Tender For Certain Provision Works In The Aor Of Age B/R-Ii Under Ge Kapurthala= 2 Excavating In Trenchs Not Exceeding 1.5 Metre Wide And Not Exceeding 1.5 Metre In Depth; For Foundation, Etc. And Not Exc 10 Sqm On Plan In Any Type Of Soil And Getting Out Complete All As Specified And Directed. 3 M&L For Plain Cement Concrete (1:3:6) Type C-2 Using 40Mm Graded Stone Aggregate As In Foundation Filling And Mass Concrete Complete All As Specified And Directed. 4 M&L For Plain Cement Concrete (1:2:4) Type B-2 Using 40Mm Graded Stone Aggregate As In Foundation Filling And Mass Concrete Complete All As Specified And Directed. 5 M&L For Reinforced Concrete 300 Mm Dia Pipe Class Np-3 Laid And Jointed Complete With Collars, Complete All As Specified And Directed. 6 M&L For Rendering 15Mm Thick On Fair Faces Brick Surfaces In Cement Mortar 1:4 Finished Even And Smooth Without Using Extra Cement Complete All As Specified And Directed. 7 M&L For Three Coats Of White Washing On Walls Including Reparing Of New ( Plastered Or Unplastered ) Surfaces Complete All As Specified And Directed. 8 M&L For Plain Cement Concrete (1:3:6) Type C-2 Using 40Mm Graded Stone Aggregate As In Bed Of Surface Channels And Drains Complete All As Specified. 9 M&L For Brick Work With Sub Class B Burnt Clay Bricks (Old Size Bricks) Straight Or Curved On Plan To Any Radius In Half Brick Thick Walls Built In Cement Mortar 1:4 Complete All As Specified And Directed. 10 M&L For Brick Work With Sub Class B Burnt Clay Bricks (Old Size Bricks) Straight Or Curved On Plan Exceeding 6M Mean Radius, Built In Cement Mortar 1:4 Complete All As Specified And Directed. 11 M&L For Flush Pointing To Brick Walls With Cement Mortar 1:3 Complete All As Specified And Directed. 12 M&L For Roviding Cement Concrete (1:2:4) Type B-1 Using 20Mm Graded Stone Aggregate As In Copings, Kneelers, Apex Stones, Bed Plates Etc Including Necessary Form Work Complete All As Specified And Directed. 13 Extra For Forming Fair Finish To Drain Or Channel Of Cement Concrete, 30Cm Inner Girth, Using Extra Cement Including Forms Moulds/Mitered Stopped Ends Etccomplete All As Specified And Directed. 14 M&L For Pre-Cast Reinforced Cement Concrete (1:2:4) Type B-1 Using 20Mm Graded Stone Aggregate As In Manhole Covers , Drain Covers And Set In Cement Mortar (1:4) Including Form Work Complete All As Specified And Directed. (Reinforcement Measured Separately). 15 M&L For Framed Mild Steel Work Of Grade E-165 (Fe-290) As In Framed Work Such As Doors, Gates Or Flat Iron Frame Work For Drain Covers Etc,Complete All As Specified And Directed. 16 Excavating Over Areas In Soft/Loose Soil Not Exc 1.5 M Deep And Getting Out Complete All As Specified And Directed. 17 Excavating Over Areas In Soft/Loose Soil Exc 1.5M Deep And N.Exc 3.0 M Deep And Getting Out Complete All As Specified And Directed. 18 Use & Waste Fair Finished Flat Surfaces Formwork To Faces Of Walls, Retaining Walls, Abutments, Parapets And Staircase Railing And Similar Work Including Attached Pillasters, Buttresses, Etc; Vertical Or To Better Complete All As Specified And Directed. 19 M&L For Reinforced Cement Concrete Design Mix M-25 (20Mm Graded Aggregates) In Walls, Retaining Walls, Basement Walls And The Like; Any Thickness; Above Top Of Footings; Including Attached Pilasters And Buttresses Complete All As Specified And Directed. 20 M&L For Tmt Bars 10Mm Dia And Over, Cut To Length, Bent To Shape Required Including Cracking Bending, Hooking Ends And Binding With And Including Mild Steel Wire (Annealed) Not Less Than 0.90Mm Dia Complete All As Specified And Directed. 21 M&L For Tmt Steel Bars 6Mm To 8Mm Dia, Cut To Length, Bent To Shape Required, Including Cranking, Bending Spirally For Hooping For Columns, Hooking Ends And Binding With The Including Mild Steel Wire (Annealed) Not Less Than 0.9Mm Dia Or Securing With Clips Complete All As Specified And Directed. 22 M&L For Tmt Steel Bars 5 Mm Dia And Over Upto And Including 10Mm Dia As In Stirrups, Spacers And Binders, Cut To Length , Bent To Shape Required Inluding Cranking Bending Hooking Ends And Binding With And Including Mild Steel Wire (Annealed ) Not Less Than 0.9Mm Dia Or Securing With Clips Complete All As Specified. 23 M&L For Rolled Sections As In Main And Cross Beams, Hip And Jack Rafters; Purlins Where Connected To Common Rafters And Running Rails And Guides For Sliding Doors; Fixed With Angle Cleats Or Other Connecting Plates Of Fe-290 Grade E-250 Complete All As Specified And Directed. 24 S&F Of Gi Steel Expended Metal Of Size 25*25Mm Cut To Length, Bent To Shape Required And Tying With And Including Annealed Mild Steel Wire Galvanized, Steel Staples And Fixed To Wood Or Steel Members, Weight Not Exceeding 4 Kg Per Square Metre Complete All As Specified And Directed. 25 M&L For Boring 300Mm Dia Holes 10M Deep In Any Type Of Soil For Under-Reamed Piles And Getting Out And Disposal Of Spoil To A Distance Of N.Exc 50 M Complete All As Specified And Directed. 26 S&F Of Upvc Pipes (Sch-40) (Slotted) 150Mm Bore Dia Incl All Necessary Fitting Complete All As Specified And Directed. 27 S&F Of Upvc Pipes (Sch-40) (Blind)150Mm Bore Dia Incl Plug Cap And All Necessary Fitting Complete All As Specified And Directed.. 28 M&L For Filling 12.5Mm Graded Coarse Aggregates In Harvesting Pit Upto Height 0.50M Complete All As Specified And Directed.. 29 M&L For Filling 3Mm To 5Mm Pea Gravel In Harvesting Pit Complete All As Specified And Directed. 30 M&L For Filling Coarse Sand In Harvesting Pit Upto Height 0.50M Complete All As Specified And Directed. 31 Returning, Filling In (Soil) Including Spreading, Levelling, Watering And Well Ramming In Layers Not Exceeding 25 Cm Thick In Any Type Of Soil Complete All As Specified And Directed. 32 Removal Of Excavated Material (Soil) To A Distance Not Exceeding 50 Metre And Depositing Where Directed At A Level Not Exceeding 1.5M Above The Starting Point Complete All As Specified And Directed. 33 Surface Excavation N.Exc 30Cm Deep And Averaging 15Cm Deep And Getting Out In Soft/Loose Soil Aconcrete All As Directed. 34 M&L For Cement Concrete 1:4:8 Type D-2 Using 40Mm Graded Stone Aggregate As In Foundation, Filling And Mass Concrete All As Specified And Directed. 35 Form Work To Sides Of Concrete Fdn Footing Base Of Columns And Raft Beams Sides And Soffits (If Any) Of Fdn And Plinth Beams And Similar Wk Vertical Or To Batter For Rough Finished Surfaces. 36 Form Work To Sides Of Pillars, Posts, Struts, Pier, Columns Square, Rectangular Or Polygonal Rough Finished Surface Of Concrete. 37 Form Work To Sides And Soffits Of Floor Or Roof Beams, Beam Haunching, Lintel Etc Rough Finished Surfaces Of Concrete Flats. 38 Formwork To Soffits Of Suspended Slabs Such As Roof Slabs, Floor Slabs, Landings And Similar Work; Exceeding 200Mm Thick (Horizontal Or Sloping) All As Specified And Directed. 39 M&L For Rcc M-25 Design Mix As In Foundation, Including Raft, Fooling Fdn Beams, Plinth Beams Bases For Columns And Mass Concrete Complete All As Specified And Directed. 40 M&L For Rcc M-25 Design Mix As In Plinth Beams, Roof Beam, Cantilivers, Bressummers, Lintel Over 1.5M Span Complete All As Specified And Directed. 41 M&L For Rcc M-25 Design Mix As In Columns , Pillars, Piers, Posts And Struts Etc. Complete All As Specified And Directed. 42 M&L For Rcc M-25 As In Slabs Supported On Walls, Beams And Columns In Floors, Roofs, Landings, Balconies, Canopies, Deck Slabs, Chhajja And In Shelves And The Like Complete All As Specified And Directed. 43 M&L For Old Size Brick Work With Subclass ‘B’ Bricks, Straight Or Curved On Plan Exc 6M Mean Radius Built In Cement Mortar 1:6 Complete All As Specified And Directed. 44 M&L For Rendering 15Mm Thick On Fair Faces Brick Surfaces In Cement Mortar 1 : 4 Finished Even And Smooth Without Using Extra Cement Including Wpc @ 3% Of Wt Of Cement Complete All As Specified And Directed. 45 - Ditto - All As Per Item No 43 Here-In-Before But In Cement Mortar 1:6 Complete Complete All As Specified And Directed. 46 M&L For Rendering 10Mm Thick On Fair Faces Of Concrete Surfaces Surfaces In Cement Mortar 1 : 3 As In Ceiling Finished Even And Smooth Without Using Extra Cement Complete All As Specified And Directed. 47 M&L For Preparation Of New Plastered Surfaces Of Walls And Applying 2Mm Thick Of Birla White Putty To Obtain The True Line To Achieve Smooth Surface And Applying Two Coats Of Oil Bound Distermper Complete All As Specified And Directed. 48 M&L For Applying Two Coats Of Exterior Emulsion (Apex) Paint On Newly Plastered Or Unplastered Wall Surface Over A Coat Of Cement Primer Including Preparation Of Surfaces, Complete All As Specified And Directed. 49 M&L For Preparation Of New Plastered Surfaces Of Ceiling And Applying Three Coats Of White Wash On Ceiling Complete All As Specified And Directed. 50 M&L For Hardcore Of Gauge N.Exc. 63 Mm, Deposited, Spread And Levelled In Layers N.Exc 15 Cm Thick, Watered And Rammed To A True Surface Under Floor And Plingh Protection All As Specified And Directed. 51 M&L For 100Mm Thick Cement Concrete Type B- 2, 1:2:4 (40Mm Graded Aggregate) As In Floor Over Hard Core Complete All As Specified And Directed. 52 M&L For 25Mm Thick Plain Cement Concrete Type B-1, 1:2:4 (12.5Mm Graded Aggregate) As On Roof Paddings Complete All As Specified And Directed. 53 M&L For 75Mm Thick Pcc 1:3:6 Type C2 As In Plinth Protection/Hard Standing Finishing The Surface Even And Smooth With Out Using Extra Cement Complete All As Specified And Directed. 54 M&L For Anti-Termite Treating The Bottom And Sides Of Excavation At The Rate Of 5 Litres Of Emulsion Per Square Metre Of Surface Area Complete All As Specified And Directed. 55 M&L For Anti-Termite Treating The Top Surface Of Filled Earth At The Rate Of 5 Litres Of Emulsion Per Square Metre Of Surface 56 M&L For Anti-Termite Treating The Soil Under Plinth Protection At The Rate Of 5 Litres Of Emulsion Per Square Metre Of Surface Area 57 M&L For 40Mm Thick In Cement Concrete Mortar 1:2:4 Type B-0, Damp Proof Course To Horizontal Or Vertical Surfaces Including Necessary Formwork Complete All As Specified And Directed. 58 M& L For Applying Evenly A Coat Of Blown Type Bitumen At The Rate Of 1.50 Kg Per Square Metre And Blinding With Clean Dry Sand @ 0.05 Cum Per Sqm Complete All As Specified And Directed. 59 M&L For Polythene Film, 50 Micron Thick, Laid On A Coat Of Bitumen Primer, @ 0.30 To 0.50 Kg Per Sqm Complete All As Specified And Directed. 60 S&F Of Factory Made Upvc White Colour Two Track Two Panels Sliding Glazed Window Upto 1.50M Height Made Of (Small Series) Frame 52 X 44 Mm & Sash 32 X 60 Mm Both Having Wall Thickness Of 1.9 ± 0.2 Mm And Single Glazing Bead Of Appropriate Dimension. (Area Of Window Upto 1.75 Sqm) Comprising Of Upvc Multi-Chambered Frame, With Inbuilt Roller Track And Sash Extruded Profiles Duly Reinforced With 1.60 ± 0.2 Mm Thick Galvanized Mild Steel Section Made From Roll Forming Process Of Required Length (Shape & Size According To Upvc Profile), Appropriate Dimension Of Upvc Extruded Glazing Beads And Upvc Extruded Interlocks, Epdm Gasket, Wool Pile, Zinc Alloy (White Powder Coated) Touch Locks With Hook, Zinc Alloy Body With Single Nylon Rollers (Weight Bearing Capacity To Be 40 Kg), G.I Fasteners 100 X 8 Mm Size For Fixing Frame To Finished Wall And Necessary Stainless Steel Screws Etc. Profile Of Frame & Sash Shall Be Mitred Cut And Fusion Welded At All Corners, Including Drilling Of Holes For Fixing HardwareS And Drainage Of Water Etc. After Fixing Frame The Gap Between Frame And Adjacent Finished Wall Shall Be Filled With Weather Proof Silicon Sealent Over Backer Rod Of Required Size And Of Approved Quality, Complete All As Specified And Directed. (Glass Or Wiremesh Shall Be Paid Separately) Note: For Upvc Frame And Sash Extruded Profiles Minus 5% Tolerance In Dimension I.E. In Depth & Width Of Profile Shall Be Acceptable. Variation In Profile Dimension In Higher Side Shall Be Accepted But No Extra Payment On This Account Shall Be Made. 61 S&F Of 5.50Mm Thick Plain Sheet Glass, One Side Sheet Glass Is Groundor Obscured Or Frosted In Squares Exc 0.5 Sqm Each Pane And Glazing With Metal Beads Complete All As Specified And Directed. 62 M&L For Light Shade Vitrified Ceramic Tiles Light Shade 10 Mm Thick (Square/ Rectangular) Polished, Area Of Each Tiles Exceeding 0.42 Sqm But Not Exceeding 1.00 Sqm, In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Over 15Mm Thick Screed Complete All As Specified And Directed. 63 - Ditto - All As Per Item No 62 But In Vertical Surfaces Over 10Mm Plastercomplete All As Specified And Directed. 64 S&F Of Anodised Aluminium Grill (Anodised Transparent Or Dyed To Required Shade According To Is: 1868 With Minimum Anodic Coating Of Grade Ac 15) Of Approved Design/Pattern, With Approved Standard Section And Fixed To The Existing Window Frame With C.P. Brass/ Stainless Steel Screws @ 200 Mm Centre To Centre, Including Cutting The Grill To Proper Opening Size For Fixing And Operation Of Handles And Fixing Approved Anodised Aluminium Standard Section Around The Opening, All Complete As Per Requirement And Direction Of Engineer In-Charge. 65 Supply And Fixing Factory Made Upvc Door Frame Made Of Upvc. Extruded Sections Having An Overall Dimension (Extruded Section Profile) 48X40 Mm (Tolerance ± 1 Mm), With Wall Thickness 2.0 Mm (± 0.2 Mm), Corners Of The Door Frame Jointed With Galvanized Brackets And Stainless Steel Screws, Joints Mitred And Plastic Welded. The Hinge Side Vertical Of The Frames Reinforced By Galvanized M.S. Tube Of Size 19 X 19 Mm And 1Mm (± 0.1 Mm) Wall Thickness And 3 Nos. Stainless Steel Hinges Fixed To The Frame Complete All As Specified By The Manufacturer And As Per Directions Of Engineer-In-Charge 66 Supply And Fixing Factory Made Upvc White Colour Casement Door With 3D Hinges Made Of (Big Series) Frame 67 X 64 Mm & Sash 67 X 110 Mm Both Having Wall Thickness Of 2.3 ± 0.2 Mm And Single Glazing Bead / Double Glazing Bead Of Appropriate Dimension. (Area Of Door Upto 2.00 Sqm) Comprising Of Upvc Multi-Chambered Frame, Sash And Mullion (Where Ever Required) Extruded Profiles Duly Reinforced With 1.60 ± 0.2 Mm Thick Galvanized Mild Steel Section Made From Roll Forming Process Of Required Length (Shape & Size According To Upvc Profile), Upvc Extruded Glazing Beads Of Appropriate Dimension, Epdm Gasket, Zinc Alloy (White Powder Coated) 3D Hinges And One Handle On Each Side Of Panels Along With Zinc Plated Mild Steel Multi Point Locking Having Transmission Gear, Cylinder With Keeps And One Side Key, G.I. Fasteners 100 X 8 Mm Size For Fixing Frame To Finished Wall And Necessary Stainless Steel Screws Etc. Profile Of Frame & Sash Shall Be Mitred Cut And Fusion Welded At All Corners, Mullion (If Required) Shall Be Also Fusion Welded Including Drilling Of Holes For Fixing HardwareS And Drainage Of Water Etc. After Fixing Frame The Gap Between Frame And Adjacent Finished Wall Shall Be Filled With Weather Proof Silicon Sealent Over Backer Rod Of Required Size And Of Approved Quality Complete All As Specified And Directed. (Glass Shall Be Paid Separately) Note: For Upvc Frame, Sash And Mullion Extruded Profiles Minus 5% Tolerance In Dimension I.E. In Depth & Width Of Profile Shall Be Acceptable. Variation In Profile Dimension In Higher Side Shall Be Accepted But No Extra Payment On This Account Shall Be Made. 67 S&F Of Aluminium (Die Cast Body) Door Closer Hydraulically Regulated Designation No. 3, Universal Type, Suitable For Door Shutters Of 851 To 1000 Mm In Width And Of Weight Between 61 To 80 Kg And Fixed Complete All As Specified And Directed. 68 M&L For Preparation Of Newly Plastered Surface Making Surface Completely Dry And Applying A Coat Of Bitumen Primer @ 0.40 Ltr/Sqm And After Drying Of Primer Apply App Modified Water Proofing Membrane With Non Woven Polyster Reinforcement 3Mm Thick Superior Multipolymeric Weighing Not Less Than 3Kg/Sqm With Properties Of High Penetration And Centre Core Consisting Of 90 Micron High Molecular High Density Polyethylene (Mhhdpe) Film Consisting Of Five Layers With A Coat Of Hot Blown Bitumen 85/25 @ 1.20 Kg/Sqm Under And Over The App Membrane Laid With Torching Application To The Surface Complete And Sealing The Side As Well As End Laps (Overlaps Should Not Be Less Than 10 Cm) And Applying Two Coats Of Aluminium Paint Above App Membrane Surface , Complete All As Specified And Directed. 69 S&F Of Heat Resistant Terrace Tiles (300 Mm X 300 Mm X 20 Mm) With Sri (Solar Refractive Index) > 78, Solar Reflection > 0.70 And Initial Emittance > 0.75 On Waterproof And Sloped Surface Of Terrace, Laid On 20 Mm Thick Cement Sand Mortar In The Ratio Of 1:4 (1 Cement : 4 Coarse Sand) And Grouting The Joints With Mix Of White Cement & Marble Powder In Ratio Of 1:1, Including Rubbing And Polishing Of The Surface Upto 3 Cuts Complete, Including Providing Skirting Upto 150 Mm Height Along The Parapet Walls In The Same Manner. 70 Excavation In Post Holes (Or Similar Holes) Each N Exc 0.5 Cum, Getting Out , Returning Filling In Layers Not Exceeding 25Cm Including Watering And Ramming And Removing Surplus Earth To A Distance Not Exceeding 50 Metre Complete All As Specified And Directed. 71 M&L For Plain Cement Concrete (1:5:10) Type D-2 Using 40Mm Graded Stone Aggregate As In Foundation Filling And Mass Concrete And As In Sub Base Of Floors Complete All As Specified. 72 S&F Of Steel Work In Tubular Trusses, Rafters And Posts Etc Including Special Shaped Washer Etc. Complete Using Erw Or Induction Butt Welded Tubes Conforming To Is-1161-1979 (Grade St-240 ) Complete All As Specified And Directed. 73 S&F For Plates (Plain Or Chequered) Channels, Square Cut Or Notched (Ordinary And Counter Sunk) Forming Holes, Without Any Attachment Conforming To Fe-410-W (Gde-E-250) Quality B Complete All As Specified And Directed. 74 M&L For Pre Painted Galvalume Aluminium Zinc Coating Gi Based Corrugated Steel Sheet 0.50 Mm Thick Of An Colour Having Tensile Strength Of 550 Mpa As In Roof Covering/ Cladding To Wall, Fixed With Self Tapping Screws Complete All As Specified And Directed. 75 S&F Of Pre-Painted Galvalume Aluminium Zinc Coating Gi Based Plain Steel Sheet 0.50Mm Of An Colour Having Tensile Strength Of 550Mpa As In Roof Covering/Cladding To Wall, Fixed With Self Tapping Screws Complete All As Specified And Directed. 76 M&L For Two Coats Of Cement Base Paint, White Or Tinted On Walls / Vertical Surfaces Incl Preparing Of New ( Plastered Or Unplastered ) Surfaces With Chalk Whiting Priming Complete All As Specified And Directed. 77 M&L For Preparation Of New Or Previously Untreated Steel Surfaces Of Any Description , Over 10 Cm Width Or Girth Not Otherwise Described For And Priming With Red Oxide And Applying Two Coat Of Synthetic Enamel Paint Over Priming Coat All As Specified End As Directed. 78 M&L For Machine Pressed Precast Concrete Interlocking Paver Block Any Shape And Size Confirming To Is-15658 - 2006 Of 60Mm Thick Ness, M-35 Grade With Grey Cement And Pigment Over Sand Cushioning Complete All As Specified And Directed. 79 M&L For 25Mm Fine Sand Filling Under Floor Or In Foundations In Layers Including Watering And Consolidation Complete All As Specified And Directed. 80 M&L For 25 Mm Thick Cement Concrete 1:2:4 Type B-1 Using 20 Mm Graded Crushed Stone Aggregates Finished Even & Smooth Without Using Extra Cement Complete All As Specified And Directed. 81 M&L For Non Skid Ceramic Coloured Tiles 7 To 8 Mm Thick (Square/Rectangular) Area Of Each Tile Exceeding 0.11Sqm But N.Exc 0.18 Sqm In Floor Set And Jointed In Neat Cement Slurry And Pointed In White Or Colour Cement To Match The Tiles, With 15 Mm Thick Cement Screed Bed In Cm (1:6) Complete All As Specified And Directed. 82 M&L For Rolled Sections Fe 410-W(Gde-E-250) Quality -A As In Framing For Cladding, Glazing And The Like Fixed With Angle Cleats And Connecting Plates, Etc. Complete All As Specified And Directed. 83 M&L For Roof Trusses (Framed), Trussed, Purlins, Crane Gantries, Rails And Fastenings And Heavy Bracket Framing (Beam, Tee, Angle, Channel Or Flat Sections) Including Distance Pieces, Cleats Etc.Fe-410(Gde-E250) Complete All As Specified And Directed. 84 S&F Of Mild Steel Screw Bolts 16Mm Dia (Machine Made) With Hexagonal Or Square Heads At One End And Screwed The Other, Or Screwed Both Ends, Each Screwed End To Be Fitted With Washers And One Hexagonal Or Square Nut, Exc 22.5Cm And N.Exc 30Cm Long Complete All As Specified And Directed. 85 M&L For Precast Cement Concrete Block Masonary With Solid Block (Size 30 X 20X 10 Cm As In Edging,Type B11:2:4(20 Mm Graded Aggregate)Exc 10 Cm In Width And Setting In Mortar 1:4 Complete All As Specified And Directed. 86 M&L For Point Wiring Complete With Two 1.5 Sqmm Single Core Multistranded Copper Conductor Pvc (Fr) Insulated Cable In Pvc Concealed Conduit Of Size 19/20 Mm (Isi Marked) Including Pvc Accessories (Concealed In Wall And Surface In Ceiling Complete Including Cutting Chasing & Making Good To Disturbed Surface Etc Including Pressed Steel Terminal Boxes (Sunk In Wall) With 3 Mm Thick Plastic Laminated Sheet Top Cover With 1.5 Sqmm Insulated Un-Sheathed Pvc Insulated Single Core Multistranded Copper Conductor Common Earth And Connecting To Earth Dolly With Suitable Size Of Copper End Connector For The Following :- Note:- Colour Code Shall Be Maintained As Per Ie Rule. 87 One Light Point Controlled By One, One Way Switch 88 One Fan Point Controlled By One, One Way Switch 89 One Socket Outlet 3 Pin, 5 Amp On Independent Board 90 One Socket Outlet 3 Pin, 5 Amp On Same Board. 91 M&L For Point Wiring With 4.00 Sq Mm Single Core Multi-Stranded Copper Conductor Pvc (Fr) Insulated, Unsheathed Cable 1100 Volt Grade In Pvc Concealed Conduit Of Size 19/20 Mm (Isi Marked) Including Pvc Accessories (Concealed In Wall And Surface In Ceiling Complete Including Cutting Chasing & Making Good To Disturbed Surface Etc Including Pressed Steel Terminal Boxes (Sunk In Wall) With 3 Mm Thick Plastic Laminated Sheet Top Cover With 4.0 Sq Mm Single Core, Multi-Stranded Copper Conductor, Pvc Insulated, Unsheathed Cable For Common Earth And Connecting For Earth Dolly For 5 Pin, 15 Amp Socket Outlet On Independent Board. 92 S&F Of Switch Piano Flush Type Single Pole One Way 5 Amp (Isi Marked) 93 S&F Of Switch Piano Flush Type Single Pole One Way 15 Amp (Isi Marked) 94 S&F Of Socket Out Let 2 In 1, 3 Pin 5 Amp Flush Type (Isi Marked) 95 S&F Of Socket Out Let 2 In 1, 3 Pin 15 Amp Flush Type (Isi Marked ) 96 M&L For Ceiling Rose, Surface Bakelite 65 X 17.50 Mm Of Three Terminals Pvc/Polycarbonate, Isolated Body (Isi Marked) Complete All As Specified And As Directed. 97 Supply, Installation, Testing And Commissioning Of 20 Watt 4 Ft Long Led Batten Housing Made Of Extruded Alluminium With Milky White Diffuser And Inbuilt Electronic Driver System Lumen Output Should Be At Least 2000 Lumen With A Cct Of 6000 K, Power Factor Should Be Greater Than 0.9 With All Accessories And Connecting Up Complete With 3 Core Flexible Cable White Of Size 23/0.0076 Complete All As Specified And As Directed. 98 S&F Of Led Luminaire 600 Mm X 600 Mm, 35/36 Watt, 220 V Ac Recessed Type With High Efficiency Pmma Diffuser Soft Glare Free Light Complete With Driver, Holders & Led Lamp Suitable For Roof Ceiling Including Connecting Up With Driver Three Core Flexible Copper Conductor Cases Of Suitable Size Complete A Cct Of 6000 K, Power Factor Should Be Greater Than 0.9 With All Accessories And Connecting Up Complete With 3 Core Flexible Cable White Of Size 23/0.0076 Complete All As Specified And As Directed. 99 Supply And Install Split Ac Indoor/Outdoor 1.5 Tr With In Built Heating And Cooling Operation And Digital Inverter Twin Rotary Compressor, Ac,230V,Single Phase, With Cordless Remote Control Unit With In Built Air Ioniser And Plasma Filter For Better Indoor Air Quality With Minimum 5 Star Rating And Eer 3.2.Of Capacity And Complete Ac Mounting Stand Along With Clamps, Nuts, Bolts, Washers Etc; Extra Cooper Tubing With Proper Insulation, Pvc Drain Pipe Of Suitable Length, Sheet Metal Enclosure, Single Pole And Neutral With Two Pin And Earth Plug And Socket With Mcb 20A, Suitable For Protection Of Appliances Like Ac/Geyser Suitable For Flush Mounting And Surface Mounting Complete All As Specified And As Directed. 100 S&F Of Led Bldg Security Light Fitting 35 W Housing Made Out Of Die Cast Aluminum Alloy With Toughed Glass, Ip 65/66 Protection Having Clamp For Mounting On Wall Working On 240 V Ac 50 Hz, 20 Watts Including Fixed On Wall With 02 Nos Ms Clamps And Bracket Made Of 40 Mm Dia Light Grade Gi Pipe Bend To Shape Complete All As Specified And As Directed. 101 Supply, Install, Testing And Commissioning Of Commercial Air Curtains Of Size 40\ X 90\ Unit For Prevention Of Dust And Conditioned Air Losses, Single Phase, 240 V, 50 Htzs Made Out Of Ms/Crca 18 Gauge Finished With Two Coat Of Red Oxide Primer And Final Coat Of Synthetic Enamel Paint(Oven Baked) With Square Perforated Suction Greels, Aluminium Alloys Fans And Single Phase Electric Motor, Nozle Etc, Complete With Fittings And Accessories So As To Produce 1 -1.5 M/Sec Air Velocity At Floor Level For Door Openeing Specified Complete All As Specified And As Directed. 102 S&F Of Voltage Stabilizer For Automatic Operation, Single Phase Each Naturally Air Cooled Indoor Type & Designed For Input Variation Between 170 V To 250 V With Output Voltage Stabilized At 230 V-With Accuracy Of ± 2.5% And Of Capacity 4 Kva Complete All As Specified And As Directed. 103 S&F Of Db Epoxy Powder Coated Tp & N 4 Ways (Vtpn Mccb Db) With Metal Door (Ip 54 Ik 09 Protection) Fabricated From Minimum 1.6 Mm Thick Crca Sheet And Fixed Flush To Wall And Suitable For Universal Mounting And Including 200 Amps Copper Bus Bar, Neutral Bar, Standard Din Rail, Earth Bar And Cable Ties For Cable Management, Top And Bottom Removable Gland Plates With Knockouts And Suitable For One Fp Mccb 63 Amps As Incomer And 12 Sp Mcbs Or 4 Tp Mcbs (Or Any Combination Of Sp/Tp Mcbs) Outgoings Complete All As Specified And As Directed.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 01-Aug-2026 | Corrigedum No 01 | Date | 24-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : Garrison Engineer Kapurthala Name of Work : Certain provision works in the AOR of AGE B/R-II under GE Kapurthala Contract No : GE KPT- /2026-27 Bidder Name : SCHEDULE OF WORKS(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # S.No Description of work Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder Rs. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Excavating in trenchs not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth; for foundation, etc. and not exc 10 Sqm on plan in any type of soil and getting out complete all as specified and directed. |
| 3 | M&L for plain cement concrete (1:3:6) type C-2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed. |
| 4 | M&L for plain cement concrete (1:2:4) type B-2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed. |
| 5 | M&L for reinforced concrete 300 mm dia pipe class NP-3 laid and jointed complete with collars, complete all as specified and directed. |
| 6 | M&L for rendering 15mm thick on fair faces brick surfaces in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and directed. |
| 7 | M&L for three coats of white washing on walls including reparing of new ( plastered or unplastered ) surfaces complete all as specified and directed. |
| 8 | M&L for plain cement concrete (1:3:6) type C-2 using 40mm graded stone aggregate as in bed of surface channels and drains complete all as specified. |
| 9 | M&L for brick work with sub class 'B' burnt clay bricks (old size bricks) straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and directed. |
| 10 | M&L for brick work with sub class 'B' burnt clay bricks (old size bricks) straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:4 complete all as specified and directed. |
| 11 | M&L for flush pointing to brick walls with cement mortar 1:3 complete all as specified and directed. |
| 12 | M&L for roviding cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in copings, kneelers, apex stones, bed plates etc including necessary form work complete all as specified and directed. |
| 13 | Extra for forming fair finish to drain or channel of cement concrete, 30cm inner girth, using extra cement including forms moulds/mitered stopped ends etccomplete all as specified and directed. |
| 14 | M&l for pre-cast reinforced cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in manhole covers , drain covers and set in cement mortar (1:4) including form work complete all as specified and directed. (Reinforcement measured separately). |
| 15 | M&L for framed mild steel work of grade E-165 (Fe-290) as in framed work such as doors, gates or flat iron frame work for drain covers etc,complete all as specified and directed. |
| 16 | Excavating over areas in soft/loose soil not exc 1.5 m deep and getting out complete all as specified and directed. |
| 17 | Excavating over areas in soft/loose soil exc 1.5m deep and n.exc 3.0 m deep and getting out complete all as specified and directed. |
| 18 | Use & waste fair finished flat surfaces formwork to faces of walls, retaining walls, abutments, parapets and staircase railing and similar work including attached pillasters, buttresses, etc; vertical or to better complete all as specified and directed. |
| 19 | M&L for reinforced cement concrete design mix M-25 (20mm graded aggregates) in walls, retaining walls, basement walls and the like; any thickness; above top of footings; including attached pilasters and buttresses complete all as specified and directed. |
| 20 | M&L for TMT bars 10mm dia and over, cut to length, bent to shape required including cracking bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia complete all as specified and directed. |
| 21 | M&L for TMT steel bars 6mm to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 22 | M&L for TMT steel bars 5 mm dia and over upto and including 10mm dia as in stirrups, spacers and binders, cut to length , bent to shape required inluding cranking bending hooking ends and binding with and including mild steel wire (annealed ) not less than 0.9mm dia or securing with clips complete all as specified. |
| 23 | M&L for rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates of Fe-290 grade E-250 complete all as specified and directed. |
| 24 | S&F of GI steel expended metal of size 25*25mm cut to length, bent to shape required and tying with and including annealed mild steel wire galvanized, steel staples and fixed to wood or steel members, weight not exceeding 4 Kg per square metre complete all as specified and directed. |
| 25 | M&L for boring 300mm dia holes 10m deep in any type of soil for under-reamed piles and getting out and disposal of spoil to a distance of n.exc 50 m complete all as specified and directed. |
| 26 | S&F of UPVC pipes (SCH-40) (Slotted) 150mm bore dia incl all necessary fitting complete all as specified and directed. |
| 27 | S&F of UPVC pipes (SCH-40) (Blind)150mm bore dia incl plug cap and all necessary fitting complete all as specified and directed.. |
| 28 | M&L for filling 12.5mm graded coarse aggregates in harvesting pit upto height 0.50m complete all as specified and directed.. |
| 29 | M&L for filling 3mm to 5mm PEA gravel in harvesting pit complete all as specified and directed. |
| 30 | M&L for filling coarse sand in harvesting pit upto height 0.50m complete all as specified and directed. |
| 31 | Returning, filling in (soil) including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in any type of soil complete all as specified and directed. |
| 32 | Removal of excavated material (soil) to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. |
| 33 | Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in soft/loose soil aconcrete all as directed. |
| 34 | M&L for cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation, filling and mass concrete all as specified and directed. |
| 35 | Form work to sides of concrete fdn footing base of columns and raft beams sides and soffits (if any) of fdn and plinth beams and similar wk vertical or to batter for rough finished surfaces. |
| 36 | Form work to sides of pillars, posts, struts, pier, columns square, rectangular or polygonal rough finished surface of concrete. |
| 37 | Form work to sides and soffits of floor or roof beams, beam haunching, lintel etc rough finished surfaces of concrete flats. |
| 38 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; exceeding 200mm thick (Horizontal or sloping) all as specified and directed. |
| 39 | M&L for RCC M-25 design mix as in foundation, including raft, fooling fdn beams, plinth beams bases for columns and mass concrete complete all as specified and directed. |
| 40 | M&L for RCC M-25 design mix as in plinth beams, roof beam, cantilivers, bressummers, lintel over 1.5m span complete all as specified and directed. |
| 41 | M&L for RCC M-25 design mix as in columns , pillars, piers, posts and struts etc. complete all as specified and directed. |
| 42 | M&L for RCC M-25 as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs, chhajja and in shelves and the like complete all as specified and directed. |
| 43 | M&L for old size brick work with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 44 | M&L for rendering 15mm thick on fair faces brick surfaces in cement mortar 1 : 4 finished even and smooth without using extra cement including WPC @ 3% of wt of cement complete all as specified and directed. |
| 45 | - ditto - all as per item No 43 here-in-before but in cement mortar 1:6 complete complete all as specified and directed. |
| 46 | M&L for rendering 10mm thick on fair faces of concrete surfaces surfaces in cement mortar 1 : 3 as in ceiling finished even and smooth without using extra cement complete all as specified and directed. |
| 47 | M&L for preparation of new plastered surfaces of walls and applying 2mm thick of birla white putty to obtain the true line to achieve smooth surface and applying two coats of oil bound distermper complete all as specified and directed. |
| 48 | M&L for applying two coats of exterior emulsion (Apex) paint on newly plastered or unplastered wall surface over a coat of cement primer including preparation of surfaces, complete all as specified and directed. |
| 49 | M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash on ceiling complete all as specified and directed. |
| 50 | M&L for hardcore of gauge n.exc. 63 mm, deposited, spread and levelled in layers n.exc 15 cm thick, watered and rammed to a true surface under floor and plingh protection all as specified and directed. |
| 51 | M&L for 100mm thick cement concrete type B- 2, 1:2:4 (40mm graded aggregate) as in floor over hard core complete all as specified and directed. |
| 52 | M&L for 25mm thick plain cement concrete type B-1, 1:2:4 (12.5mm graded aggregate) as on roof paddings complete all as specified and directed. |
| 53 | M&L for 75mm thick PCC 1:3:6 type C2 as in plinth protection/hard standing finishing the surface even and smooth with out using extra cement complete all as specified and directed. |
| 54 | M&L for anti-termite treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed. |
| 55 | M&L for anti-termite treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface |
| 56 | M&L for Anti-termite treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area |
| 57 | M&L for 40mm thick in cement concrete mortar 1:2:4 type B-0, damp proof course to horizontal or vertical surfaces including necessary formwork complete all as specified and directed. |
| 58 | M& L for applying evenly a coat of blown type bitumen at the rate of 1.50 kg per square metre and blinding with clean dry sand @ 0.05 cum per sqm complete all as specified and directed. |
| 59 | M&L for polythene film, 50 micron thick, laid on a coat of bitumen primer, @ 0.30 to 0.50 kg per sqm complete all as specified and directed. |
| 60 | S&F of factory made uPVC white colour Two track two panels sliding glazed window upto 1.50m height made of (small series) frame 52 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 1.75 sqm) comprising of uPVC multi-chambered frame, with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, complete all as specified and directed. (Glass or wiremesh shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 61 | S&F of 5.50mm thick plain sheet glass, one side sheet glass is groundor obscured or frosted in squares exc 0.5 sqm each pane and glazing with metal beads complete all as specified and directed. |
| 62 | M&L for light shade vitrified ceramic tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed complete all as specified and directed. |
| 63 | - ditto - all as per item No 62 but in vertical surfaces over 10mm plastercomplete all as specified and directed. |
| 64 | S&F of anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer in-charge. |
| 65 | Supply and fixing factory made uPVC door frame made of uPVC. extruded sections having an overall dimension (extruded section profile) 48x40 mm (tolerance ± 1 mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete all as specified by the manufacturer and as per directions of Engineer-in-charge |
| 66 | Supply and fixing factory made uPVC white colour casement door with 3D hinges made of (big series) frame 67 x 64 mm & sash 67 x 110 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door upto 2.00 sqm) comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality complete all as specified and directed. (Glass shall be paid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 67 | S&F of aluminium (die cast body) door closer hydraulically regulated designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed. |
| 68 | M&L for preparation of newly plastered surface making surface completely dry and applying a coat of bitumen primer @ 0.40 ltr/sqm and after drying of primer apply APP modified water proofing membrane with non woven polyster reinforcement 3mm thick superior multipolymeric weighing not less than 3kg/sqm with properties of high penetration and centre core consisting of 90 micron high molecular high density polyethylene (MHHDPE) film consisting of five layers with a coat of hot blown bitumen 85/25 @ 1.20 kg/sqm under and over the APP membrane laid with torching application to the surface complete and sealing the side as well as end laps (overlaps should not be less than 10 cm) and applying two coats of aluminium paint above APP membrane surface , complete all as specified and directed. |
| 69 | S&F of heat resistant terrace tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. |
| 70 | Excavation in post holes (or similar holes) each n exc 0.5 cum, getting out , returning filling in layers not exceeding 25cm including watering and ramming and removing surplus earth to a distance not exceeding 50 metre complete all as specified and directed. |
| 71 | M&L for plain cement concrete (1:5:10) type D-2 using 40mm graded stone aggregate as in foundation filling and mass concrete and as in sub base of floors complete all as specified. |
| 72 | S&F of steel work in tubular trusses, rafters and posts etc including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS-1161-1979 (grade st-240 ) complete all as specified and directed. |
| 73 | S&F for plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe-410-W (Gde-E-250) quality B complete all as specified and directed. |
| 74 | M&L for pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 75 | S&F of pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 76 | M&L for two coats of cement base paint, white or tinted on walls / vertical surfaces incl preparing of new ( plastered or unplastered ) surfaces with chalk whiting priming complete all as specified and directed. |
| 77 | M&L for preparation of new or previously untreated steel surfaces of any description , over 10 cm width or girth not otherwise described for and priming with red oxide and applying two coat of synthetic enamel paint over priming coat all as specified end as directed. |
| 78 | M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS-15658 - 2006 of 60mm thick ness, M-35 grade with grey cement and pigment over sand cushioning complete all as specified and directed. |
| 79 | M&L for 25mm fine sand filling under floor or in foundations in layers including watering and consolidation complete all as specified and directed. |
| 80 | M&L for 25 mm thick cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregates finished even & smooth without using extra cement complete all as specified and directed. |
| 81 | M&L for non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11sqm but n.exc 0.18 Sqm in floor set and jointed in neat cement slurry and pointed in white or colour cement to match the tiles, with 15 mm thick cement screed bed in CM (1:6) complete all as specified and directed. |
| 82 | M&L for rolled sections Fe 410-W(Gde-E-250) Quality -A as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates, etc. complete all as specified and directed. |
| 83 | M&L for roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.Fe-410(Gde-E250) complete all as specified and directed. |
| 84 | S&F of mild steel screw bolts 16mm dia (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 22.5cm and n.exc 30cm long complete all as specified and directed. |
| 85 | M&L for precast cement concrete block masonary with solid block (size 30 x 20x 10 cm as in edging,type B11:2:4(20 mm graded aggregate)exc 10 cm in width and setting in mortar 1:4 complete all as specified and directed. |
| 86 | M&L for point wiring complete with two 1.5 Sqmm single core multistranded copper conductor PVC (FR) insulated cable in PVC concealed conduit of size 19/20 mm (ISI Marked) including PVC accessories (concealed in wall and surface in ceiling complete including cutting chasing & making good to disturbed surface etc including pressed steel terminal boxes (sunk in wall) with 3 mm thick plastic laminated sheet top cover with 1.5 Sqmm insulated un-sheathed PVC insulated single core multistranded copper conductor common earth and connecting to earth dolly with suitable size of copper end connector for the following :- Note:- Colour code shall be maintained as per IE rule. |
| 87 | One light point controlled by one, one way switch |
| 88 | One fan point controlled by one, one way switch |
| 89 | One socket outlet 3 Pin, 5 Amp on independent board |
| 90 | One socket outlet 3 Pin, 5 Amp on same board. |
| 91 | M&L for point wiring with 4.00 Sq mm single core multi-stranded copper conductor PVC (FR) insulated, unsheathed cable 1100 volt grade in PVC concealed conduit of size 19/20 mm (ISI Marked) including PVC accessories (concealed in wall and surface in ceiling complete including cutting chasing & making good to disturbed surface etc including pressed steel terminal boxes (sunk in wall) with 3 mm thick plastic laminated sheet top cover with 4.0 Sq mm single core, multi-stranded copper conductor, PVC insulated, unsheathed cable for common earth and connecting for earth dolly for 5 pin, 15 Amp socket outlet on Independent board. |
| 92 | S&F of switch piano flush type single pole one way 5 Amp (ISI Marked) |
| 93 | S&F of switch piano flush type single pole one way 15 Amp (ISI Marked) |
| 94 | S&F of socket out let 2 in 1, 3 pin 5 Amp flush type (ISI Marked) |
| 95 | S&F of socket out let 2 in 1, 3 pin 15 Amp flush type (ISI Marked ) |
| 96 | M&L for ceiling rose, surface bakelite 65 x 17.50 mm of three terminals PVC/Polycarbonate, isolated body (ISI Marked) complete all as specified and as directed. |
| 97 | Supply, installation, testing and commissioning of 20 watt 4 ft long LED batten housing made of extruded alluminium with milky white diffuser and inbuilt electronic driver system lumen output should be at least 2000 lumen with a CCT of 6000 K, power factor should be greater than 0.9 with all accessories and connecting up complete with 3 core flexible cable white of size 23/0.0076 complete all as specified and as directed. |
| 98 | S&F of LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete a CCT of 6000 K, power factor should be greater than 0.9 with all accessories and connecting up complete with 3 core flexible cable white of size 23/0.0076 complete all as specified and as directed. |
| 99 | Supply and install split AC indoor/outdoor 1.5 TR with in built heating and Cooling operation and digital Inverter twin rotary compressor, AC,230V,single phase, with cordless remote control unit with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity and complete AC mounting stand along with clamps, nuts, bolts, washers etc; extra cooper tubing with proper insulation, PVC drain pipe of suitable length, sheet metal enclosure, single pole and neutral with two pin and earth plug and socket with MCB 20A, suitable for protection of appliances like AC/Geyser suitable for flush mounting and surface mounting complete all as specified and as directed. |
| 100 | S&F of LED Bldg security light fitting 35 W housing made out of die cast aluminum alloy with toughed glass, IP 65/66 protection having clamp for mounting on wall working on 240 V AC 50 Hz, 20 watts including fixed on wall with 02 Nos MS clamps and bracket made of 40 mm dia light grade GI pipe bend to shape complete all as specified and as directed. |
| 101 | Supply, install, testing and commissioning of commercial Air Curtains of size 40\\" x 90\\" unit for prevention of dust and conditioned air losses, single phase, 240 V, 50 Htzs made out of MS/CRCA 18 gauge finished with two coat of red oxide primer and final coat of synthetic enamel paint(oven baked) with square perforated suction greels, aluminium alloys fans and single phase electric motor, nozle etc, complete with fittings and accessories so as to produce 1 -1.5 m/sec air velocity at floor level for door openeing specified complete all as specified and as directed. |
| 102 | S&F of voltage stabilizer for automatic operation, single phase each naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V-with accuracy of ± 2.5% and of capacity 4 KVA complete all as specified and as directed. |
| 103 | S&F of DB epoxy powder coated TP & N 4 ways (VTPN MCCB DB) with metal door (IP 54 IK 09 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts and suitable for one FP MCCB 63 Amps as incomer and 12 SP MCBs or 4 TP MCBs (or any combination of SP/TP MCBS) outgoings complete all as specified and as directed. |
| 104 | S&F of MCCB, 63 Amp, 4 Pole, 415 Volt complete all as specified and as directed. |
| 105 | S&F of MCB, 6 to 32 Amp, SP , 230 Volt complete all as specified and as directed. Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 18 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender