Power Government Departments Closing in 0 days TDR #56809959

Tender For Eelectrification Work At Various Govt. Schools In Manjeri Municipality Under Annual Plan (Project No. 1356/26)

Issued by Government Departments · Malappuram, Kerala
Tender Value
11.31 Lakhs
Estimated cost
Bid Submission
10 Aug 2026
0 days left
EMD
28287
Bank guarantee accepted
Document Fee
2950
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Malappuram → Kerala
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Eelectrification Work At Various Govt. Schools In Manjeri Municipality Under Annual Plan (Project No. 1356/26)

BOQ

Name of Work:- EElectrification Work at various Govt. Schools in Manjeri Municipality under Annual Plan (Project No. 1356/26)
Sl. No. Item Description
1GMLP School, Manjeri East (Kizhakkethala)
21.10.3Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mmFRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
31.55.3Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bellpoint ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copperconductor single core cable in surface/ recessed PVC conduit, and earthing the pointwith 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. asrequired.Group C
490.3.21.3Supply & installation of light fittings on 'C/U' shaped flat iron bracketSupply, conveyance, installation, testing and commissioning the light fittings offollowing types made from 0.5mm CRCA sheet complete with all accessories andlamps etc. directly on wall using 2 nos. 'C/U' brackets made from 20 x 3 mm MS flat,painting the flat iron bracket and giving connections with required length of16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS orextending the original wiring and giving connection etc. as required.1200 mm1X20W LED Lamp with box type fixture
590.3.20.3Supply & installation of light fittings on TW round blockSupply, conveyance installation testing and commissioning the light fittings offollowing types made of CRCA with 0.5mm thickness complete with all accessoriesand lamps etc. directly on wall or ceiling with PVC round block neatly painted to suitthe fitting and giving connection with required length of 16/0.20mm 3 core copperconductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture
690.15.4.5Supply Conveyance, installation, testing and commissioning of 40W LED Flood lightoutput greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip makeCree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surgeprotection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than10%, power factor greater than 0.98, RoHScompliant, duly wired up for use on 230 V AC supply. Driver compartment should beseperatly accessible for maintenance (LM 79&80 certificates from NABLaccredited Third party lab to be produced mentioning chip manufacturer)
790.15.4.7Supply Conveyance, installation, testing and commissioning of 100W LED Floodlight output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chipmake Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internalsurge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98,RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartmentshould be seperatly accessible for maintenance (LM 79&80 certificates fromNABL accredited Third party lab to be produced mentioning chip manufacturer)
8OD77792/2026-2027Supply, conveyance, installation, testing and commissioning of 9/10W LED Bulkhead light fittings directly on wall including giving connections with required lengthof 16/0.20mm 3 core round copper conductor flex wire conforming to relevant ISSmaking good the damages, colour washing etc as required.
91.58Supplying and fixing PVC batten/ angle holder including connection etc. as required.
10OD77809/2026-2027Supplying and fixing 9W LED Bulb. as required
11OD94563/2026-2027Supply, installation, testing and commissioning of 1200 mm sweep BEE-5 star ratedceiling fan with brushless direct current motor (BLDC) , class of insulation B , 3 no'sblades , 30 cm long down rod , 2no:s canopies, shackle kit, safety rope , copperwinding, power factor not less than .9, service value (CM/M/W) minimum 6.00, Airdelivery minimum 210 cum/min,350 RPM (tolerance as per IS :374-2019, THD lessthan 10% remote or electronic regulator unit for speed control and all remainingaccessories including safety pin, nut and bolts , washers, temperature rise equal to 75deg celsius (maximum) , insulation resistance more than 2 Megaohm , suitable for 230V,50 Hz, single phase AC supply , earthing etc., complete as required:
121.25Supplying and fixing two module stepped type electronic fan regulator on the existingmodular plate switch box including connections but excluding modular plate etc. asrequired
1390.4.1Supply and installation of suitable size MS rod type fan clamp in the RCC slab as perIS 732 as required.
1490.5.1.9Supply and fixing the following types of superior quality 250V A.C call bell onexisting M.S. box and giving connections with required length of 3 core, 16 / 0.20mm650/1100V grade PVC insulated and PVC sheathed round copper conductor flex wireconforming to relevant ISS or with the extended original wiring, earthing the MS boxand making good the surface as required.Gong bell 225mm-without MS box
151.33Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ woodenblock including connection etc as required.
161.31Supplying and fixing suitable size GI box with modular plate and cover in front onsurface or in recess, including providing and fixing 3 pin 5/6 amps modular socketoutlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to beused in non residential buildings).
1790.10.1.2Supply & Fixing the following types/ sizes of boxes suitable for modularaccessories in surface/ recess including making good the damages, colour washing etcas required (RoHS compliant )2 module moulded plastic box on surface
181.28.1Supplying and fixing following Modular base & cover plate on existing modularmetal boxes etc. as required.1 or 2 Module
191.27.2Supplying and fixing following size/ modules, GI box alongwith modular base &cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
201.27.4Supplying and fixing following size/ modules, GI box alongwith modular base &cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
211.24.1Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.5/6 amps switch
221.24.3Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.15/16 amp switch
231.24.4Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. as required.3pin 5/6 amp socket outlet
241.24.5Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. as required.6pin 15/16 amp socket outlet
2590.10.3.15Supply and Fixing the following modular switches & accessories in the existing frontplates and giving necessary connections as required (RoHS compliant )32A DPswitch with indicator
2690.11.1.14Supply and installation of sheet steel, phosphatised and painted, dust and verminproof enclosure of MCB DB including copper /brass bus bar, neutral link, earth busand DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitableanchor bolts or fixed in recess including cutting hole on the wall , making good thedamages, colour washing etc. as required4 way (8+12) - double cover TPN verticalDB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/TP MCB as outgoing (IP 42/43)
272.3.2Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)8 way, Double door
282.3.3Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)12 way, Double door
292.10.1Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole
302.12.1Supplying and fixing following rating, double pole, 240 volts, isolator in the existingMCB DB complete with connections, testing and commissioning etc. as required.40amps
312.13.2Supplying and fixing following rating, four pole, 415 volts, isolator in the existingMCB DB complete with connections, testing and commissioning etc. as required.63amps
322.14.2Supplying and fixing following rating, double pole, (single phase and neutral),240volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milliamperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.40 amps
332.15.3Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.63 amps
341.17.2Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x1.5 sq. mm
351.17.3Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X1.5 sq.mm
361.17.4Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x1.5 sq. mm
371.17.6Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x1.5 sq. mm
381.17.9Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.9 x1.5 sq. mm
391.17.12Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x2.5 sq. mm
401.17.21Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x4 sq. mm
411.17.24Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x4 sq. mm
421.21.1Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
431.21.2Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same in
445.4Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick includingaccessories, and providing masonry enclosure with cover plate having lockingarrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt asrequired.
45OD77828/2026-2027Supply and providing 25 x 6mm brass bolt
46OD77829/2026-2027Providing and fixing 25 mm X 3 mm G.I. strip earth lead from the test joint to theearth plate
47OD77842/2026-2027Providing and fixing 2 X 25 mm X 3 mm G.I. strip test joint for earthing system
4890.16.1.3Supply and drawing bare earthing conductors of the following sizes along withwiring/ cables and giving connection as required3.15 mm copper conductor ( 10SWG)
4990.16.5.3Supply of superior quality copper earth socket for the following size of earthconductor including crimping etc. as required.3.15 mm (10 SWG)
50OD77838/2026-2027Supplying and fixing 32 A, 2 Way neutral links mounted on DMC/SMC base withconnections, in existing meter board
51OD77839/2026-2027Supplying and fixing 32A, HRC Fuse with HRC Fuse link with connections, inexisting meter board
52OD77840/2026-2027Supply and installation of 32 A, 415 V, 50 Hz, AC 23 A duty, TPN SDF units insheet steel enclosure complete with handle assembly, door interlock and pad locking arrangement of the following ratings on existing angle iron frame work or directly to wall using necessary bolts & nuts, fixing the unit to wall, making good the damages, colour washing etc. including giving necessary connections as required
53OD77834/2026-2027Supply & installation of dust and vermin proof, 3 Phase Syntax Meter Board(GSMB6545) and to fix KSEB meters, fuse units etc as required including fixing it onwall, making good the damages colour washing etc. as required.
54OD77833/2026-2027"Supply and fixing of 32/40mm PVC pipe along with accessorie sin surfaceincluding cutting the wall and making good the same for KSEB Service pipe"
55OD77841/2026-2027Supply and providing suitable Iron Hook Grouted on wall for binding the service wire
56OD83155/2026-2027Supply, installation, testing and commissioning of wall-mounted Public Address (PA)speaker of approved make such as Ahuja WSX-681T, WSX-551T or equivalent,suitable for indoor PA applications. The speaker shall be fitted with an inbuilt 100Vline matching transformer with 6W RMS power output and multi-tap facility(6W/3W/1.5W), suitable for operation on a 100V distributed speaker line. Thespeaker shall have a frequency response of 60 Hz to 15 kHz, minimum sensitivity of90 dB (1W/1m), nominal impedance corresponding to the selected power tap, andshall be housed in a robust, aesthetically finished ABS/metal enclosure suitable forwall mounting. The item shall be supplied complete with wall mounting bracket,fixing hardware, terminals and all necessary accessories. The work shall includefixing the speaker firmly on the wall, making electrical connections to the existing PAsystem using suitable PVC insulated copper cable, testing for clear and distortion-free sound reproduction, and commissioning the system complete as required and as directed by the Engineer-in-Charge.
57OD83166/2026-2027Preparation and submission of test report to KSEB Ltd. for obtaining new LT serviceconnection, additional connected load, or meter replacement, including testing of theinternal electrical installation, preparation of required documents, submission of thetest report, and liaison with KSEB Ltd. officials, complete as required. (ExcludingKSEB statutory fees and demand charges.)
58GMLP School, Mangalasseri ( GMLP School, Palakkulam and GMLP School,Chundayil)
591.10.3Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mmFRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earth
6090.3.20.3Supply & installation of light fittings on TW round blockSupply, conveyance installation testing and commissioning the light fittings offollowing types made of CRCA with 0.5mm thickness complete with all accessoriesand lamps etc. directly on wall or ceiling with PVC round block neatly painted to suitthe fitting and giving connection with required length of 16/0.20mm 3 core copperconductor flex wire conforming to relevant ISS and giving connections asrequired.1200 mm 1X20W LED Lamp with box type fixture
6190.3.21.3Supply & installation of light fittings on 'C/U' shaped flat iron bracketSupply, conveyance, installation, testing and commissioning the light fittings offollowing types made from 0.5mm CRCA sheet complete with all accessories andlamps etc. directly on wall using 2 nos. 'C/U' brackets made from 20 x 3 mm MS flat,painting the flat iron bracket and giving connections with required length of16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS orextending the original wiring and giving connection etc. as required.1200 mm1X20W LED Lamp with box type fixture
621.58Supplying and fixing PVC batten/ angle holder including connection etc. as required.
63OD83181/2026-2027Supplying and fixing 9W LED Bulb. as required
6490.15.4.5Supply Conveyance, installation, testing and commissioning of 40W LED Flood lightoutput greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip makeCree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surgeprotection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than10%, power factor greater than 0.98, RoHScompliant, duly wired up for use on 230 V AC supply. Driver compartment should beseperatly accessible for maintenance (LM 79&80 certificates from NABLaccredited Third party lab to be produced mentioning chip manufacturer)
65OD94564/2026-2027Supply, installation, testing and commissioning of 1200 mm sweep BEE-5 star ratedceiling fan with brushless direct current motor (BLDC) , class of insulation B , 3 no'sblades , 30 cm long down rod , 2no:s canopies, shackle kit, safety rope , copperwinding, power factor not less than .9, service value (CM/M/W) minimum 6.00, Air delivery minimum 210 cum/min,350 RPM (tolerance as per IS :374-2019, THD lessthan 10% remote or electronic regulator unit for speed control and all remainingaccessories including safety pin, nut and bolts , washers, temperature rise equal to 75 deg celsius (maximum) , insulation resistance more than 2 Megaohm , suitable for 230V,50 Hz, single phase AC supply , earthing etc., complete as required:
661.25Supplying and fixing two module stepped type electronic fan regulator on the existingmodular plate switch box including connections but excluding modular plate etc. asrequired.
6790.4.1Supply and installation of suitable size MS rod type fan clamp in the RCC slab as perIS 732 as required.
681.33Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ woodenblock including connection etc as required.
691.31Supplying and fixing suitable size GI box with modular plate and cover in front onsurface or in recess, including providing and fixing 3 pin 5/6 amps modular socketoutlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
7090.10.1.2Supply & Fixing the following types/ sizes of boxes suitable for modularaccessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )2 module moulded plastic box on surface
711.28.1Supplying and fixing following Modular base & cover plate on existing modularmetal boxes etc. as required.1 or 2 Module
721.27.2Supplying and fixing following size/ modules, GI box alongwith modular base &cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
7390.10.1.3Supply & Fixing the following types/ sizes of boxes suitable for modularaccessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )3 module moulded plastic box on surface
741.28.2Supplying and fixing following Modular base & cover plate on existing modularmetal boxes etc. as required.3 Module
751.27.4Supplying and fixing following size/ modules, GI box alongwith modular base &cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
761.24.1Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.5/6 amps switch
771.24.3Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.15/16 amp switch
781.24.4Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.3 pin 5/6 amp socket outlet
791.24.5Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.6 pin 15/16 amp socket outlet
8090.10.3.15Supply and Fixing the following modular switches & accessories in the existingfront plates and giving necessary connections as required (RoHS compliant )32A DPswitch with indicator
812.3.1Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)6 way, Double door
822.3.2Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)8 way, Double door
832.3.3Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)12 way, Double door
842.10.1Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole
852.11Supplying and fixing single pole blanking plate in the existing MCB DB completeetc. as required.
862.12.1Supplying and fixing following rating, double pole, 240 volts, isolator in the existingMCB DB complete with connections, testing and commissioning etc. as required.40amps
872.14.2Supplying and fixing following rating, double pole, (single phase and neutral),240volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milliamperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.40 amps
881.17.3Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x1.5 sq. mm
891.17.6Supplying and fixing 32A, HRC Fuse with HRC Fuse link with connections, inexisting meter board
901.17.12Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
911.17.21Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x4 sq. mm
921.21.1Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
9390.12.5.3Supply & laying of one number PVC insulated and PVC sheathed armouredaluminium power cable of 1.1KV grade of the following sizes in the existing RCC/HUME / STONE WARE/ GI/ DWC pipe as required.2 core 10 sq mm
9490.12.7.3Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armouredaluminium power cable, 1.1 KV grade of the following sizes using clamps notedalong with the cables, spacing of clamps not exceeding 60cms, making good thedamages , colour washing etc. as required.2 core 10 sq mm with factory made clamp
959.1.2Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm)
9690.12.9.2Supplying, laying and jointing of the following sizes of double wall corrugated(DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanicalprotection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size
9790.12.10.2Supply & laying of DWC pipe in ordinary soil 0.75m below ground levelincluding excavation50/38 mm or nearest size
985.4Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick includingaccessories, and providing masonry enclosure with cover plate having lockingarrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt asrequired
99OD83409/2026-2027Providing and fixing 2 X 25 mm X 3 mm G.I. strip test joint for earthing system
100OD83413/2026-2027Providing and fixing 25 mm X 3 mm G.I. strip earth lead from the test joint to theearth plate
101OD83747/2026-2027Supply and providing 25x6mm brass bolt
10290.16.1.3Supply and drawing bare earthing conductors of the following sizes along withwiring/ cables and giving connection as required3.15 mm copper conductor ( 10SWG)
10390.16.5.3Supply of superior quality copper earth socket for the following size of earthconductor including crimping etc. as required.3.15 mm (10 SWG)
104OD83418/2026-2027Supply & installation of dust and vermin proof, 1 Phase Syntax Meter Board(GS-MB- 3525) and to fix KSEB meters, fuse units, CT etc as required includingfixing it on wall, making good the damages colour washing etc. as required.
105OD83411/2026-2027Supplying and fixing 32 A, 2 Way neutral links mounted on DMC/SMC base withconnections, in existing meter board
106OD83412/2026-2027Supplying and fixing 32A, HRC Fuse with HRC Fuse link with connections, in existing meter board
107OD83410/2026-2027Supply and providing suitable Iron Hook Grouted on wall for binding the service wire
108GMLP School, Thottupoyil
1091.10.3Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mmFRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
11090.3.21.3Supply & installation of light fittings on 'C/U' shaped flat iron bracketSupply, conveyance, installation, testing and commissioning the light fittings offollowing types made from 0.5mm CRCA sheet complete with all accessories andlamps etc. directly on wall using 2 nos. 'C/U' brackets made from 20 x 3 mm MS flat,painting the flat iron bracket and giving connections with required length of16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS orextending the original wiring and giving connection etc. as required.1200 mm1X20W LED Lamp with box type fixture
111OD94565/2026-2027Supply, installation, testing and commissioning of 1200 mm sweep BEE-5 star ratedceiling fan with brushless direct current motor (BLDC) , class of insulation B , 3 no'sblades , 30 cm long down rod , 2no:s canopies, shackle kit, safety rope , copperwinding, power factor not less than .9, service value (CM/M/W) minimum 6.00, Airdelivery minimum 210 cum/min,350 RPM (tolerance as per IS :374-2019, THD lessthan 10% remote or electronic regulator unit for speed control and all remainingaccessories including safety pin, nut and bolts , washers, temperature rise equal to 75 deg celsius (maximum) , insulation resistance more than 2 Megaohm , suitable for 230V,50 Hz, single phase AC supply , earthing etc., complete as required:
1121.25Supplying and fixing two module stepped type electronic fan regulator on the existingmodular plate switch box including connections but excluding modular plate etc. asrequired.
11390.4.2Supply and installation of suitable size MS belt type fan clamp fabricated from flatiron 40 x 6 mm, 150mm long x 2 Nos with M.S. rod bent to shape, neatly paintedwith 2 coats of enamel paint over a coat of red oxide primer as per IS 732 as required.
1141.33Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ woodenblock including connection etc as required.
1151.31Supplying and fixing suitable size GI box with modular plate and cover in front onsurface or in recess, including providing and fixing 3 pin 5/6 amps modular socketoutlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
11690.10.1.2Supply & Fixing the following types/ sizes of boxes suitable for modularaccessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )2 module moulded plastic box on surface
1171.28.1Supplying and fixing following Modular base & cover plate on existing modularmetal boxes etc. as required.1 or 2 Module
1181.27.4Supplying and fixing following size/ modules, GI box alongwith modular base &cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
1191.24.1Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.5/6 amps switch
1201.24.4Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.3 pin 5/6 amp socket outlet
1212.3.2Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way, Double door
1222.10.1Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole
1232.12.1Supplying and fixing following rating, double pole, 240 volts, isolator in the existingMCB DB complete with connections, testing and commissioning etc. as required.40amps
1242.14.2Supplying and fixing following rating, double pole, (single phase and neutral),240volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milliamperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required. 40 amps
1251.17.3Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1261.17.6Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x1.5 sq. mm
1271.17.21Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x4 sq. mm
1281.21.1Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56809959
AUTHORITY Government Departments
TENDER VALUE 11.31 Lakhs
LAST DATE 10-08-2026
Authority
Authority Name Kerala Electrical And Allied Engineering Co Limited
Work Description Tender for Eelectrification Work At Various Govt. Schools In Manjeri Municipality Under Annual Plan (Project No. 1356/26)
Basic Detail
Tender No KEL/ KEMG/85C/2026-27
Bidding Type Tender
Location
City Malappuram
State Kerala
Key Dates
Publish Date 03 Aug 2026
Submission Date 10 Aug 2026
Open Date 11 Aug 2026
Finance
Tender Value 11.31 Lakhs
Tender Fee 2950
EMD 28287
Exemption Available
Document List
682eacf6-5d27-4458-96db-ec8687de3069.html
BOQ_1461638.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 10, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Today
Aug 11, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 1 day

Tender Documents

Download All (ZIP) ↓
html

682eacf6-5d27-4458-96db-ec8687de3069.html

xls

BOQ_1461638.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders