Tender For Construction Of Ohsr/Ugsr For Various Villages Under The 67- Village Surface Water Project, Block Sri Anandpur Sahib, District Rupnagar.
Tender Value
1.97 Crore
Estimated cost
Bid Submission
17 Aug 2026
7 days left
EMD
3.94 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Rupnagar → Punjab
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Ohsr/Ugsr For Various Villages Under The 67- Village Surface Water Project, Block Sri Anandpur Sahib, District Rupnagar.
BOQ
| Sl. No. | Item Description |
| 1 | FOR VILLAGE RAIPURConstruction of One No. RCC OHSR of 50000 ltr. Capacity with sill level not less than 17 mtr. and FSL not to be less than 20 mtr. from formation level. complete with external RCC stair case with landing slabs at each staging RCC roof, ventilator, single manhole cover, lightening conductor and aluminum ladder inside OHSR & M.S ladder outside tank complete as described. Providing and fixing DI K-9 D/F expansion joints, Bell mouth and D/F puddle collars as per DWSS design on basis of enclosed drawing. Duck foot bends, conforming to ISI-13382 and C.I./D.I, D/F sluice valve duly ISI marked (IS-14486-2000 or latest) one each with inlet, outlet and scour pipes & overflow. DI double flanged pressure pipe DI K-9 horizontally as per IS 8329-2000 & latest dully ISI Marked from bottom dome to duck foot band & further up to 2.75 mtr. as per detailed specification. TMT Steel G.I. railing in 2 rows in both sides of approved make & Painting of all external surfaces complete in all respect. (Note:- The Specification & Drawing are based on safe bearing capacity of soil not less than 8.75 ton per sqm. In case the safe bearing capacity of less than 8.75 ton per sqm than the contractor shall submit his own design for foundation portion based on actual safe bearing capacity as per DWSS Specifications. The difference in quantity from the standard drawing based on 8.75 ton per sqm safe bearing capacity will be paid as per CSR + Prevailing ceiling premium) including providing & fixing automatic electronic water level control device & construction of plinth protection around the OHSR with brick masonry toe wall 40mm thick CC 1:2:4 on top cover, 100mm thick CC 1:8:16 & inside earth filling including over flow scour houdi complete in all respect. |
| 2 | FOR VILLAGE MANGLOORConstruction of One No. RCC OHSR of 15000 ltr. Capacity with sill level not less than 13 mtr. and FSL not to be less than 15 mtr. from formation level. complete with external RCC stair case with landing slabs at each staging RCC roof, ventilator, single manhole cover, lightening conductor and aluminum ladder inside OHSR & M.S ladder outside tank complete as described. Providing and fixing DI K-9 D/F expansion joints, Bell mouth and D/F puddle collars as per DWSS design on basis of enclosed drawing. Duck foot bends, conforming to ISI-13382 and C.I./D.I, D/F sluice valve duly ISI marked (IS-14846-2000 or latest) one each with inlet, outlet and scour pipes & overflow. DI double flanged pressure pipe DI K-9 horizontally as per IS 8329-2000 & latest dully ISI Marked from bottom dome to duck foot band & further up to 2.75 mtr. as per detailed specification. TMT Steel G.I. railing in 2 rows in both sides of approved make & Painting of all external surfaces and providing and applying integral crystallin slury of hydrophillic in nature for water profiing managment etc. for vertical and horizontal surfaces and swellable type water stop tape complete in all respect. (Note:- The Specification & Drawing are based on safe bearing capacity of soil not less than 8.75 ton per sqm. In case the safe bearing capacity of less than 8.75 ton per sqm than the contractor shall submit his own design for foundation portion based on actual safe bearing capacity as per DWSS Specifications. The difference in quantity from the standard drawing based on 8.75 ton per sqm safe bearing capacity will be paid as per CSR + Prevailing ceiling premium) including providing & fixing automatic electronic water level control device & construction of plinth protection around the OHSR with brick masonry toe wall 40mm thick CC 1:2:4 on top cover, 100mm thick CC 1:8:16 & inside earth filling including over flow scour houdi complete in all respect. |
| 3 | FOR VILLAGE LOWER PATTIConstruction of One No. RCC OHSR of 25000 ltr. Capacity with sill level not less than 15.50 mtr. and FSL not to be less than 17.20 mtr. from formation level. complete with external RCC stair case with landing slabs at each staging RCC roof, ventilator, single manhole cover, lightening conductor and aluminum ladder inside OHSR & M.S ladder outside tank complete as described. Providing and fixing DI K-9 D/F expansion joints, Bell mouth and D/F puddle collars as per DWSS design on basis of enclosed drawing. Duck foot bends, conforming to ISI-13382 and C.I./D.I, D/F sluice valve duly ISI marked (IS-14486-2000 or latest) one each with inlet, outlet and scour pipes & overflow. DI double flanged pressure pipe DI K-9 horizontally as per IS 8329-2000 & latest dully ISI Marked from bottom dome to duck foot band & further up to 2.75 mtr. as per detailed specification. TMT Steel G.I. railing in 2 rows in both sides of approved make & Painting of all external surfaces complete in all respect. (Note:- The Specification & Drawing are based on safe bearing capacity of soil not less than 8.75 ton per sqm. In case the safe bearing capacity of less than 8.75 ton per sqm than the contractor shall submit his own design for foundation portion based on actual safe bearing capacity as per DWSS Specifications. The difference in quantity from the standard drawing based on 8.75 ton per sqm safe bearing capacity will be paid as per CSR + Prevailing ceiling premium) including providing & fixing automatic electronic water level control device & construction of plinth protection around the OHSR with brick masonry toe wall 40mm thick CC 1:2:4 on top cover, 100mm thick CC 1:8:16 & inside earth filling including over flow scour houdi complete in all respect. |
| 4 | FOR VILLAGE BANDLEHRI Construction of One No. RCC OHSR of 150000 ltr. Capacity with sill level not less than 23.50 mtr. and FSL not to be less than 27.50 mtr. from formation level. complete with external RCC stair case with landing slabs at each staging RCC roof, ventilator, single manhole cover, lightening conductor and aluminum ladder inside OHSR & M.S ladder outside tank complete as described. Providing and fixing DI K-9 D/F expansion joints, Bell mouth and D/F puddle collars as per DWSS design on basis of enclosed drawing. Duck foot bends, conforming to ISI-13382 and C.I./D.I, D/F sluice valve duly ISI marked (IS-14486-2000 or latest) one each with inlet, outlet and scour pipes & overflow. DI double flanged pressure pipe DI K-9 horizontally as per IS 8329-2000 & latest dully ISI Marked from bottom dome to duck foot band & further up to 2.75 mtr. as per detailed specification. TMT Steel G.I. railing in 2 rows in both sides of approved make & Painting of all external surfaces complete in all respect. (Note:- The Specification & Drawing are based on safe bearing capacity of soil not less than 8.75 ton per sqm. In case the safe bearing capacity of less than 8.75 ton per sqm than the contractor shall submit his own design for foundation portion based on actual safe bearing capacity as per DWSS Specifications. The difference in quantity from the standard drawing based on 8.75 ton per sqm safe bearing capacity will be paid as per CSR + Prevailing ceiling premium) including providing & fixing automatic electronic water level control device & construction of plinth protection around the OHSR with brick masonry toe wall 40mm thick CC 1:2:4 on top cover, 100mm thick CC 1:8:16 & inside earth filling including over flow scour houdi complete in all respect. |
| 5 | FOR VILLAGE AJOULIConstruction of One No. RCC OHSR of 150000 ltr. Capacity with sill level not less than 23.50 mtr. and FSL not to be less than 27.50 mtr. from formation level. complete with external RCC stair case with landing slabs at each staging RCC roof, ventilator, single manhole cover, lightening conductor and aluminum ladder inside OHSR & M.S ladder outside tank complete as described. Providing and fixing DI K-9 D/F expansion joints, Bell mouth and D/F puddle collars as per DWSS design on basis of enclosed drawing. Duck foot bends, conforming to ISI-13382 and C.I./D.I, D/F sluice valve duly ISI marked (IS-14486-2000 or latest) one each with inlet, outlet and scour pipes & overflow. DI double flanged pressure pipe DI K-9 horizontally as per IS 8329-2000 & latest dully ISI Marked from bottom dome to duck foot band & further up to 2.75 mtr. as per detailed specification. TMT Steel G.I. railing in 2 rows in both sides of approved make & Painting of all external surfaces complete in all respect. (Note:- The Specification & Drawing are based on safe bearing capacity of soil not less than 8.75 ton per sqm. In case the safe bearing capacity of less than 8.75 ton per sqm than the contractor shall submit his own design for foundation portion based on actual safe bearing capacity as per DWSS Specifications. The difference in quantity from the standard drawing based on 8.75 ton per sqm safe bearing capacity will be paid as per CSR + Prevailing ceiling premium) including providing & fixing automatic electronic water level control device & construction of plinth protection around the OHSR with brick masonry toe wall 40mm thick CC 1:2:4 on top cover, 100mm thick CC 1:8:16 & inside earth filling including over flow scour houdi complete in all respect. |
| 6 | FOR VILLAGE THALUHConstruction of One No. RCC OHSR of 75000 ltr. Capacity with sill level not less than 17 mtr. and FSL not to be less than 19 mtr. from formation level. complete with external RCC stair case with landing slabs at each staging RCC roof, ventilator, single manhole cover, lightening conductor and aluminum ladder inside OHSR & M.S ladder outside tank complete as described. Providing and fixing DI K-9 D/F expansion joints, Bell mouth and D/F puddle collars as per DWSS design on basis of enclosed drawing. Duck foot bends, conforming to ISI-13382 and C.I./D.I, D/F sluice valve duly ISI marked (IS-14486-2000 or latest) one each with inlet, outlet and scour pipes & overflow. DI double flanged pressure pipe DI K-9 horizontally as per IS 8329-2000 & latest dully ISI Marked from bottom dome to duck foot band & further up to 2.75 mtr. as per detailed specification. TMT Steel G.I. railing in 2 rows in both sides of approved make & Painting of all external surfaces complete in all respect. (Note:- The Specification & Drawing are based on safe bearing capacity of soil not less than 8.75 ton per sqm. In case the safe bearing capacity of less than 8.75 ton per sqm than the contractor shall submit his own design for foundation portion based on actual safe bearing capacity as per DWSS Specifications. The difference in quantity from the standard drawing based on 8.75 ton per sqm safe bearing capacity will be paid as per CSR + Prevailing ceiling premium) including providing & fixing automatic electronic water level control device & construction of plinth protection around the OHSR with brick masonry toe wall 40mm thick CC 1:2:4 on top cover, 100mm thick CC 1:8:16 & inside earth filling including over flow scour houdi complete in all respect. |
| 7 | FOR VILLAGE BIKAPUR UPPERConstruction of One No. RCC OHSR of 1,50,000 ltr. Capacity with sill level not less than 23.50 mtr. and FSL not to be less than 27.50 mtr. from formation level. complete with external RCC stair case with landing slabs at each staging RCC roof, ventilator, single manhole cover, lightening conductor and aluminum ladder inside OHSR & M.S ladder outside tank complete as described. Providing and fixing DI K-9 D/F expansion joints, Bell mouth and D/F puddle collars as per DWSS design on basis of enclosed drawing. Duck foot bends, conforming to ISI-13382 and C.I./D.I, D/F sluice valve duly ISI marked (IS-14846-2000 or latest) one each with inlet, outlet and scour pipes & overflow. DI double flanged pressure pipe DI K-9 horizontally as per IS 8329-2000 & latest dully ISI Marked from bottom dome to duck foot band & further up to 2.75 mtr. as per detailed specification. TMT Steel G.I. railing in 2 rows in both sides of approved make & Painting of all external surfaces Providing and applying integral crystalling slurry of hydrophillic in nature for water proofing management etc. for vertical and horizontal surfaces and swellable typ water stop tap. complete in all respect. Note:- The Specification & Drawing are based on safe bearing capacity of soil not less than 8.75 ton per sqm. In case the safe bearing capacity of less than 8.75 ton per sqm than the contractor shall submit his own design for foundation portion based on actual safe bearing capacity as per DWSS Specifications. The difference in quantity from the standard drawing based on 8.75 ton per sqm safe bearing capacity will be paid as per CSR + Prevailing ceiling premium) including providing & fixing automatic electronic water level control device & construction of plinth protection around the OHSR with brick masonry toe wall 40mm thick CC 1:2:4 on top cover, 100mm thick CC 1:8:16 & inside earth filling including over flow scour houdi complete in all respect. ( All including carraige) |
| 8 | 1 NO. UGSR |
| 9 | FOR VILLAGE JANDAL UPPER Designing and Construction of 1 No. RCC Ground Storage Reservoir for clear water storage of 0.50 Lac Ltr. capacity at Village Patti including C.I. D/F Pipes and specials for Inlet, Outlet, Overflow and Scouring and bye pass arrangements, Sluice Valves of Premium quality with haudies, Automatic Float Arragement at delivery end for flow control, finishing wall with exterior decorating cement based snowcem, water level indicators, ventilators, manhole covers and aluminium ladder and all other works contingent there to complete in all respects (5.00 mtr. dia and FSL 2.55 mtr.) as per detail attached. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 03, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 17, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysAug 17, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender