Tender For Electrification Of The Kudumbasree Office Building In Manjeri Municipality Under The Annual Plan (Project No. 669/26)
Tender Value
2.39 Lakhs
Estimated cost
Bid Submission
10 Aug 2026
0 days left
EMD
5976
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Malappuram → Kerala
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Electrification Of The Kudumbasree Office Building In Manjeri Municipality Under The Annual Plan (Project No. 669/26)
BOQ
| Sl. No. | Item Description |
| 1 | Electrification |
| 2 | 1.10.3Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mmFRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C |
| 3 | 1.55.3Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bellpoint ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copperconductor single core cable in surface/ recessed PVC conduit, and earthing the pointwith 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. asrequired.Group C |
| 4 | OD84853/2026-2027Supply, Conveyance, installation, testing and commissioning of 1200 lumenround/square (0.5ftX0.5ft) LED surface/recess fitting made of die cast aluminum,having efficacy not less than 110l/w, pf greater than 0.95, THD less than or equal to10% directly on ceiling and giving connections with 16/0.20mm 3 core PVC insulatedand sheathed round copper conductor flexible wire or extending the original wiringand giving connections as required.(Chip make Cree/Osram/lumilled/Nichea) orequivalent make |
| 5 | 1.58Supplying and fixing PVC batten/ angle holder including connection etc. as required. |
| 6 | OD84851/2026-2027Supplying and fixing 9W LED Bulb. as required |
| 7 | 90.15.4.7Supply Conveyance, installation, testing and commissioning of 100W LED Floodlight output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chipmake Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internalsurge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98,RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartmentshould be seperatly accessible for maintenance (LM 79&80 certificates fromNABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 8 | OD84852/2026-2027Supply, conveyance, installation, testing and commissioning of 400/450mm sweepwall mounting fans with metallic blades, blade covers, body using mounting bracketssupplied along with the fan and giving connection as required |
| 9 | 1.31Supplying and fixing suitable size GI box with modular plate and cover in front onsurface or in recess, including providing and fixing 3 pin 5/6 amps modular socketoutlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to beused in non residential buildings). |
| 10 | 90.10.1.2Supply & Fixing the following types/ sizes of boxes suitable for modularaccessories in surface/ recess including making good the damages, colour washing etcas required (RoHS compliant )2 module moulded plastic box on surface |
| 11 | 90.10.1.5Supply & Fixing the following types/ sizes of boxes suitable for modularaccessories in surface/ recess including making good the damages, colour washing etcas required (RoHS compliant )6 module moulded plastic box on surface |
| 12 | 1.28.1Supplying and fixing following Modular base & cover plate on existing modularmetal boxes etc. as required.1 or 2 Module |
| 13 | 1.28.4Supplying and fixing following Modular base & cover plate on existing modularmetal boxes etc. as required.6 Module |
| 14 | 1.24.1Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.5/6 amps switch |
| 15 | 1.24.4Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.3 pin 5/6 amp socket outlet |
| 16 | 90.11.1.12Supply and installation of sheet steel, phosphatised and painted, dust and verminproof enclosure of MCB DB including copper /brass bus bar, neutral link, earth busand DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitableanchor bolts or fixed in recess including cutting hole on the wall , making good thedamages, colour washing etc. as required8 way (8+24) - three phase double cover (IP42/43) |
| 17 | 2.10.1Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 18 | 2.13.1Supplying and fixing following rating, four pole, 415 volts, isolator in the existingMCB DB complete with connections, testing and commissioning etc. as required.40amps |
| 19 | 2.15.2Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required. 40 amps |
| 20 | 1.17.3Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X1.5 sq.mm |
| 21 | 1.17.4Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x1.5 sq. mm |
| 22 | 1.17.6Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x1.5 sq. mm. |
| 23 | 1.17.9Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.9 x1.5 sq. mm |
| 24 | 1.21.1Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.20 mm |
| 25 | 1.21.2Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.25 mm |
| 26 | 90.12.7.40Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armouredaluminium power cable, 1.1 KV grade of the following sizes using clamps notedalong with the cables, spacing of clamps not exceeding 60cms, making good thedamages , colour washing etc. as required.4 core 10 sq mm with factory made clamp |
| 27 | 9.1.32Supplying and making end termination with brass compression gland and aluminiumlugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductorcable of 1.1 KV grade as required.4 X 10 sq. mm (25mm) |
| 28 | 90.16.1.2Supply and drawing bare earthing conductors of the following sizes along withwiring/ cables and giving connection as required2.65 mm copper conductor (12SWG) |
| 29 | 90.16.5.2Supply of superior quality copper earth socket for the following size of earthconductor including crimping etc. as required.2.65 mm (12 SWG) |
| 30 | OD85674/2026-2027Supply and providing 25x6mm brass bolt |
| 31 | 2.1.1Providing and fixing following capacity TP&N disconnector fuse switch unitinside the existing panel board with ISI marked HRC fuses including drilling holes incubicle panel, making connections, etc. as required.32 Amp TP & N |
| 32 | OD85462/2026-2027Supplying and fixing 32 A, 2 Way neutral links mounted on DMC/SMC base withconnections, in existing meter board |
| 33 | OD85463/2026-2027Supplying and fixing 32A, HRC Fuse with HRC Fuse link with connections, inexisting meter board |
| 34 | OD85643/2026-2027Preparation and submission of test report to KSEB Ltd. for obtaining new LT serviceconnection, additional connected load, or meter replacement, including testing of theinternal electrical installation, preparation of required documents, submission of thetest report, and liaison with KSEB Ltd. officials, complete as required. (ExcludingKSEB statutory fees and demand charges.) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 03, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
TodayAug 11, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 1 dayTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender