Defence Statutory Bodies & Commissions/Committees Closing in 11 days TDR #56806209

Tender For Completion Of Incomplete Work Including Reconstruction Of Buildings To Be Demolished For Provision Of Klp Accn For Fd Hospital Ex 9 Inf Div At Meerut (At Risk & Cost Of M/S Builders India)

Issued by Statutory Bodies & Commissions/Committees · Meerut, Uttar Pradesh
Tender Value
24.90 Crore
Estimated cost
Bid Submission
15 Oct 2026
11 days left
EMD
15 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Meerut → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Completion Of Incomplete Work Including Reconstruction Of Buildings To Be Demolished For Provision Of Klp Accn For Fd Hospital Ex 9 Inf Div At Meerut (At Risk & Cost Of M/S Builders India)

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 17-Sep-2026 Amendment to date as on 17 Sep 2026 Date 07-Oct-2026
2 10-Sep-2026 AMDT to date Date 25-Sep-2026
3 25-Sep-2026 Amendment to date as on 25 Sep 2026 Date 15-Oct-2026
4 31-Aug-2026 Amendment to date as on 31 Aug 2026 Date 18-Sep-2026
5 10-Sep-2026 AMDT to date Date 25-Sep-2026

BOQ

Name of Work:- COMPLETION OF INCOMPLETE WORK INCLUDING RECONSTRUCTION OF BUILDINGS TO BE DEMOLISHED FOR PROVISION OF KLP ACCN FOR FD HOSPITAL EX 9 INF DIV AT MEERUT (AT RISK & COST OF M/S BUILDERS INDIA)
Sl. No. Item Description
1SCHEDULE 'A' PART-I (BUILDING WORK)Re-construction of block of single living Accn of officers (1 Maj +3 Capt) including Garrage (3 Cars) complete all as shown on drawings and as specified. (Group II)
2Re-construction of block of Servant Qtr (9 +3) (single storey) complete all as specified as shown on drawings and as specified.(Group II)
3Re-construction of block of Officer Mess 16 Officers complete all as specified as shown on drawings and as specified.(Group II)
4Re-construction of block of open Garrage with Apron for Offr's Mess (Car 4 Nos) complete all as specified as shown on drawings and as specified.
5Re-construction of block of JCO Mess for 16 JCO's (D/S + single living Accn for JCO's scooter shed complete all as specified as shown on drawings and as specified (Group II).
6Re-construction of block of Single living Accn for 37 HAV & 107 ORs Dining hall ,kitchen & Cook House storage Accn ration Accn Ration Store drying & ironing shed tradesman shop (Triple Storey) complete all as specified as shown on drawings and as specified.(Group II)
7Re-construction of block of ORs institute + Education building complete all as specified as shown on drawings and as specified. (Group II)
8Re-construction of block of Adm & Working Accn (Double Storey) complete all as specified as shown on drawings and as specified.(Group II)
9Re-construction of block of Parking space for Adm (4 nos. Car /Scooter & Cycle) complete all as specified as shown on drawings and as specified.
10Re-construction of block of Guard house and ancillaries (100-350) etc complete all as specified as shown on drawings and as specified.(Group II)
11Re-construction of block of Covered Accn for MT Veh : block 1 with apron complete all as specified as shown on drawings and as specified.
12Re-construction of block of Covered Accn for MT Veh : block 2 with apron complete all as specified as shown on drawings and as specified.
13Re-construction of block of Covered Accn for MT Veh : block 3 with apron complete all as specified as shown on drawings and as specified.
14Re-construction of block of Repair bays & inspection pit (one bay with inspection pit) complete all as specified as shown on drawings and as specified.
15Re-construction of block of MT storage & Bty charging shops complete all as specified as shown on drawings (Group II)
16Re-construction of block of MI Room X-Ray & pathology FD Hospital complete all as specified as shown on drawings and as specified.(Group II)
17Re-construction of block of Parking space (for MI room & field Hospital) 1 truck, 4 Nos Car, 1 Ambulance, 30 Scooter & 20 cycles with apron complete all as specified as shown on drawings and as specified.
18Re-construction of block of Religious institute Hall (Single storey) complete all as specified as shown on drawings and as specified.(Group II)
19Re-construction of block of Parking Shed (for OR's) 50 scooter & 50 cycle with apron complete all as specified as shown on drawings and as specified.(Group II)
20Re-construction of block of Fuel Store complete all as specified as shown on drawings and as specified. (Group II)
21Completion of Incomplete work for Construction of Dhobi ghat -3 stone complete all as specified as shown on drawings and as specified.
22Completion of Incomplete work for Construction of Flag Mast complete all as specified as shown on drawings and as specified.
23Completion of Incomplete work for Construction of Washing plate form (3650 x 9820 mm) including ramp complete all as specified as shown on drawings and as specified.
24Completion of Incomplete work for Construction of Double Ramp complete all as specified as shown on drawings and as specified.
25Construction of Basket ball court complete all as specified as shown on drawings and as specified.
26Construction of Volley ball court complete all as specified as shown on drawings and as specified.
27Construction of Badmintan court complete all as specified as shown on drawings and as specified.
28Construction of Alarm Post complete all as specified as shown on drawings and as specified.
29Construction of Parade Ground complete all as specified as shown on drawings and as specified.
30Construction of Foot ball & Hockey ground complete all as specified as shown on drawings and as specified.
31Completion of Incomplete work for Construction of Garbage Bin (Large) complete all as specified as shown on drawings and as specified.
32Completion of Incomplete work for Construction of Coal and coke yard complete all as specified as shown on drawings and as specified.
33Re-construction of block of Guard Room etc complete all as specified as shown on drawings and as specified. (Group II)
34Completion of Incomplete work for Construction of Static Water Tank 15 KL Capacity complete all as specified as shown on drawings and as specified.
35Completion of Incomplete work for Construction of Static Water Tank 20 KL Capacity complete all as specified as shown on drawings and as specified.
36Completion of Incomplete work for Construction of Incinerator complete all as specified as shown on drawings and as specified.
37Construction of Incinerator complete all as specified as shown on drawings and as specified.
38Completion of Incomplete work for Construction of Sentry box (1250 x 1250 mm) complete all as specified as shown on drawings and as specified.
39Construction of Hard Standing 70 Sqm (40+30) complete all as specified as shown on drawings and as specified.
40Note 1 : (Srl No.1 to 38): Above schedule is not pre-priced by MES and the pre-priced rate indicated as \\"Rs 0.00\\" under Col. 5 siginifies this fact only.Note 2 : (Srl No.1 to 20 & 33): These bldgs shall be executed only after demolition/dismantling of existing structure at site. Demolition / dismantling items shall be paid under respective Schedule seperately.
41Total amount of Sch 'A' Part-II A (Internal Water Supply) (For details see Sch 'A' Part-II A in PDF folder)
42SCHEDULE 'A' PART-II B (INTERNAL WATER SUPPLY)
43S & F Health faucet with 1 mm tube and wall stand and including fixing brackets etc complete all as specified and directed. Make - Hindware F-160059 or equivalent make as specified
44S & F Elbow operated chromium plated fancy Bib tap cast copper alloy with crutch or butter fly handle, screwed down for 15 mm bore GI pipe or for brass ferrule or to GI socket complete all as specified and directed.
45S & F brass CP central hole wash hand basin mixer w/o PUW with 450 mm SS flexible hose sreewed down high pressure screwed for iron pipe etc complete all as specified and directed.
46S & F 15 mm dia brass CP sink mixer with swivel spout wall mounted for mixing hot & cold water screwed down for iron pipe and fixed all as specified and directed.
47S & F 15 mm dia brass CP WALL mixer for over head shower with 115 mm long bend pipe & wall flange for mixing hot & cold water screwed down for iron pipe and fixed all as specified and directed. Make - Hindware cat no F-200020/Jaquar cat no CON 273UPR or equivalent make as specified
48S & F brass CP Pillar tap Fancy type cast copper alloy with crutch or butter fly handle, screwed down, screwed for 15 mm bore GI pipe or for brass ferrule or to GI socket complete all as specified and directed. Make - Hindware cat no F-200001/Jaquar cat no CON 021or equivalent make as specified
49S & F brass, CP Bib tap long body Fancy type cast copper alloy with crutch or butter fly handle, screwed down, screwed for 15 mm bore GI pipe or for brass ferrule or to GI socket with wall flange complete all as specified and directed. Make - Hindware cat no F-200001/Jaquar cat no CON 107 or euivlent make as specified
50S & F fancy type brass angle cock Chromium plated, screwed both ends suitable for 15 mm bore GI pipe complete all as specified and directed. Make - Hindware cat no F-200005/Jaquar cat no CON 053or euivlent make as specified
51S & F fancy type brass stop valve Chromium plated, long shunk concealled type with wheel head, screwed both ends suitable for 15 mm bore GI pipe complete all as specified and directed.
52S & F brass chromium plated shower rose Fancy type, 125 mm dia with or without swivel joints, incl shower arm fixing to 15 mm bore pipe or union complete all as specified.
53Total amount of Sch 'A' Part-III A (INTERNAL ELECTRIFICATION) (For details see Sch 'A' Part-III A in PDF folder)
54SCHEDULE 'A' PART III-B (INTERNAL ELECTRIFICATION)
55M & L for Point wiring with 1.5 Sq mm single core, multi stranded PVC insulated, unsheathed copper conductor cable FRLS and including rigid non metallic concealed conduit 20 mm dia or higher medium grade ISI marked complete with all conduit accessories / fittings and sunk CI/pressed steel terminal switch boxes with 3 mm thick plastic laminated hard glossy surface sheet top cover, concealed in wall including earth wire continuous of PVC insulated, unsheathed 1.5 Sq mm copper conductor, PVC insulated connected to all fittings, sunken boxes and common earth, earth dolly. Plastic laminated sheet screwed with brass screws, cup washers complete all as specified and directed for the following :-
56One light point controlled by one way switch 5/6 Amps
57One fan point controlled by one way switch 5/6 Amps
58One Exhaust Fan point controlled by one way switch 5/6 Amps
59One Bell point controlled by one way switch 5/6 Amps
606 Amps 5 Pin Socket on same board controlled by one switch
616 Amps 5 Pin Socket on independent board controlled by one switch
62One light point controlled by 2 way switch 5/6 Amps.Note (Srl No 55 to 61):- Switch, Socket out let etc will be paid and measured separately.
63M & L for Point wiring with 2.5 Sq mm single core, multi stranded PVC insulated, unsheathed copper conductor cable FRLS and including rigid non metallic concealed conduit 20 mm dia or higher medium grade ISI marked complete with all conduit accessories / fittings and sunk CI/pressed steel terminal switch boxes with 3 mm thick plastic laminated hard glossy surface sheet top cover, concealed in wall including earth wire continuous of PVC insulated, unsheathed 1.5 Sq mm copper conductor, PVC insulated connected to all fittings, sunken boxes and common earth, earth dolly. Plastic laminated sheet screwed with brass screws, cup washers and all accessories for one three pin 15/16 Amp socket outlet point on independent board complete all as specified and directed. Note.- Switch & Socket Shall be measured and paid Separately.
64S & F batton holder with PVC insulated body angular / straight fixed on plastic laminated sheet cover round shape 3mm thick including 1 No CFL 18 watt 230 volt AC integrated circuit retrofit type suitable for 230 volt AC complete all as specified and directed.
65S & F florescent Tubelight 1 x 36 Watt fitting box type complete with all accessories such as electronic choke condenser and florescent Tube rod 36 watt 230 volt fixed on wall / ceiling connected with 3 core 23/0.0076 insulated copper wire from ceiling rose to fitting connector complete all as specified and directed.
66S & F florescent Tubelight 2 x 36 Watt fitting box type complete with all accessories such as electronic choke condenser and florescent Tube rod 36 watt 230 volt fixed on wall/ceiling connected with 3 core 23/0.0076 insulated copper wire from ceiling rose to fitting connector complete all as specified and directed.
67S & F Fluorescent TubeLight fitting decorative box with aluminum reflector complete with electronic choke 1 x 36 W HPF and connected with 3 core 23/0.0076 insulated copper wire from ceiling rose to fitting connector fixed with conduit bell mouth coupler, two Nos down conduits of suitable length and size complete with check nuts and round blocks suitable for 2 x 36 W Tube Light fitting complete with all accessories incl florescent Tube rod complete all as specified and directed.
68S & F Ceiling fitting complete with all accessories such as electronic choke and CFL 3 x 36 W , 230V fixed with on ceiling / roof connected with 3 core 14/0.0076 insulated copper wire from ceiling rose to fitting connector all as specified CAT Part No LHCL 01336425
69S & F Ceiling fitting 1 x 20 W complete with all accessories such as electronic choke, and CFL of 20W 230V fixed on ceiling connected with 3 core 14/0.0076 insulated copper wire from ceiling rose to fitting connector all as specified and directed.
70Supply & fixing security light fitting suitable for 2 x 11 watt CFL and including 2 Nos CFL lamp of 11 watt complete with M & L GI pipe mounting bracket of size 25 / 32 mm dia and 1.20 m long fixed to wall with and including nut, bolts and GI clamps of size 50 x 6 mm as required including two coats of synthetic enameled paint over a coat of primer and making connection with three core 23/.0076 rubber insulated copper cable from ceiling rose to connector of street light complete all as specified and directed.
71S & F mirror light fitting 2 x 18 W complete with all accessories such as electronic choke, and CFL 2 Nos of 18W 230 V fixed on wall connected with 3 core 14/0.0076 insulated copper wire from ceiling rose to fitting connector all as specified and directed.
72M & L for Sub main wiring with four single core, 16 Sqmm, PVC insulated PVC unsheathed stranded copper conductor cable FRLS and including steel concealed/ surface conduit, 25 mm or higher dia, ISI marked, medium grade complete with all conduit accessories / fittings including extension of earth wire with 6 Sqmm single core PVC insulated, unsheathed copper cable fixed along with the sub main in PVC conduit and connecting to earth dolly with all fixing material complete all as specified and directed.
73M & L for Sub main wiring with four single core, 10 Sqmm, PVC insulated PVC unsheathed stranded copper conductor cable FRLS and including steel concealed / surface conduit, 25 mm or higher dia, ISI marked, medium grade complete with all conduit accessories / fittings including extension of earth wire with 4 Sqmm single core PVC insulated, unsheathed copper cable fixed along with the sub main in PVC conduit and connecting to earth dolly with all fixing material complete all as specified and directed.
74M & L for Sub main wiring with two single core, 10 Sqmm, PVC insulated PVC unsheathed stranded copper conductor cable FRLS and including steel concealed/ surface conduit, 20 mm or higher dia, ISI marked, medium grade complete with all conduit accessories / fittings including extension of earth wire with 4 Sqmm single core PVC insulated, unsheathed copper cable fixed along with the sub main in PVC conduit and connecting to earth dolly with all fixing material complete all as specified and directed.
75M & L for Sub main wiring with two single core, 6 Sqmm, PVC insulated PVC unsheathed stranded copper conductor cable FRLS and including steel concealed/ surface conduit, 20 mm or higher dia, ISI marked, medium grade complete with all conduit accessories/ fittings including extension of earth wire with 2.5 Sqmm single core PVC insulated, unsheathed copper cable fixed along with the sub main in PVC conduit and connecting to earth dolly with all fixing material complete all as specified and directed.
76M & L for Sub main wiring with two single core, 4 Sqmm, PVC insulated PVC unsheathed stranded copper conductor cable FRLS and including steel concealed/ surface conduit, 20 mm or higher dia, ISI marked, medium grade complete with all conduit accessories/ fittings including extension of earth wire with 2.5 Sqmm single core PVC insulated, unsheathed copper cable fixed along with the sub main in PVC conduit and connecting to earth dolly with all fixing material complete all as specified and directed.
77M & L for Tripple pole and neutral DB’s, 8 way suitable for mounting MCBs/ Isolators as outgoing and incoming MCCB 125 Amp TP complete vertical load line type including all fixing materials / accessories for double door DB, all as specified and directed. Note : Incoming MCCB and outgoing MCB SP/TP will be measured and paid seperately.
78M & L for Distribution board single pole and neutral 12 way, 240 volts, double door type suitable for mounting incoming and outgoing MCB’s double pole/single pole, 4/8 Nos respectively out going MCB’s. all as specified and directed Note : Incoming and outgoing MCB SP/TP will be measured and paid seperataely.
79All as per Item No 77 but 8 way
80All as per Item No 77 but 6 way
81All as per Item No 77 but 4 way
82S & F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 Amps (for geyser) complete all as specified and directed.
83M & L for Miniature circuit breaker single pole with thermal over load as well as magnetic short circuit tripping device with quick, break trip free mechanism, robust design and terminals having heat resistant moulding suitable for single phase circuit of 240 Volts and 6 to 32 Amps current rating ‘D’ series, 10 KA complete all as specified and directed.
84S & F,Miniature circuit breaker triple pole and neutral with thermal over load as well as magnetic short circuit tripping device with quick, break trip free mechanism, robust design and terminals having heat resistant moulding suitable for three phase circuit of 415Volts and 63 Amps , 10 KA complete all as specified and directed.
85S & F Miniature circuit breaker single pole and neutral (SPN)with thermal over load as well as magnetic short circuit tripping device with quick, break trip free mechanism, robust design and terminals having heat resistant moulding suitable for single phase circuit of 240 Volts and 6 to32 Amps series, 10 KA complete all as specified.
86All as per Item No 84 above but 63 Amps complete all as specified and directed.
87S & F MCCB TP 415 Volts 100 Amps Cap, 25 KA fixed on load line vertical DB TPN complete all as specified and directed.
88Supply & Fixing, Ceiling fan 1200 mm sweep complete with capacitor canopy and down rod including flexible twincore copper (23/0.0076)with provision of ceiling rose/connector to fan all as specified and directed.
89S & F Ceiling fan 1400mm sweep with regulater capacitor canopy and down rod including flexible twincore copper (23/0.0076)with provision of ceiling rose/connector to fan all as specified and directed.
90S & F propeller type AC ventilating fans 300 mm sweep (Exhaust fan) with louver shutter complete including M&L for providing/cutting the round hole of required size in wall finishing the same supply and grouting the ragged bolts in wall, fixing the frame on the exhaust side (outer surface of the wall) and connecting with and including PVC insulated three core 23/.0076 copper cable, rubber insulated from ceiling rose to exhaust fan motor and writing MES No with black synthetic enamel paint 2.0 cm high complete all as specified and directed. Make- Usha/Havells.
91All as per item No. 89 above but 450 mm sweeps complete all as specified and directed.
92M & L for Numbering of all fans / light fitting / geysers / exhaust fans with enamel paint (as per sample) complete all as specified and directed..
93S & F Blanking plate complete all as specified and directed.
94S & F call bell AC 240 V single phase ding dong complete all as specified and directed.
95M & L for Earthing complete with galvanized mild steel earth plate (electrode) 600 x 600 x 6.00 mm thick buried directly in ground, earth pit not less than 2.25 mtr deep below ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all round the plate using 4 mm dia GI wire as earth wire moulded and riveted to earth plate at one end and connected to main switch/control switch of the building at another end, GI earth wire incased in and including 15 mm dia GI ‘light grade’ pipe from upper end of earth plate uopto main switch/control of the building including 20 mm dia bore GI pipe ‘light grade’ as water pipe from earth chamber to upper edge of earth plate, CI funnel with wire mesh fixed on water pipe and provision of PCC chamber and RCC pit cover with lifting handle, excavation, earth work including laying the GI pipe concealed in floor /wall all as described in electrical plate No 3 of SSR Part I.
96S & F earth continity conductor or main earthing lead fixed on wall recasse or chases of buried in ground or drawn in conduite/pipe or fixed to pole or any other indicated situation for loop earthing etc. as buried 4mm dia galvanised iron or steel wire complete all as specified and directed.
97S & F Geysers single phase 230 Volts storage type vertical shape 25 Litrs capacity including necessaryv fittings / fixture complete all as specified and directed.
98S & F electric control panel vertical, three phases distribution board with provision for 4 pole MCCB (T-max / T1 type) upto 200 Amps as in comer & 3 phase and single phase (TP/SP) as out going, with insulated bus bar arrangement for 4 way complete all as directed. (MCCB shall be measured and paid separately)
99M & L of 25 mm dia rigid PVC conduit including sunk boxes (junction / terminal), all tees, bends, elbow, reducer, bell mouth tube ends and all fixing accessories such as coupler, lock nuts sadles, pipe hook complete all as specified and directed.
100M & L for Point wiring, flame proof with 1.5 Sq mm single core, multi stranded PVC insulated, unsheathed copper conductor cable FRLS and including stove enamelled steel concealed conduit 20 mm dia or higher ISI marked complete with all conduit accessories / fittings and sunk CI/pressed steel terminal switch boxes with 3 mm thick plastic laminated hard glossy surface sheet top cover, concealed in wall including earth wire continuous of PVC insulated, unsheathed 1.5 Sq mm copper conductor, PVC insulated connected to all fittings, sunken boxes and common earth, earth dolly. Plastic laminated sheet screwed with brass screws, cup washers complete all as specified and directed for the following :- One light point controlled by one way switch 16 Amps
101Total amount of Sch 'A' Part-IV (Earth work and site clearance) (For details see Sch 'A' Part-IV in PDF folder)
102SCHEDULE 'A' PART V BLANK
103Total amount of Sch 'A' Part VI 'A' (Road, Path & Culvert) (For details see Sch 'A' in PDF folder)
104SCHEDULE 'A' PART VI-B (Road, Path & Culvert)
105M & L Applying thermoplastic reflective paint as in road marking of minium 2.50 mm thick single coat of 100 / 150 mm wide using HOT MARK thermo plastic paint (hot application) white golden yellow by indigenous modern property road marking machine as directed
106Supply and fixing of 3 MUSA brand markers (cat eyes) made of non breakable polycarbonate with electronically welded primatic Retro reflecive in wet and dry condition with dust proof body complete all as specified and directed.
107Construction of RCC hume pipe culvert class NP-2 300mm, internal dia 6.00 m long (in between parapet ) complete all as specified and shown on drgs.
108Construction of RCC hume pipe culvert class NP-2, 450 mm, internal dia 6.00 m long (in between parapet) complete all as specified and shown on drgs.
109Construction of RCC slab culvert in RCC M-25 design mix concrete, 610mm clear span, 7.50 M long complete all as specified and and shown on drgs.
110Construction of RCC slab culvert in RCC M-25 design mix concrete, 910 mm clear span, 7.50 M long complete all as specified and shown on drgs.
111M & L for 60 mm thick Rubber moulded interlocking tiles laid dry over sand cushioning complete all as specified and directed
112Supply and install box type glow sign board of size 1.2m x1.5m, made out of angle iron framed and fixed of white colour acrulic cover both side (front and rear) complete oponable including two number FTL fitting 2 x 40 watt fixed inside board and connected with 3 core cable 4 sqmm from nearest electric point to the board and controlled by one MCB SPN 10 Amp complete including writing work all as specified and directed
113S & F Delinators post of 60 cm height from ground level, black or red colour made of 16 guage 48 mm dia MS round pipe heavy duty incl two coats of powder coated black colour paint over one coat of primer with three reflective device all as per MOST & IRC specification and as directed.
114Total amount of Sch 'A' Part-VII A (Sewage Disposal) (For details see Sch 'A' Part-VII A in PDF folder)
115SCHEDULE 'A' PART VII-B (Sewage Disposal)
116Construction of Septic tank 50 users complete all as specified and shown in drawing No. TD/217-A, sheet 1/1 and TD/217, sheet 1/7 to 7/7 complete all as specified and directed and shown on drawing
117Construction of Septic tank 100 users complete all as specified and shown in drawing No. TD/217-A, sheet 1/1 and TD/217, sheet 1/7 to 7/7 complete all as specified and directed and shown on drawing
118Construction of Septic tank 200 users complete all as specified and shown in drawing No. TD/217-A, sheet 1/1 and TD/217, sheet 1/7 to 7/7 complete all as specified and directed and shown on drawing
119Construction of brick masonry soak well of 1.80 mtr dia & 6 mtr effective depth complete all as specified and directed and shown on drawing
120Construction of brick masonry soak well of 2.40 mtr dia & 6.0 mtr effective depth complete all as specified and directed and shown on drawing
121Construction of brick masonry soak well of 1.80 mtr dia & 4.50 mtr effective depth complete all as specified and directed and shown on drawing
122Total amount of Sch 'A' Part - VIII (Area Drainage) (For details see Sch 'A' Part-VIII in PDF folder)
123Total amount of Sch 'A' Part - IX A (Fencing, Compound Wall & Gate) (For details see Sch 'A' Part-IX A in PDF folder)
124SCHEDULE 'A' PART IX-B (Fencing, Compound Wall & Gate)
125Construction of Steel gate 6.00 mtr wide (clear distance between RCC pillar to RCC pillar) 2.45 mtr high complete all as specified and directed and shown on drawing.
126Total amount of Sch 'A' Part - X A (External Water Supply) (For details see Sch 'A' Part-X A in PDF folder)
127SCHEDULE 'A' PART X-B (External Water Supply)
128M & L for providing lowering in trenches, laying and jointing ductile iron pipe (K-9), socket and spigot end, as per specifications (IS-8329) with internal cement mortar lining and external bitumen coating for portable water supply with rubber ring joints, including cost of rubber rings as per IS:5382 (1985), giving satisfactory hydraulic field testing and commissioning as per Technical specification etc complete of 80mm dia complete all as specified and directed.
129M & L for providing lowering in trenches, laying and jointing ductile iron pipe (K-9), socket and spigot end, as per specifications (IS-8329) with internal cement mortar lining and external bitumen coating for portable water supply with rubber ring joints, including cost of rubber rings as per IS:5382 (1985), giving satisfactory hydraulic field testing and commissioning as per Technical specification etc complete of 100mm dia complete all as specified and directed.
130M & L for providing lowering in trenches, laying and jointing ductile iron pipe (K-9), socket and spigot end, as per specifications (IS-8329) with internal cement mortar lining and external bitumen coating for portable water supply with rubber ring joints, including cost of rubber rings as per IS:5382 (1985), giving satisfactory hydraulic field testing and commissioning as per Technical specification etc complete of 150mm dia complete all as specified and directed.
131Supply, laying in trenches and testing MS heavy duty ERW Steel pipe 5.40mm thick welded in any shape and making bends etc including flange 10 mm thick both end including two coat of rubber black paint in outer all complete with fittings etc for following sizes complete all as specified and directed.
132150 mm dia
133200 mm dia
134Supply,laying and testing of cast iron sluice valves of class PN1.6, conforming to relevent IS 14846 including , flanged ends, drilled having stainless steel spindle(ISI Marked) with cast iron wheel at top complete with nut bolts, washer and rubber gasket complete all as specified for following:-
135150mm dia Qty - Nil
136100mm dia Qty - Nil
13780mm dia
138S & F for DI special bends (any radius and angle), tapers any type,(straight, bend, increasing decreasing of double socket etc.) Tee pieces, single branch Y junction, double branch cross /all sockets or socket and spigot, collars caps and plugs etc suitable upto 150 mm dia bore pipe complete all as specified and directed.
139M&L for construction of brick masonery valve pit of size 800 x 800 x 800 mm.(Internal dimensions) with brick work of sub class 'B' old size bricks built in cement mortar 1:4 and 10mm thick rendering on internal and exposed external surfaces and including 40x40x6 mm mild steel angle frame 3.15 mm thick mild steel sheet cover in two nos shutters with handle and locking arrangement and 1 Nos 50mm size 4 levers lock with key in duplicate make Navtal including painting steel and iron surfaces with two coats of black bituminous paint over a coat of red oxide primer complete all as specified, shown on drawing and complete all as specified and directed.
140M&L for construction of brick masonery valve pit of size 950 x 950 x 950 mm.(Internal dimensions) with brick work of sub class 'B' old size bricks built in cement mortar 1:4 and 10mm thick rendering on internal and exposed external surfaces and including 40x40x6 mm mild steel angle frame 3.15 mm thick mild steel sheet cover in two nos shutters with handle and locking arrangement and 1 Nos 50mm size 4 levers lock with key in duplicate make Navtal including painting steel and iron surfaces with two coats of black bituminous paint over a coat of red oxide primer complete all as specified, shown on drawing complete all as specified and directed. Qty - Nil
141Total amount of Sch 'A' Part-XI A (External Electric Supply) (For details see Sch 'A' Part-XI A in PDF folder)
142SCHEDULE 'A' PART X-B (External Water Supply)
143Supply, fixing, testing commissioning and fabrication of LT out door double door both side openable Panel box (KIOSK) type totally enclosed made of suitable size with MS sheet 3.15 mm thick weather proof having sloping canopy with locking arrangement and painting etc (factory made) comprising the following :- ( MFP )
144(i) Incoming ACB 630 Amps 4 Pole 415 volt with thermal release, -1 No
145(ii) Outgoing MCCB 200 Amps TP 415 volt 36 KA - 2 Nos
146(ii) Outgoing MCCB 100 Amps TP 415 volt 16 KA - 1 Nos
147(iii) Outgoing MCCB 63 Amps TP 415 volt 16 KA - 1 Nos
148(iv) Outgoing MCCB 40 Amps TP 415 volt 16 KA - 2 Nos (Incl one spare)
149(v) Outgoing MCB SPN 40 Amps 230 volt 10 KA - 2 Nos
150(vi) Busbar aluminium 1000 Amps with pvc sheeth insulated for TPN - One set.
151(vii) Digital Multi functional panel mounted meter with CT's - 300/5A in accuraty class 1.0, CT primary programmable upto 6000 A, Measures and displays Phase to Phase voltage, Phase to Neutral voltage, Instatanious average, maximum and total load current,Active power kW, Reactive power kvAR and apparent power KVA, instantanious and total power factor, frequency, RS 485 communication (optional)
152(viii) Indicator lamp neon type - 3 Nos
153(ix) Panel Connection with 2.5 sq mm copper cable PVC single core - 1 Job
154(x) PCC plate form with foundation 1 : 2 : 4 = 1 Job
155(xi) Multifunctional Degital timer switch Astrorex D 22
156(xii) Power contactor of size 40 Amps three pole
157Supply and fix APFC panel , out door type mounted on PCC base with 3 x 50 KVAR power factor correction capacitors and to accommodate and include the following fitments complete:
158(a) MCCB 500 Amps for incoming -01 No
159(b) MCCB 200 Amps for control of 2 x 50 KVAR-02 No
160(c) MCCB 100 Amps for control of 1 x 50 KVAR-01 No
161(d) Phase indicator lamps LED type-01 set of three
162Supply,fixing,testing commissioning and fabrication of LT out door double door both side openable Panel box (KIOSK) type totally enclosed made of suitable size with MS sheet 3.15 mm thick weather proof having sloping canopy with locking arrangement and painting etc (factory made) comprising the following :- (FP-1 )
163(i) Incoming MCCB 200 Amps 4 Pole 415 volt 36 KA-1 No
164(ii) Outgoing MCCB 63 Amps TP 415 volt 16 KA - 1 Nos
165(iii) Outgoing MCCB 40 Amps TP 415 volt 16 KA - 5 Nos
166(iv) Outgoing MCB 32 Amps SPN 230 volt 10KA - 5 Nos
167(v) Busbar aluminium 400 Amps with PVC insulated for TPN - One set.
168(vi) Volt meter 0 - 500 volts with selector switch 1 No.
169(vii) Indicator lamp neon type - 3 Nos
170(viii) Panel Connection with 2.5 sq mm copper cable PVC single core - 1 Job
171(ix) PCC plate form with foundation 1 : 2 : 4 = 1 Job
172Supply, fixing, testing commissioning and fabrication of LT out door double door both side openable Panel box (KIOSK) type totally enclosed made of suitable size with MS sheet 3.15 mm thick weather proof having sloping canopy with locking arrangement and painting etc (factory made) comprising the following :- (FP-2 )
173(i) Incoming MCCB 200 Amps 4 Pole 415 volt 36 KA-1 No
174(ii) Outgoing MCCB 160 Amps TP 415 volt 36 KA - 1 Nos
175(iii) Outgoing MCCB 32 Amps TP 415 volt 16 KA - 2 Nos
176(iv) Outgoing MCB 40 Amps SPN 415 volt 16 KA - 4 Nos
177(v) Multifunctional Degital timer switch Astrorex D 22
178(vi) Power contactor of size 40 Amps three pole
179(vii) Busbar aluminium 400 Amps with PVC insulated for TPN - One set.
180(viii) Digital Multi functional panel mounted meter with CT's - 300/5A in accuraty class 1.0, CT primary programmable upto 6000 A, Measures and displays Phase to Phase voltage, Phase to Neutral voltage, Instatanious average, maximum and total load current,Active power kW, Reactive power kvAR and apparent power KVA, instantanious and total power factor, frequency, RS 485 communication (optional)
181(ix) Indicator lamp neon type - 3 Nos
182(x) Panel Connection with 2.5 sq mm copper cable PVC single core - 1 Job
183(xi) PCC plate form with foundation 1 : 2 : 4 = 1 Job
184Supply,fixing,testing commissioning and fabrication of LT out door double door both side openable Panel box (KIOSK) type totally enclosed made of suitable size with MS sheet 3.15 mm thick weather proof having sloping canopy with locking arrangement and painting etc (factory made) comprising the following :- (FP-3 )
185(i) Incoming MCCB 100 Amps 4 Pole 415 volt 26 KA-1 No
186(ii) Outgoing MCCB 32 Amps TP 415 volt 16 KA - 3 Nos
187(iii) Outgoing MCB/Isolator 40 Amps SPN 415 volt 16 KA - 5 Nos
188(iv) Busbar aluminium 400 Amps with PVC insulated for TPN - One set.
189(v) Indicator lamp neon type - 3 Nos
190(vi) Digital Multi functional panel mounted meter with CT's - 300/5A in accuraty class 1.0, CT primary programmable upto 6000 A, Measures and displays Phase to Phase voltage, Phase to Neutral voltage, Instatanious average, maximum and total load current,Active power kW, Reactive power kvAR and apparent power KVA, instantanious and total power factor, frequency, RS 485 communication (optional)
191(vii) Panel Connection with 2.5 sq mm copper cable PVC single core - 1 Job
192(viii) PCC plate form with foundation 1 : 2 : 4 = 1 Job
193M & L for Earthing complete with GI earth plates electrode 600x600x6mm thick burried directly in ground earth pit not less than 2.25 mtr deep below ground level surrounded with adequate quantity of charcoal dust mixed with salts to a packet thickness of 15 cm all around the plate,using GI earth strip 32x6mm connected to earth plate by means of nut ,bolts and washers as directed GI pipe light grade 50mm bore on water pipe from earth chamber to top most edge of earth plate,CI funnel with wiremesh fixed on water pipe and PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in pit chamber and RCC pitcover 50mm thick pre-cost RCC 1:2:4 type B-1 dully rainforced with MS bars 6mm dia @150 cc both ways with 10mm dia MS bar in lifting handle excavation earth work including laying of GI pipe in walls etcall as directed in electrical plate No 3 of SSR pt I complete all as specified and directed.
194S&F street light fittings HPSV 150 Watts, single piece di cost almn housing and cover vith innovative bright anodised Almn stair case optic lamp compartment, has toughened flat glass cover, IP-66 complete with HPSV Lamp, ballast, Ignitor and other accessories complete all as specified and directed.
195M &L for pole box fabricateed out of 1.8mm thick MS sheet having 3 nos busbar 50Amp copper conductor mounted on insulators one no 20x3mm copper bus bar with 2 clamps of copper strip for earthing of the armoured of the cable complete with making holes for connecting cables etc nuts bolts etc size of box not less then 100x200x80mm front openable hinged cover suitable for mounting on steel using M/S clamps with nut & bolts etc PVC adopters and PVC hose pipe upto cable trench for incoming and outgoing cables, factory made duly painted with powder coating process complete all as specified and directed.
196S & F Post Top lantern with conical cover including GI pipe of suitable size upto 2.5 Mtr length including 1 x 70W MH DE (Housing Cat No. LHLM13170D99G and Ballast Cat No. LHBW07170036) lamp connecting with twin core cable 2.5 sqmm upto post box complete all as specified and directed
197Supply, fixing, connection and testing of integral flood light luminaries type suitable for 2x400 Watts MH lamp fittings with 40 Watts MH lamp and control gear boxes, suitable size of wiring of luminaries and fixture of high mast light complete all as specified and directed.
198Supply and installed MCCB FP 415 volts AC 3 phase 50 HZ 100 Amps capacity 36 KA with sheet metal enclosures on wall /pole -01 No complete with locking arrangement complete all as specified and directed.
199Supply & fixing of Cable route markers made of galvanized iron with supporting GI angle of size 40 X 40 X 6 mm for stand and plate size 150X150X5mm thick and primering, painting, writing of HT/LT cable route mark for suitable size letters including M/L PCC 1:3:6 type C2 using 40mm graded aggregades in mass concrete or plinth block complete all as specified and directed.
200Providing platform for transformer of size 3.0 x 3.0 x 1.0 m high from GL including excavation in trenches not less than 1 mtr, PCC 1:5:10 type E2 for foundation, brick work in cm 1:6, PCC 1:2:4 type B1 in copping, plaster 10mm thick in cm 1:6 om brick /complete surface PCC 1:4:8 type B1 sub base 75mm thick, as in flour PCC 1:2:4 type B1 100mm thick floor using extra cement returning filling and removal on surplus soil, chain link fencing 1.8m high made out of 4mm dia GI wire 150x100mm mesh MS work angle iron 50x50x6mm as fencing post in embeded in brick /PCC work at 2mtr interval each side as approved 1 No steel gate (3.5m clear) span as shown in drawing with locking arrangement made out of 15mm dia ms rod &50x50x6mm angle iron frame . painting with 2 coat alu paint over a coat of red oxide primer and 3 coats of white washing on cement work including 2 Nos ISMB 100mm chanel for fixing transformer including ramp of suitable size mounting of transformer complete all as specified and directed. Qty - Nil
201Total amount of Sch 'A' Part - XII A (Cable Networking) (For details see Sch 'A' Part-XII A in PDF folder)
202SCHEDULE 'A' PART XII-B (Cable Networking)
203M & L for making of point for Telephone with and including telephone socket RJ-11 with metal flush box sand cover plate complete all as specified and directed.
204Total amount of Sch 'A' Part - XIII A (Lightening Protection) (For details see Sch 'A' Part-XIII A in PDF folder)
205SCHEDULE 'A' PART XIII-B (Lightening Protection)
206M & L for Earthing complete with GI earth plates electrode 600 x 600 x 6 mm thick burried directly in ground earth pit not less than 4.50 mtr deep below ground level with top edge of earth plate not less than 1.5m below GL the plate surrounded with adequate quantity of charcoal dust mixed with salts to a packet thickness of 15 cm all around the plate,using GI earth strip 32 x 6 mm connected to earth plate by means of nut ,bolts and washers GI pipe light grade 50 mm bore for protection of strips from edge of earth plate to test point including water pipe of size light grade 50 mm from earth chamber to edge of earth plate,CI funnel with wiremesh fixed on water pipe and PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in pit chamber and RCC pitcover 50 mm thick pre-cost RCC 1:2:4 type B-1 dully rainforced with MS bars 6mm dia @ 150 C/C both ways with 10 mm dia MS bar in lifting handle including excavation earth work etc all as directed in electrical plate No 3 of SSR pt I complete all as specified and directed.
207SCHEDULE 'A' PART XIV (DG Set)
208Supply, Errection, testing and commissioning complete of manufacturer or OEM manufactured, static silent (Sound Proof enclosure) Diesel Engine Driven Generating Set capable of delivering 20.0 KW (25KVA), Air cooled, 415 Volts(AC hree phase, 4 Wire system of supply) 50 HZ at power factor 0.8 minimum. The DG Set shall consists of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with control panel standardised by manufacturer, fuel tank with mounting arrangements and inlet , outlet return inlet oil arrangement, exhaust pipe complete and suitable for conditions prevalent at Meerut (Capacity of Engine, alternators shall be worked out taking all derating factors into consideratuion) including PCC foundation ( of suitable size leaving at least 0.5 M all around for ease of movement and 0.5 M height), antivibration pads,including all features to comply with latest CPCB guidelines and Comprising of followings:-
209(i) ENGINE (Prime Mover): Diesel Engine 1500 RPM , direct injection, four stroke, confirming to ISO3046/BS 5514, water cooled, naturally turbo charged,capabe of giving adequate BHP to drive Alternator capable of delivering 25 KVA(20 KW) at outdoor atmospheric conditions at Meerut (Taking all derating factor into consideration),12/24 Volt(as per manufacturer recommendations) electric battery start, complete with fly wheel all standard fittings/fixtures as per manufacturer and including suitable panel with tachometer, lub oil temperature, pressure guage and frequency meters and also including self starter system, dynamo, fuel electric control panel with electronic governor (ECPG) and Engine protection system(Shut down, High water temperature, low lub oil, oil pressure,overspeed etc) fuel tank and first fill of lub oil and other consumables etc .
210(ii) AlLTERNATOR: Brushless AC alternator, 3 Phase, 415 Volt, 4 wire, rated for output of 25 KVA/ 20 KW, Minimum power factor 0.8, 1500 RPM, IP 23 Protection class enclosure, insulation Class \\"H\\", salient pole, revolving field, single bearing automatic voltage regulator coupled through flexible coupling with and to match the above engine.
211(iiI) BASE PLATE: made out of structural steel as per manufacturers recommended design/specifications.
212(iv) AMF CONTROL PANEL: Factory made cubicle type floor mounted LT Panel board, indoor type made out of MS angle not less than 25X25X5 mm, and 1.6 mm thick MS CRCA sheet, front opening type, protection class IP-54, duly powder coated after seven tank process with electrolytic grade copper bus bar of 1000 Amps capacity for four poles, with all standard switchgear and protection, internal wiring of adequate size PVC insulated multistranded copper conductor cable etc and also consisting of followings:-
213(a) MCCB 415 Volts, 63 Amp, rating 4 Pole 25 KA rupturing capacity, Micro processor based release, draw out type, specially fixed for incoming supply with overload,short circuit and earth fault protection - 2 Nos with suitable rating HRC back up fuses
214(b) Ammeter 0-100 amps, 96 mm X 96 mm square dial flush type ISI marked with selector switch 3 way and current transformers 100/5 A - 01 set
215(c) Voltmeter 0-500 volts 96 mm X 96 mm square dial flush type ISI marked with rotary selector switch 3 way and current transformers 150/5 A - 01 set
216(d) Phase indicating lamps (R-Y-B) -1 set
217(e) Frequency meter digital type 45 to 55 HZ-1 No
218(f) All standard relays, circuits and protection required for automatic operation of Gen set
219(V) ACOUSTIC ENCLOSURE: Sheet metal fabricated cope type silent enclosure manufactured on CNC machines as per CPCB norms and powder coated after seven tank process, the enclosure shall be designed for reducing the sound level to 75 DB (A) at a distance of 1 M at 75 % load under field condition and ox, 70DB at 3 M from Gen set wheh DG set is working at full load alongwith testing confirmance, labelling certification etc as laid down in GSR No 371(E) dt 17 May 2002.
220(VI) Foundation/Plinth/Base shall be provided as per manufacturers recommendations, however minimum 0.5 m Space should be available all around the Set and height of plinth shall not be less than 0.5 M
221(VII) Diesel storage tank of capacity adequate for storage of diesel for 12 hours operation of Gen Set.
222(VIII) MISC: Tool kit, Operation and Maintenance catalogue, spare part list, overhauling manuals, gurantee card etc shall be provided as per manufacturer standard practices.
223Supply, Errection, testing and commissioning complete of manufacturer or OEM manufactured, static silent (Sound Proof enclosure) Diesel Engine Driven Generating Set capable of delivering 256.0 KW (320 KVA), Water cooled, 415 Volts(AC hree phase, 4 Wire system of supply) 50 HZ at power factor 0.8 minimum. The DG Set shall consists of diesel engine coupled to a matching alternator, through flexible coupling and mountd on common base frame and complete with control panel standardised by manufacturer, fuel tank with mounting arrangements and inlet , outlet return inlet oil arrangement, exhaust pipe complete and suitable for conditions prevalent at Meerut (Capacity of Engine, alternators shall be worked out taking all derating factors into consideratuion) including PCC foundation ( of suitable size leaving at least 0.5 M all around for ease of movement and 0.5 M height), antivibration pads,including all features to comply with latest CPCB guidelines and Comprising of followings:-
224(i) ENGINE(Prime Mover): Diesel Engine 1500 RPM , direct injection, four stroke, confirming to ISO3046/BS 5514, water cooled, naturally turbo charged,capabe of giving adequate BHP to drive Alternator capable of delivering 320 KVA(256 KW) at outdoor atmospheric conditions at Meerut (Taking all de-rating factor into consideration),12/24 Volts(as per manufacturer recommendations) electric battery start, complete with fly wheel all standard fittings/fixtures as per manufacturer and including suitable panel with tachometer, lub oil temperature, pressure guage and frequency meters and also including self starter system, dynamo, fuel electric control panel with electronic governor (ECPG) and Engine protection system(Shut down, High water temperature, low lub oil, oil pressure,overspeed etc) fuel tank and first fill of lub oil and other consumables etc .
225(ii) AlLTERNATOR: Brushless AC alternator, 3 Phase, 415 Volt, 4 wire, rated for output of 320 KVA/ 256 KW, Minimum power factor 0.8, 1500 RPM, IP 23 Protection class enclosure, insulation Class \\"H\\", salient pole, revolving field, single bearing automatic voltage regulator coupled through flexible coupling with and to match the above engine.
226(iiI) BASE PLATE: made out of structural steel as per manufacturers recommended design/specifications.
227(iv) AMF CONTROL PANEL: Factory made cubicle type floor mounted LT Panel board, indoor type made out of MS angle not less than 25X25X5 mm, and 1.6 mm thick MS CRCA sheet, front opening type , protection class IP-54, duly powder coated after seven tank process,with electrolytic grade copper bus bar of 1000 Amps capacity for four poles, with all standard switchgear and protection, internal wiring of adequate size PVC insulated multistranded copper conductor cable etc and also consisting of followings:-
228(a) MCCB 415 Volts, 630Amp, rating 4 Pole 70 KA rupturing capacity, Microprocessor based release ,draw out type, specially fixed for incoming supply with overload,short circuit and earth fault protection -2 No with suitable rating HRC back up fuses
229(b) Ammeter 0-100amps, 96mmX96 mm square dial flush type ISI marked with selector switch 3 way and current transformers 100/5 A -01 set
230(c) Voltmeter 0-500 volts 96mmX96 mm square dial flush type ISI marked with rotary selector switch 3 way and current transformers 150/5 A -01 set
231(d) Phase indicating lamps(R-Y-B) -1 set
232(e) Frequency meter digital type 45 to 55 HZ-1 No
233(f) All standard relays, circuits and protection required for automatic operation of Gen set
234(V) ACOUSTIC ENCLOSURE: Sheet metal fabricated cope type silent enclosure manufactured on CNC machines as per CPCB norms and powder coated after seven tank process, the enclosure shall be designed for reducing the sound level to 75 DB (A) at a distance of 1 M at 75 % load under field condition and ox, 70DB at 3 M from Gen set wheh DG set is working at full load alongwith testing confirmance, labelling certification etc as laid down in GSR No 371(E) dt 17 May 2002.
235(VI) Foundation/Plinth/Base shall be provided as per manufacturers recommendations, however minimum 0.5 m Space should be available all around the Set and height of plinth shall not be less than 0.5 M
236(VII) Diesel storage tank of capacity adequate for storage of diesel for 12 hours operation of Gen Set.
237(VIII) MISC: Tool kit, Operation and Maintenance catalogue, spare part list, overhauling manuals, gurantee card etc shall be provided as per manufacturer standard practices.
238SCHEDULE 'A' PART-XV (Water Cooler, Referigerator, Desert Cooler and Geyser)
239Supply and Installation, Comisioning and Testing of Refrigerator with non CFC refrigrent type electric driven single phase of capacity 310 / 325 Ltrs, frost free,double door air cooled sealed unit compressure complete with PVC bottom stand complete all as specified & directed.
240Supply and Installation, Comisioning and Testing of Refrigerator with non CFC refrigrent type frost free double door electric driven single phase of capacity 265 Ltrs, air cooled sealed unit compressure complete with PVC bottom stand complete all as specified & directed.
241Supply and Installation, Comisioning and Testing of Refrigerator with non CFC refrigrent type frost free double door electric driven single phase of capacity 205 Ltrs, air cooled sealed unit compressure complete with PVC bottom stand complete all as specified & directed.
242Supply and Installation Deep freezer with metal top,non CFC refrigerant type, electric driven (single phase) of capacity 300 / 320 Ltrs, frost free complete all as directed.
243Supply and Installation, Comisioning and testing of water cooler non CFC refrigerant type electric driven (single phase) having storage capacity of 80 Ltrs & nominal cooling capacity 40 Ltrs/hr complete including connecting cord, PVC Connection & plug top handling, connecting up with 20mm GI pipe medium grade complete all as specified & directed.
244Supply and Installation, Comisioning and testing water cooler non CFC refrigerant typeelectric driven (single phase) having storage capacity of 150 Ltrs & nominal cooling capacity 60 Ltrs/hr complete including connecting cord,PVC Connection & plug top handling, connecting up with 20mm GI pipe medium grade complete all as specified & directed.
245S&F automatic operation single phase stablizer, naturaly air cooled and desined for input varition of 170 volts to 250 volts and out put voltage stablised at 230 volts wiyh accuracy of +/- 2.5% and capacity 0.50 KVA complete all as specified & directed.
246S&F automatic operation single phase stablizer, naturaly air cooled and desined for input varition of 170 volts to 250 volts and out put voltage stablised at 230 volts wiyh accuracy of +/- 2.5% and capacity 1 KVA complete all as specified & directed.
247S&F automatic operation single phase stablizer, naturaly air cooled and desined for input varition of 170 volts to 250 volts and out put voltage stablised at 230 volts wiyh accuracy of +/- 2.5% and capacity 2 KVA complete all as specified & directed.
248Supplying & Installation commissioning and testing, Desert cooler made out of 1 mm thick MS sheet, electric driven (S.P), 230 volts, AC, air flow capacity 4000 Cum/Hr blade size 406/16 mm, PVC body, 3 speed, 1400 RPM,160 watt, 45 ltrs water tank cap, motorised loures movement, top water inlet complete with pump & motor complete all as specified & directed.
249Total amount of Sch 'A' Part XVI 'A' (Solar Water Heater) (For details see Sch 'A' in PDF folder)
250SCHEDULE 'A' PART XVI-B (Solar Water Heater)
251Supply, installation, commissioning of solar water heating (Flate plate collector) system with heat exchanger suitable for cold resion of capacity 200 ltr complete with solar panels with copper tubes alongwith insulated hot water storage tank double body, system shall be electrical heating back up of 3 KW with necessary safety control ,thermostates ,hot water temp gauge etc complete in all respect including hot water pipes shall be insulated with best quality of insulating material / glass wool duly binded with chicken wire mesh and covered with aluminium sheet duly clamped complete all as specified and directed.
252Supply, installation, commissioning of solar water heating (Flate plate collector) system with heat exchanger suitable for cold resion of capacity 100 ltr complete with solar panels with copper tubes alongwith insulated hot water storage tank double body, system shall be electrical heating back up of 2 KW with necessary safety control ,thermostates ,hot water temp gauge etc complete in all respect including hot water pipes shall be insulated with best quality of insulating material / glass wool duly binded with chicken wire mesh and covered with aluminium sheet duly clamped complete all as specified and directed.
253S & F water storage type electric geyser supplied and installed 25 ltrs capacity complete all as specified and directed.
254Supplying and fixing ball valve high pressure PTMT with epoxy coated alluminium rod etc complete all as specified and directed of following size :-
255SCHEDULE 'A' PART - XVII (Split Air conditioner)
256Supply and Installation and testing Hi wall split units indoor/outdoor comp[lete with cordless remote control unit and with inbuilt air ioniser and plasma filter for better indoor air quality with of capacity 2TR minimum 3 star rating and EER3.2 complete all as directed.
257Supply and Installation and testing Hi wall split units indoor/outdoor comp[lete with cordless remote control unit and with inbuilt air ioniser and plasma filter for better indoor air quality with of capacity 1.5 TR minimum 3 star rating and EER3.2 complete all as directed.
258Supply and Installation and testing Hi wall split units indoor/outdoor comp[lete with cordless remote control unit and with inbuilt air ioniser and plasma filter for better indoor air quality with of capacity 1 TR minimum 3 star rating and EER3.2 etc complete all as directed.
259S & F automatic operation single phase stablizer, naturaly air cooled and desined for input varition of 170 volts to 250 volts and out put voltage stablised at 230 volts wiyh accuracy of +/- 2.5% and capacity 4KVA complete all as directed.
260S & F automatic operation single phase stablizer, naturaly air cooled and desined for input varition of 170 volts to 250 volts and out put voltage stablised at 230 volts wiyh accuracy of +/- 2.5% and capacity 5KVA complete all as directed.
261SCHEDULE 'A' PART - XVIII (Solar Street Light)
262Supply and fixing Solar energy operated street light 14 watts LED including fitting suitable size of cable with accessories ,pole , battery 12V 100 AH, battery box with locking arrangement , solar panel of suitable capacity complete including PCC foundation for pole using PCC 1:3:6 type C-1 using 20 mm stone aggregate complete all as specified and directed
263SCHEDULE 'A' PART-XIX (Fire Fighting)
264Supply & Installation of portable fire extinguishers ABC Powder type 5 Kg capacity, as per IS-2171/13849, 14609, wall mounted type, wall brackets complete in all respect, including fixing on walls complete all as specified and directed.
265Supply and fixing fire beaters with 20 feet long handle with red enamel paint and written \\"Fire\\" on bucket complete all as specified and directed.
266Supply and fixing sheet metal fire Buckets duly painted with red enamel paint and written \\"Fire\\" on bucket complete all as specified and directed.
267Supply and fixing fire Axe with suitable handle duly paintd with red enamel paint all as specified and directed complete all as specified and directed.
268Supply and fixing fire hooks with 20 feet long handle duly paintd with red enamel paint all as specified and directed complete all as specified and directed.
269SCHEDULE 'A' PART XX (Walk in Cold Room)
270Supply, installation, testing and commissioning of Walk - in cold room of two chambers, Freezer Room of size 8' x 8' x 8' consisting of wall and ceiling panel made out of PGI sheet filled with 120 mm PUF insulation, and Ante Room of size 5' x 5' x 8' consisting of wall and ceiling panel made out of PGI sheet filled with 60 mm PUF insulation, for Blood Bank and other low temperature application , anti skid GI flooring on 60 mm PUF, door of suitable dimension, hydraulic door closer, digital temperature indicator, Air cooled low temperature split unit of 2 HP rating with Reciprocating / Scroll Compressors working on R - 22 / R - 410 a refrigerants to maintain temperature of 4+ / - 2 degree Centigrade at an ambient temperature of 30 degree centigrade.etc complete all as specified and directed.
271Supply & fix automatic boost / buck transformer for low and high voltage correction, input voltage 160 to 280 Volts and output Voltage 230 equipped with electronic transistorized relay suitable for correction and cut out 280 Volts on single phase, 50 cycle of 140 Volts to 290 Volts and output voltage stabilized between 215 Volts to 240 Volts capacity 5 KVA and time delay rely 3 minutes complete all as specified and directed.
272Total amount of Sch 'A' Part XXI (Paved Area for Patient vehicle Parking) (For details see Sch 'A' in PDF folder)
273Total amount of Sch 'A' Part XXII (Demolition / Dismantling) (For details see Sch 'A' in PDF folder)
274Note : Tenderers may note that amount of credit Rs 1,00,63,000.00 will be deducted from the total amount arrived, at the time of Acceptance of contract. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56806209
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 24.90 Crore
LAST DATE 15-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Completion Of Incomplete Work Including Reconstruction Of Buildings To Be Demolished For Provision Of Klp Accn For Fd Hospital Ex 9 Inf Div At Meerut (At Risk & Cost Of M/S Builders India)
Basic Detail
Tender No CEB/MRT/T-20 OF 2026-27
Bidding Type Tender
Location
City Meerut
State Uttar Pradesh
Key Dates
Publish Date 25 Sep 2026
Submission Date 15 Oct 2026
Open Date 23 Oct 2026
Finance
Tender Value 24.90 Crore
Tender Fee 3000
EMD 15 Lakhs
Exemption Available
Document List
Tendernotice_1.pdf
828c2d74-4c22-43c8-b5ac-101f86dd2ddd.html
BOQ_876574.xls
drawings1.pdf
tender.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 25, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 07, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 3 days
Sep 25, 2026
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Completed
Oct 15, 2026
18:00 IST

Corrigendum-3 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 11 days
Sep 18, 2026
18:00 IST

Corrigendum-4 Issued

Clarifications on tender conditions and amendments issued.

Completed
Sep 25, 2026
18:00 IST

Corrigendum-5 Issued

Clarifications on tender conditions and amendments issued.

Completed
Oct 15, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 11 days
Oct 23, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 19 days

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1.pdf

html

828c2d74-4c22-43c8-b5ac-101f86dd2ddd.html

xls

BOQ_876574.xls

pdf

drawings1.pdf

pdf

tender.pdf

Disclaimer