Drinking Water Supply and Sanitation Government Departments Closing in 7 days TDR #56808218

Tender For Construction Of Ohsr/Ugsr For Various Villages Under The 67- Village Surface Water Project, Block Sri Anandpur Sahib, District Rupnagar.

Issued by Government Departments · Rupnagar, Punjab
Tender Value
1.97 Crore
Estimated cost
Bid Submission
17 Aug 2026
7 days left
EMD
3.94 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Rupnagar → Punjab
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction Of Ohsr/Ugsr For Various Villages Under The 67- Village Surface Water Project, Block Sri Anandpur Sahib, District Rupnagar.

BOQ

Name of Work:- Construction of OHSR/UGSR for various villages under the 67- village Surface Water Project, Block Sri Anandpur Sahib, District Rupnagar.
Sl. No. Item Description
1FOR VILLAGE RAIPURConstruction of One No. RCC OHSR of 50000 ltr. Capacity with sill level not less than 17 mtr. and FSL not to be less than 20 mtr. from formation level. complete with external RCC stair case with landing slabs at each staging RCC roof, ventilator, single manhole cover, lightening conductor and aluminum ladder inside OHSR & M.S ladder outside tank complete as described. Providing and fixing DI K-9 D/F expansion joints, Bell mouth and D/F puddle collars as per DWSS design on basis of enclosed drawing. Duck foot bends, conforming to ISI-13382 and C.I./D.I, D/F sluice valve duly ISI marked (IS-14486-2000 or latest) one each with inlet, outlet and scour pipes & overflow. DI double flanged pressure pipe DI K-9 horizontally as per IS 8329-2000 & latest dully ISI Marked from bottom dome to duck foot band & further up to 2.75 mtr. as per detailed specification. TMT Steel G.I. railing in 2 rows in both sides of approved make & Painting of all external surfaces complete in all respect. (Note:- The Specification & Drawing are based on safe bearing capacity of soil not less than 8.75 ton per sqm. In case the safe bearing capacity of less than 8.75 ton per sqm than the contractor shall submit his own design for foundation portion based on actual safe bearing capacity as per DWSS Specifications. The difference in quantity from the standard drawing based on 8.75 ton per sqm safe bearing capacity will be paid as per CSR + Prevailing ceiling premium) including providing & fixing automatic electronic water level control device & construction of plinth protection around the OHSR with brick masonry toe wall 40mm thick CC 1:2:4 on top cover, 100mm thick CC 1:8:16 & inside earth filling including over flow scour houdi complete in all respect.
2FOR VILLAGE MANGLOORConstruction of One No. RCC OHSR of 15000 ltr. Capacity with sill level not less than 13 mtr. and FSL not to be less than 15 mtr. from formation level. complete with external RCC stair case with landing slabs at each staging RCC roof, ventilator, single manhole cover, lightening conductor and aluminum ladder inside OHSR & M.S ladder outside tank complete as described. Providing and fixing DI K-9 D/F expansion joints, Bell mouth and D/F puddle collars as per DWSS design on basis of enclosed drawing. Duck foot bends, conforming to ISI-13382 and C.I./D.I, D/F sluice valve duly ISI marked (IS-14846-2000 or latest) one each with inlet, outlet and scour pipes & overflow. DI double flanged pressure pipe DI K-9 horizontally as per IS 8329-2000 & latest dully ISI Marked from bottom dome to duck foot band & further up to 2.75 mtr. as per detailed specification. TMT Steel G.I. railing in 2 rows in both sides of approved make & Painting of all external surfaces and providing and applying integral crystallin slury of hydrophillic in nature for water profiing managment etc. for vertical and horizontal surfaces and swellable type water stop tape complete in all respect. (Note:- The Specification & Drawing are based on safe bearing capacity of soil not less than 8.75 ton per sqm. In case the safe bearing capacity of less than 8.75 ton per sqm than the contractor shall submit his own design for foundation portion based on actual safe bearing capacity as per DWSS Specifications. The difference in quantity from the standard drawing based on 8.75 ton per sqm safe bearing capacity will be paid as per CSR + Prevailing ceiling premium) including providing & fixing automatic electronic water level control device & construction of plinth protection around the OHSR with brick masonry toe wall 40mm thick CC 1:2:4 on top cover, 100mm thick CC 1:8:16 & inside earth filling including over flow scour houdi complete in all respect.
3FOR VILLAGE LOWER PATTIConstruction of One No. RCC OHSR of 25000 ltr. Capacity with sill level not less than 15.50 mtr. and FSL not to be less than 17.20 mtr. from formation level. complete with external RCC stair case with landing slabs at each staging RCC roof, ventilator, single manhole cover, lightening conductor and aluminum ladder inside OHSR & M.S ladder outside tank complete as described. Providing and fixing DI K-9 D/F expansion joints, Bell mouth and D/F puddle collars as per DWSS design on basis of enclosed drawing. Duck foot bends, conforming to ISI-13382 and C.I./D.I, D/F sluice valve duly ISI marked (IS-14486-2000 or latest) one each with inlet, outlet and scour pipes & overflow. DI double flanged pressure pipe DI K-9 horizontally as per IS 8329-2000 & latest dully ISI Marked from bottom dome to duck foot band & further up to 2.75 mtr. as per detailed specification. TMT Steel G.I. railing in 2 rows in both sides of approved make & Painting of all external surfaces complete in all respect. (Note:- The Specification & Drawing are based on safe bearing capacity of soil not less than 8.75 ton per sqm. In case the safe bearing capacity of less than 8.75 ton per sqm than the contractor shall submit his own design for foundation portion based on actual safe bearing capacity as per DWSS Specifications. The difference in quantity from the standard drawing based on 8.75 ton per sqm safe bearing capacity will be paid as per CSR + Prevailing ceiling premium) including providing & fixing automatic electronic water level control device & construction of plinth protection around the OHSR with brick masonry toe wall 40mm thick CC 1:2:4 on top cover, 100mm thick CC 1:8:16 & inside earth filling including over flow scour houdi complete in all respect.
4FOR VILLAGE BANDLEHRI Construction of One No. RCC OHSR of 150000 ltr. Capacity with sill level not less than 23.50 mtr. and FSL not to be less than 27.50 mtr. from formation level. complete with external RCC stair case with landing slabs at each staging RCC roof, ventilator, single manhole cover, lightening conductor and aluminum ladder inside OHSR & M.S ladder outside tank complete as described. Providing and fixing DI K-9 D/F expansion joints, Bell mouth and D/F puddle collars as per DWSS design on basis of enclosed drawing. Duck foot bends, conforming to ISI-13382 and C.I./D.I, D/F sluice valve duly ISI marked (IS-14486-2000 or latest) one each with inlet, outlet and scour pipes & overflow. DI double flanged pressure pipe DI K-9 horizontally as per IS 8329-2000 & latest dully ISI Marked from bottom dome to duck foot band & further up to 2.75 mtr. as per detailed specification. TMT Steel G.I. railing in 2 rows in both sides of approved make & Painting of all external surfaces complete in all respect. (Note:- The Specification & Drawing are based on safe bearing capacity of soil not less than 8.75 ton per sqm. In case the safe bearing capacity of less than 8.75 ton per sqm than the contractor shall submit his own design for foundation portion based on actual safe bearing capacity as per DWSS Specifications. The difference in quantity from the standard drawing based on 8.75 ton per sqm safe bearing capacity will be paid as per CSR + Prevailing ceiling premium) including providing & fixing automatic electronic water level control device & construction of plinth protection around the OHSR with brick masonry toe wall 40mm thick CC 1:2:4 on top cover, 100mm thick CC 1:8:16 & inside earth filling including over flow scour houdi complete in all respect.
5FOR VILLAGE AJOULIConstruction of One No. RCC OHSR of 150000 ltr. Capacity with sill level not less than 23.50 mtr. and FSL not to be less than 27.50 mtr. from formation level. complete with external RCC stair case with landing slabs at each staging RCC roof, ventilator, single manhole cover, lightening conductor and aluminum ladder inside OHSR & M.S ladder outside tank complete as described. Providing and fixing DI K-9 D/F expansion joints, Bell mouth and D/F puddle collars as per DWSS design on basis of enclosed drawing. Duck foot bends, conforming to ISI-13382 and C.I./D.I, D/F sluice valve duly ISI marked (IS-14486-2000 or latest) one each with inlet, outlet and scour pipes & overflow. DI double flanged pressure pipe DI K-9 horizontally as per IS 8329-2000 & latest dully ISI Marked from bottom dome to duck foot band & further up to 2.75 mtr. as per detailed specification. TMT Steel G.I. railing in 2 rows in both sides of approved make & Painting of all external surfaces complete in all respect. (Note:- The Specification & Drawing are based on safe bearing capacity of soil not less than 8.75 ton per sqm. In case the safe bearing capacity of less than 8.75 ton per sqm than the contractor shall submit his own design for foundation portion based on actual safe bearing capacity as per DWSS Specifications. The difference in quantity from the standard drawing based on 8.75 ton per sqm safe bearing capacity will be paid as per CSR + Prevailing ceiling premium) including providing & fixing automatic electronic water level control device & construction of plinth protection around the OHSR with brick masonry toe wall 40mm thick CC 1:2:4 on top cover, 100mm thick CC 1:8:16 & inside earth filling including over flow scour houdi complete in all respect.
6FOR VILLAGE THALUHConstruction of One No. RCC OHSR of 75000 ltr. Capacity with sill level not less than 17 mtr. and FSL not to be less than 19 mtr. from formation level. complete with external RCC stair case with landing slabs at each staging RCC roof, ventilator, single manhole cover, lightening conductor and aluminum ladder inside OHSR & M.S ladder outside tank complete as described. Providing and fixing DI K-9 D/F expansion joints, Bell mouth and D/F puddle collars as per DWSS design on basis of enclosed drawing. Duck foot bends, conforming to ISI-13382 and C.I./D.I, D/F sluice valve duly ISI marked (IS-14486-2000 or latest) one each with inlet, outlet and scour pipes & overflow. DI double flanged pressure pipe DI K-9 horizontally as per IS 8329-2000 & latest dully ISI Marked from bottom dome to duck foot band & further up to 2.75 mtr. as per detailed specification. TMT Steel G.I. railing in 2 rows in both sides of approved make & Painting of all external surfaces complete in all respect. (Note:- The Specification & Drawing are based on safe bearing capacity of soil not less than 8.75 ton per sqm. In case the safe bearing capacity of less than 8.75 ton per sqm than the contractor shall submit his own design for foundation portion based on actual safe bearing capacity as per DWSS Specifications. The difference in quantity from the standard drawing based on 8.75 ton per sqm safe bearing capacity will be paid as per CSR + Prevailing ceiling premium) including providing & fixing automatic electronic water level control device & construction of plinth protection around the OHSR with brick masonry toe wall 40mm thick CC 1:2:4 on top cover, 100mm thick CC 1:8:16 & inside earth filling including over flow scour houdi complete in all respect.
7FOR VILLAGE BIKAPUR UPPERConstruction of One No. RCC OHSR of 1,50,000 ltr. Capacity with sill level not less than 23.50 mtr. and FSL not to be less than 27.50 mtr. from formation level. complete with external RCC stair case with landing slabs at each staging RCC roof, ventilator, single manhole cover, lightening conductor and aluminum ladder inside OHSR & M.S ladder outside tank complete as described. Providing and fixing DI K-9 D/F expansion joints, Bell mouth and D/F puddle collars as per DWSS design on basis of enclosed drawing. Duck foot bends, conforming to ISI-13382 and C.I./D.I, D/F sluice valve duly ISI marked (IS-14846-2000 or latest) one each with inlet, outlet and scour pipes & overflow. DI double flanged pressure pipe DI K-9 horizontally as per IS 8329-2000 & latest dully ISI Marked from bottom dome to duck foot band & further up to 2.75 mtr. as per detailed specification. TMT Steel G.I. railing in 2 rows in both sides of approved make & Painting of all external surfaces Providing and applying integral crystalling slurry of hydrophillic in nature for water proofing management etc. for vertical and horizontal surfaces and swellable typ water stop tap. complete in all respect. Note:- The Specification & Drawing are based on safe bearing capacity of soil not less than 8.75 ton per sqm. In case the safe bearing capacity of less than 8.75 ton per sqm than the contractor shall submit his own design for foundation portion based on actual safe bearing capacity as per DWSS Specifications. The difference in quantity from the standard drawing based on 8.75 ton per sqm safe bearing capacity will be paid as per CSR + Prevailing ceiling premium) including providing & fixing automatic electronic water level control device & construction of plinth protection around the OHSR with brick masonry toe wall 40mm thick CC 1:2:4 on top cover, 100mm thick CC 1:8:16 & inside earth filling including over flow scour houdi complete in all respect. ( All including carraige)
81 NO. UGSR
9FOR VILLAGE JANDAL UPPER Designing and Construction of 1 No. RCC Ground Storage Reservoir for clear water storage of 0.50 Lac Ltr. capacity at Village Patti including C.I. D/F Pipes and specials for Inlet, Outlet, Overflow and Scouring and bye pass arrangements, Sluice Valves of Premium quality with haudies, Automatic Float Arragement at delivery end for flow control, finishing wall with exterior decorating cement based snowcem, water level indicators, ventilators, manhole covers and aluminium ladder and all other works contingent there to complete in all respects (5.00 mtr. dia and FSL 2.55 mtr.) as per detail attached. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56808218
AUTHORITY Government Departments
TENDER VALUE 1.97 Crore
LAST DATE 17-08-2026
Authority
Authority Name Water Supply And Sanitation Department
Work Description Tender for Construction Of Ohsr/Ugsr For Various Villages Under The 67- Village Surface Water Project, Block Sri Anandpur Sahib, District Rupnagar.
Basic Detail
Tender No OHSR OF 67 villagw/4711 dt.03.08.2026
Bidding Type Tender
Location
City Rupnagar
State Punjab
Key Dates
Publish Date 03 Aug 2026
Submission Date 17 Aug 2026
Open Date 17 Aug 2026
Finance
Tender Value 1.97 Crore
Tender Fee 1000
EMD 3.94 Lakhs
Exemption Available
Document List
BOQ_351950.xls
DNIT.pdf
f774f8a4-9c7a-4dfd-ab33-5e6d6c499577.html
TDNIT.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 17, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Aug 17, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_351950.xls

pdf

DNIT.pdf

html

f774f8a4-9c7a-4dfd-ab33-5e6d6c499577.html

pdf

TDNIT.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders