , Replacement Of Burn Out Sockets/Lugs Of Cables By New Ones Of Following Types And Sizes I/C Dismantling The Burnt Out Portion Of Cables/Wires, Crimping/Fixing Of New Sockets/Lugs Etc. (Dowells / Comet / Hex Connect Well / Ss) , For 16Sqmm Al Conductor Armoured Cable , For 25/35Sqmm Al Conductor Armoured Cable , For 50/70Sqmm Al Conductor Armoured Cable , Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. , 20Mm , 25Mm , 32Mm , Supplying And Fixing Following Way, Horizontal Type Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 V, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/ Isolator). (Make-Legrand/L&T/Siemens/Schneider) , 4 Way (8 + 12) With Metal Door (Ip43) , Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) (Make-Legrand/L&T/Siemens/Schneider) , 8 Way With Metal Door (Ip43) , 12 Way With Metal Door (Ip43) , Supply And Fixing Of Following Watt Led Street Light Fitting Delivering >100 Lumen/Watt With Pdc Housing And Street Light Optics To Ensure Uniform Distribution Having Bottom Opening Separate Driver Compartment With Ip66 Protection And Impact Resistance Of Ik08.. , 30 Watt (Make-Phillips Model Brp030 P Led35 Cw Slr Gr Psu Spd/Equivalent Model Of Havells/Crompton) , 45 Watt (Make-Phillips Model Brp031 Led45 Cw Slr Gr Psu Spd/Equivalent Model Of Havells/Crompton) , Replacement Of Damaged Loop In And Loop Out Boxes By Smc Junction Box Of Size 103Mm X 103Mm X 70Mm (Inside Dimensions) With Hinged Door Type Including Supply And Fixing Of 1No. 2 Pole Stud Connector With Nuts And Bolts Etc. As Required. (Sintex Gsjb1111/Ss) , Supply And Fixing Of Smc Junction Box Of Size 200Mm X 140Mm X 95Mm (Inside Dimensions) With Hinged Door Type Including Supply And Fixing Of 1No. 4 Pole Stud Connector With Nuts And Bolts Etc. As Required. (Sintex Gsjb2014/Ss) , Repairing Of Compound Light By Dismantling The Old Damaged Fitting From The Pole By Arranging Of Ladder, Skill Manpower And Fixing Of New Led Fitting I/C Rewiring From Loop Box To Led Fitting If Required Etc Complete As Required. , Supplying & Drawing Of 12 Swg Gi Insulated Wire For Stringing Of Service Cable On Overhead Etc As Required. , Replacement Of Damaged Compound Light Brackets By 32 Mm Dia X 1.2Metres Long G.I. Pipe (Medium Class) Bracket Along With 2 Nos. 32M Gi Cl S With Nuts, Bolts And Washers For Mounting Of Street Light Fitting On Pole Including Bending The Pipe To The Required Shape Etc. Including Cost Of All Materials As Required. , Supply Of Hot Pressed Molded Smc Junction Box, Hinged Double Door Type Of Following Sizes Suitable For Application For Fixing Electrical Controls /Switch Gears/Meters Etc. With Provision For Cable Entry/Exit From Bottom/Side , Locking Arrangements Including Supply And Fixing Of 2Nos 4 Pole Stud Connectors, Interconnections With Suitable Size Single Core Pvc Insulated Copper Conductor Cable With Copper Sockets/Lugs Including Fixing On Existing Pole / Existing Ms/Gi Angle Stands Etc. Complete As Required. , Size Not Less Than 650Mmx350mmx250mm (Inside Dimensions) (Make-Sintex Model: Sintex Jb-6535/Ss) , Size Not Less Than 400Mmx300mmx190mm (Inside Dimensions) (Make-Sintex Model: Sintex Jb-4030/Ss) , Making Suitable Angle Base Frame Made Of 40Mmx40mmx5mm Ms Angle For Installation Of Mentioned Smc Junction / Meter Boxes , Cutting, Welding, Fabricating, Grouting The Same On Ground With Required Pcc Work Complete As Required. , Liaison With The Electricity Discoms For Taking Shutdown Of Lt/Mv Lines For Checking, Testing And Replacement Of Faulty Service Connection Cable/Energy Meter/ Meter Box/Feeder Panel Etc. And Re Energization Of Power Supply After Replacement Of Faulty Components As Above / Removal Of Faults Etc. Complete As Required.

BOQ

Sl. No. Item TitleItem Description
1Attending Electrical Faults of LT/MV electrical system comprising of LT/MV Service connection line, Feeder panel, Main Distribution panel, MCB DBs, Riser mains etc. on need basis by deputing qualified and trained/skilled technician having valid Electrical License of appropriate voltage and making arrangements for checking, testing with suitable testing devices, fault finding, replacing faulty MCBs/Isolators/Switches/lamps/holders etc. by new ones (cost of materials are not included in the scope of this item and will be paid separately) and restoration of the Power supply to the Telephone Exchange/Admin Bldg/BTS/Staff Quarters complex etc. complete as required.Attending Electrical Faults of LT/MV electrical system comprising of LT/MV Service connection line, Feeder panel, Main Distribution panel, MCB DBs, Riser mains etc. on need basis by deputing qualified and trained/skilled technician having valid Electrical License of appropriate voltage and making arrangements for checking, testing with suitable testing devices, fault finding, replacing faulty MCBs/Isolators/Switches/lamps/holders etc. by new ones (cost of materials are not included in the scope of this item and will be paid separately) and restoration of the Power supply to the Telephone Exchange/Admin Bldg/BTS/Staff Quarters complex etc. complete as required.
2Sites within a distance of ≤15 Kms from BA HQSites within a distance of ≤15 Kms from BA HQ
3Sites within a distance of >15 Kms and ≤ 50Kms from BA HQSites within a distance of >15 Kms and ≤ 50Kms from BA HQ
4Sites within a distance of >50 Kms and ≤ 100Kms from BA HQSites within a distance of >50 Kms and ≤ 100Kms from BA HQ
5Sites within a distance of >100 Kms and ≤ 150Kms from BA HQSites within a distance of >100 Kms and ≤ 150Kms from BA HQ
6Sites within a distance of >150 Kms and ≤ 200Kms from BA HQSites within a distance of >150 Kms and ≤ 200Kms from BA HQ
7Supplying and fixing 6A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make-Legrand/L&T/Siemens/Schneider)Supplying and fixing 6A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make-Legrand/L&T/Siemens/Schneider)
8Single poleSingle pole
9Double poleDouble pole
10Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
1140 A40 A
1263 A63 A
13Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make-Legrand/L&T/Siemens/Schneider)Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make-Legrand/L&T/Siemens/Schneider)
1463 A63 A
15100 A100 A
16Replacement of the faulty and burn out HRC Fuse links and Porcelain Fuse units (Fuse Carrier and base) by new ones of following ratings i/c connection testing etc. as required. (Make-Legrand / L&T / Schneider Electric / Siemens/Havells)Replacement of the faulty and burn out HRC Fuse links and Porcelain Fuse units (Fuse Carrier and base) by new ones of following ratings i/c connection testing etc. as required. (Make-Legrand / L&T / Schneider Electric / Siemens/Havells)
1732 Amps 415V HRC Fuse links- Cylindrical type (L&T/Havells)32 Amps 415V HRC Fuse links- Cylindrical type (L&T/Havells)
1863 Amps 415V HRC Fuse links- Cylindrical type (L&T/Havells)63 Amps 415V HRC Fuse links- Cylindrical type (L&T/Havells)
1932 Amps 415V HRC Fuse links-Bolted type (L&T/Havells)32 Amps 415V HRC Fuse links-Bolted type (L&T/Havells)
2063 Amps 415V HRC Fuse links- Bolted type (L&T/Havells)63 Amps 415V HRC Fuse links- Bolted type (L&T/Havells)
21100 Amps 415V HRC Fuse links- DIN type (L&T/Havells)100 Amps 415V HRC Fuse links- DIN type (L&T/Havells)
2263 Amps 415V Porcelain Fuse unit (Make- Havells/Anchor/Cona/Standard)63 Amps 415V Porcelain Fuse unit (Make- Havells/Anchor/Cona/Standard)
23100 Amps 415V Porcelain Fuse unit (Make- Havells/Anchor/Cona/Standard)100 Amps 415V Porcelain Fuse unit (Make- Havells/Anchor/Cona/Standard)
24Replacement of the following burnt out/damaged cable/wires/lugs/sockets etc. by new one of following types, sizes and ratings FRLSH/HFFR PVC insulated single core (unsheathed) bright annealed copper conductor multistrand flexible cable for voltage grade up to 1100V as per IS694:2010 i/c laying / drawing in existing conduit/pipe, connection, testing etc. as required.Replacement of the following burnt out/damaged cable/wires/lugs/sockets etc. by new one of following types, sizes and ratings FRLSH/HFFR PVC insulated single core (unsheathed) bright annealed copper conductor multistrand flexible cable for voltage grade up to 1100V as per IS694:2010 i/c laying / drawing in existing conduit/pipe, connection, testing etc. as required.
2525sqmm with copper socketing at both ends25sqmm with copper socketing at both ends
2616sqmm with copper socketing at both ends16sqmm with copper socketing at both ends
2710sqmm with copper socketing at both ends10sqmm with copper socketing at both ends
281 x 6.0 sq. mm1 x 6.0 sq. mm
291 x 1.5 sq. mm1 x 1.5 sq. mm
302 x 1.5 sq. mm2 x 1.5 sq. mm
313 x 1.5 sq. mm3 x 1.5 sq. mm
322 x 4 sq. mm2 x 4 sq. mm
333 x 4 sq. mm3 x 4 sq. mm
34Replacement of the burnt-out cables/wirings by the following sizes FR PVC insulated & PVC round sheathed multicore bright annealed bare copper conductor flexible cable for voltage grade up to 1100volts as per IS-694-2010 i/c fixing/laying on wall/ceiling with C clamps etc. as required.Replacement of the burnt-out cables/wirings by the following sizes FR PVC insulated & PVC round sheathed multicore bright annealed bare copper conductor flexible cable for voltage grade up to 1100volts as per IS-694-2010 i/c fixing/laying on wall/ceiling with C clamps etc. as required.
353 coreX1.5sqmm3 coreX1.5sqmm
363 coreX2.5sqmm3 coreX2.5sqmm
374 coreX2.5sqmm4 coreX2.5sqmm
383 coreX4.0 sqmm3 coreX4.0 sqmm
39Supply of the following sizes PVC insulated & PVC sheathed Aluminium conductor armoured cable 650/1100 V. grade confirming to IS : 7098 (Part-1) 1988 i/c transportation to respective sites etc. as required for replacement of faulty/burnt out cables.Supply of the following sizes PVC insulated & PVC sheathed Aluminium conductor armoured cable 650/1100 V. grade confirming to IS : 7098 (Part-1) 1988 i/c transportation to respective sites etc. as required for replacement of faulty/burnt out cables.
402 core 6 sqmm2 core 6 sqmm
414 core 10 sqmm4 core 10 sqmm
424 core 16 sqmm4 core 16 sqmm
434 core 25 sqmm4 core 25 sqmm
443.5 core 50sqmm3.5 core 50sqmm
45Replacement of damaged MV cable end terminations with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.Replacement of damaged MV cable end terminations with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
462 X 6 sq. mm (19mm)2 X 6 sq. mm (19mm)
474 X 16 sq. mm (28mm)4 X 16 sq. mm (28mm)
484 X 25 sq. mm (28mm)4 X 25 sq. mm (28mm)
493½ X 50 sq. mm (35mm)3½ X 50 sq. mm (35mm)
50Replacement of faulty service connection cables by new one of 2 core X 4sqmm PVC insulated and PVC sheathed Aluminium conductor weather proof cable etc. as required.Replacement of faulty service connection cables by new one of 2 core X 4sqmm PVC insulated and PVC sheathed Aluminium conductor weather proof cable etc. as required.
51Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
52Up to 35sqmmUp to 35sqmm
53Above 35 sq. mm and up to 95 sq. mmAbove 35 sq. mm and up to 95 sq. mm
54Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
55Up to 35sqmmUp to 35sqmm
56Above 35 sq. mm and up to 95 sq. mm (clamped with 25x3mm MS flat clamp)Above 35 sq. mm and up to 95 sq. mm (clamped with 25x3mm MS flat clamp)
57Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size Up to 35sqmm direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size Up to 35sqmm direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.
58Up to 35sqmmUp to 35sqmm
59Above 35 sq. mm and up to 95 sq. mmAbove 35 sq. mm and up to 95 sq. mm
60Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size Up to 35sqmm in the existing Duct/Air as required.Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size Up to 35sqmm in the existing Duct/Air as required.
61Up to 35sqmmUp to 35sqmm
62Above 35 sq. mm and up to 95 sq. mm (clamped with 25x3mm MS flat clamp)Above 35 sq. mm and up to 95 sq. mm (clamped with 25x3mm MS flat clamp)
63Replacement of faulty SDFUs/SFUs by new ones of following ratings Switch Disconnector Fuse Units (SDFU) with Din type HRC fuse links (Open execution type) with Terminal Shrouds on both sides and Phase Barriers included, Telescopic shaft for depth adjustment Conforms to IEC 60947-3, IS/IEC 60947-3 (open execution type) after dismantling the old defective SDFU/SFU, fixing of the new one, connection & testing etc. as required. (Make: LK FN type/Equivalent model of Siemens/ABB/Havells) .Replacement of faulty SDFUs/SFUs by new ones of following ratings Switch Disconnector Fuse Units (SDFU) with Din type HRC fuse links (Open execution type) with Terminal Shrouds on both sides and Phase Barriers included, Telescopic shaft for depth adjustment Conforms to IEC 60947-3, IS/IEC 60947-3 (open execution type) after dismantling the old defective SDFU/SFU, fixing of the new one, connection & testing etc. as required. (Make: LK FN type/Equivalent model of Siemens/ABB/Havells) .
6463 Amps 415 volts TPN Switch Disconnector Fuse Units (SDFU) with Din type HRC fuse links63 Amps 415 volts TPN Switch Disconnector Fuse Units (SDFU) with Din type HRC fuse links
65100 Amps 415 volts TPN Switch Disconnector Fuse Units (SDFU) with Din type HRC fuse links100 Amps 415 volts TPN Switch Disconnector Fuse Units (SDFU) with Din type HRC fuse links
66Replacement of faulty SDFUs/SFUs by new ones of following ratings Switch Disconnector Fuse Units (SDFU) with HRC fuse links in spacious sheet steel enclosures, so that there will be no need of separate cable gland boxes, having terminal shrouds and phase barriers on both sides suitable for Cylindrical/DIN type HRC fuse links, confirming to IEC-60947-3, IS/IEC:60947-3, after dismantling the old defective SDFU/SFU, fixing of the new one connection & testing etc. as required. (Make: LK FN type/Equivalent model of Siemens/ABB/Havells) .Replacement of faulty SDFUs/SFUs by new ones of following ratings Switch Disconnector Fuse Units (SDFU) with HRC fuse links in spacious sheet steel enclosures, so that there will be no need of separate cable gland boxes, having terminal shrouds and phase barriers on both sides suitable for Cylindrical/DIN type HRC fuse links, confirming to IEC-60947-3, IS/IEC:60947-3, after dismantling the old defective SDFU/SFU, fixing of the new one connection & testing etc. as required. (Make: LK FN type/Equivalent model of Siemens/ABB/Havells) .
6763 Amps 415 volts TPN SDFU in Sheet steel enclosure with DIN type HRC fuses63 Amps 415 volts TPN SDFU in Sheet steel enclosure with DIN type HRC fuses
68100 Amps 415 volts TPN SDFU in Sheet steel enclosure with DIN type HRC fuses100 Amps 415 volts TPN SDFU in Sheet steel enclosure with DIN type HRC fuses
69Replacement of faulty Change over switches by new onload type Change Over Switch Disconnector of following ratings in spacious sheet steel enclosure so that there may not be need of separate cable end boxes, having Terminal Shrouds, Source Separator and Phase Barriers, Staggered Terminals make cable termination easy Conforms to IEC 60947-3, IS/IEC 60947-3), Suitable for horizontal as well as vertical mounting after dismantling the old defective ones, fixing the new one, connection & testing etc. as required. (Make: LK /Equivalent model of Siemens/ABB/Havells/HPL-Socomec) .Replacement of faulty Change over switches by new onload type Change Over Switch Disconnector of following ratings in spacious sheet steel enclosure so that there may not be need of separate cable end boxes, having Terminal Shrouds, Source Separator and Phase Barriers, Staggered Terminals make cable termination easy Conforms to IEC 60947-3, IS/IEC 60947-3), Suitable for horizontal as well as vertical mounting after dismantling the old defective ones, fixing the new one, connection & testing etc. as required. (Make: LK /Equivalent model of Siemens/ABB/Havells/HPL-Socomec) .
7063Amp, 415V, 50Hz, 4-pole63Amp, 415V, 50Hz, 4-pole
71100Amp, 415V, 50Hz, 4-pole100Amp, 415V, 50Hz, 4-pole
72125Amp, 415V, 50Hz, 4-pole125Amp, 415V, 50Hz, 4-pole
73Replacement of faulty MCCBs by new ones of following ratings Conforming to IS/IEC 60947-2 & IEC 60947-2, Ics= 100% of Icu, Adjustable overload settings: 0.8 - 1.0 x In, Fixed short-circuit settings: 10 x In, Breaking Capacity 25KA, etc. after dismantling the old defective ones, fixing this new MCCBs, connection & testing etc. as required. (make-LK Type- DZ0-125C /Equivalent model of Siemens/ABB)Replacement of faulty MCCBs by new ones of following ratings Conforming to IS/IEC 60947-2 & IEC 60947-2, Ics= 100% of Icu, Adjustable overload settings: 0.8 - 1.0 x In, Fixed short-circuit settings: 10 x In, Breaking Capacity 25KA, etc. after dismantling the old defective ones, fixing this new MCCBs, connection & testing etc. as required. (make-LK Type- DZ0-125C /Equivalent model of Siemens/ABB)
7463Amps 3 pole 415 volts 50 Hz63Amps 3 pole 415 volts 50 Hz
7563Amps 4 pole 415 volts 50 Hz63Amps 4 pole 415 volts 50 Hz
76100Amps 3pole 415 volts 50 Hz100Amps 3pole 415 volts 50 Hz
77100Amps 4pole 415 volts 50 Hz100Amps 4pole 415 volts 50 Hz
78Replacement of faulty and damaged FTL fittings by new one of following ratings, 65000K Cool Day Light suitable for operation on 140 volts to 270 volts AC, 50Hz i/c fixing and connection etc. as required.Replacement of faulty and damaged FTL fittings by new one of following ratings, 65000K Cool Day Light suitable for operation on 140 volts to 270 volts AC, 50Hz i/c fixing and connection etc. as required.
7920/22 watt 65000K LED Batten Polycarbonate/Aluminium body. (Make-(Philips Ujjwal 20-Watt LED Batten / Equivalent model of Surya / Polycab / Crompton)20/22 watt 65000K LED Batten Polycarbonate/Aluminium body. (Make-(Philips Ujjwal 20-Watt LED Batten / Equivalent model of Surya / Polycab / Crompton)
8012 watt 6500K LED full glow metal surface round light fittings minimum luminous efficacy - 100lm/watt (make- Phillips/Equivalent model of Havells/Crompton)12 watt 6500K LED full glow metal surface round light fittings minimum luminous efficacy - 100lm/watt (make- Phillips/Equivalent model of Havells/Crompton)
8118 watt 6500K LED full glow metal surface round light fittings minimum luminous efficacy - 100lm/watt (make- Phillips /Equivalent model of Havells /Crompton)18 watt 6500K LED full glow metal surface round light fittings minimum luminous efficacy - 100lm/watt (make- Phillips /Equivalent model of Havells /Crompton)
8210watt 6000K, 850lumen LED Bulk Head wall light (Make- Phillips/ Havells/ Crompton)10watt 6000K, 850lumen LED Bulk Head wall light (Make- Phillips/ Havells/ Crompton)
8315/16W LED Bulb suitable for B22 lamp holder, Color Temperature: 6500K, Lumens: 1700lm, Operating Voltage: 220-240 volts, Low energy consumption and non-dimmable type.15/16W LED Bulb suitable for B22 lamp holder, Color Temperature: 6500K, Lumens: 1700lm, Operating Voltage: 220-240 volts, Low energy consumption and non-dimmable type.
8430W LED Bulb (A19) , crystal white, energy efficient, Operating Voltage: 220-240 volts, suitable for indoor and outdoor use and fixing in B22D holder etc. as required.30W LED Bulb (A19) , crystal white, energy efficient, Operating Voltage: 220-240 volts, suitable for indoor and outdoor use and fixing in B22D holder etc. as required.
85Mounting rail for TLED lamps./ LED tubes in surface suspended and wall mounted LED batten having CRCA housing suitable for operation on 140-270V 50HZ AC supply including connection , testing etc. as required. (Make:Phillips, Model- TMC 502 1xT-LED 22W)Mounting rail for TLED lamps./ LED tubes in surface suspended and wall mounted LED batten having CRCA housing suitable for operation on 140-270V 50HZ AC supply including connection , testing etc. as required. (Make:Phillips, Model- TMC 502 1xT-LED 22W)
86Mounting rail for TLED lamps./ LED tubes in surface suspended and wall mounted LED batten having CRCA housing suitable for operation on 140-270V 50HZ AC supply including connection , testing etc. as required. (Make:Phillips, Model-TMC 502 2xT-LED 22W)Mounting rail for TLED lamps./ LED tubes in surface suspended and wall mounted LED batten having CRCA housing suitable for operation on 140-270V 50HZ AC supply including connection , testing etc. as required. (Make:Phillips, Model-TMC 502 2xT-LED 22W)
8720W 4ft ultra bright LED Tube light with very high efficacy 2100Lumen, 6500K & THD<15%, single side wiring suitable for installation in existing FLT fixtures having G13 lamp holders in replacement of conventional fluorescent tubes. faulty LED tubes i/c connection etc. as required. (Make-Phillips/Bajaj/Crompton/Havells).20W 4ft ultra bright LED Tube light with very high efficacy 2100Lumen, 6500K & THD<15%, single side wiring suitable for installation in existing FLT fixtures having G13 lamp holders in replacement of conventional fluorescent tubes. faulty LED tubes i/c connection etc. as required. (Make-Phillips/Bajaj/Crompton/Havells).
88Replacement of the lamp holders/ceiling roses etc. by new ones of reputed makes etc. as required.Replacement of the lamp holders/ceiling roses etc. by new ones of reputed makes etc. as required.
89Angle/batten HolderAngle/batten Holder
9036/40 W Fl Tube light holder36/40 W Fl Tube light holder
91Ceiling Rose (3 plate)Ceiling Rose (3 plate)
925/6Amps 250 Volts 3 pin Plug top5/6Amps 250 Volts 3 pin Plug top
9315/16Amps 250 Volts 3 pin Plug top15/16Amps 250 Volts 3 pin Plug top
94Supplying and fixing following modular type / Piano type switch/ socket on the existing modular plate/switch box including connections etc. as required.Supplying and fixing following modular type / Piano type switch/ socket on the existing modular plate/switch box including connections etc. as required.
956/10 A One way Modular switch6/10 A One way Modular switch
963 pin 6/10 A Modular socket3 pin 6/10 A Modular socket
9716/20A Modular switch16/20A Modular switch
986 pin 16/20A Modular socket6 pin 16/20A Modular socket
99Modular type Bell pushModular type Bell push
1006 /10 Amps 1 way piano type switch6 /10 Amps 1 way piano type switch
10120 Amps 1 way piano type switch20 Amps 1 way piano type switch
1026 Amps 3 pin piano type socket6 Amps 3 pin piano type socket
10316 Amps 3 pin piano type socket16 Amps 3 pin piano type socket
104Supplying and fixing following size/ modules, GI box (at least 1.2mm thick) along with modular base & cover plate for modular switches in recess etc. as required.Supplying and fixing following size/ modules, GI box (at least 1.2mm thick) along with modular base & cover plate for modular switches in recess etc. as required.
1051 or 2 Module (75 mmX75 mm)1 or 2 Module (75 mmX75 mm)
1063 Module (100 mmX75 mm)3 Module (100 mmX75 mm)
1074 Module (125 mmX75 mm)4 Module (125 mmX75 mm)
1086 Module (200 mmX75 mm)6 Module (200 mmX75 mm)
1098 Module (125 mmX125 mm)8 Module (125 mmX125 mm)
11012 Module (200 mmX150 mm)12 Module (200 mmX150 mm)
111Carry out repairing of Electrical Light Fittings by arranging qualified and trained man power and tools, tackles, ladders etc. i/c dismantling of defective/faulty components and fixing of new components i.e chokes, lamps, starters, interconnection wires, lamp holders etc. as required.Carry out repairing of Electrical Light Fittings by arranging qualified and trained man power and tools, tackles, ladders etc. i/c dismantling of defective/faulty components and fixing of new components i.e chokes, lamps, starters, interconnection wires, lamp holders etc. as required.
112Replacement of faulty and unserviceable Ceiling Fan by new ones of 1200mm sweep, 3nos aluminium blades, ISI marked minimum 1-Star rated, copper wound induction motor, 350RPM, min air delivery 226m3/min, powder coated with 260mm down rod suitable for operation on 230V 50HZ AC supply i/c installation, connection and testing etc. as required. (Havells Andria/Ambose ES/Artemis with 2 years warranty Or Equivalent of Usha/Bajaj/Crompton)Replacement of faulty and unserviceable Ceiling Fan by new ones of 1200mm sweep, 3nos aluminium blades, ISI marked minimum 1-Star rated, copper wound induction motor, 350RPM, min air delivery 226m3/min, powder coated with 260mm down rod suitable for operation on 230V 50HZ AC supply i/c installation, connection and testing etc. as required. (Havells Andria/Ambose ES/Artemis with 2 years warranty Or Equivalent of Usha/Bajaj/Crompton)
113Rewinding of 1200mm/1400mm ceiling fan by superior quality super enameled copper conductor i/c heat varnishing, testing etc. as required.Rewinding of 1200mm/1400mm ceiling fan by superior quality super enameled copper conductor i/c heat varnishing, testing etc. as required.
114Overhauling of Ceiling Fan i/c dismantling, heat varnishing of windings, greasing of bearings, refitting, testing etc. as required.Overhauling of Ceiling Fan i/c dismantling, heat varnishing of windings, greasing of bearings, refitting, testing etc. as required.
115Replacement of the defective Capacitors / Fan regulators/ bearings for ceiling fans etc. by the new one of following ratings etc. as required. (Make- Anchor/Havells/Cona/ISI)Replacement of the defective Capacitors / Fan regulators/ bearings for ceiling fans etc. by the new one of following ratings etc. as required. (Make- Anchor/Havells/Cona/ISI)
116Stepped type Electronic Fan Regulator (Switch type)Stepped type Electronic Fan Regulator (Switch type)
117Modular Fan Regulator (2 Modules) 5 stepsModular Fan Regulator (2 Modules) 5 steps
118Modular Fan Regulator (1 Module)Modular Fan Regulator (1 Module)
1192.25 mfd 440 volts Capacitor for Ceiling Fan2.25 mfd 440 volts Capacitor for Ceiling Fan
120Bearings for Ceiling fans (6201 & 6202) etc. as required. (Make: SKF/SS)Bearings for Ceiling fans (6201 & 6202) etc. as required. (Make: SKF/SS)
121Ceiling Fan clamps heavy duty mild steel zinc golden colour with rubber (Shackle set)Ceiling Fan clamps heavy duty mild steel zinc golden colour with rubber (Shackle set)
122S/F of MCB protected Socket outlet 4 module with metal box comprising of 01no. 25Amps socket and 01no. 25Amps Plug and 01no. 25Amps \\"C\\" series SPMCB for Split AC units i/c connection, testing etc. as required. (Make- Legrand /Havells/HPL/Standard)S/F of MCB protected Socket outlet 4 module with metal box comprising of 01no. 25Amps socket and 01no. 25Amps Plug and 01no. 25Amps \\"C\\" series SPMCB for Split AC units i/c connection, testing etc. as required. (Make- Legrand /Havells/HPL/Standard)
123Replacement of burn out Sockets/lugs of cables by new ones of following types and sizes i/c dismantling the burnt out portion of cables/wires, crimping/fixing of new sockets/lugs etc. (Dowell's / Comet / Hex Connect well / SS)Replacement of burn out Sockets/lugs of cables by new ones of following types and sizes i/c dismantling the burnt out portion of cables/wires, crimping/fixing of new sockets/lugs etc. (Dowell's / Comet / Hex Connect well / SS)
124For 16sqmm Al Conductor Armoured cableFor 16sqmm Al Conductor Armoured cable
125For 25/35sqmm Al Conductor Armoured cableFor 25/35sqmm Al Conductor Armoured cable
126For 50/70sqmm Al Conductor Armoured cableFor 50/70sqmm Al Conductor Armoured cable
127Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
12820mm20mm
12925mm25mm
13032mm32mm
131Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator). (Make-Legrand/L&T/Siemens/Schneider)Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator). (Make-Legrand/L&T/Siemens/Schneider)
1324 way (8 + 12) with metal door (IP43)4 way (8 + 12) with metal door (IP43)
133Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (Make-Legrand/L&T/Siemens/Schneider)Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (Make-Legrand/L&T/Siemens/Schneider)
1348 way with metal door (IP43)8 way with metal door (IP43)
13512 way with metal door (IP43)12 way with metal door (IP43)
136Supply and fixing of following watt LED street light fitting delivering >100 lumen/watt with PDC housing and street light optics to ensure uniform distribution having Bottom Opening separate driver compartment with IP66 protection and impact resistance of IK08..Supply and fixing of following watt LED street light fitting delivering >100 lumen/watt with PDC housing and street light optics to ensure uniform distribution having Bottom Opening separate driver compartment with IP66 protection and impact resistance of IK08..
13730 watt (Make-Phillips model BRP030 P LED35 CW SLR GR PSU SPD/Equivalent model of Havells/Crompton)30 watt (Make-Phillips model BRP030 P LED35 CW SLR GR PSU SPD/Equivalent model of Havells/Crompton)
13845 watt (Make-Phillips model BRP031 LED45 CW SLR GR PSU SPD/Equivalent model of Havells/Crompton)45 watt (Make-Phillips model BRP031 LED45 CW SLR GR PSU SPD/Equivalent model of Havells/Crompton)
139Replacement of damaged loop in and loop out boxes by SMC Junction box of size 103mm x 103mm x 70mm (inside dimensions) with hinged door type including supply and fixing of 1no. 2 pole stud connector with nuts and bolts etc. as required. (Sintex GSJB1111/SS)Replacement of damaged loop in and loop out boxes by SMC Junction box of size 103mm x 103mm x 70mm (inside dimensions) with hinged door type including supply and fixing of 1no. 2 pole stud connector with nuts and bolts etc. as required. (Sintex GSJB1111/SS)
140Supply and fixing of SMC Junction box of size 200mm x 140mm x 95mm (inside dimensions) with hinged door type including supply and fixing of 1no. 4 pole stud connector with nuts and bolts etc. as required. (Sintex GSJB2014/SS)Supply and fixing of SMC Junction box of size 200mm x 140mm x 95mm (inside dimensions) with hinged door type including supply and fixing of 1no. 4 pole stud connector with nuts and bolts etc. as required. (Sintex GSJB2014/SS)
141Repairing of Compound light by dismantling the old damaged fitting from the pole by arranging of ladder, skill manpower and fixing of new LED fitting i/c rewiring from loop box to LED fitting if required etc complete as required.Repairing of Compound light by dismantling the old damaged fitting from the pole by arranging of ladder, skill manpower and fixing of new LED fitting i/c rewiring from loop box to LED fitting if required etc complete as required.
142Supplying & Drawing of 12 swg GI insulated wire for stringing of service cable on overhead etc as required.Supplying & Drawing of 12 swg GI insulated wire for stringing of service cable on overhead etc as required.
143Replacement of damaged compound light brackets by 32 mm dia X 1.2metres long G.I. pipe (medium class) bracket along with 2 nos. 32m GI clamps with nuts, bolts and washers for mounting of street light fitting on pole including bending the pipe to the required shape etc. including cost of all materials as required.Replacement of damaged compound light brackets by 32 mm dia X 1.2metres long G.I. pipe (medium class) bracket along with 2 nos. 32m GI clamps with nuts, bolts and washers for mounting of street light fitting on pole including bending the pipe to the required shape etc. including cost of all materials as required.
144Supply of Hot pressed molded SMC Junction box, hinged double door type of following sizes suitable for application for fixing Electrical controls /switch gears/meters etc. with provision for cable entry/exit from bottom/side , locking arrangements including supply and fixing of 2nos 4 pole stud connectors, interconnections with suitable size single core PVC insulated copper conductor cable with copper sockets/lugs including fixing on existing pole / existing MS/GI angle stands etc. complete as required.Supply of Hot pressed molded SMC Junction box, hinged double door type of following sizes suitable for application for fixing Electrical controls /switch gears/meters etc. with provision for cable entry/exit from bottom/side , locking arrangements including supply and fixing of 2nos 4 pole stud connectors, interconnections with suitable size single core PVC insulated copper conductor cable with copper sockets/lugs including fixing on existing pole / existing MS/GI angle stands etc. complete as required.
145Size not less than 650mmX350mmX250mm (inside dimensions) (Make-Sintex model: SINTEX JB-6535/SS)Size not less than 650mmX350mmX250mm (inside dimensions) (Make-Sintex model: SINTEX JB-6535/SS)
146Size not less than 400mmX300mmX190mm (inside dimensions) (Make-Sintex model: SINTEX JB-4030/SS)Size not less than 400mmX300mmX190mm (inside dimensions) (Make-Sintex model: SINTEX JB-4030/SS)
147Making suitable angle base frame made of 40mmX40mmX5mm MS angle for installation of mentioned SMC junction / meter boxes , cutting, welding, fabricating, grouting the same on ground with required PCC work complete as required.Making suitable angle base frame made of 40mmX40mmX5mm MS angle for installation of mentioned SMC junction / meter boxes , cutting, welding, fabricating, grouting the same on ground with required PCC work complete as required.
148Liaison with the Electricity DISCOMs for taking shutdown of LT/MV lines for checking, testing and replacement of faulty Service connection cable/Energy Meter/ Meter box/Feeder panel etc. and re energization of power supply after replacement of faulty components as above / removal of faults etc. complete as required.Liaison with the Electricity DISCOMs for taking shutdown of LT/MV lines for checking, testing and replacement of faulty Service connection cable/Energy Meter/ Meter box/Feeder panel etc. and re energization of power supply after replacement of faulty components as above / removal of faults etc. complete as required.

AI Tender Summary

OUR REF NO 56811510
AUTHORITY Government Departments
TENDER VALUE 19.40 Lakhs
LAST DATE 14-08-2026
Authority
Authority Name Department Of Telecommunications
Work Description Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Repair And Maintenance Of Mv Electrical Installation At Te Bts Under Bhubaneswar Ba; Electrical System Or Installation; Service Provider - Attending Electrical Faults Of Lt/Mv Electrical System Comprising Of Lt/Mv Service Connection Line, Feeder Panel, Main Distribution Panel, Mcb Dbs, Riser Mains Etc. On Need Basis By Deputing Qualified And Trained/Skilled Technician Having Valid Electrical License Of Appropriate Voltage And Making Arrangements For Checking, Testing With Suitable Testing Devices, Fault Finding, Replacing Faulty Mcbs/Isolators/Switches/L S/Holders Etc. By New Ones (Cost Of Materials Are Not Included In The Scope Of This Item And Will Be Paid Separately) And Restoration Of The Power Supply To The Telephone Exchange/Admin Bldg/Bts/Staff Quarters Complex Etc. Complete As Required. , Sites Within A Distance Of ≤15 Kms From Ba Hq , Sites Within A Distance Of >15 Kms And ≤ 50Kms From Ba Hq , Sites Within A Distance Of >50 Kms And ≤ 100Kms From Ba Hq , Sites Within A Distance Of >100 Kms And ≤ 150Kms From Ba Hq , Sites Within A Distance Of >150 Kms And ≤ 200Kms From Ba Hq , Supplying And Fixing 6A To 32 A Rating, 240/415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. (Make-Legrand/L&T/Siemens/Schneider) , Single Pole , Double Pole , Supplying And Fixing Following Rating, Double Pole, 240 V, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. , 40 A , 63 A , Supplying And Fixing Following Rating, Four Pole, 415 V, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. (Make-Legrand/L&T/Siemens/Schneider) , 63 A , 100 A , Replacement Of The Faulty And Burn Out Hrc Fuse Links And Porcelain Fuse Units (Fuse Carrier And Base) By New Ones Of Following Ratings I/C Connection Testing Etc. As Required. (Make-Legrand / L&T / Schneider Electric / Siemens/Havells) , 32 S 415V Hrc Fuse Links- Cylindrical Type (L&T/Havells) , 63 S 415V Hrc Fuse Links- Cylindrical Type (L&T/Havells) , 32 S 415V Hrc Fuse Links-Bolted Type (L&T/Havells) , 63 S 415V Hrc Fuse Links- Bolted Type (L&T/Havells) , 100 S 415V Hrc Fuse Links- Din Type (L&T/Havells) , 63 S 415V Porcelain Fuse Unit (Make- Havells/Anchor/Cona/Standard) , 100 S 415V Porcelain Fuse Unit (Make- Havells/Anchor/Cona/Standard) , Replacement Of The Following Burnt Out/Damaged Cable/Wires/Lugs/Sockets Etc. By New One Of Following Types, Sizes And Ratings Frlsh/Hffr Pvc Insulated Single Core (Unsheathed) Bright Annealed Copper Conductor Multistrand Flexible Cable For Voltage Grade Up To 1100V As Per Is694:2010 I/C Laying / Drawing In Existing Conduit/Pipe, Connection, Testing Etc. As Required. , 25Sqmm With Copper Socketing At Both Ends , 16Sqmm With Copper Socketing At Both Ends , 10Sqmm With Copper Socketing At Both Ends , 1 X 6.0 Sq. Mm , 1 X 1.5 Sq. Mm , 2 X 1.5 Sq. Mm , 3 X 1.5 Sq. Mm , 2 X 4 Sq. Mm , 3 X 4 Sq. Mm , Replacement Of The Burnt-Out Cables/Wirings By The Following Sizes Fr Pvc Insulated & Pvc Round Sheathed Multicore Bright Annealed Bare Copper Conductor Flexible Cable For Voltage Grade Up To 1100Volts As Per Is-694-2010 I/C Fixing/Laying On Wall/Ceiling With C Cl S Etc. As Required. , 3 Corex1.5Sqmm , 3 Corex2.5Sqmm , 4 Corex2.5Sqmm , 3 Corex4.0 Sqmm , Supply Of The Following Sizes Pvc Insulated & Pvc Sheathed Aluminium Conductor Armoured Cable 650/1100 V. Grade Confirming To Is : 7098 (Part-1) 1988 I/C Transportation To Respective Sites Etc. As Required For Replacement Of Faulty/Burnt Out Cables. , 2 Core 6 Sqmm , 4 Core 10 Sqmm , 4 Core 16 Sqmm , 4 Core 25 Sqmm , 3.5 Core 50Sqmm , Replacement Of Damaged Mv Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. , 2 X 6 Sq. Mm (19Mm) , 4 X 16 Sq. Mm (28Mm) , 4 X 25 Sq. Mm (28Mm) , 3½ X 50 Sq. Mm (35Mm) , Replacement Of Faulty Service Connection Cables By New One Of 2 Core X 4Sqmm Pvc Insulated And Pvc Sheathed Aluminium Conductor Weather Proof Cable Etc. As Required. , Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Rcc/ Hume/ Metal Pipe As Required. , Up To 35Sqmm , Above 35 Sq. Mm And Up To 95 Sq. Mm , Laying And Fixing Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size On Wall Surface As Required. , Up To 35Sqmm , Above 35 Sq. Mm And Up To 95 Sq. Mm (Cl Ed With 25X3mm Ms Flat Cl ) , Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size Up To 35Sqmm Direct In Ground Including Excavation And Refilling The Trench Etc As Required, But Excluding Sand Cushioning And Protective Covering. , Up To 35Sqmm , Above 35 Sq. Mm And Up To 95 Sq. Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size Up To 35Sqmm In The Existing Duct/Air As Required. , Up To 35Sqmm , Above 35 Sq. Mm And Up To 95 Sq. Mm (Cl Ed With 25X3mm Ms Flat Cl ) , Replacement Of Faulty Sdfus/Sfus By New Ones Of Following Ratings Switch Disconnector Fuse Units (Sdfu) With Din Type Hrc Fuse Links (Open Execution Type) With Terminal Shrouds On Both Sides And Phase Barriers Included, Telescopic Shaft For Depth Adjustment Conforms To Iec 60947-3, Is/Iec 60947-3 (Open Execution Type) After Dismantling The Old Defective Sdfu/Sfu, Fixing Of The New One, Connection & Testing Etc. As Required. (Make: Lk Fn Type/Equivalent Model Of Siemens/Abb/Havells) . , 63 S 415 Volts Tpn Switch Disconnector Fuse Units (Sdfu) With Din Type Hrc Fuse Links , 100 S 415 Volts Tpn Switch Disconnector Fuse Units (Sdfu) With Din Type Hrc Fuse Links , Replacement Of Faulty Sdfus/Sfus By New Ones Of Following Ratings Switch Disconnector Fuse Units (Sdfu) With Hrc Fuse Links In Spacious Sheet Steel Enclosures, So That There Will Be No Need Of Separate Cable Gland Boxes, Having Terminal Shrouds And Phase Barriers On Both Sides Suitable For Cylindrical/Din Type Hrc Fuse Links, Confirming To Iec-60947-3, Is/Iec:60947-3, After Dismantling The Old Defective Sdfu/Sfu, Fixing Of The New One Connection & Testing Etc. As Required. (Make: Lk Fn Type/Equivalent Model Of Siemens/Abb/Havells) . , 63 S 415 Volts Tpn Sdfu In Sheet Steel Enclosure With Din Type Hrc Fuses , 100 S 415 Volts Tpn Sdfu In Sheet Steel Enclosure With Din Type Hrc Fuses , Replacement Of Faulty Change Over Switches By New Onload Type Change Over Switch Disconnector Of Following Ratings In Spacious Sheet Steel Enclosure So That There May Not Be Need Of Separate Cable End Boxes, Having Terminal Shrouds, Source Separator And Phase Barriers, Staggered Terminals Make Cable Termination Easy Conforms To Iec 60947-3, Is/Iec 60947-3), Suitable For Horizontal As Well As Vertical Mounting After Dismantling The Old Defective Ones, Fixing The New One, Connection & Testing Etc. As Required. (Make: Lk /Equivalent Model Of Siemens/Abb/Havells/Hpl-Socomec) . , 63 , 415V, 50Hz, 4-Pole , 100 , 415V, 50Hz, 4-Pole , 125 , 415V, 50Hz, 4-Pole , Replacement Of Faulty Mccbs By New Ones Of Following Ratings Conforming To Is/Iec 60947-2 & Iec 60947-2, Ics= 100% Of Icu, Adjustable Overload Settings: 0.8 - 1.0 X In, Fixed Short-Circuit Settings: 10 X In, Breaking Capacity 25Ka, Etc. After Dismantling The Old Defective Ones, Fixing This New Mccbs, Connection & Testing Etc. As Required. (Make-Lk Type- Dz0-125C /Equivalent Model Of Siemens/Abb) , 63 S 3 Pole 415 Volts 50 Hz , 63 S 4 Pole 415 Volts 50 Hz , 100 S 3Pole 415 Volts 50 Hz , 100 S 4Pole 415 Volts 50 Hz , Replacement Of Faulty And Damaged Ftl Fittings By New One Of Following Ratings, 65000K Cool Day Light Suitable For Operation On 140 Volts To 270 Volts Ac, 50Hz I/C Fixing And Connection Etc. As Required. , 20/22 Watt 65000K Led Batten Polycarbonate/Aluminium Body. (Make-(Philips Ujjwal 20-Watt Led Batten / Equivalent Model Of Surya / Polycab / Crompton) , 12 Watt 6500K Led Full Glow Metal Surface Round Light Fittings Minimum Luminous Efficacy - 100Lm/Watt (Make- Phillips/Equivalent Model Of Havells/Crompton) , 18 Watt 6500K Led Full Glow Metal Surface Round Light Fittings Minimum Luminous Efficacy - 100Lm/Watt (Make- Phillips /Equivalent Model Of Havells /Crompton) , 10Watt 6000K, 850Lumen Led Bulk Head Wall Light (Make- Phillips/ Havells/ Crompton) , 15/16W Led Bulb Suitable For B22 L Holder, Color Temperature: 6500K, Lumens: 1700Lm, Operating Voltage: 220-240 Volts, Low Energy Consumption And Non-Dimmable Type. , 30W Led Bulb (A19) , Crystal White, Energy Efficient, Operating Voltage: 220-240 Volts, Suitable For Indoor And Outdoor Use And Fixing In B22d Holder Etc. As Required. , Mounting Rail For Tled L S./ Led Tubes In Surface Suspended And Wall Mounted Led Batten Having Crca Housing Suitable For Operation On 140-270V 50Hz Ac Supply Including Connection , Testing Etc. As Required. (Make:Phillips, Model- Tmc 502 1Xt-Led 22W) , Mounting Rail For Tled L S./ Led Tubes In Surface Suspended And Wall Mounted Led Batten Having Crca Housing Suitable For Operation On 140-270V 50Hz Ac Supply Including Connection , Testing Etc. As Required. (Make:Phillips, Model-Tmc 502 2Xt-Led 22W) , 20W 4Ft Ultra Bright Led Tube Light With Very High Efficacy 2100Lumen, 6500K & Thd<15%, Single Side Wiring Suitable For Installation In Existing Flt Fixtures Having G13 L Holders In Replacement Of Conventional Fluorescent Tubes. Faulty Led Tubes I/C Connection Etc. As Required. (Make-Phillips/Bajaj/Crompton/Havells). , Replacement Of The L Holders/Ceiling Roses Etc. By New Ones Of Reputed Makes Etc. As Required. , Angle/Batten Holder , 36/40 W Fl Tube Light Holder , Ceiling Rose (3 Plate) , 5/6 S 250 Volts 3 Pin Plug Top , 15/16 S 250 Volts 3 Pin Plug Top , Supplying And Fixing Following Modular Type / Piano Type Switch/ Socket On The Existing Modular Plate/Switch Box Including Connections Etc. As Required. , 6/10 A One Way Modular Switch , 3 Pin 6/10 A Modular Socket , 16/20A Modular Switch , 6 Pin 16/20A Modular Socket , Modular Type Bell Push , 6 /10 S 1 Way Piano Type Switch , 20 S 1 Way Piano Type Switch , 6 S 3 Pin Piano Type Socket , 16 S 3 Pin Piano Type Socket , Supplying And Fixing Following Size/ Modules, Gi Box (At Least 1.2Mm Thick) Along With Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required. , 1 Or 2 Module (75 Mmx75 Mm) , 3 Module (100 Mmx75 Mm) , 4 Module (125 Mmx75 Mm) , 6 Module (200 Mmx75 Mm) , 8 Module (125 Mmx125 Mm) , 12 Module (200 Mmx150 Mm) , Carry Out Repairing Of Electrical Light Fittings By Arranging Qualified And Trained Man Power And Tools, Tackles, Ladders Etc. I/C Dismantling Of Defective/Faulty Components And Fixing Of New Components I.E Chokes, L S, Starters, Interconnection Wires, L Holders Etc. As Required. , Replacement Of Faulty And Unserviceable Ceiling Fan By New Ones Of 1200Mm Sweep, 3Nos Aluminium Blades, Isi Marked Minimum 1-Star Rated, Copper Wound Induction Motor, 350Rpm, Min Air Delivery 226M3/Min, Powder Coated With 260Mm Down Rod Suitable For Operation On 230V 50Hz Ac Supply I/C Installation, Connection And Testing Etc. As Required. (Havells Andria/Ambose Es/Artemis With 2 Years Warranty Or Equivalent Of Usha/Bajaj/Crompton) , Rewinding Of 1200Mm/1400Mm Ceiling Fan By Superior Quality Super Enameled Copper Conductor I/C Heat Varnishing, Testing Etc. As Required. , Overhauling Of Ceiling Fan I/C Dismantling, Heat Varnishing Of Windings, Greasing Of Bearings, Refitting, Testing Etc. As Required. , Replacement Of The Defective Capacitors / Fan Regulators/ Bearings For Ceiling Fans Etc. By The New One Of Following Ratings Etc. As Required. (Make- Anchor/Havells/Cona/Isi) , Stepped Type Electronic Fan Regulator (Switch Type) , Modular Fan Regulator (2 Modules) 5 Steps , Modular Fan Regulator (1 Module) , 2.25 Mfd 440 Volts Capacitor For Ceiling Fan , Bearings For Ceiling Fans (6201 & 6202) Etc. As Required. (Make: Skf/Ss) , Ceiling Fan Cl S Heavy Duty Mild Steel Zinc Golden Colour With Rubber (Shackle Set) , S/F Of Mcb Protected Socket Outlet 4 Module With Metal Box Comprising Of 01No. 25 S Socket And 01No. 25 S Plug And 01No. 25 S C Series Spmcb For Split Ac Units I/C Connection, Testing Etc. As Required. (Make- Legrand /Havells/Hpl/Standard) , Replacement Of Burn Out Sockets/Lugs Of Cables By New Ones Of Following Types And Sizes I/C Dismantling The Burnt Out Portion Of Cables/Wires, Crimping/Fixing Of New Sockets/Lugs Etc. (Dowells / Comet / Hex Connect Well / Ss) , For 16Sqmm Al Conductor Armoured Cable , For 25/35Sqmm Al Conductor Armoured Cable , For 50/70Sqmm Al Conductor Armoured Cable , Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. , 20Mm , 25Mm , 32Mm , Supplying And Fixing Following Way, Horizontal Type Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 V, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/ Isolator). (Make-Legrand/L&T/Siemens/Schneider) , 4 Way (8 + 12) With Metal Door (Ip43) , Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) (Make-Legrand/L&T/Siemens/Schneider) , 8 Way With Metal Door (Ip43) , 12 Way With Metal Door (Ip43) , Supply And Fixing Of Following Watt Led Street Light Fitting Delivering >100 Lumen/Watt With Pdc Housing And Street Light Optics To Ensure Uniform Distribution Having Bottom Opening Separate Driver Compartment With Ip66 Protection And Impact Resistance Of Ik08.. , 30 Watt (Make-Phillips Model Brp030 P Led35 Cw Slr Gr Psu Spd/Equivalent Model Of Havells/Crompton) , 45 Watt (Make-Phillips Model Brp031 Led45 Cw Slr Gr Psu Spd/Equivalent Model Of Havells/Crompton) , Replacement Of Damaged Loop In And Loop Out Boxes By Smc Junction Box Of Size 103Mm X 103Mm X 70Mm (Inside Dimensions) With Hinged Door Type Including Supply And Fixing Of 1No. 2 Pole Stud Connector With Nuts And Bolts Etc. As Required. (Sintex Gsjb1111/Ss) , Supply And Fixing Of Smc Junction Box Of Size 200Mm X 140Mm X 95Mm (Inside Dimensions) With Hinged Door Type Including Supply And Fixing Of 1No. 4 Pole Stud Connector With Nuts And Bolts Etc. As Required. (Sintex Gsjb2014/Ss) , Repairing Of Compound Light By Dismantling The Old Damaged Fitting From The Pole By Arranging Of Ladder, Skill Manpower And Fixing Of New Led Fitting I/C Rewiring From Loop Box To Led Fitting If Required Etc Complete As Required. , Supplying & Drawing Of 12 Swg Gi Insulated Wire For Stringing Of Service Cable On Overhead Etc As Required. , Replacement Of Damaged Compound Light Brackets By 32 Mm Dia X 1.2Metres Long G.I. Pipe (Medium Class) Bracket Along With 2 Nos. 32M Gi Cl S With Nuts, Bolts And Washers For Mounting Of Street Light Fitting On Pole Including Bending The Pipe To The Required Shape Etc. Including Cost Of All Materials As Required. , Supply Of Hot Pressed Molded Smc Junction Box, Hinged Double Door Type Of Following Sizes Suitable For Application For Fixing Electrical Controls /Switch Gears/Meters Etc. With Provision For Cable Entry/Exit From Bottom/Side , Locking Arrangements Including Supply And Fixing Of 2Nos 4 Pole Stud Connectors, Interconnections With Suitable Size Single Core Pvc Insulated Copper Conductor Cable With Copper Sockets/Lugs Including Fixing On Existing Pole / Existing Ms/Gi Angle Stands Etc. Complete As Required. , Size Not Less Than 650Mmx350mmx250mm (Inside Dimensions) (Make-Sintex Model: Sintex Jb-6535/Ss) , Size Not Less Than 400Mmx300mmx190mm (Inside Dimensions) (Make-Sintex Model: Sintex Jb-4030/Ss) , Making Suitable Angle Base Frame Made Of 40Mmx40mmx5mm Ms Angle For Installation Of Mentioned Smc Junction / Meter Boxes , Cutting, Welding, Fabricating, Grouting The Same On Ground With Required Pcc Work Complete As Required. , Liaison With The Electricity Discoms For Taking Shutdown Of Lt/Mv Lines For Checking, Testing And Replacement Of Faulty Service Connection Cable/Energy Meter/ Meter Box/Feeder Panel Etc. And Re Energization Of Power Supply After Replacement Of Faulty Components As Above / Removal Of Faults Etc. Complete As Required.
Basic Detail
Tender No GEM/2026/B/7869269
Bidding Type Tender
Location
City Khordha
State Odisha
Key Dates
Publish Date 03 Aug 2026
Submission Date 14 Aug 2026
Open Date 14 Aug 2026
Finance
Tender Value 19.40 Lakhs
Tender Fee Ref. Documents
EMD 38808
Exemption Not Available
Document List
80546ad8-f23b-4037-a9aa-8fa04fe774de.pdf
1785749515.xlsx
1785749532.pdf
1785749538.pdf
ATC_227bbd72-6728-4b1a-b27e1785749836909_pareshsahoo.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 14, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Aug 14, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
pdf

80546ad8-f23b-4037-a9aa-8fa04fe774de.pdf

xlsx

1785749515.xlsx

pdf

1785749532.pdf

pdf

1785749538.pdf

pdf

ATC_227bbd72-6728-4b1a-b27e1785749836909_pareshsahoo.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders