Housing Urban and Rular Development Local Bodies Closing in 18 days TDR #56807919

Tender For Construction And Maintenance Of A Swimming Pool At The Sports Stadium Located In The Karwi Urban Area Of ​​Chitrakoot District

Issued by Local Bodies · Chitrakoot, Uttar Pradesh
Tender Value
4.10 Crore
Estimated cost
Bid Submission
21 Aug 2026
18 days left
EMD
8.20 Lakhs
Bank guarantee accepted
Document Fee
5900
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chitrakoot → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction And Maintenance Of A Swimming Pool At The Sports Stadium Located In The Karwi Urban Area Of ​​Chitrakoot District

BOQ

Name of Work:- Construction and maintenance of a swimming pool at the sports stadium located in the Karwi urban area of ​​Chitrakoot district
Sl. No. Item Description
1Building and Shed Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.(D.S.R.2023/2.31)
2Felling trees of the girth (measured at a height of 1 m above ground level), including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material. Beyond 30 cm girth upto and including 60 cm girth. (D.S.R.2023/2.33.1)
3Layout of building and making reference pillars etc. complete with all respect as per instruction of engineer-in-charge. (CMR)
4Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.All kinds of soil (D.S.R.2023/2.6.1)
5Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. (D.S.R.2023/2.27)
6Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (D.S.R.2023/2.25)
7Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) (D.S.R.2023/4.1.8)
8Providing and laying in position specified grade of Column, Footing, Plinth reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). (D.S.R.2023/5.1.2)
9Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). (D.S.R.2023/5.2.2)
10Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo Mechanically Treated bars. (D.S.R.2023/5.22.6)
11Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete. (D.S.R.2023/5.9.1) For Column Footing
12Columns, Pillars, Piers, Abutments, Posts and Struts. (D.S.R.2023/5.9.6) For Column Ht. up to plinth Lvl.
13Lintels, beams, plinth beams, girders, bressumers and cantilevers. with water proof ply 12 mm thick. (D.S.R.2023 / 5.9.21) For Plinth Beam ( BOTH SIDE ONLY ) thick. (D.S.R.2023/5.9.21) For Plinth Beam ( BOTH SIDE ONLY )
14Suspended floors, roofs, landings, balconies and access platform. with water proof ply 12 mm thick.(D.S.R.2023/5.9.20)
15Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.(D.S.R.2023/5.9.2) BALANCING TANK WALL
16Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete :(D.S.R.2023/19.21.1) For pipes 100 to 250 mm diameter for balancing tank connection
17Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) (D.S.R.2023/6.1.2) Plinth Fill below outer plinth beams
18Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand). (D.S.R.2023/6.4.1)
1915 mm cement plaster on rough side of single or half brick wall of mix: :1:4 (1 cement: 4 coarse sand). (D.S.R.2023/13.5.1)
20Extra for providing and mixing water proofing material in cement plasterwork in proportion recommended by the manufacturers. (D.S.R.2023/13.21) per bag of 50kg cement used in the mix Cement Coefficient - 654Kg/100 SQM
21Providing precast cement concrete Jali 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 6 mm nominal size ), reinforced with 1.6 mm dia mild steel wire, including centering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3 (1 cement: 3 fine sand) etc. complete, excluding plastering of the jambs, sills and soffits. 50 MM thick (D.S.R.2023/5.18.1 ) Above Brick wall upto metal roofing
22Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (D.S.R.2023/13.80) Plaster area & Concrete Jali
23Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm (D.S.R.2023/13.48.1)
24Providing and fixing thermal insulation with Resin Bonded Fibre glass wool conforming to IS: 8183. Density 16 kg/m³, 50 mm thick, wrapped in 200G Virgin Polythene bags placed over existing false ceiling and held in position by criss crossing GI wire.(D.S.R.2023/12.57)
25Providing and fixing false ceiling at all heights including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer’s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum moisture resistant board. (D.S.R.2023/11.45.3)
26Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of size.Size of Tile 800 x 800mm (D.S.R.2023/11.41A.3.3 )
27Deduct for not grouting the joints with white cement and matching pigment in the items of fixing of vitrified tiles. (D.S.R.2023/11.50)
28Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 800x800 mm. (D.S.R.2023/11.48.3)
29Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.Granite stone slab of colour black, Cherry/Ruby red Area of slab over 0.50 sqm (D.S.R.2023/8.2.2)
30Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 800x800 mm (D.S.R.2023/11.47.3)
31Providing & fixing at all heights, levels and locations colour finish Aluminium alloy roofing sheets of alloy IS designation 31500, temper Hx8 conforming to IS 737 and dimensions as per IS code 2676 with characteristics of good formability and corrosion resistance. The profile sheets shall be fixed to truss members in slope or required pitch or curvature with Hex cap headed self drilling/tapping Stainless steel screws M6, 50 mm long with 3 mm EPDM seal washer etc. all inclusive of labour, scaffolding, T&P and sundries etc. complete as per directions of the Engineer-In-Charge. (Cost of truss/frame work shall be paid separately). 0.56 mm, Aluminium Colour coated troughed profile with center to center pitch of 200 mm, depth of 32 mm, overall profile width 1092 mm, cover width 1000 mm. (D.S.R.2023/12.65.1)
32Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (D.S.R.2023/10.1)
33Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (D.S.R.2023/10.2)
34Providing & fixing at all heights, levels and locations Opal finish Solid Polycaronate roofing sheets. The profile sheets shall be fixed to truss members in slope or required pitch or curvature with Hex cap headed self drilling/tapping Stainless steel screws M6, 50 mm long with 3 mm EPDM seal washer etc. all inclusive of labour, scaffolding, T&P and sundries etc. complete as per directions of the Engineer-In-Charge. (Cost of truss/frame work shall be paid separately). 2.0 mm, Solid Polycarbonate Opal Finish troughed profile with center to center pitch of 200 mm, depth of 32 mm, overall profile width1092 mm, cover width 1000mm.Analysis Attached
35Providing and fixing hard drawn steel wire fabric of size 75 x25 mm mesh or other suitable size wire mesh to be fixed & firmly anchored to the concrete surface by means of “L” shaped mild steel shear key welded with existing reinforcement including the cost of materials, labour, tool & plants as approved by Engineer-in-charge. (D.S.R.2023/26.40) On both sides of Roof Monitor
36Providing and fixing of Pre-coated colour or mill finish Aluminium Roofing Accessories in 0.71 mm thickness ,Alloy 31500 (IS designation) [Aluminium Alloy (AA) 3004 (ISO designation)]. For colour, coating shall be 5-7 microns epoxy primer on both sides of the sheet and polyester top coat 15-18 microns, using self drilling/tapping SS screws of size 6 x 50 mm with 3 mm thick EPDM seal and SS plain washer complete :Precoated/mill finish aluminium Flashings/ Aprons (Upto 600 mm) (D.S.R.2023/12.66.2)
37Providing and fixing of Pre-coated colour or mill finish Aluminium Roofing Accessories in 0.71 mm thickness ,Alloy 31500 (IS designation) [Aluminium Alloy (AA) 3004 (ISO designation)]. For colour, coating shall be 5-7 microns epoxy primer on both sides of the sheet and polyester top coat 15-18 microns, using self drilling/tapping SS screws of size 6 x 50 mm with 3 mm thick EPDM seal and SS plain washer complete :Precoated/mill finish aluminium Gutter (600 mm over all girth) (D.S.R.2023/12.66.6)
38Providing and fixing of Pre-coated colour or mill finish Aluminium Roofing Accessories in 0.71 mm thickness ,Alloy 31500 (IS designation) [Aluminium Alloy (AA) 3004 (ISO designation)]. For colour, coating shall be 5-7 microns epoxy primer on both sides of the sheet and polyester top coat 15-18 microns, using self drilling/tapping SS screws of size 6 x 50 mm with 3 mm thick EPDM seal and SS plain washer complete : Precoated/mill finish aluminium North light curves (D.S.R.2023/12.66.3)
39Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter(D.S.R.2023/12.41.2)
40Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Shoe (Plain) (D.S.R.2023/12.42.6)
41Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.(D.S.R.2023/12.44)
42Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110mm (D.S.R.2023/12.43.2)
43Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work (D.S.R.2023/ 13.52.1 )
44Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap betweenframe and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately. Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for : (i) Sites with basic wind speed > 45 m/sec as per IS 875 – Part 3. (ii) Sites with structure height more than 20m for all wind speeds Casement door double panel with French (False) Mullion with zinc alloy (zamak) 3D hinges, multi-point locking system with cylinder, zinc alloy (zamak) powder coatedhandles on both sides. Using R3 series with frame (55 mm & above) x (50 mm & above) & sash (55 mm & above) x (85 mm & above) & French (False) mullion (55 mm & above) x (60 mm & above). (Height upto 2.5 metre). (D.S.R.2023/9.147.F2.1)
45Casement door single panel with zinc alloy (zamak) 3D hinges, multi-point locking system with cylinder, zinc alloy (zamak) powder coated handles on both sides.Using R3 series with frame (55 mm & above) x (50 mm & above) & sash (55 mm & above) x (85 mm & above) (Height upto 2.5 metre). (D.S.R.2023/9.147.F1.1)
46Ventilator Casement window single panel with or without fixed panel with S.S. 304 friction hinges as per size and weight of sash, single point locking zinc alloy (zamak)powder coated handles.Using R1 series with frame (33 mm & above ) x (35 mm & above) & sash /mullion (33 mm & above) x (50 mm & above). (Height upto 0.90 metre). (D.S.R.2023/9.147.D1.1)
47Fixed window / ventilator with mullion / transom. Using R4 series with frame (64 mm & above ) x (50 mm & above) & mullion (64 mm & above) x (70 mm & above). (Height above 2.5 metre). (D.S.R.2023/9.147.C2.4) Glass pane
48Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontal side & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet (Zinc coating not less than 120 gm/sqm) suitable for mounting 120 minutes Fire Rated Glazed Door Shutters. The frame shall be filled with mineral wool Insulation having density minimum 96Kg/sqm. The frame will have a provision of G.I. anchor fastners 14 nos (5 each on vertical style & 4 on horizontal style of size M10 x 80) suitable for fixing in the opening along with factory made template for SS ball bearing hinges of size 100x89x3 mm for fixing of fire rated glazed shutter. The frame shall be finished with an approved fire resistant primer or powder coating of not less than 30 micron in desired shade as per the directions of Engineer - in- Charge. (Cost of SS ball bearing hinges is excluded). (D.S.R.2023/9.161)D4
49Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 minutes Fire rating conforming to IS:3614 (Part II) or EN1634-1:1999, tested and certified as per laboratory approved by Engineer-in-Charge, with suitable mounting on door frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60 mm made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/ sqm) duly filled mineral wool insulation having density minimum 96 kg/ cum and fixing with necessary stainless steel ball bearing hinges of size 100x89x3 mm of approved make, including applying a coat of approved fire resistant primer or powder coating not less than 30 micron etc all complete as per direction of Engineer-in-Charge (panelling to be paid for seperately). (D.S.R.2023/9.162)
50Toughened glass 12 mm thickness. (D.S.R.2023/8778 )
51(a) Supplying, installation, testing and commissioning of electric driven terrace pump conforming to IS 12469: 2019 suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) (b) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal as required. (c) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class- 'F' insulation, conforming to IS-12615: 2018. (d) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. (e) Suitable cement concrete foundation duly plastered and with anti vibration pads. 450 lpm at 35 m Head(D.S.R.2023/27.4.2)
52Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.(D.S.R.2023/27.22)
53Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required.100mm dia (D.S.R.2023/27.23.1)
54Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.(D.S.R.2023/27.13)
55Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank gunmetal/ Stainless Steel cap and chain as required Single headed Stainless steel(D.S.R.2023/27.9.2)
56Supplying, fixing, testing and commissioning of butterfly valve of PN 16 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 100 mm dia (D.S.R.2023/27.11.5)
57Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 100 mm dia (D.S.R.2023/27.14.5)
58Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required : 100 mm dia (D.S.R.2023/27.12.5)
59Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. 100 mm dia (D.S.R.2023/27.15.2)
60Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. (a) 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 (b) 20 mm nominal internal dia gun metal globe valve & nozzle. (c) Drum and brackets for fixing the equipmets on wall. (d) Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 30 M (D.S.R.2023/27.17.1)
61Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required: 2 way-100 mm dia M.S. Pipe(D.S.R.2023/27.19.1)
62Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required. 4 Zone (D.S.R.2023/28.1.9.1 )
63Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.(D.S.R.2023/28.1.3 )
64Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 100 mm dia (D.S.R.2023/27.7.7)
65Supply & Installation of Aluminum Parametric Structure ART Sculpture DEPTH 300mm ,Bent 25mm, GAP 75mm, (3MM THICKNESS ALUMINUM WITH POLYESTER POWDER COATING East facade only ( AS QUOTATION )
66Clay Brick Tile Cladding Suuply only Model - CBED 01 Country Blend Drag Faced Size - 230 x 70 x 20mm , Make - Prayag Clay Products , East and Entrance walls
67Installation of Clay Brick Tile over Already Plastered wall , using approved adhesive, grove finished with pigmented cement . Finished with Clear Water proof Coating by spray method .
68Providing & Installing Signages - SS 304 plates of thickness 1mm , Matt finished, Engraved & filled with Black color to finish the design as per Engineer in charge , installed with SS screws on walls (CMR )
69Horticulture operations including 300mm earth filling , grassing , tree plantations, shrubs and potted plants etc. (CPWD PAR 2025/6.9.1)
70Supplying, Installation,testing and comissioning of grid interactive roof top solar photo voltaic power generation system including space frame.(CPWD PAR 2025/7.8.1)
71Swimming Pool Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas(exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.All kinds of soil (D.S.R.2023/2.6.1)
72Supplying and filling in plinth with sand under floors, including watering,ramming, consolidating and dressing complete. (D.S.R.2023/2.27)
73Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50m and lift upto 1.5m. (D.S.R.2023/2.25)
74Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) (D.S.R.2023/4.1.8)
75Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.:). All works upto plinth level (D.S.R.2023/5.33.1) Concrete of M30 grade with minimum cement content of 350 kg /cum (D.S.R.2023/5.33.1.2)
76Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo Mechanically Treated bars. (D.S.R.2023/5.22.6)
77Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete. (D.S.R.2023/5.9.1)
78Centering and shuttering including strutting, propping etc. and removal of form for :Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.(D.S.R.2023/5.9.2)
79Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand). (D.S.R.2023/6.1.1)
8020 mm cement plaster of mix : :1:4 (1 cement: 4 coarse sand). (D.S.R.2023/13.6.1)
81Extra for providing and mixing water proofing material in cement plasterwork in proportion recommended by the manufacturers. (D.S.R.2023/13.21) per bag of 50kg cement used in the mix Cement Coefficient - 654Kg/100 SQM
82Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by theEngineer-in-Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. (D.S.R.2023/11.55.1)
83Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work (D.S.R.2023/8.3.2)
84Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 800x800 mm (D.S.R.2023/11.47.3)
85Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 800x800 mm. (D.S.R.2023/11.48.3)
86Providing and fixing Glass mossaic tiles on finished plain wall surface of size 20 mm x 20 mm x 4 mm in all colour, design , fixing in customizedesign as per direction of Engineer-in- Charge. The glass mosaic tiles to be fixed on the wall surface with the help of approved adhesive applied at the rate of 2.5 kg per sqm and grouting of the same. The rate is inclusive of all operation, material and required pattern approved by Engineer-in-Charge: (D.S.R.2023/11.53) Make - Tile - Italia , Adhesive/Grout - MYK laticrete
87Providing and mixing integral crystalline admixture for water proofing treatment to RCC structures like basement raft, retaining walls, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc. at the time of transporting of concrete into the drum of the ready-mix truck , using integral crystalline admixture @0.80% (minimum) to the weight of cement content per cubic meter of concrete) or higher as recommended by the manufacturer’s specification in reinforced cement concrete at site of work. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e. by reducing permeability of concrete by more than 90%, compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure. The crystalline admixture shall be capable of selfhealing of cracks up to a width of 0.50 mm. The work shall be carried out all complete as per specification and the direction of the Engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.(D.S.R.2023/22.22) 1% by weight of cement @ 3.5Kg /CUM
88Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50 mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. (D.S.R.2023/22.23) For vertical surface two coats @ 0.70 kg per sqm per coat. (D.S.R.2023/22.23.1)
89For horizontal surface one coat @1.10 kg per sqm. (D.S.R.2023/22.23.2)
90Providing and applying of swellable type water stop tape, 19 mm x 25 mm thick in linear metre (expansive nature) for construction joints treatment of RCC structure such as raft slab, retaining walls, water storage tank and at the junctions of raft slab with the retaining walls etc.. After cleaning the surface, one coat of required primer for swellable water stop tape shall be applied throughout the length of the joint @3.78 litre per 240 running metre. Over the primed surface swellable type water stop tape shall be placed. The work shall be carried out all complete as per specification and the direction of the Engineer-In-Charge. The product performance shall carry guarantee for 10 years against any leakage. (D.S.R.2023/22.26)
91Plumbing & Mechanical Nilkamal 100 L Roto Molded Chemical Storage Drum/ Dosing Tank LLDPE(CMR )
92Plumbing Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil (D.S.R.2023/2.8.1)
93Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) (D.S.R.2023/4.1.8)
94Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand). (D.S.R.2023/6.4.1)
9515 mm cement plaster on rough side of single or half brick wall of mix: :1:6 (1 cement: 6 coarse sand). (D.S.R.2023/13.5.2)
96Weather Silicon sealant (D.S.R.2023/8646)
97Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 1500x450 mm (D.S.R.2023/17.32.4)
98Providing and fixing uplasticised PVC connection pipe with brass unions : 30 cm length 15 mm nominal bore (D.S.R.2023/18.21.1.1)
99Providing and fixing C.P. Brass 15 mm Urinal spreader size 95x69x100 mm with 1/2” BSP thread and shapes, weighing not less than 150 gms.(CMR)
100Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 40 mm nominal bore (D.S.R.2023/18.17.3)
101Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.(D.S.R.2023/18.48)
102Providing and fixing C.P. Brass extension nipple (size 15 mm x 50 mm) of approved make and quality as per direction of Engineer-in-charge..(D.S.R.2023/18.53A)
103Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore.(D.S.R.2023/18.18.3)
104Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes (D.S.R.2023/18.8.2)
105Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal dia Pipes (D.S.R.2023/18.8.4)
106Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 40 mm nominal dia Pipes (D.S.R.2023/18.9.5)
107Providing and fixing PVC pipes (working pressure 4 kg / cm²) Single socketed pipe 110 mm dia This includes jointing of pipes & fittings with solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. P.C.C. paid for saperately ( Analysis )
108Cutting holes up to 30x30 cm in walls including making good the same: With common burnt clay F.P.S. (non modular) bricks (D.S.R.2023/18.76.1)
109Installation of Concealed Fittings including cutting brick work and fixing in cement mortar 1:3 (1 cement : 3 fine sand) and making good the walls etc.
110Installation of Complete Fittings including After fixing fixtures the gap between fixture and adjacent finished wall shall be filled with weather proof silicon sealant all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge.
111URINAL MODESTY SS
112COMMERCIAL VANITY WALL MOUNTED
113MERINO LOCKER TYPE-A2
114BESCO CUBICLE PARTITION WT SS ROUND TOP RAIL
115BESCO TITAN 12 BOXUP WH ROUND TOP RAIL 2100MM
116Emaux imported sand filter with PVC Laterals and 75mm dia 6 way multi port control valve with unions and pressure guage complete :-Maximum working pressure : 2.5kg/cm2 Testing pressure:4kg/cm2 Flow Rate - 56.5 cubic meter per hour per Filter Material Of Construction- Bobbin Wound Reinforced Fiberglass Size - 1200 mm dia x 1634 mm High
117NATURAL SAND Filter Media for above Filters ( 875 KG PER FILTER )
118FILTRATION CUM CIRCULATING PUMPS (EPH 300) - Built in thermal protection & Overload Protection Capacity-29 cubic mete per hour per pump Discharge head-12mtr Connection Size -75mmx75mm Basket Volume - 5 Litres ENTRIFUGAL TYPE HP - 3.0 HP, Single / Three phase 3 working and 1 stand by
119Mild steel base frame for FILTRATION CUM CIRCULATING PUMP (EPH 300)
12075 mm dia Double union ball valve for suction, delivery UPVCU-PN10
12190 mm dia Flange Mount Wafer Check Valve UPVCU-PN10
12263 mm dia Double union Ball valve for other equipments UPVCU-PN10
123100 mm dia Butterfly valve for isolation UPVCU-PN10
124100mm Ball Foot valve UPVCU-PN10
125100 mm dia C.I. Sluice Valve PN16 with extension rod and handle upto surface for pool drain lines( Kirloskar ) UPVCU-PN10
126CHEMICAL DOSING & SANITATION EQUIPMENT NanoTech UV-C with timer and AMALGAM LAMPS for water disinfection . S.S. UV system 110-240V, Flow rate : 30 m3/h Lamp Life : 12000 Hrs Connection Size : 63mm Model - NT UV 130 TF Power - 130 Watt with Timer
127Automatic Online feeder pump for injecting Chemicals The Emaux CyberSync dosing pump Model : DP300-ORP/PH(HIGH & LOW) MOC : LED Display Input Power : 20 W Operating Voltage : 110-240 Flow Rate - 3 LPH at 22 Psi Measurable Range - Ph4-Ph10 / ORP 300 - 900mV
128PVC Filtered Water Inlet Nozzles - 2\\" dia Nozzle Model : EM 2861( Solvent Fit ) Flow rate : 200 LPM MOC : ABS Connection Size : 63mm
129531 x 531 mm ABS Drain plate for pool sump with AISI 316 Stainless Steel Frame Type : Drain Cover Model : EM2816 Size : 531 x 531mm Flow rate : 3600 L/min
130PVC Vacuum Point Nozzles Model : EM 2822 ( solvent fit ) Flow rate : 150 LPM MOC : ABS Connection Size : 63mm
131POOL CLEANING EQUIPMENT Stainless steel 316 fabricated trolley for pump
132EMUAX make 2 HP pump for suction sweeper - Sb20
1332 HP single phase DOL starter ( L&T / BCH )
1343 core 2.5 sq mm cable ( PolyCab/Havells )
135450 mm wide aluminium suction sweeping head EMAUX
13640 mm dia Vacuum hose pipe 15 mtr long - EMAUX
137PVC pipe connections
1382 x 4 mtr Long aluminium handle EMAUX
139Hand Skimmer & Leaf Rake - CE 101 EMAUX
140P.P. Cleaning Brush 18 inches - CE 201 EMAUX
141S.S. Algea Brush 18 inches - CE 206 EMAUX
142ELECTRICAL WORKS Component Make : Schneider / Siemens/L&TElectrical panel suitable for the circulating pumps, chemcial dosers and suction sweeper equipment complete with starters, relays, contactors, push buttons, indicating lamps complete with wiring work between pump and panel only Cost includes : Heavy 2mm CRCA steel sheeting, precision industrial powder coating, internal mounting chassis, and premium neoprene weather sealing .63A 4-Pole MCCB and 63A 4-Pole 30mA life-safety RCCB.MPCBs,power contactors, and dedicated branch safety RCBOs. Digital cyclic automation( programmed for distributed usage)
1432 x 2.5 Sq. mm PVC insulated copper cable for inter junction box connection upto Control Panel within 25mm Medium class PVC conduit pipe recessed under deck floor
144PIPING INSIDE FILTER ROOM Necessary PVC piping complete with fittings etc within the filter room related to all pool equipments 63/75/90mm PVC Solvent Fit Pipes & Fittings 10 KGf/cm2 Pressure Rated - Make SUPREME
145OUTSIDE PLANT ROOM PIPING WORK 110 mm ( 4\\") dia uPVC filter water piping work with necessary fittings from balancing tank to filter room and from plant room to swimming pool inlet ( 10 kgf/cm2 )
14675 mm ( 2.5 \\") uPVC filtered water piping work with necessary fittings for fixing inlet nozzles inside the swimming pool floor only (10 kgf/cm2 )
147110 mm (4\\") uPVC piping from swimming pool drain sump to balancing tank ( 10 kgf/cm2 )
148200 mm (8\\") dia uPVC piping from swimming pool overflow drain channel to balancing tank ( 4 kgf/cm2 )
149Erection charges for the filtration equipments
150SWIMMING POOL ACCESSORIES POOL Ladder 4 steps on both ends - Adult Pool Model : NSF415-SR Size : 4 Step MOC : 42mm Stainless Steel 304 with anti slip pad
151POOL Ladder 2 steps on both ends - kids Pool Model : NSF215-SR Size : 2 Step MOC : 42mm Stainless Steel 304 with anti slip pad
152Exit Handrail Model : ARN415 MOC : φ42mm tubes in polished stainless steel 304 Size : 4 Step
153Pool Light 35 Watt - Adult Pool Model : E-Lumen-441(262mm DIA ) Power : 35 Watt - 12V AC MOC : ABS + UV Stabilizer IP Rating : IP68
154Pool Light 20 Watt - Adult Pool Model : E-Lumen-252(262 mm DIA ) Power : 20 Watt - 12V AC MOC : ABS + UV Stabilizer IP Rating : IP68
15512V Step down transformer for Lights Model : TRA 300 VA Size : 300 VA MOC : PVC
156Electrical Junction Box(Flush Deck Installation for each light) Model : EM2823C Type : 1 Mtr Hose with connectors MOC : PVC with Seal Cap
157Zigzag type ABS grating for Overflow drains ( 10\\" ) 250 mm wide x 30 mm high ABS grade overflow channel grating for pool Model - DE 2625 EMAUX make
158Starting Platform Model : STP30R - 500 x 500 mm MOC : Stainless Steel AISI-316 pedestal and backstroke handle Fiber glass Platform & Anti Slip Tread Step
159Racing Lane Model : EOP001 MOC : Stainless Steel rod with brass ferrule and glass filled polycarbonate body construction.Size : 110mm diameter -25Mtr Length Cable is SS316 with diameter of 3.1mm and max force of 5KN.
160Overflow Lane anchor & Hook Model - EOP 121 & 122 MOC : Stainless Steel AISI-316
161Lane Roller holds up to 6 x 25m Small 110mm lanes Strong SS316 Castor Wheels with brake.Powder Coated Aluminum construction.
162Manual Water Test Kit Specification : Chlorine & PH test kit Model : CE 031
163CONNECTION & COMMISSIONING CHARGES
164GRAB BAR 450mm
165CONCEALED STOP COCK, REGULAR BODY FOR 20
166HAND SHOWER (HEALTH FAUCET) WITH 8MM DIA
167WASTE COUPLING 32MM SIZE FULL THREAD WIT
168BOTTLE TRAP (WITH INTERNAL PARTITION) 32
169ORISSA PAN, SIZE: 580*445*260
170BIB COCK WITH NOZZLE & WALL FLANGE
171RIMLESS BOWL FOR COUPLED WC WITH UF SOFT
172WALL HUNG BASIN WITH FIXING ACCESSORIES,
173UNDER COUNTER BASIN, SIZE: 595X410X200mm
174FLASH TOUCH-FREE INFRARED HAND DRYER WIT
175CONTROL PLATE OPAL
176SINGLE PIECE SLIM CONCEALED CISTERN BODY
177SINGLE PIECE SLIM CONCEALED CISTERN WITH
178MAZE OVERHEAD SHOWER Ø150mm ROUND SHAPE
179ANGULAR STOP COCK WITH WALL FLANGE
180EXPOSED PART KIT OF CONCEALED STOP COCK
181PILLAR COCK,AUTO CLOSING SYS.
182AUTO CLOSING URINAL FLUSH VALVE
183SHOWER ARM 20mm DIA & 450mm LONG ROUND S
184RIMLESS, BLIND INSTALLATION WALL HUNG WC
185URINAL, SIZE:355X345X535 mm
186GRAB BAR VERTICAL SWING
187SEPTIC TANK Earth work in excavation by mechanical means (Hydraulic excavator) I manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. 0.00-1.50m
188Earth work in excavation by mechanical means (Hydraulic excavator) I manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. 1.50-3.00m
189Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
190Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 Cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size).
191Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site All works up to plinth level.(FLOOR )
192Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site WALLS
193Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site Cover Slab (2.4*4.4*0.12)
194Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns, etc. for massconcrete.
195Centering and shuttering including strutting, propping etc. and removal of form for: Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
196Centering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platform.
197Edges of slabs and breaks in floors and walls. Under 20 cm wide
198Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars.( 1 % of RCC )
19962 mm thick cement concrete flooring with concrete hardener topping under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume. Hardening compound is mixed @ 2 litre per 50kg of cement or as per manufactures specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
2006 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand)
201Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality HD-20 Circular shape 560 mm internal diameter
202Providing orange colour safety foot rest of minimum 6 mmthick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing,
203Providing and fixing soil, waste and vent pipes 100 mm dia. Centrifugally cast (spun) iron socketed pipe as per IS: 3989.
204RAIN WATER HARVESTING Earth work in excavation by mechanical means (Hydraulic excavatior)/manual means over areas(exceeding 30cm in depth. 1.5m in width as well as 10sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. In all kind of soil upto 1.5m depth
205Earth work in excavation by mechanical means (Hydraulic excavatior)/manual means over areas(exceeding 30cm in depth. 1.5m in width as well as 10sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. In all kind of soil upto 1.5m depth In all kind of soil upto 1.5m to 3.0m. depth
206Earth work in excavation by mechanical means (Hydraulic excavatior)/manual means over areas(exceeding 30cm in depth. 1.5m in width as well as 10sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. In all kind of soil upto 1.5m depth In all kind of soil upto 3.0m to 4.5m. depth
207Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) and curing complete,including cost of form- work, in foundation and floors.
208M-150 brick work in 1:4 (one cement and six coarse sand sand of 2.25 fineness modulus) mortar in foundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work.
209R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in Slab and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20
210Fe-500 Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level.
21115 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 4 Coarse sand
212Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design:With 20x20mm square bar
213Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. H.D. -20- Circular shape 560mm internal diameter
214Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-incharge, upto 90 metre depth below ground level. Drilling of 300mm dia bore hole.
215Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 200 mm nominal size dia
216Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
217Supplying, filling, spreading & leveling gravels of size range 5 mm to 10mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
218Supplying, filling, spreading & leveling coarase sand of size range 1.5 mm to 2mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer-in-charge.
219Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/medium/coarse, in required grading & size as per actual requirement, all complete as per direction of Engineer-in-charge.
220Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (D.S.R.2023/19.32.1)
221External Sewerage(CPWD PAR 2023/5.3)
222INTERNAL ELECTRIFICATION Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit with modular switch modular plate suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc.as required.Group C
223Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
224Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.
225Wiring for power plug points with 2 x 4 sq.mm. FRLS PVC insulated, Cu. Conductor, single core cable in surface/ recessed steel conduit along with 1 No. 4 sq.mm. FRLS PVC insulated copper conductor single core cable for loop earthing as required.
226Wiring for light plug points / power plug points with 4 x 4 sq.mm. FRLS PVC insulated, Cu. Conductor, single core cable in surface/ recessed steel conduit along with 2 Nos. 4 sq.mm. FRLS PVC insulated copper conductor single core cable for loop earthing as required.
227Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed Steel conduit as required 2 x 1.5 sq.mm. + 1 x 1.5 sq.mm. earth wire.
228Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed Steel conduit as required 2 x 2.5 sq.mm. + 1 x 2.5 sq.mm. earth wire.
229Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed Steel conduit as required 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire
230Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed Steel conduit as required 2x10 sq. mm + 1x6 sq. mm earth wire
231Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed Steel conduit as required 4 X 6 sq. mm + 2 X 6 sq. mm earth wire
232Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
233Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
234Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required.
235Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
236Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet (near equipment point) and 25 A modular SP MCB, “C” curve (at accessible point) including connections, painting etc. as required.
237Supplying and fixing of following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 1or 2 module (75mmx 75mm)
238Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
239Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
240Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
241LED Down lighter (SMD Type) (System lumen efficacy ≥ 105 < 120 lm/Watt ) Supplying, Installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body aterial with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim 12 - 15 watt
242LED Down lighter (COB Type) (System lumen efficacy ≥120 lm/Watt ) Supplying, Installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round /square/ Rectangular) COB Type of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumptionshould not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. EM must have its own in house NABL lab setup for all testing facilities for LED fixtures. \\"complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & M80Test report and all testing required for LED fixtures as per BIS shall be submitted Shape sizeand CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector 12 - 15 watt
243LED Batten light (System lumen efficacy ≥105 <120 lm/Watt) Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard DeviationColour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) 18-22 Watt
244Supply, Installation, Testing and Commissioning 240 watt surface mounted Anti Glare Flood Light (System lumen efficacy ≥105 <120 lm/Watt) with MOSO Driver , IP 66/67 Certified protection , CCT 5700K , Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty.Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. Make - NEWBIE TECHNOLOGY PVT LTD.
245Supply, Installation, Testing and Commissioning 100 watt surface mounted Anti Glare Batton Light 1200mm (System lumen efficacy ≥105 <120 lm/Watt) with MOSO Driver , IP 66/67 Certified protection , CCT 5700K , Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty.Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. Make - NEWBIE TECHNOLOGY PVT LTD.
246Supply, Installation, Testing and Commissioning 1.2 HP automatic water pressure booster pump designed for domestic and light commercial use. Motor Power: 1.2 HP (0.9 kW), single-phase Flow Rate: Rated for 4,700 liters per hour (4.7 m³/h) Max Head: ~38.6 to 46 meters (suitable for multi-story supply) Tank Capacity: paired with a 24-liter or 60-liter pressure tank Pressure Rating: Maximum operating pressure of 10 bar Make& Model : Grundfos CMB 5-46
247Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
248Installation, Testing and Commissioning of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. asrequired. Upto 450 mm sweep
249Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
250Supply of 250 mm sweep metallic body Exhaust fan with all accessories suitable for operation single phase 230 volt 50 cycle per sec. as required. in the existing opening, testing, commissioning etc. as required.SPECS : 100 Watts , 2800 RPM , 2100 CMH , SS blades with Grill , with built-in auto-cut thermal protection to prevent overheating , Make - Wadbros or Equivalent
251Supply of 150 mm sweep In-Line Duct Exhaust fan with Double Ball Bearing Motor suitable for operation single phase 230 volt 50 Hz. as required. in the existing Line, testing, commissioning etc. as required.50 Watts , 2600 RPM , 500 CMH , Noise level - 35 dBA , with built-in auto-cut thermal protection to prevent overheating , Make - Wadbros , Model - IL 15
252Supply of 150 mm Disc Valve Diffuser suitable for Ceiling Mount in already placed 150mm Duct as required. in the existing Line, testing, commissioning etc. as required. Make - Wadbros 6\\" White
253Supply of 150 mm Stainless Steel Cowl suitable for Wall Mount in already placed 150mm Duct as required. in the existing Line, testing, commissioning etc. as required. Make - Wadbros Vent SS 6\\" Cowl
254Supplying, laying/ fixing, testing and commissioning of 150 MM nominal sizes PVC piping inside the building (with necessary clamps, vibration isolators and fittings such as bends,tees etc. but excluding valves, strainers, gauges etc.) including repairing of damage to building etc. as per specifications and as required complete in all respect.Complete with Installation of required Diffusers , Cowls and In line Exhaust Fans as per approved drawings and specifications of E.I.C.
255DISTRIBUTION BOARDS Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way, Double door
256Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double door
257Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 Way (4+24), Double Door
258Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required. For 8 way, Double door SPN MCBDB
259Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface / recess, complete with testing and commissioning etc.as required. For 8 way, Double door TPN MCBDB
260Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
261Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
262Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole with neutral
263Supplying and fixing of following rating double pole (Single phase and neutral) 240 volts, residual current circuit breaker (RCCB), having a current sensivity current 30 miliampere in the existing MCB DB complete with connections, testing & commissioning etc. as required. 25 Amps
264Supplying and fixing of following rating double pole (Single phase and neutral) 240 volts, residual current circuit breaker (RCCB), having a current sensivity current 30 miliampere in the existing MCB DB complete with connections, testing & commissioning etc. as required. 40 Amp
265Supplying and fixing of following rating double pole (Single phase and neutral) 240 volts, residual current circuit breaker (RCCB), having a current sensivity current 30 miliampere in the existing MCB DB complete with connections, testing & commissioning etc. as required. 63 Amp
266Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
267CONTROL PANELS Fabrication, supplying, Installation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter-connection withsuitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required INCOMING 250A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Digital Ammeter (0-250 A) with selector swtich & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 300A OUTGOING ( Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps) Main Fire Pump 125 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 60 HP pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. 63 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. Control for diesel engine comprising - Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter,and 0-20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System ControllerDesigning, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification Complete Panel
268EARTHING AND LIGHTNING PROTECTION Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
269Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
270Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
271CABLES, CABLE TRAY'S, RACE WAYS Supplying of 1.1kV grade, heavy duty XLPE insulated PVC Sheathed Aluminum Conductor FRLS type armoured cables suitable for 415V, 50Hz, AC system, with inner and outer PVC sheath, outer sheath provided with FRLS insulation, galvanised steel armouring (round or flat as mentioned)as required.3.5 core, 50 sq.mm.
272Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5 core, 50 sq.mm.
273Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 3½ X 50 sq. mm (35mm)
274Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm width x 50 mm depth x 1.6 mm thickness
275Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. upto 35 sq. MM
276Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design : Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Extra for depth beyond 45 cm of brick masonry chamber For 455x610 mm size
277Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design : Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
278Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 90 mm dia (OD-90 mm & ID-76 mm nominal)
279CCTV CAMERA Supplying Installation Testing and Commissioning of 5/6MP IP IR Dome Camera having following specifications and features etc :- 1)Type of Camera: Dome Camera 2) Image Sensor: 1/2.8\\" or better progressive Scan CMOS get color image even at night condition 3) Signal System: PAL/NTSC 4) Minimum Illumination: 0.008Lux@ F1.4, AGC ON, 0 lux with IR or better 5) Imaging: 1/3s to 1/30000s Shutter Support, Auto Gain Control , White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking. 6) On Screen Display: Camera should display Camera title, Date & Time in live & recorded video both. 7) Signal to Noise Ratio: > 50 dB 8) Day & Night: True Day & Night High Performance Mechanical IR cut filter with auto switch, IR Source- Inbuilt IR LED's with effective distance upto 50 Mtrs integrated IR 30 Mtrs for colour view in night. 9) Video Compression (Minimum): H.265 or better, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.723 10) Wide Dynamic Range: WDR (120dB or more) 11) Digital Noise Reduction: DNR (2D/3D) On/Off 12) Streaming: Triple streaming, configurable 13) Video Streaming & Frame Rates: Triple streaming , configurable Main stream: 5/6MP @25/30 fps, Sub streams: D1@25/30 fps or better 14) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser 15) Profile Management: User configuration import, export 16) Security: User Authentication, Water Marking 17) Onboard Storage: Camera should support built-in Micro SD/SDHC/SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memory Card. 18) Recording Management: Format SD, overwrite, storage management, video to NAS device,19) Edge Analytics : Tripwire, Intrusion, Motion Detection 20) Alarm Trigger : Motion/tampering detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection 21) Alarm Support: It should have 1/1 Alarm In/ Out Port 22) Audio Support: It should have 1x Built-In Mic and 1/1 Audio In/ Out Port for external Mic. and Speaker (As per site requirement) with G.711U/A/ G.711Mu/ AAC/ G.726 audio compression 23) Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast, 24) System Capability: ONVIF 25) VMS: Camera shall support open source VMS 26) Cyber Security: trusted boot, AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, , account lockout, video encryption, IP/MAC filtering, HTTPS, trusted upgrade. 27) Ethernet: 1 RJ 45 10/100 Ethernet port as per DSR 40.5.1
280Supplying Installation Testing and Commissioning of following Channel Network Video Recorder (NVR) with camera licenses to record for all channels havingspecifications and features etc as mentioned below : 16 Channel Network Video Recorder (NVR) having display split :- Main screen: 1/4/8/9/16, 2nd screen: 1/4/8/9/16 as per specification DSR 40.10.2
281Supplying, Installation, Testing and Commissioning following capacity Serveillance grade Hard Disk with upto 256MB/s Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inch form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL Certifications. 8TB (Terabytes)
282Supplying, installation, Testing and commissioning of following capacity 8 port Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under: Minimum 8 X RJ-45 Gigabit Ethernet Ports and additional 2 X 1G SFP Ports with non-blocking architecture by having Switching capacity of minimum 20Gbps and packet forwarding rate of 14Mpps or higher, 8K MAC table. Internal dual AC Power supply with operating temperature of -5 0C to +50 0C. Jumbo frame: 10KB or higher, IGMP Snooping, IGMP snooping querier and support for IGMP Snooping Fast Leave, Should create 250 or more MLD groups, MLD Snooping, Per VLAN MLD Snooping C MLD Snooping Fast Leave, STP, RSTP, MSTP, Loopback detection, Multicast filtering, VLAN Tagging, ǪOS: 8 Ǫue per port, WRR, IPv4/IPv6 Interface : minimum 100 IPv4 static route entries and minimum 50 IPv6 static route entries, 700 Acess Control entries, SSH CSSL for IPv4 and IPv6, 802.1x, ARP Spoofing, DHCP Snooping and server screening, IP+MAC+Port Binding, Per Port Bandwidth Control, 802.1X Authentication (Supports local/RADIUS database, Port-based Access Control and EAP, OTP, TLS, TTLS, PEAP Support) Cable Diagnostic feature, LLDP, LLDP-MED, SNTP/NTP, RMON, SNMP v1,v2c, v3 and SNMP Traps. Certifications: UL, CE, FCC, RoHS, MTCTE, OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. complete as required. 8 port PoE Layer 2 Network Switch with PoE Support of 130W or higher with each copper port supporting 802.3at PoE+.
283Supplying, installation, Testing and commissioning of following capacity 8 port Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under: Minimum 8 X RJ-45 Gigabit Ethernet Ports and additional 2 X 1G SFP Ports with non-blocking architecture by having Switching capacity of minimum 20Gbps and packet forwarding rate of 14Mpps or higher, 8K MAC table. Internal dual AC Power supply with operating temperature of -5 0C to +50 0C. Jumbo frame: 10KB or higher, IGMP Snooping, IGMP snooping querier and support for IGMP Snooping Fast Leave, Should create 250 or more MLD groups, MLD Snooping, Per VLAN MLD Snooping C MLD Snooping Fast Leave, STP, RSTP, MSTP, Loopback detection, Multicast filtering, VLAN Tagging, ǪOS: 8 Ǫue per port, WRR, IPv4/IPv6 Interface : minimum 100 IPv4 static route entries and minimum 50 IPv6 static route entries, 700 Acess Control entries, SSH CSSL for IPv4 and IPv6, 802.1x, ARP Spoofing, DHCP Snooping and server screening, IP+MAC+Port Binding, Per Port Bandwidth Control, 802.1X Authentication (Supports local/RADIUS database, Port-based Access Control and EAP, OTP, TLS, TTLS, PEAP Support) Cable Diagnostic feature, LLDP, LLDP-MED, SNTP/NTP, RMON, SNMP v1,v2c, v3 and SNMP Traps. Certifications: UL, CE, FCC, RoHS, MTCTE, OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. complete as required. 8 port Layer 2 Non-PoE Network Switch
284Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required. 6U RACK
285Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force : 11.5Kg etc. complete as required.1 Run of cable
286Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force : 11.5Kg etc. complete as required. 2 Run of cable
287Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force : 11.5Kg etc. complete as required. 3 Run of cable
288Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force : 11.5Kg etc. complete as required. 4 Run of cable
289Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
290Supplying, Installation, Testing and commissioning of RJ45 Connector for CAT 6/6A Cables. RJ45 modular plug supports 4 twisted pairs, 8 positions, 8 connectors. Housing: PC, UL94V-2, transparent color, Use for 24- 26 AWG stranded wires etc. complete as required.
291Extra for Moving LT Pole on Site
292Building and Washrooms Repair & Maintenance @ 20 % for 1st year
293Building and Washrooms Repair & Maintenance @ 20 % for 2nd year
294Building and Washrooms Repair & Maintenance @ 20 % for 3rd year
295Building and Washrooms Repair & Maintenance @ 20 % for 4th year
296Building and Washrooms Repair & Maintenance @ 20 % for 5th year
297Swimming Pool For Repair and Maintance of complete mechanical equipments , plumbing , electrical panels etc for ITEM 9 above for span of 5 years with a mendatory Monthly visit to site to assess wear and tear and replacement of parts where ever necessary to achieve ideal running conditions of pool .( except in case of vandalism) Monthly visit charges for 1st year
298Extented warranty on the MEP works of the Pools @ 10% of project cost with 10% increment every year from 2nd year to 5th year only (As per qoutation) for 2nd year
299Extented warranty on the MEP works of the Pools @ 10% of project cost with 10% increment every year from 2nd year to 5th year only (As per qoutation) for 3rd year
300Extented warranty on the MEP works of the Pools @ 10% of project cost with 10% increment every year from 2nd year to 5th year only (As per qoutation) for 4th year
301Extented warranty on the MEP works of the Pools @ 10% of project cost with 10% increment every year from 2nd year to 5th year only (As per qoutation) for 5th year
302For Repair and Maintance of complete pool construction @ 20 % for 1st year
303For Repair and Maintance of complete pool construction @ 20 % for 2nd year
304For Repair and Maintance of complete pool construction @ 20 % for 3rd year
305For Repair and Maintance of complete pool construction @ 20 % for 4th year
306For Repair and Maintance of complete pool construction @ 20 % for 5th year
307Supply of PH increasernly of Pool Chemicals @ 10% rate increment every year 50.00kg, PH decreaser 100.00kg, TCCA 90 / Calcium Hypochloride 250.00kg, Non-Ferric Aluminium Sulphate 50.00kg for 1st year
308Supply of PH increasernly of Pool Chemicals @ 10% rate increment every year 50.00kg, PH decreaser 100.00kg, TCCA 90 / Calcium Hypochloride 250.00kg, Non-Ferric Aluminium Sulphate 50.00kg for 2nd year
309Supply of PH increasernly of Pool Chemicals @ 10% rate increment every year 50.00kg, PH decreaser 100.00kg, TCCA 90 / Calcium Hypochloride 250.00kg, Non-Ferric Aluminium Sulphate 50.00kg for 3rd year
310Supply of PH increasernly of Pool Chemicals @ 10% rate increment every year 50.00kg, PH decreaser 100.00kg, TCCA 90 / Calcium Hypochloride 250.00kg, Non-Ferric Aluminium Sulphate 50.00kg for 4th year
311Supply of PH increasernly of Pool Chemicals @ 10% rate increment every year 50.00kg, PH decreaser 100.00kg, TCCA 90 / Calcium Hypochloride 250.00kg, Non-Ferric Aluminium Sulphate 50.00kg for 5th year
312Repair & Maintenance @ 20 % of Plumbing work for 1st year
313Repair & Maintenance @ 20 % of Plumbing work for 2nd year
314Repair & Maintenance @ 20 % of Plumbing work for 3rd year
315Repair & Maintenance @ 20 % of Plumbing work for 4th year
316Repair & Maintenance @ 20 % of Plumbing work for 5th year
317Repair & Maintenance @ 60 % of Electrical work for 1st year
318Repair & Maintenance @ 60 % of Electrical work for 2nd year
319Repair & Maintenance @ 60 % of Electrical work for 3rd year
320Repair & Maintenance @ 60 % of Electrical work for 4th year
321Repair & Maintenance @ 60 % of Electrical work for 5th year
322Complete Operations @ 2496.00 Per day ( Analysis ) for 5 years Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56807919
AUTHORITY Local Bodies
TENDER VALUE 4.10 Crore
LAST DATE 21-08-2026
Authority
Authority Name Special Area Development Authority
Work Description Tender for Construction And Maintenance Of A Swimming Pool At The Sports Stadium Located In The Karwi Urban Area Of ​​Chitrakoot District
Basic Detail
Tender No 802/Nirman/2026-27 Dt. 31-07-2026
Bidding Type Tender
Location
City Chitrakoot
State Uttar Pradesh
Key Dates
Publish Date 03 Aug 2026
Submission Date 21 Aug 2026
Open Date 21 Aug 2026
Finance
Tender Value 4.10 Crore
Tender Fee 5900
EMD 8.20 Lakhs
Exemption Not Available
Document List
5abdbfa5-c4a5-423e-a9a2-43d25ce634e4.html
BOQ_2206392.xls
Tendernotice_1 (29).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 03, 2026
11:30 IST

Tender Published

Tender notice published.

Today
Aug 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Aug 21, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 18 days

Tender Documents

Download All (ZIP) ↓
html

5abdbfa5-c4a5-423e-a9a2-43d25ce634e4.html

xls

BOQ_2206392.xls

pdf

Tendernotice_1 (29).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders