Tender For 8563/E8 : special Repair To Ors Map Accn For Lt Cable Panel & Street Lights And Gi Pipe Line With Fittings Of Madhuban Complex At Shahjahanpur Cantt Under Ge (East) Bareilly
Tender Value
49.40 Lakhs
Estimated cost
Bid Submission
24 Aug 2026
0 days left
EMD
98812
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Bareilly → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for 8563/E8 : special Repair To Ors Map Accn For Lt Cable Panel & Street Lights And Gi Pipe Line With Fittings Of Madhuban Complex At Shahjahanpur Cantt Under Ge (East) Bareilly
BOQ
| Sl. No. | Item Description |
| 1 | M & L for Excavation in trenches n. exc 1.5 mtr wide and not exc 1.5 mtr in depth for laying pipe line and getting soft/loose soil complete all as specified and directed. |
| 2 | M & L for Returning , filling in including spreading, levelling, watering and well ramming in laying not exceeding 25 cm thick in soft/loose soil complete all as specified and directed. |
| 3 | M & L for Removing excavated material (soils) to a distance not exceeding 50 m and depositing whare directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 4 | Taking up or down any type DI / MS pipe 100 mm to 150 mm dia and connections complete all as specified and directed. |
| 5 | M & L for Boring under Road / PCC by using manual tool for inserting, of Pipe line any size complete all as specified and as directed by the Engineer-In-Charge. |
| 6 | Taking up or down any type GI pipe 25 mm to 50 mm dia and connections complete all as specified and directed. |
| 7 | Supply , Laying, jointing and leakage testing GI Pipe medium grade including supply and fixing of all fittings such as bend, tee, elbow, union, reducer etc, laid in trenches as specified and as directed at site of the following sizes :- . |
| 8 | (a) 25 mm dia |
| 9 | (b) 40 mm dia |
| 10 | (c) 50 mm dia |
| 11 | Supply, laying,connecting and testing 150 mm bore, ductile iron pipes tyton joint class K- 9 suitable for including rubber joint in standard working length conforming to IS 8329 laid in trenches complete all as specified and directed. |
| 12 | Supply, laying,connecting and testing 100 mm bore, ductile iron pipes tyton joint class K- 9 suitable for including rubber joint in standard working length conforming to IS 8329 laid in trenches complete all as specified and directed. |
| 13 | M&L for Ductile special fitting such as bends,tapers.tee pieces(single and double branch) any type and angle/radius and straight connecting pieces but all end flanged complete all as specified and directed . |
| 14 | Material and labour for construction of block masonry valve pit / chambers of size 1.0m x 1.0m x 1m including necessary excavation in any type of soil. dismantling the existing fly ash brick masonry, 15 mm thick plaster in CM 1:4 on both side of valve with and including MS fabricated cover with angle iron frame of size 32mm x 32mm x 4mm and CRCA sheet 2mm thick with locking arrangement and applying two coats of synthetic enamel paint over a coat of red oxide primer on both side of the cover complete all as specified and directed . |
| 15 | S & F sluice valve, class PN-1.6, heavy duty, both ends flanged with steel spindle & check nut, CI operating wheel and all nuts, bolts, washers, gaskets etc; including dismantling of old unserviceable sluice valve complete of the following sizes 100mm dia as specified and directed |
| 16 | S & F sluice valve, class PN-1.6, heavy duty, both ends flanged with steel spindle & check nut, CI operating wheel and all nuts, bolts, washers, gaskets etc; including dismantling of old unserviceable sluice valve complete of the following sizes 80mm dia as specified and directed |
| 17 | S&F gun metal iron gate valve with iron wheel head, screwed both ends for iron pipe, ISI marked, complete all as specified of the following sizes including dismantling the old unserviceable existing valve complete :- |
| 18 | (a) 25mm dia |
| 19 | (b) 40mm dia |
| 20 | (c) 50mm dia |
| 21 | Material and labour for river fine sand, washed and screened dry for caushioning to under ground cable in trenches below and around under ground cable including spreading and levelling punning complete. |
| 22 | M&L for laying bricks, sub class 'B' for protection of cable, in trenches, laid in dry flat across the cable with length of whole bricks complete all as specified and directed. |
| 23 | Taking down/out old defective rusted iron pole from LT line connection of any size testing and checking of cable of any material complete all as specified & directed. |
| 24 | S& Fix steel tubular swaged poles completewith cast iron base plate, finial taperplug, bolts, nuts & screws asspecified type 410 SP-31 swanneck as per existing pole (9 metres) complete all as specified. |
| 25 | Taking down/out old defective cable from trench/floor/road/wall/pipe /pole service connection of any size testing and checking of cable of any material complete all as specified & directed. |
| 26 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 Sqmm 3.5 core complete all as specified and directed. |
| 27 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 Sqmm 3.5 core complete all as specified and directed. |
| 28 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 3.5 core complete all as specified and directed. |
| 29 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sqmm 4 core complete all as specified and directed. |
| 30 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6 Sqmm 2 core complete all as specified and directed. |
| 31 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 Sqmm 3.5 core complete all as specified and directed. |
| 32 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 Sqmm 4 core complete all as specified and directed. |
| 33 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 Sqmm 2 core complete all as specified and directed. |
| 34 | Supply and fix FRP type junction / looping box of size 280 x 170 x 130 mm top hinged with aluminium busbar of 50 Amp rating for phase and neutral on porcelain based insulator, fixed on pole with the help of MS nuts, bolts and MS clamps - 2 nos of size 40 x 4 mm thick with one No MCB SP 6 Amp capacity mounted on din rail inside box, work also includes making suitable hole in pole to take out connections to fitting if required at site complete all as specified and directed. |
| 35 | S & F steel tubing GI Light grade 32 mm bore for fixing of tapping of incoming and outgoing point complete all as specified and directed. |
| 36 | S & F steel tubing GI Light grade 40mm bore for fixing of tapping of incoming and outgoing point complete all as specified and directed. |
| 37 | S & F in replacement of GI tubing light grade 80mm nominal bore for cable protection fixed with clamps of M.S. Flat iron 25x3mm, GI nuts, bolts and washers to poles/under floor/under roads/alongwith walls including two coats of aluminium paint over a coat of red oxide primer on clamps complete including taking up of old UNSV GI tubing complete all as specified and directed by Engr-in-Charge. |
| 38 | M & L for Boring under Road / PCC by using manual tool for inserting, including GI pipe of 80mm size for protection of cable complete all as specified and as directed by the Engineer-In-Charge. |
| 39 | M & L for Cutting of existing RCC Floor/PCC/Tiles for electrical cable and supply and fix tube, 'light grade, galvanised 25mm dia, necessary connection to TPN DB from LT control panel and making good to the disturbed surfaces of floor from RCC including to match the existing type etc all as directed |
| 40 | M & L cupper wire with Two core 2.5 sqmm PVC insulated 1100 volts grade connected from Security light to DB/main board with PVC conduit complete all as specified and as directed. |
| 41 | M&L Plain cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate for coping around poles, including necessary form work finishing even and smooth complite all as specified and directed . |
| 42 | M&L for cement concrete type D2 1:4:8 (40mm graded aggregate) in pole/stay/ plinth etc in foundation filling completed all as directed by Engr-in-Charge. |
| 43 | Supply and fix testing and commissioning Out door type Bus bar made out of MS CRCA sheet 2mm thick of size 0.60 Mtrx0.60mtrx0.30 mtr consisting of cupper Bus Bar of rating 200 Amps working 4 wire system 415 volt mounted on various insulator with cable earth alleys including steel flexible pipe as per required length at site with new aluminium lugs of suitable size including making connection properly of existing cables of any size/type for existing new incoming and outgoing cables complete all as specified and as directed by Engr-In-Charge. Note : Bus Bar mounting stand made out of angle iron of size 50mm x50mm x 6mm, 600 mm high and size suitable to mount the panel including foundation of PCC (1:3:6) type C-1 using 20mm graded stone aggregate with and including excavation and earth work in any type of soil complete.Contractor should arrange factory visit to Engr-in-charge at own arrangement for LT Pannel manufacturing. |
| 44 | (a) INCOMING :- (i) Supply and fix 4 Pole MCCB ,100 Amp 50 Hz 415 V, With Thermal based Release type Capacity 25 KA complete all as specified and directed =04 Nos |
| 45 | M&Lfor earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick, buried directly in ground, vertically to a depth not less than 2.25 mtr deep below ground level with top edge of the earth plate at depth not less than 1.5 mtr below ground level earth plate surrounded by 15 cm thick and packed layers of charcoal, dust and common salt, earth lead GI strip 32x6mm dia by means of bolts, nuts, check-nuts and washers of galvanized iron and thimbles and of earth wire protected by galvanized iron pipe light grade 15mm bore and water pipe 20 mm bore GI medium grade with funnel and wire mesh complete including excavation and earth work, PCC chamber and cover in cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregate in lieu of CI cover and frame etc all as specified and shown in electrical plate No. 3 of SSR-2009 (Part-I). |
| 46 | Material & Labour for supply,installing,testing & commissioning of factory made LT panel 4x iron leg mounted made out of CRCA sheet of 3.15 mm(CPRI Approved) thick indoor type totally enclosed weather ,dust and vermin proof with front opening hinged door and locking arrangement mounted on MS flat iron with clamp welded to suitable size of angle iron frame around panel body duly grouted on ground, 415 Volt, 3 Phase, 4 wire AC 50 Hz having 3 phase with neutral aluminium Bas Bar 200 A suitable for connection of 4x3 block meter,and 1x block for bus bar and MCCB (incomming & outgoing) insulated with space for fixing three/single phase smart prepaid meter of suitable capacity 12 Nos meter with transparent toughen Glass not less than 4mm thick for each meter , Copper lugs, spacers, Mounting Channel, rubber gasket, locking knobs, Hylam sheets pieces, PVC shrinkable connections, suitable compartments for each prepaid meters and front and rear shutters with suitable locking arrangement epoxy powder spray painted with one coat primercomplete including PCC 1:2:4 type B-1 using 20 mm graded stone agregate foundation raised base angle iron size 50mm x50mmx6mm thick 60cm up and 60cm ground level complete all as specified and directed by the Engr in Charge of the following components:- Contractor should arrange factory visit to Engr-in-charge at own arrangement for LT Pannel manufacturing. including taking down old type meter box:-(i) Incoming MCCB100 Amps 25 KA, 415 V, 4 pole--01 No.(Takingout & deposit MES store yard)(ii) R-Y-B phase LED indicating lamp-03 Nos(iii)MCB double pole 63 Amps-12 nos(outging for meter)(iv) 200 Amps TPN main aluminium bus bar(v) Space for mounting three/single phase smart prepaid meter -12 Nos(vi) All connection with wiring with 10/6 sqmm PVC insulated 2 core multistranded copper conductor drawing through PVC flexible conduit and connected with appropriate size copper thimbles. |
| 47 | Material & Labour for supply,installing,testing & commissioning of factory made LT panel outdoor type for LT distribution switch gear and control gear,floor mounted ,cubical type modular compartment, dust and vermin proof with neoprene gasket fabricated out of CRCA sheet of thick ness not less than 3.15 mm (CPRI Approved) complete with cupper bus bar chamber & aluminium Bus bar of four wire system 415 volt with heat shrinkable insulator sleeve suitable for 630 A for phases and for neutral having openable front and rear shutters with suitable locking arrangement epoxy powder spray painted with one coat primercomplete including PCC 1:2:4 type B-1 using 20 mm graded stone agregate foundation raised base angle iron size 50mm x50mmx6mm thick 60cm up and 60cm ground level complete all as specified and directed by the Engr in Charge of the following components:- Contractor should arrange factory visit to Engr-in-charge at own arrangement for LT Pannel manufacturing. |
| 48 | (b) INCOMING :- (i) Supply and fix 4 Pole MCCB ,630 Amp 50 Hz 415 V, With 250 Amp change over with handle Thermal based Release type Capacity 35 KA complete all as specified and directed =01 Nos |
| 49 | (c) OUTGOING :- (i) Supply and fix 4 Pole MCCB ,200 Amp 50 Hz 415 V, With Thermal based Release type Capacity 25 KA complete all as specified and directed =05 Nos(d)Supply and fix R Y B Phase LED based indicator lamp sets comprising of three colours complete all as specified and directed =01set(e)Ammeter 0 - 400 Amps, Digital display, flush mounted 3 phase 4 wire with slector switch including CTs of required capacity =01 Set(f)Voltmeter 0 - 600 Volts, Digital display, flush mounted 3 phase 4 wire with slector switch - 01 set.(g)Supply and fix time switches 415 V three Phase of 20 Amp rating with contactor fitted inside steel enclosure. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 03, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 24, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
TodayAug 31, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender