Tender For Repair And Maintenance Of Eot Crane, Fire Alarm & Detection System In Technical Area At Defence Lab Jodhpur
Tender Value
9.52 Lakhs
Estimated cost
Bid Submission
27 Aug 2026
4 days left
EMD
19040
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jodhpur → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair And Maintenance Of Eot Crane, Fire Alarm & Detection System In Technical Area At Defence Lab Jodhpur
BOQ
| Sl. No. | Item Description |
| 1 | Supply, installation,commissioning and testing for replacement of repeater panel of 12 zonal fire alarm panel confirming to IS 2119 and totally enclosed dust and vermin proof and shall be completely solid state design on wall /floor mounting made out of 16 gauge(1.6mm thick) MS sheet& MS frame as per existing make consist of followoing :(a) Visual and audio indication of fire for each zone indpendently. (b) Provision to sound all the sirens when fire breake out. (c ) Visual indication for clear healthy & fault less circuit(d) Facility to indicate failure of indicating lamps of the circuit by visual & audio alarm different from fire alarm.(e) Battery unit of supply 24 volts DC to system with acumulator of suitable capacity and automatic charging arrangement on AC and complete with Voltmeter and Ammetter etc of suitable ranges and battery charger (02 Nos of battery of 12volt 7 AH) complete all as specified and directed by engineer-in- chargeMake :- Honeywell, Agni, GST, Morley, Edward (Edward-Honeywell), Notifier, Bosch, Fire Lite, Simplex, and Ravel. |
| 2 | All as per item No 01 but 08 Zonal fire alarm panel as per existing make at site including complete connections with master control panel all as specified and directed by engr-in-charge. |
| 3 | All as per item No 01 but 4 Zonal fire alarm panel as per esisting make at site including complete connections with master control panel all as specified and directed by engr-in-charge. |
| 4 | All as per item No 01 but 2 Zonal fire alarm panel as per esisting make at site including complete connections with master control panel all as specified and directed by engr-in-charge. |
| 5 | M&L for replacement of single run of PVC FRLS insulated 1100Volt grade rounded twin core sheathed copper conductor of size 1.5 sqmm drawn through with rigid PVC conduit of 25mm dia fixed on wall /ceiling, 0.75mm dia copper earth continuity conductor to common earth and connected earth dolly including connecting with ionisation type smoke detector and fire alarm junction box complete with testing after the connection has made all as per specified and directed by Engineer-in-charge. Note- PVC conduit shall be measured and paid separately. |
| 6 | Supply and fixing in replacment of Rigid non metallic PVC conduict exclusive of boxes but included of all tees, bends,elbow, reducers, bell mouth tubes ends and fixing accessories such as couplers lock nuts saddles pipe hooks etc of 25mm dia all as specified and directed by engr-in charge. |
| 7 | Supply and fixing in replacement dual smoke detector of solid state design with dual ionisation chamber solid radio active sense response indicator lamps mounting base and Junction box for fixing etc completed all as specified and directed by engr-in-charge. Make :- Apollo, Siemens, GST, Honeywell |
| 8 | Supply and fixing in replacement conventional type multisensor detector with heat and smoke combination including indicator lamps mounting base and Junction box for fixing etc all as specified and directed by engineer-in-charge. |
| 9 | S&F in replacement Response Indicator unit of size 90mmx65mmx50mm all as specified and directed by engr-in-charge. |
| 10 | S&F in replacement Manual call point(resettable type) 145mmx90mmx50mm all as specified and directed by engr-in-charge. |
| 11 | S&F Break glass unit Rectangular in shape of size 145 mm x 90 mm glass of 3 mm thick complete all as specified and directed by engineer-in-charge |
| 12 | Supply fixing ,commsioning and testing of Fire alarm Siren/sounder system box all as specified and directed by Engr-in-charge. |
| 13 | Supply and fixing 12 V, 7 AH Battery complete all as specified and directed by Engineer-in-charge. |
| 14 | M&L for repairs of 2/4/8/12 zonal fire alarm panel of make Honeywell/ Agani with internal wiring, motherboard indicating lamps,LCD screen including connection etc and testing complete all as specified and directed by Engineer-in-charge. |
| 15 | M&L for painting of hose box externaly with two coats of FIRE RED colour and brilliant white inside yard over of red oxide primer as per IS 5:2007 shade 536 complete all as specified and directed by the Engineer-in -Charge |
| 16 | Supply and fix in replacement ABC Powder MAP90 fire extanguiser 06 kg including fire extanguiser bracket strap complete all as specified and directed by engineer-in-charge. |
| 17 | M&L for Hose box made of 18 gauge MS Sheet800mm X 600mm X 250mm with doubledoor with 4 mm thick glasses and doorframe made of 16 gauge MS sheet painted fire red out side and brilliant white inside yard complete all as specified and directed by the Engineer-in -Charge |
| 18 | M&L for Construct, fabricate complete Fire point made of PCC foundation, 40 mm thick 1:2:4 type Bo floring over 75 mm thick PCC 1:5:10 type E2 over rammed earth dwarf wall (Brick / PCC), including MS tubes, MS plate for hanging Fire buckets all as specified in TD drg No - AFB/TD/356/12 Sheet No 1/1 complete all as directed by the Engineer-in -Charge |
| 19 | S&R Fireman AXE ISI certified complete all as directed by the Engineer-in -Charge |
| 20 | S&F Fire hook/ ceiling hook ISI certified complete all as directed by the Engineer-in-Charge |
| 21 | S&F Fire buckets 9 litre (water/sand) as per IS 2546 complete all as directed by the Engineer-in -Charge |
| 22 | S&F Fire beater as per IS 8096 complete all as directed by the Engineer-in -Charge |
| 23 | S&F Shovel (GS) complete all as directed by the Engineer-in -Charge |
| 24 | M&L for Branch pipe gun metal 63mm instantaneous inlet, made threaded outlet, 15mm bore nozzle short complete all as specified and directed by the Engineer-in -Charge |
| 25 | Over hauling/maint/repairs to flame proof EOT crane 2.0 Ton/3.0 Ton capacity on gantry SWL, floor/ cabin operated of Make :Ambika Cranes are as under:- (a) Dismantling and taking down all major assy of crane such as longitudinal travel system assy, cross system travel assy, Hoisting system assy, except track if required from gantry for repair/replacement unserviceable spares. The repaires compromising the following shall be carried at :-(i) Cleaning, checking, repairing/servicing and setting of electromagnetic breaking system. (ii) De-rusting, cleaning, drying of all travel tracks incl removing splashed oil, birds waste, cheking and setting right allingement including tightning of all foundation bolts and providing one extra lock nuts to each bolts all as specified and directed by engineer-in-charge. (iii) Inspection, check and setting rights, cross travel trolly, cross travel motor, long travel motor, hoisting motors, gear box systems, including providing grease of proper grade/viscocity including worn out spares as required. (iv) Checking/greasing setting right bearing, bushes, hoisting pully steel rope drum, rope guide etc including replacement of worn out spares.(v) Inspection check and setting right of electric control system including wiring of panel/pandent control board including redressing the wires/cables. (vi) Repair/replacement of all other misc items necessary for safe and satisfactory function of crans incl replacement of worn out spares all as directed and required at site. (vii) Reassembling all part of cranes and remounting on gantry/track as originaly fitted including replacement of worn out nuts, bolts washers split pins,keys,thimble,gasket, pinion, etc complete with lubricants of all moving parts with proper lubricants all as specified and directed by Engineer-in-charge.NOTE :- (I) Cost of new spares parts which ever required to be measured and paid separately under \\"supply only\\" except nuts, bolts, washers, screws, split pins, rebates, keays, thimbles, gaskets, pinion, all kinds of lubricants (except gear oil), copper wire etc. Cost of which are deemed to included in rate quoted. |
| 26 | Limit switch |
| 27 | Cable trolly |
| 28 | Cable trolly bearing |
| 29 | Long travel contactor |
| 30 | Wire rope for hook (one standard length) |
| 31 | Gear pair set for hoisting travel, Cross travel, long travel (set of Six gears) |
| 32 | Oil seal set |
| 33 | Rope guide |
| 34 | Push button station |
| 35 | Long travel wheel bearing |
| 36 | Cross travel wheel bearing |
| 37 | Gear Oil |
| 38 | Hoisting contractor |
| 39 | Cross travel contractor |
| 40 | Bearing for main driving soft of LT |
| 41 | E/M Break |
| 42 | Over load relay |
| 43 | Single phase preventer |
| 44 | Welding to long travel track joints gaps incl providing and fixing 60cm long 10mm thick MS flat two Nos for supporting the track for proper allingement all as directed. |
| 45 | Taking down old unsv armoured Copper Control Cable 30 Core 2.5 sqmm for repeater Panel 12 Zone all as specified and directed by Engr-in-Charge. |
| 46 | M/L for Armoured Copper Control Cable 30 Core 2.5 sqmm for repeater Panel 12 Zone all as specified and directed by Engr-in-Charge. Make:-Havells/Polycab/Gloster |
| 47 | Excavation in trenches not exceeding 1.5mtr wide and not exceeding 1.5 mtr in deep for laying of cable etc, and getting out in any type of soil including stone putty etc complete all as specified and as directed by Engineer-in-charge. |
| 48 | Supply & laying steel Tubing galvanized medium grade (ISI Marked) 80 mm bore with all fittings ISI marked laid in trenches all as specified and directed by Engineer-in-charge. |
| 49 | Cutting/ chassing or Boring as required in hard standing/PCC / Road exceeding 10 Cm girth for concealed to GI tubing and making good to disturbed surface with cement mortar 1:3 to match with existing surfaces including facing/finishing where as required or as directed by Engineer-in-charge |
| 50 | M&L for sand cushioning to cable with tibba sand and punning to provide required cover complete all as directed by Engineer-in-Charge.(Note :- For the purpose of payment only punned thickness will be measured). |
| 51 | Supply & laying 40 to 50mm thick roughly hammer dressed Jodhpur stone patti cable cover 25cm to 30cm wide and n. exc 60cm long each laid dry abutting with each other with maximum gap between adjacent slabs n.ex 10mm complete all as specified & directed by Engineer-in-charge. |
| 52 | Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick in any type of soil complete all as specified and as directed by Engineer-in-charge. |
| 53 | Removing excavated materials to a distance not exceeding 50m depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed by Engineer-in-charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 03, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 27, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysAug 29, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender