Tender For Providing Ei, Fans, Earthing And Sac At New Te Building Sakrar, Jhansi.
Tender Value
1.85 Lakhs
Estimated cost
Bid Submission
11 Aug 2026
7 days left
EMD
3710
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jhansi → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Providing Ei, Fans, Earthing And Sac At New Te Building Sakrar, Jhansi.
BOQ
| Sl. No. | Item Description |
| 1 | SH:I (Electrical Installations) :: Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required. [a] 3x1.5 sqmm. |
| 2 | [b] 3x4 sqmm. |
| 3 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) [a] 4 way (4 + 12), Double door. |
| 4 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. [a] Single pole |
| 5 | [b] Triple pole and Neutral |
| 6 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. [a] 100 A |
| 7 | Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE armered al conductor power cable of 1.1 kV grade of following size in the existing pole/masonry open duct/in air etc. complete as required. [a] 4 X 16 sq. mm |
| 8 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. [a] 4 X 16 sq. mm |
| 9 | Supplying and Laying of 20mm. dia.PVC flexible conduit pipe from existing MS conduit to TPDB for drawing of wires etc. as reqd. |
| 10 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 11 | Supply, Installation, Testing and Commissioning of 4 feet, 20 Watts (+/- 2 Watts) energy efficient linear box LED batten light having 6500K colour temp., minimum 1900 Lumens, 95 Lumen/watt efficacy and 0.9 power factor along with all accessories suitable for operation on 230 Volts, 50 Hz Single Phase AC Supply complete as required. |
| 12 | S/F 1200 mm. sweep energy efficient AC ceilling fan on suitable 10 mm MS hook/Fan box with suitable screw/ brackets i/c connection testing etc as reqd. (M/s. Khaitan/ Bajaj/Havells/SS make). |
| 13 | Earthing with GI earth pipe 4.5 m long X 40 mm dia including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke & salt as required. |
| 14 | Providing and laying earth connection from earth elecrode with 6 SWG dia GI wire in 15mm dia GI pipe from earth electrode including connection with G.I. thimble excavation and refilling as required. |
| 15 | Supply and Installation of 6 Kg. capacity ABC dry powder stored pressure type fire extinguisher i/c first charging along with nozzle and delivery hose complete in all respect confirming to IS:15683. This also include fixing it with the help of suitable size clamps etc.complete as required. |
| 16 | S/F 15 Amp. plastic Modular box with one no. 15 A piono switch and one no. 15 Amp 5 pin socket i/c connection testing etc as reqd. |
| 17 | SH:II (Air conditioning units) :: Supplying of 1.5 TR Inverter type Split AC units/Ductable Split AC units, remote control unit, filters, rotary type compressor, copper tubes for both indoor and outdoor unit, topping up of refrigerant if required, transportation of all of the above to the various sites etc as required . |
| 18 | Installation, Testing and Commissioning of above 1.5 TR Inverter type Split AC units/ Ductable Split AC units, suitable size of PVC insulated cord wire and PVC drain pipe. including transportation, gas charging, insulation, and making opening in wall and making good the damages etc., complete as per specifications, terms and conditions attached as required. |
| 19 | Providing and fixing the following additional items suitable for the above AC units where ever required:- [a] Supplying and fixing of the suitable size copper pipe line both for gas line and for liquid line OR suitable dia [as recommended by the manufacturer] to match with the pipeline of the new unit along with suitable size rubber foam on surface of the wall i/c necessary flare nuts, suitably brazing with the existing pipe clamping, making holes in walls, same etc., as per site reqirement. |
| 20 | [b] 3x2.5 sqmm PVC insulated copper condr. Flexbile cable. |
| 21 | [c] S/F Suitable dia plastic drainage pipe etc. complete as reqd. |
| 22 | [d] Heavy Duty Powder coated M.S. Stand for outdoor unit. |
| 23 | Supplying and fixing DP sheet steel encosure on surface/ recess along with 25/32 A, 240 V \\"C\\" curve DP MCB with connections, testing and commissioning etc. as required. |
| 24 | Providing and fixing of air conditioning automatic changeover timer switch suitable for 02 Nos. AC units with inbuilt contactor, MCB etc. wall mounted type, auto/ manual i/c connection, testing etc. as reqd. (One timer to be used for Two AC units). Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 03, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 11, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysAug 12, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender