Power Government Departments Closing in 0 days TDR #56804289

Tender For Electrification Of The Kudumbasree Office Building In Manjeri Municipality Under The Annual Plan (Project No. 669/26)

Issued by Government Departments · Malappuram, Kerala
Tender Value
2.39 Lakhs
Estimated cost
Bid Submission
10 Aug 2026
0 days left
EMD
5976
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Malappuram → Kerala
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Electrification Of The Kudumbasree Office Building In Manjeri Municipality Under The Annual Plan (Project No. 669/26)

BOQ

Name of Work:- Electrification of the Kudumbasree Office building in Manjeri Municipality under the Annual Plan (Project No. 669/26)
Sl. No. Item Description
1Electrification
21.10.3Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mmFRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
31.55.3Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bellpoint ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copperconductor single core cable in surface/ recessed PVC conduit, and earthing the pointwith 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. asrequired.Group C
4OD84853/2026-2027Supply, Conveyance, installation, testing and commissioning of 1200 lumenround/square (0.5ftX0.5ft) LED surface/recess fitting made of die cast aluminum,having efficacy not less than 110l/w, pf greater than 0.95, THD less than or equal to10% directly on ceiling and giving connections with 16/0.20mm 3 core PVC insulatedand sheathed round copper conductor flexible wire or extending the original wiringand giving connections as required.(Chip make Cree/Osram/lumilled/Nichea) orequivalent make
51.58Supplying and fixing PVC batten/ angle holder including connection etc. as required.
6OD84851/2026-2027Supplying and fixing 9W LED Bulb. as required
790.15.4.7Supply Conveyance, installation, testing and commissioning of 100W LED Floodlight output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chipmake Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internalsurge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98,RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartmentshould be seperatly accessible for maintenance (LM 79&80 certificates fromNABL accredited Third party lab to be produced mentioning chip manufacturer)
8OD84852/2026-2027Supply, conveyance, installation, testing and commissioning of 400/450mm sweepwall mounting fans with metallic blades, blade covers, body using mounting bracketssupplied along with the fan and giving connection as required
91.31Supplying and fixing suitable size GI box with modular plate and cover in front onsurface or in recess, including providing and fixing 3 pin 5/6 amps modular socketoutlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to beused in non residential buildings).
1090.10.1.2Supply & Fixing the following types/ sizes of boxes suitable for modularaccessories in surface/ recess including making good the damages, colour washing etcas required (RoHS compliant )2 module moulded plastic box on surface
1190.10.1.5Supply & Fixing the following types/ sizes of boxes suitable for modularaccessories in surface/ recess including making good the damages, colour washing etcas required (RoHS compliant )6 module moulded plastic box on surface
121.28.1Supplying and fixing following Modular base & cover plate on existing modularmetal boxes etc. as required.1 or 2 Module
131.28.4Supplying and fixing following Modular base & cover plate on existing modularmetal boxes etc. as required.6 Module
141.24.1Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.5/6 amps switch
151.24.4Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.3 pin 5/6 amp socket outlet
1690.11.1.12Supply and installation of sheet steel, phosphatised and painted, dust and verminproof enclosure of MCB DB including copper /brass bus bar, neutral link, earth busand DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitableanchor bolts or fixed in recess including cutting hole on the wall , making good thedamages, colour washing etc. as required8 way (8+24) - three phase double cover (IP42/43)
172.10.1Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole
182.13.1Supplying and fixing following rating, four pole, 415 volts, isolator in the existingMCB DB complete with connections, testing and commissioning etc. as required.40amps
192.15.2Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required. 40 amps
201.17.3Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X1.5 sq.mm
211.17.4Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x1.5 sq. mm
221.17.6Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x1.5 sq. mm.
231.17.9Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.9 x1.5 sq. mm
241.21.1Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.20 mm
251.21.2Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.25 mm
2690.12.7.40Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armouredaluminium power cable, 1.1 KV grade of the following sizes using clamps notedalong with the cables, spacing of clamps not exceeding 60cms, making good thedamages , colour washing etc. as required.4 core 10 sq mm with factory made clamp
279.1.32Supplying and making end termination with brass compression gland and aluminiumlugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductorcable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
2890.16.1.2Supply and drawing bare earthing conductors of the following sizes along withwiring/ cables and giving connection as required2.65 mm copper conductor (12SWG)
2990.16.5.2Supply of superior quality copper earth socket for the following size of earthconductor including crimping etc. as required.2.65 mm (12 SWG)
30OD85674/2026-2027Supply and providing 25x6mm brass bolt
312.1.1Providing and fixing following capacity TP&N disconnector fuse switch unitinside the existing panel board with ISI marked HRC fuses including drilling holes incubicle panel, making connections, etc. as required.32 Amp TP & N
32OD85462/2026-2027Supplying and fixing 32 A, 2 Way neutral links mounted on DMC/SMC base withconnections, in existing meter board
33OD85463/2026-2027Supplying and fixing 32A, HRC Fuse with HRC Fuse link with connections, inexisting meter board
34OD85643/2026-2027Preparation and submission of test report to KSEB Ltd. for obtaining new LT serviceconnection, additional connected load, or meter replacement, including testing of theinternal electrical installation, preparation of required documents, submission of thetest report, and liaison with KSEB Ltd. officials, complete as required. (ExcludingKSEB statutory fees and demand charges.) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56804289
AUTHORITY Government Departments
TENDER VALUE 2.39 Lakhs
LAST DATE 10-08-2026
Authority
Authority Name Kerala Electrical And Allied Engineering Co Limited
Work Description Tender for Electrification Of The Kudumbasree Office Building In Manjeri Municipality Under The Annual Plan (Project No. 669/26)
Basic Detail
Tender No KEL/ KEMG/85A/2026-27
Bidding Type Tender
Location
City Malappuram
State Kerala
Key Dates
Publish Date 03 Aug 2026
Submission Date 10 Aug 2026
Open Date 11 Aug 2026
Finance
Tender Value 2.39 Lakhs
Tender Fee 590
EMD 5976
Exemption Available
Document List
a4bb7b40-461a-4893-8103-c604c3e2320d.html
BOQ_1461347.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 10, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Today
Aug 11, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 1 day

Tender Documents

Download All (ZIP) ↓
html

a4bb7b40-461a-4893-8103-c604c3e2320d.html

xls

BOQ_1461347.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders