Tender for Electrification Of Pullural Anganvadi In Ward 2, Manjeri Municipality - Annual Plan (Project No.1076/26)
BOQ
| Sl. No. | Item Description |
| 1 | Electrification |
| 2 | 1.10.3Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mmFRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C |
| 3 | 90.3.20.3Supply & installation of light fittings on TW round blockSupply, conveyance installation testing and commissioning the light fittings offollowing types made of CRCA with 0.5mm thickness complete with all accessoriesand lamps etc. directly on wall or ceiling with PVC round block neatly painted to suitthe fitting and giving connection with required length of 16/0.20mm 3 core copperconductor flex wire conforming to relevant ISS and giving connections asrequired.1200 mm 1X20W LED Lamp with box type fixture |
| 4 | 90.3.21.3Supply & installation of light fittings on 'C/U' shaped flat iron bracketSupply, conveyance, installation, testing and commissioning the light fittings offollowing types made from 0.5mm CRCA sheet complete with all accessories andlamps etc. directly on wall using 2 nos. 'C/U' brackets made from 20 x 3 mm MS flat,painting the flat iron bracket and giving connections with required length of16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS orextending the original wiring and giving connection etc. as required.1200 mm1X20W LED Lamp with box type fixture |
| 5 | 1.58Supplying and fixing PVC batten/ angle holder including connection etc. as required. |
| 6 | OD84448/2026-2027Supplying and fixing 9W LED Bulb. as required |
| 7 | OD84580/2026-2027Supply, conveyance, installation, testing and commissioning of 9/10W LED bulkheadlight fittings directly on the wall, including giving connections with the requiredlength of 16/0.20mm 3-core round copper conductor flex wire conforming to relevantISS, making good the damages, colour washing etc as required. |
| 8 | OD94566/2026-2027Supply, installation, testing and commissioning of 1200 mm sweep BEE-5 star ratedceiling fan with brushless direct current motor (BLDC) , class of insulation B , 3 no'sblades , 30 cm long down rod , 2no:s canopies, shackle kit, safety rope , copperwinding, power factor not less than .9, service value (CM/M/W) minimum 6.00, Airdelivery minimum 210 cum/min,350 RPM (tolerance as per IS :374-2019, THD lessthan 10% remote or electronic regulator unit for speed control and all remainingaccessories including safety pin, nut and bolts , washers, temperature rise equal to 75deg celsius (maximum) , insulation resistance more than 2 Megaohm , suitable for 230V,50 Hz,single phase AC supply , earthing etc., complete as required: |
| 9 | 1.25Supplying and fixing two module stepped type electronic fan regulator on the existingmodular plate switch box including connections but excluding modular plate etc. asrequired. |
| 10 | 90.4.1Supply and installation of suitable size MS rod type fan clamp in the RCC slab as perIS 732 as required. |
| 11 | 90.4.2Supply and installation of suitable size MS belt type fan clamp fabricated from flatiron 40 x 6 mm, 150mm long x 2 Nos with M.S. rod bent to shape, neatly paintedwith 2 coats of enamel paint over a coat of red oxide primer as per IS 732 as required. |
| 12 | 1.47Supplying and fixing extra down rod of 10 cm length G.I. pipe, 15 mm dia, heavygauge including painting etc. as required. (Note: More than 5 cm length shall berounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 13 | 90.4.8Charges for cutting holes suitable for accommodating exhaust fans up to 305mmsweep including plastering colour washing etc. as required |
| 14 | OD84610/2026-2027Supply, conveyance, installation , testing and commissioning of 250 mm sweep LightDuty Exhaust fan in plastic body with self opening lowers workingon230V singlephase A/C, fixing necessary anchor bolts / bolt and nuts etc., as required includinggiving connections with the supplied wire along with the exhaust fan. |
| 15 | 90.5.1.3Supply and fixing the following types of superior quality 250V A.C call bell onexisting M.S. box and giving connections with required length of 3 core, 16 / 0.20mm650/1100V grade PVC insulated and PVC sheathed round copper conductor flex wireconforming to relevant ISS or with the extended original wiring, earthing the MS boxand making good the surface as required.Ding dong bell |
| 16 | 1.33Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ woodenblock including connection etc as required. |
| 17 | 1.31Supplying and fixing suitable size GI box with modular plate and cover in front onsurface or in recess, including providing and fixing 3 pin 5/6 amps modular socketoutlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to beused in non residential buildings). |
| 18 | 1.27.1Supplying and fixing following size/ modules, GI box alongwith modular base &cover plate for modular switches in recess etc as required.1 or 2 Module(75mmX75mm) |
| 19 | 1.27.2Supplying and fixing following size/ modules, GI box alongwith modular base &cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) |
| 20 | 1.27.4Supplying and fixing following size/ modules, GI box alongwith modular base &cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) |
| 21 | 1.24.1Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. as required.5/6amps switch |
| 22 | 1.24.3Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.15/16 amp switch |
| 23 | 1.24.4Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. as required.3pin 5/6 amp socket outlet |
| 24 | 1.24.5Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. as required.6pin 15/16 amp socket outlet |
| 25 | 90.10.3.15Supply and Fixing the following modular switches & accessories in the existing frontplates and giving necessary connections as required (RoHS compliant )32A DPswitch with indicator |
| 26 | 2.3.3Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)12 way, Double door |
| 27 | 2.10.1Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 28 | 2.12.1Supplying and fixing following rating, double pole, 240 volts, isolator in the existingMCB DB complete with connections, testing and commissioning etc. as required.40amps |
| 29 | 2.14.2Supplying and fixing following rating, double pole, (single phase and neutral),240volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milliamperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required. 40 amps |
| 30 | 1.17.3Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X1.5 sq.mm |
| 31 | 1.17.6Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x1.5 sq. mm |
| 32 | 1.17.12Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x2.5 sq. mm |
| 33 | 1.17.21Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x4 sq. mm |
| 34 | 1.17.23Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.5 x4 sq. mm |
| 35 | 1.21.1Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.20 mm |
| 36 | 1.21.2Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.25 mm |
| 37 | 5.4Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick includingaccessories, and providing masonry enclosure with cover plate having lockingarrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt asrequired. |
| 38 | OD84446/2026-2027Providing and fixing 2 X 25 mm X 3 mm G.I. strip test joint for earthing system |
| 39 | OD84453/2026-2027Providing and fixing 25 mm X 3 mm G.I. strip earth lead from the test joint to theearth plate |
| 40 | OD84452/2026-2027Supply and providing 25x6mm brass bolt |
| 41 | 90.16.1.3Supply and drawing bare earthing conductors of the following sizes along withwiring/ cables and giving connection as required3.15 mm copper conductor ( 10SWG) |
| 42 | 90.16.5.3Supply of superior quality copper earth socket for the following size of earthconductor including crimping etc. as required.3.15 mm (10 SWG) |
| 43 | 2.16Supplying and fixing DP sheet steel enclosure on surface/ recess along with25/32amps 240 volts "C" curve DP MCB complete with connections,testing and commissioning etc. as required |
| 44 | OD84450/2026-2027Supply & installation of dust and vermin proof, 1 Phase Syntax Meter Board(GS-MB- 3525) and to fix KSEB meters, fuse units, CT etc as required includingfixing it on wall, making good the damages colour washing etc. as required. |
| 45 | OD84447/2026-2027Supplying and fixing 32 A, 2 Way neutral links mounted on DMC/SMC base withconnections, in existing meter board |
| 46 | OD84449/2026-2027Supplying and fixing 32A, HRC Fuse with HRC Fuse link with connections, inexisting meter board |
| 47 | OD84451/2026-2027Supply and providing suitable Iron Hook Grouted on wall for binding the service wire Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 03, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
TodayAug 11, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 1 dayTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender