Educational and Research Institute Boards / Undertakings / PSU Closing in 0 days TDR #56809324

Tender For Urgent Electrical Modification Required For Operationalisation Of Autoclave Room No. 632, Department Of Virology, Pgimer, Chandigarh. (Electrical Work).

Issued by Boards / Undertakings / PSU · Chandigarh, Chandigarh
Tender Value
1.84 Lakhs
Estimated cost
Bid Submission
08 Aug 2026
0 days left
EMD
3700
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Urgent Electrical Modification Required For Operationalisation Of Autoclave Room No. 632, Department Of Virology, Pgimer, Chandigarh. (Electrical Work).

BOQ

Name of Work:- Urgent Electrical Modification required for Operationalisation of Autoclave Room no. 632, Department of Virology, PGIMER, Chandigarh. (Electrical Work).
Sl. No. Item Description
1Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
220 mm
325 mm
4Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
5Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
66 Module (200mmX75mm)
7Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
85/6 A switch
915/16 A switch
103 pin 5/6 A socket outlet
116 pin 15/16 A socket outlet
12Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
13Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
143 X 1.5 sq.mm
153 X 4 sq.mm
16Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K 6500°K (As per ANSI Bin), SDCM(Standard Deviation
17Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. omplete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
18Powder coated die cast /Extruded aluminiumBody (Thickness > 1.20 mm)
1918- 22 Watt
20Supplying, Installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round / square/ Rectangular) COB Type of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have...
21... its own in house NABL lab setup for all testing facilities for LED fixtures. \\"complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector
2212 -15 watt
23Installation, Testing and Commissioning of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
24Upto 450 mm sweep
25Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
26Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
27Upto 35 sq. mm (clamped with 1mm thick saddle)
28Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
294 X 10 sq. mm (25mm)
30Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top along with 30 A \\"C\\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete withconnections, testing and commissioning etc. as required.
31SITC of 450 mm. 1440rpm, heavy-duty, wall fan, industrial-grade air circulator. Featuring a robust all-metal build. The fan should be complete in all respect and upto entire satisfaction of EIC.
32Supply of 300mm, 900 RPM heavy duty exhaust fan including louvers and frame complete in all respect as required at site up to entire satisfaction of EIC.
33Supplying of following size and core of Copper Conductor Balance Stranded Conductor, XLPE Insulated, Cores Laid Up, PVC Innersheathed, Armoured, Extruded PVC Type ST2 Outer Sheathed, 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments.
3410 sq.mm, 4 core
35Rebate on old FTL LED fixtures 25 Nos Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56809324
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 1.84 Lakhs
LAST DATE 08-08-2026
Authority
Authority Name Post Graduate Institute Of Medical Education And Research
Work Description Tender for Urgent Electrical Modification Required For Operationalisation Of Autoclave Room No. 632, Department Of Virology, Pgimer, Chandigarh. (Electrical Work).
Basic Detail
Tender No PGI/Engg/Elect/AEV/2026-27/03
Bidding Type Tender
Location
City Chandigarh
State Chandigarh
Key Dates
Publish Date 03 Aug 2026
Submission Date 08 Aug 2026
Open Date 10 Aug 2026
Finance
Tender Value 1.84 Lakhs
Tender Fee Ref. Documents
EMD 3700
Exemption Available
Document List
23bde6f7-e395-437b-a845-065a30558a6b.html
BOQ_967129.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 08, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Today
Aug 10, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
html

23bde6f7-e395-437b-a845-065a30558a6b.html

xls

BOQ_967129.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders