Agriculture Boards / Undertakings / PSU Closing in 0 days TDR #56809319

Tender For Improvement To Security Lighting At Peripheral Of The Depot Complex At Fsd Ratnagiri

Issued by Boards / Undertakings / PSU · Ratnagiri, Maharashtra
Tender Value
12.50 Lakhs
Estimated cost
Bid Submission
12 Aug 2026
0 days left
EMD
25100
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ratnagiri → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Improvement To Security Lighting At Peripheral Of The Depot Complex At Fsd Ratnagiri

BOQ

Name of Work:- Improvement to Security Lighting at peripheral of the Depot Complex at FSD Ratnagiri
Sl. No. Item Description
1Supplying of XLPE insulated & PVC tape innersheathed aluminium conductor armoured cable of 1.1 KV grade of following size confirming to IS:7098 (Part- I) 1988 with up to date ammendment as required.
23 x 10 sq. mm
3Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
463 mm dia (OD-63 mm & ID-51 mm nominal)
5Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
6Upto 35 sq. mm (clamped with 1mm thick saddle)
7Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
8Upto 35 sq. mm
9Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required
10100 mm dia
11Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required.
12Supplying of Hot-Dip Galvanized (HDG) Octagonal Pole of 7.0 Metre total height, with a Single Arm (SA) Sword type bracket of 1.0 Metre outreach, having a continuous taper profile with nominal dimensions of 70 mm across flats at the top and 130 mm across flats at the bottom, fabricated from 3 mm thick high-grade steel, with single longitudinal automatic welding, without any circumferential joint. The pole shall be hot-dip galvanized internally and externally in a single dip. Complete with an integrated weather-proof flush service door with specialized locking arrangements, two internal earthing terminals, a base plate of dimensions 220 mm x 220 mm x 16 mm (Hole size 24x45 mm, PCD 207 mm) conforming to IS 2062, required size of foundation J-bolts (4 Nos. M20 x 600 mm), and template, complete as per CPWD specifications along with erecting the same on existing foundation.
13Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
14All kinds of soil.
15Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
161:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
17Centering and shuttering including strutting, propping etc. and removal of form for
18Foundations, footings, bases of columns, etc. for mass concrete
19Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
201:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
21Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
22Thermo-Mechanically Treated bars of grade Fe-500D or more.
23Providing and fixing weather proof loop in loop out box of size not less than 300 mm X 200 mm X 105 mm at the bottom of pole/wall/ on truss of godown of PVC sheet with hinged cover and locking arrangement and providing and fixing links (HD connector) for termination of cables and one no. SPMCB 6 amps etc. complete including connections fixing of cable on pole/wall/truss with MS clamps etc. as required
24Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
253 X 10 sq. mm (22mm)
26LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
2750 watt
28Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required
29Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
303 x 1.5 sq. mm
31Supplying and fixing 5 A to 32 A rating, 240/415 V, 10kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
32Double pole (32A)
33Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required.
34Supplying, Installation, Testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required.
352 output per phase and suitable for single phase supply
36Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required.
37Applying priming coat:
38With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works
39Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :
40One or more coats on old work Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56809319
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 12.50 Lakhs
LAST DATE 12-08-2026
Authority
Authority Name Food Corporation Of India
Work Description Tender for Improvement To Security Lighting At Peripheral Of The Depot Complex At Fsd Ratnagiri
Basic Detail
Tender No 05/EE/2026-27
Bidding Type Tender
Location
City Ratnagiri
State Maharashtra
Key Dates
Publish Date 03 Aug 2026
Submission Date 12 Aug 2026
Open Date 13 Aug 2026
Finance
Tender Value 12.50 Lakhs
Tender Fee Ref. Documents
EMD 25100
Exemption Not Available
Document List
78440ea0-2624-4b61-b923-72f7c10fea05.html
BOQ_967131.xls
MTF.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 12, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Today
Aug 13, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 1 day

Tender Documents

Download All (ZIP) ↓
html

78440ea0-2624-4b61-b923-72f7c10fea05.html

xls

BOQ_967131.xls

pdf

MTF.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders