Tender For Ca No: Ge/Gos/Tok/83 Of 2026-27 : Repair/Replacement Of Sewage Line, Septic Tanks, Soak Well Drains Bdy Wall, Fencing/Gate, Day To Day E/M Complaints, Electrical Fittings/Fixtures, Dg Set, Street Light, Cooling Appliances At Different Pock
Tender Overview
Project Description
Tender for Ca No: Ge/Gos/Tok/83 Of 2026-27 : Repair/Replacement Of Sewage Line, Septic Tanks, Soak Well Drains Bdy Wall, Fencing/Gate, Day To Day E/M Complaints, Electrical Fittings/Fixtures, Dg Set, Street Light, Cooling Appliances At Different Pockets Location Under Ge (I) Gos
BOQ
| Sl. No. | Item Description |
| 1 | Demolition of brickwork or stone/ boulder masonry, built in Cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed |
| 2 | M&L Brick work with modular fly ash bricks straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and as directed |
| 3 | M&L for Brick work with modular fly ash bricks straight or curved on plan to any in half brick thiick walls radius built in CM 1:4 complete all as specified and as directed |
| 4 | M&L for Providing precast cement concrete manhole covers, Type B1 1:2:4 (20 mm graded aggregate) set in cement mortar 1:4 complete all as specified and as directed |
| 5 | M&L for Mild steel TMT bars 10 mm dia and over ,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed. |
| 6 | M&L for Mild steel TMT bars 6mm to 8mm dia ,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed. |
| 7 | M&L for chequered cement concrete tiles 25cmX25cmX25mm thick, set, joined and pointed in neat cement slurry over screed bed in floors with grey cement and pigment complete all as specified and directed. |
| 8 | M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment complete all as specified and as directed. |
| 9 | M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed. |
| 10 | M&L for 100 mm thick Cement concrete type D-2, 1:4:8 (40mm graded aggregate) in subbase of floor etc complete all as specified and as directed. |
| 11 | Demolition of unreinforced cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed |
| 12 | M&L for Cement concrete Type D2 1:4:8 (40 mm graded aggregates) in foundations, filling and mass concrete complete all as specified and as directed. |
| 13 | Renewing cement concrete tiles in patches, area n exc 5 sq.m. including removing and cleaning old tiles, preparing beds and laying or setting, jointing and pointing new or old tiles complete all as specified and as directed. |
| 14 | Excavating in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation etc etc. or for shafts, wells, cesspits,manholes, pier holes, etc. n exc 10 sq m on plan and n exc1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed. |
| 15 | Returning, filling in, including spreading levelling, watering and well ramming in layers n exc 25 cm in soft/loose soil complete all as specified and as directed. |
| 16 | Removing Excavated material not exceeding 50M and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as specified and as directed. |
| 17 | M&L for PCC in 1:2:4 Type B0 ( 12.5 mm graded aggregate) asin lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs,, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, filling of pressed steel door frames complete all as specified and directed. |
| 18 | M&L for PCC 1:3:6 Type C2 (40 mm graded aggregate) in surface channels and drains complete all as specified and as directed. |
| 19 | Excavating in post holes (or similar holes) each n exc 0.5 cum in soft soil/loose soil and getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm watering, and removing surplus soil to a distance n exc 50 m and making good surfacecomplete all as specified and as directed. |
| 20 | S&F for Joist, channel, angle, or tee sections of Fe 290 (Gde E-165) fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) complete all as specified and as directed. |
| 21 | S&F for struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc. conforming to Fe-290 Gde E-165 |
| 22 | Supply only Chain link MS galvanisd fencing 4 mm dia and 100 mm x 100 mm size mesh complete all as specified and as directed. |
| 23 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire |
| 24 | M&L for Mild steel round bars Fe-410-W (Gde.E-250) quality-A or Fe 290 (Gde -E-165) 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
| 25 | S&F for Mild steel screw bolts diameter of neck 11 to 15 mm (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 10 cm long complete all as specified and as directed. |
| 26 | S&F in repairs galvanised 2 strand, steel barbed wire 2.24 mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. complete all as specified and as directed. |
| 27 | Dismantling fencing wiremesh, any type, any size complete all as specified and as directed. |
| 28 | S&F in repairs110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors/walls complete all as specified and as directed |
| 29 | S&F in repairs 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors/walls complete all as specified and as directed |
| 30 | S&F for 110 mm bore PVC (SWR) branch piece, single (single Y) equal or unequal complete all as specified and as directed |
| 31 | S&F for 110 mm bore PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and as directed |
| 32 | S&F for 75mm bore PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and as directed |
| 33 | S&F for 110 mm bore PVC (SWR) bends any radius complete all as specified and as directed |
| 34 | S&F for 75 mm bore PVC (SWR) bends any radius complete all as specified and as directed |
| 35 | S&F for PVC (SWR) cowl of 110 mm dia complete all as specified and as directed.. |
| 36 | S&F for Stack clamps for 110 mm bore pipe, out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof |
| 37 | M&L for hardcore of broken stone or boulders guage n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed. |
| 38 | M&L for Reinforced concrete pipe 150mm bore class NP2 laid and jointed complete with collars complete all as specified and as directed. |
| 39 | M&L for cement concrete 1:4:8 type D-2 bed to 100 mm dia drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested in complete all as specified and as directed. |
| 40 | Demolition and breaking up 150 mm dia pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified and as directed. |
| 41 | S&F for rolled mild steel in steel work tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and as directed. |
| 42 | M&L for preparaton of new or previously untreated steel surfaces of any description over 10cm width or girth not otherwise described as directed and apply two coats of synthetic enamel paint over red oxide complete all as specified and as directed. |
| 43 | S&F for concertina coils super barbed bladed profile of dia 600 mm of and weight of coil per 50 spiral turns shall not be less than 9.0 kg and one coil (50 spiral) shall not be stretched to more than 6.0 mtr. Blade shall be 0.50mm thick galvanised steel strip and 2.5 mm dia core wire fixed to angle iron brackets or masonry surfaces with necessary accessories like straining wires, fixing clips etc completed all as specified and as directed. |
| 44 | Material, T&P and labour for cleaning of manhole using the cleaning devices as per Rule 5 and protective gear and safety devices as per Rule 4 of the Prohibition of Employment as Manual Scavengers and their Rehabilitation Rules 2013 and removing blockage if any and removing night soil / silted sludge / waste material outside MD land unprohibited by any authority and following the statutory law / guidelines complete all as specified and as directed. |
| 45 | M&L for removing sludge from septic tanks using the cleaning devices as per Rule 5 and protective gear and safety devices as per Rule 4 of the Prohibition of Employment as Manual Scavengers and their Rehabilitation Rules 2013 including removal of sludge water mechanically and dispose night soil / silted sludge / waste material outside MD land unprohibited by any authority and following the statutory law / guidelines as per Rule 5 and protective gear and safety devices complete all as specified and as directed. |
| 46 | Material, T&P and labour for cleaning of gully traps, Nahni traps, chamber etc using the cleaning devices as per Rule 5 and protective gear and safety devices as per Rule 4 of the Prohibition of Employment as Manual Scavengers and their Rehabilitation Rules 2013 and removing blockage if any and dispose night soil / silted sludge / waste material outside MD land unprohibited by any authority and following the statutory law / guidelines complete all as specified and as directed. |
| 47 | M&L for cleaning of sewage line of any size of dia bore with cleaning devices as per Rule 5 and protective gear and safety devices as per Rule 4 of the Prohibition of Employment as Manual Scavengers and their Rehabilitation Rules 2013 and dispose of the night soil/sludge outside MD land unprohibited by any authority and following the statutory law / guidelines as per Rule 5 and protective gear and safety devices complete all as specified and as directed. |
| 48 | M&L for rendering 15 mm thick on fair faces of external wall of brick work or stone surfaces in two layers (10 mm and 5 mm thick) in cement Mortar in 1:4 using water proofing compound in top layer (Water Proofing Compound measured separately) and finished even and smooth (without using extra lime or cement) complete all as specified and directed. |
| 49 | M&L for preparaion of newly plastered surfaces of walls and finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and as directed. |
| 50 | M&L for cement concrete 1:4:8 type D-2 bed to 150 mm dia drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested in complete all as specified and as directed. |
| 51 | M&L for chequered cement concrete tiles 25cmX25cmX25mm thick, set, joined and pointed in neat cement slurry in floors with grey cement and pigment complete all as specified and directed. |
| 52 | M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment complete all as specified and as directed. |
| 53 | M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed. |
| 54 | M&L for 100 mm thick Cement concrete type D-2, 1:4:8 (40mm graded aggregate) in subbase of floor etc complete all as specified and as directed. |
| 55 | Demolition of unreinforced cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed |
| 56 | Taking down carefully copper/aluminum point wiring (light, fan/exhaust fan, socket or power) complete with fittings and fixtures such as switches, ceiling roses, pendants, regulators, socket, lamp holders, brackets, bulk head fittings etc removing material to store for keeping in safe custody or for taking credit ( credit for above items should be made as per conditions separately ) and also making good disturbed surfaces of wall, floors etc all as specified and as directed by the Engineer-in-Charge. |
| 57 | Material and labour for point wiring with 1.5 Sqmm copper conductor (Multi-stranded) PVC insulated and unsheating FRLS electric cable 1100 volts cable and including PVC casing and caping of suitable size (as per conductor run) with all fittings/ accessories and including PVC insulated electric cable 1100 volts 1.5 Sqmm ( multi-stranded) copper conductor single core( Green colour) cable as continuous earth wire connected to common earth dolly by providing lugs including sunk in pressed steel terminal boxes of 1.6 mm thick concealed in wall (duly painted with two coats of black bituminous paint over a coat of red oxide primer in and out sides) with and including cutting holes for switches, sockets, regulators etc as per requirement including fixing with machine screw, washer etc all as specified and as directed by the Engineer-in-Charge. (a) One light point controlled by one, one way switch |
| 58 | (b) One fan/exhaust fan point controlled by one, one way switch |
| 59 | (c) One 5 Amp socket point controlled by one way switch on independent board. |
| 60 | (d) one 5 Amp Socket point controlled by one way switch on the same board with other switches. |
| 61 | All as per serial item No 57 here-in-before , but for one socket outlet 15 Amps on independent board with 2.5 Sqmm copper conductor ( Multi-stranded) PVC insulated and unsheating electric cable 1100 volts (ISI Marked) including PVC insulated and unsheathed electric cable 1100 volts 2.5 Sqmm copper stranded conductor as continuous earth wire connected to common earth dolly complete all as specified and as directed by Engineer-in-Charge. |
| 62 | Material and labour for socket outlet 2 in 1, 3 pin, 5A flush type complete all as specified and directed. |
| 63 | Material and labour for socket outlet 2 in 1, 3 pin, 5 Amp and 15 Amp flush type complete. |
| 64 | Material and labour for Switch piano flush type single pole one way 15 Amp complete. |
| 65 | Material and labour for Switch piano flush button 5 Amps complete. |
| 66 | Material and labour for ceiling rose surface type, 65 mm x 50 mm two to three terminals / PVC / polycarbonate, isolated body fixed on PVC block complete all specified and as directed by the Engineer-in-Charge. |
| 67 | Supply and fixing for sub main wiring two single core PVC insulated and unsheathed cable with 4 Sqmm multi -strand copper conductor drawing in PVC casing caping with 4 Sqmm PVC copper conductor cable as in earth wire system ,including taking out old wiring complete all as directed. |
| 68 | Supply and fix Sheet metal enclosure for DB’s suitable for MCBs of single pole and neutral 8 way (Double door) with 200 amp rated bus bar all as specified and directed. |
| 69 | Supply and fix Sheet metal enclosure for DB’s suitable for MCBs of single pole and neutral 4 way (Double door) with 200 amp rated bus bar all as specified and directed. |
| 70 | S&F Isolator DP 40A, 240 volts all as specified and directed by Engr-in-Charge. |
| 71 | S&F MCB SP up to 40 Amp, 240 volt all as directed. |
| 72 | S&F Ceiling Fan regulator electronic step type all as specified. |
| 73 | S&F modular switch single pole 1 way 6A, complete Including taking down unserviceable switch all as specified and directed. |
| 74 | S&F modular socket outlet 6A 2/3 pin combined 2 module complete Including taking down unserviceable socket all as specified and directed. |
| 75 | S&F modular switch 16A single pole one way complete Including taking down unserviceable switch all as specified and directed. |
| 76 | S&F socket outlet 6A/16A- 2/3 pin combined 2 module complete all as specified and directed. |
| 77 | M&L for modular Bell push Switch single pole one way 6A/10Amps complete Including taking down unserviceable ones all as specified and directed. |
| 78 | M&L for call bell modular type AC 230 volt single pole complete Including taking down unserviceable ones all as specified and directed. |
| 79 | M&L for fan step regulator-2 module complete Including taking down unserviceable ones all as specified and directed. |
| 80 | Supply and fixing Ceiling Fan 1200 mm sweep with blade, down rod complete all as specified and directed. |
| 81 | Supply and fixing exhaust fan 300 mm sweep, 1400 RPM with louver complete all as specified and directed. |
| 82 | Supply only AC three phase ,415V ,50Hz, digital,electronic tamper proof energy meter of rating 10 to 60 Amps covered with PVC transparent cover with optical communication port complete all as specified and directed |
| 83 | Supply only AC single phase ,1x 240V ,50Hz, digital,electronic tamper proof energy meter of rating 10 to 60 Amps covered with PVC transparent cover with optical communication port complete all as specified and directed |
| 84 | S & F LED light fitting 10 Watt , indoor decorative PC housing with extruded aluminium housing and integrated LED driver complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size incl taking down the old USNV complete all as specified and directed |
| 85 | Supply and fix LED Lamp pin type 9 watt all as specified and directed by the Engineer-In-charge. |
| 86 | Energy efficient LED integrated batten suitable for indoor applications tube light fitting 1x20 Watt 4 FT complete, all as specified and directed. |
| 87 | S&F ceiling LED down light 6 watt round/square complete including taking down old unsv complete all as specified and directed. |
| 88 | S&F ceiling LED down light 9 watt round/square complete including taking down old unsv complete all as specified and directed. |
| 89 | S&F ceiling LED down light 12 watt round/square complete including taking down old unsv complete all as specified and directed. |
| 90 | S&F ceiling LED down light 15 watt round/square complete including taking down old unsv complete all as specified and directed. |
| 91 | S&F recess/ceiling ultra slim down lights 36 watt LED (600x600mm) size, ultra slim with extruded alumininium housing and milky diffuser complete including taking down old unsv complete all as specified and directed. |
| 92 | S&F Surface mounted ultra slim down lights 36 watt LED (600x600mm) size, ultra slim with extruded alumininium housing and milky diffuser complete including taking down old unsv complete all as specified and directed. |
| 93 | Supply only Oil filled capacitor of 2.5 MFD, 240 Volt suitable for ceilling/ exhaust fan complete all as specified and directed. |
| 94 | S & F LED light fitting 1 x 10 Watt , indoor decorative and integrated LED driver complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size incl taking down the old USNV complete all as specified and directed |
| 95 | S&F LED lamp 9 Watt all as specified and directed |
| 96 | Material and labour for angular type lamp holder, PVC/ polycarbonate type with back plate suitable for 15/18 watts for batten fitting, including plastic square board of required size complete all as specified. |
| 97 | Supply and fix switch socket combination multipurpose 2 in 1 3 pin, 5 Amp flush type complete. |
| 98 | Supply and fix switch socket combination 2-in-1, 3/5 pin 5 and 15 Amp incl taking down the old USNV complete all as specified and as directed by Engr-in-Charge. |
| 99 | S & F bell push piano (Flush type) 5 Amp 240 Volts incl taking down the old unsv complete all as specified. |
| 100 | S & F bell/buzzer electric single phase 240 volt incl taking down the old unsv complete all as specified. |
| 101 | S&F Isolator DP 32A, 240 volts all as specified and directed by Engr-in-Charge. |
| 102 | S&F MCB SP 10 to 32 Amp, 240 volt all as directed. |
| 103 | Supply only down rod of ceiling fan with medium grade of 15 mm size pipe complete with drilling holes, cutting and making threads as per site requirement up to 0.50 to 1 mtr, painting with two coats of paint as existing all as specified and directed. |
| 104 | S&F Plastic enclosure without MCB SP & DP as required in site with fixing on wall/pole etc with binding/fixing material all as specified and directed by Engr-in-Charge. |
| 105 | Comprehensive maintenance of DG Set including Alternator AMF Panel for routine check up of the engine for the smooth functioning and carrying out the checks complete as per the manufactures instructions all as specified and directed by the Engineer-in-Charge for 40 KVA DG Sets installed. (A) Every 50 Hours/One month whichever is earlier (a) Repeat the daily checks (b) Check oil level in the oil bath type air cleaner (c) Check the fan belt tension. The deflection should be within 8 to 10 mm at the Centre (for details pleaser refer to the maintenance manual) (d) Check the electrical connection |
| 106 | Comprehensive maintenance of DG Set including Alternator AMF Panel for routine check up of the engine for the smooth functioning and carrying out the checks complete as per the manufactures instructions all as specified and directed by the Engineer-in-Charge for 40 KVA DG Sets installed. (a) Every 200 hours/Six month whichever is earlier (b) Repeat the 'B' Checks (c) Service the oil bath type air cleaner(d) Replace the engine main lub oil filter element & sealing ring (e) Grease the water pump bearing(f) Clean the button filter (g) Replace the Air filter (h) Replace the filter element (Oil filter, fuel filter etc) complete. (k) Replace the engine and turbocharger lubricant oil filter element (l) Check oil level in the fuel pump and top up if required (m) Drain radiator after warming the engine, change the water (n) Knock out soot from the exhaust silencer (o) Check and tighten all fasteners to the specified torque (p) Check the tighten all hose connection check and tighten all lubricant and fuel connection. |
| 107 | Servicing of radiator assembly complete for cleaning after draining out cooling water/coolant, spaces cleaning the inter coller and replace unserviceable rubber hose pipes, circlip clamps, cleaning of radiator mix with appropriate cleaning agent, de-scaling by means of scale solvent as well as neutralising agent to arrest leakages by means of brazing etc including replacement of coolant for the capacity of DG Set 40 KVA all as directed by Engr-in-charge. |
| 108 | Repair and servicing of 40 KVA Engine Kirlosker type RB 66/Cummins turbocharger assembly and replacing the service kit and reassembling testing complete, all as specified. |
| 109 | Servicing of self starter assembly of DG Set 24/12 Volts of 40 KVA capacity by disconnecting the self starter assembly from the engine and dismantling cleaning all accessories, replacing worn out parts like carbon brushes contact plates jumping levels etc and rewinding the fields coil and warnishing all as specified. |
| 110 | Supply and fixing street light fitting LED type 45 Watt new generation energy saving powder coated pressure die cast aluminum high powder with heat resistant toughened glass with lens & IP65 with high power LEDs as light source and electronic driver with GI tubing 40mm dia, mounting bracket with its clamp incl two coats of synthetic enamel paint over a coat red oxide primer and with all accessories, incl connecting of with 2 run of flexible copper conductor of size 1.5 sq mm cable from fitting to junction box, testing & commissioning complete all as specified and directed. |
| 111 | Supply and fixing decorative LED post top lantern luminaire with milky diffuser and painted aluminium deflector complete with connecting of suitable size of wire incl taking down old unsv all as specified and directed by Engr-in-Charge. |
| 112 | Supply and fixing 9W decorative LED extruded aluminium bollard light with integrate driver complete with connecting of suitable size of wire incl taking down old unsv all as specified and directed by Engr-in-Charge. |
| 113 | Supply and fixing PVC insulated copper wire 1.5 Sqmm, three core including taking out old unsv wire all as specified and directed by Engr-in-charge. |
| 114 | S&F in replacement oil filter suitable for 7.5 to 15 KVA DG set capacity as per existing size complete all as specified and directed |
| 115 | S&F in replacement diesel filter suitable for 7.5 to 15 KVA DG set capacity as per existing size complete all as specified and directed |
| 116 | S&F in replacement fan belt suitable for DG set of 7.5 to 15 KVA capacity complete all as specified and directed , |
| 117 | M&L for draining out oil from engine of DG set of any capacity, cleaning the oil chamber, supply and filling of lubricant in replacement GENSET OIL multi-grade 20W40 complete all as specified and directed. |
| 118 | S&F in replacement of coolant suitable for DG sets complete all as specified and directed. |
| 119 | Taking down Unseviceable Engine Relay unit of DG set of any capacity and S&F the same as existing make and capacity complete all as specified and directed. |
| 120 | Routine/general check-up by one skilled technician, complete testing of DG set once in every qtrly at GMS complete all as specified and directed. Note:(minimum maintenance cost up to Rs 300 deemed included in unit rate) |
| 121 | S&F in replacement of battery Copper Lead Cable with brass thumble complete all as specified and directed |
| 122 | Dismantlling the unserviceable hose pipe with tightning clamps S&F in replacement of the same size hose with clamp complete all as specified and directed |
| 123 | Draining the fuel from existing diesel tank in a seprate empty container and disconnecting from the DG set and cleaning fuel tank internally for removing sludge and testing to prevent the leakage if any and reconnecting the same in original position for the capacity of DG set 7.5 KVA to 15 KVA complete all as specified & directed. |
| 124 | Replacement of existing unsv air cleaning element inner with necessary 'O' rings for the DG sets ofcapacity 7.5 KVA to 15 KVA as that of existing make and model . |
| 125 | Dismantling radiator of 7.5 to 15 KVA DG Set complete from engine mounting frame, opening and clearing with use of acid, to clear the choked tubes, over hauling of the same, arresting the leakages with soldering, replacing the gasket including replacement of water pump seal, lub oil filter, corrossion resistor filter, reefixing back the radiator in the original position, reconnecting back and testing complete all as specified & directed. |
| 126 | Taking down unserviceable self-starter 12 volts from engine,dismantling and opening of stater and armature,replace the wornout carbon brush,pinion,ignition coil bearing,bushing, including servicing, varnishing of stater after repairing assembling,refixed to same position complete all as specified & directed. |
| 127 | Dismantling and taking out unserviceable dynamo/alternator of charging unit of battery 12 volts including opening and seviceing of field coil of stator,rotor unit, replace wornout carbon brush,bushes, Bentex pinion complete all as specified and directed. |
| 128 | Supply and replacement of lead acid battery 75 Amp, 12 Volt, complete all as specified. |
| 129 | Supply and replacement of Automatic voltage regulator (AVR) suitable for DG Set 15 KVA, complete all as specified. |
| 130 | Material & labour for Earthing using Copper earth plate electrode of size 60cm X 60cm X3.15mm thick burried directly in ground vertically at a depth not less than 2.25 mtr below normal ground level with top edge of earth plate at a depth not less than 1.5 mtr below normal ground level, earth plate surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Copper strip of size 20x3mm by means of bolts, nuts, check nuts and washers made of copper/brass and provision of GI pipe medium grade 25 mm dia for protection of earthing lead and 20mm dia for watering arrangement including funnel, wire mesh, CI pit cover and PCC chamber pit with PCC 1:2:4 type B-2 (including necessary excavation and earth work disposal of surplus soil to a distance not exceeding 50 mtr all as specified and shown on plate No 5 of SSR Part-I 2009. |
| 131 | Supply and fixing copper strip 20 x 3mm fixed with porcelain saddles not exceeding 400mm spacing and fixing screws for roof condductors and down conductors above ground or fixed on wall, roof all as specified and as directed by Engineer-in-Charge. |
| 132 | Material and labour for test point terminal block made of gun metal or phosphorus bronze of size 75 x 75 x 25mm with drilled holes and screws including 3 x 2 Nos, 8mm dia, 25mm long hexagonal head screw of brass with nuts complete duly fitted, grouted on 02 Nos., MS flat 25 x 5mm, fabricated with suitable shape and size and fixing or 02 Nos porcelain saddles for mounting of terminal block complete all as specified and as indicated. |
| 133 | Supply and fixing Air terminal single pointed aluminum rod 12mm dia and 300mm long, mounted on 40mm bore light grade GI pipe, embedded in mass concrete all as specified and as directed. |
| 134 | Supply and replacent GI pipe light grade with all fittings laid in trenches/walls of size 40 mm dia all as specified and directed by Engr-in-Charge |
| 135 | Supply and fixing street light fitting LED type 25 Watt new generation in aluminium PDC housing, toughened glasscover with IP 66 protection complete in all respect with GI tubing 25mm/40mm dia, mounting bracket with its clamp incl two coats of synthetic enamel paint over a coat red oxide primer and with all accessories, incl connecting of copper conductor cable of size 1.5 sq mm 3 core cable from fitting to junction box/conductor to street light as suitable on site, testing & commissioning complete all as specified and directed. |
| 136 | Supply and fixing decorative LED post top lantern luminaire with milky diffuser and painted aluminium deflector E-Top with low glare optical design acrylic diffuser complete with connecting of suitable size of wire incl taking down old unsv all as specified and directed by Engr-in-Charge. |
| 137 | Supply and fixing street light fitting LED type 90 Watt new generation in aluminium PDC housing, toughened glasscover with IP 66 protection complete in all respect with GI tubing 40mm dia, mounting bracket with its clamp incl two coats of synthetic enamel paint over a coat red oxide primer and with all accessories, incl connecting of with copper conductor of size 1.5 sq mm 3 core cable from fitting to junction box/conductor to street light as suitable on site, testing & commissioning complete all as specified and directed. |
| 138 | Supply and fixing LED flood light 200 watt Lumos II new generation LED with high luminous efficacy of 120 lm/w protected to IP-66 with front toughened glass complte in all respect with GI tubing reqd in site, mounting bracket with its clamp incl two coats of synthetic enamel paint over a coat red oxide primer and with all accessories, incl connecting of with copper conductor of size 2.5 sq mm 3 core with fixing arrangement suitable on site, testing & commissioning complete incl taking down old unsv any type and make all as specified and directed. |
| 139 | M & L for welding/brazing of existing earth strip connections complete for improvement of earth pits, pouring of salted water, repair to earth pit chamber with necessary earthwork, PCC, plastering, painting, replacement of funnel with wire mesh and earth pit chamber cover for existing improvement of existing earth pits all as specified and as directed. |
| 140 | Maint and servicing of window type/split type air conditioner including cleaning filter, washing with soap solution after removing from site and refixing complete all as specified and directed by Engr -in-Charge. |
| 141 | Supply and replacement unserviceable compressor (sealed unit) from split type air conditioner of capacity 1.5 Ton on position with nuts, bolts, ruber gromote and washers, connecting copper tubing by welding/flare nuts including taking out old unsv compressor of make approved by Engr-in-Charge all as specified and directed. |
| 142 | Supply and replacement running capacitor 36/45/80 MFD suitable for 1.5 Ton window type and split type air conditioner including taking down old unsv all as specified and directed. |
| 143 | Supply and replacement starting relay assembly including coat & cover and clips suitable for window/split typeair conditioner all as specified and directed. |
| 144 | Supply and replacement thermostat switch suitable for air conditioner 1.5 Ton capacity any make all as specified and directed by Engr-in-Charge. |
| 145 | Supply and replacement of blower motor suitable for 1.5 Ton window/split type air conditioner AC single phase 230 Volts including bushes, testing and commissioning complete all as specified and directed by Engr-in-Charge. |
| 146 | Supply and replacement of air filter Pad suitable for air conditioner 1.5 Ton capacity complete all as specified and directed by Engr-in-Charge. |
| 147 | Carrying out pressure leak test by nitrogen pressure for detecting leak in condensing unit, refrigerant pipe and repairing the leakage by welding or brazing of condensing unit and refrigerant pipe, putting under pressure for leak, checking after repairs of leak pipe including transporting and carrying out T&P required at site for work of 1.5 Ton capacity air conditioner all as specified and directed. |
| 148 | Flushing out by N2 and CTC, vaccumnation, supply and charging of refrigerant gas into the system for 1.5 Ton capacity air conditioner all as specified directed |
| 149 | Dismantling of defective cooling indoor/outdoor unit of 1.5 Ton capacity of split type air conditioner complete with connected piping and corded remote control etc and refixing on wall/floor after carrying out repairs and servicing and making good the disturbed surfaces all as specified and directed by Engr-in-Charge. |
| 150 | Supply and replacement of condensing unit of 1.5 Ton capacity complete with connected lead and iron stand etc including taking down old defective all as specified and directed. |
| 151 | Supply and replacement of cooling coil assembly suitable for air conditioner 1.5 Ton capacity all as specified and directed. |
| 152 | Supply and replacement suction copper pipe line heavy ½” dia with foam insulation and flair nuts from indoor to out door unit of split type air conditioner 1.5 Ton capacity all as specified and directed. |
| 153 | Supply and replacement suction copper pipe line heavy 3/8” dia with foam insulation and flair nuts from indoor to out door unit of split type air conditioner 1.5 Ton capacity all as specified and directed. |
| 154 | Supply and install hi wall split unit indoor and outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better in door air quailty with minium 5 star and EER 3.2 of capacity 1.5 ton including connecting and testing complete allas specified and as directed by Engr-in-charge. |
| 155 | S&F single pole and neutral enclosure with a two pin and earth plug socket 240 volt with one MCB SP ‘C’ series rating 20 to 32 Amp incl taking down the old USNV complete all as specified and directed. |
| 156 | Supply and replacement heating unit (element) ISI marked of 1500 watts triangular/circuler shape as per sample required in existing geysers installed at site including rubber washers complete all as specified and directed. |
| 157 | Supply and replacement thermostat range 0°-75°C for the geysers of 25 to 35 litres as per sample required in existing geysers installed at site complete, all as specified and directed. |
| 158 | Supply and replacement safety valve/high pressure valve 15 mm complete, all as specified and as directed. |
| 159 | Supply and replacement PVC threaded tough rubber flexible pipe/tubing of 15 mm size with PTMT nuts at both end 300/450 mm long for geysers inlet/ outlet connections, all as specified. |
| 160 | Supply and replacement Indicator lamp rectangular/round type as required at site all as specified and directed. |
| 161 | Taking down from existing location and refixng after maintenance and servicing of window type / split type AC of capacity 1.5/2 TR by cleaning condensing coil, cooling unit, blower motor, oiling & greasing of moving parts and testing by soap solution, brush and air blower, tightening nuts, bolts screws and general check-up (Electrical system) of complete unit complete all as specified and directed. |
| 162 | Dismantling the UNSV compressor from 1.5 ton capacity window/ split AC, excluding copper tubing , replace by S&F of same capacity new compressor (replacement basis and also site requirement suitable for invertor type OD unit) with first filling refrigerat gas and fixing on position with nuts, bolts, rubber grommet and washers, connecting copper tubing by welding/ flare nuts complete all as specified and directed. |
| 163 | S&F in replacement starting capacitor 80-100 MFD suitable for 1.5/2.0 ton air conditioner complete all as specified and directed. |
| 164 | S&F in replacement starting relay assembly including coat & cover and clips suitable for AC 1.5/2.0 ton window/ spilt type air conditioner complete all as specified and directed |
| 165 | S&F in replacement blower motor suitable for 1.5 ton window type AC, single phase 230 Volts with replacement of bushes including testing and commissioning complete all as specified and directed. |
| 166 | S&F in replacement air filter pad suitable for any type AC 1.5/2.0 ton capacity complete all as specified and directed. |
| 167 | Carrying out pressure leak test for detecting leak in condensing unit, refrigerant pipe and repairing the leak by welding or brazing of condensing unit and refrigerant pipe, putting under pressure for leak checking after repairs for 72 hours of leak pipe including transporting & carrying out T&P required at site for work of 1.5/2.0 ton capacity any type of AC complete all as specified and directed. |
| 168 | Flushing out by N-2 and CTC, vaccination and supply & charging of refrigerant gas into the system for 1.5 / 2.0 ton capacity any type AC complete all as specified and directed. NOTE: Cost of Strainer & 0.60 size cappliary incuded in the rate |
| 169 | Dismantling of defective cooling indoor unit of 1.5/2 TR capacity split AC complete with connected piping and corded remote control etc & re-fixing on wall/floor after carrying out repairs and servicing and making good the disturbed surfaces as per the existing complete all as specified and directed. |
| 170 | Dismantling of defective condensing unit of 1.5/2 TR capacity split AC complete with connected lead and iron stand etc and re-fixing on roof/floor after necessary repairs and servicing complete all as specified and directed. |
| 171 | S&F in replacement suction copper pipe line heavy ½” dia with foam insulation and flair nuts from indoor to out door unit of split type AC 2.0 TR capacity complete all as specified and directed. |
| 172 | All as per item No. 171 above but discharge copper pipe line heavy duty 3/8” dia. |
| 173 | Dismantling the UNSV defective indoor unit of 1.5 TR capacity split type AC, S&F indoor unit of same capacity of any make with blower motor, front grill and connecting the copper tubing by brazing detecting leak and rectifying the same and installing the same complete all as specified and directed. |
| 174 | Dismantling the UNSV outdoor unit of 1.5 TR capacity split type AC, S&F outdoor unit of same capacity of any make fitted with condensing unit and motor but with compressor and install the same by charging refrigerant gas complete all as specified and directed. |
| 175 | S&F single pole and neutral enclosure with a two pin and earth plug socket 240 volt with one MCB DP ‘C’ series rating 20 to 32 Amp incl taking down the old USNV complete all as specified and directed. |
| 176 | Supply and install hi wall split unit indoor and outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better in door air quailty with minium 5 star and EER 3.2 of capacity 1.5 ton including connecting and testing complete allas specified and as directed by Engr-in-charge. |
| 177 | S&F automatic Voltage stebliser single phase,50 HZ ,230 volts +/- 5% ,90 to 250 rating 4KVA complete for 1.5TR AC all as specified and directed. |
| 178 | S&F Electric water heater storage type(Geysers) of capacity 25 ltrs complete with fitting and fixtures five star rating metal body complete all as specified and directed |
| 179 | Removing the UNSV water purifier from its position and opening the purifier, cleaning the same and replacement of the damage parts like new candle, 3 in 1 cartridge set and assembling the same after testing and fitting complete all as specified and directed. |
| 180 | Check U/S AC cordless remote controlled hand set and supply and replace new hand set as existing make complete all as specified and directed |
| 181 | Supply and replacement heating unit (element) ISI marked of 1500 watts triangular/circuler shape or as per sample required in existing geysers installed at site including rubber washers complete all as specified and directed. |
| 182 | Supply and replacement thermostat range 0°-75°C for the geysers of 25 to 35 litres as per sample required in existing geysers installed at site complete, all as specified and directed. |
| 183 | Supply and replacement PVC threaded tough rubber flexible pipe/tubing of 15 mm size with PTMT nuts at both end 300/450 mm long for geysers inlet/ outlet connections, all as specified. |
| 184 | Supply and replacement LED Indicator lamp rectangular/round type as required at site all as specified and directed. |
| 185 | S&F in replacement motor for water fiiter any make/size as per sample all as specified and directed. |
| 186 | S&F in replacement adopter for water fiiter any make/size as per sample all as specified and directed. |
| 187 | Dismantling of water cooler of 40-80 ltrs storage capacity from its position, taking out water from its water tank cleaning of water tank by washing powder and with fresh water externally and internally and storage tank without disturbing the existing position and connecting the water line including GI fitting when required and PVC pipe connection complete all as specified and directed by the Engr-in-Charge. |
| 188 | Dismantling of UNSV old defective & burnt compressor for 40/80 ltrs capacity of water cooler including disconnecting suction / discharge copper tubing replacing by S&F new compressor and fixing on position with nuts, bolts, rubber gromote and washers, connecting copper tubing by welding / flame nuts, detecting leak and repairs if any, complete all as specified and directed. |
| 189 | Taking out defective gasket of storage water cooler top cover and supply & fixing new rubber gasket of existing size all as specified and directed by Engr-in-Charge. |
| 190 | S & F (in replacement) condensing coil suitable for 40-80 ltrs capacity water cooler of any make all as specified and directed. |
| 191 | Dismantling of defective starting capacitor S&F new capacitor 60 - 80 Mfd complete all as specified and directed. |
| 192 | S&F in replacement capacitor 4 Mfd suitable for blower motor of water cooler complete all as specified and directed. |
| 193 | S&F (in replacement) thermostat suitable for water cooler any capacity all as specified and directed. |
| 194 | S&F (in replacement) push/lift type self closing taps suitable for water cooler all as specified and directed. |
| 195 | S&F (in replacement) PVC float valve assembly with ball suitable for 15 mm bore pipe of water cooler all as specified and directed. |
| 196 | Supply and replacement of compressor including disconnecting suction/ discharge copper tubing of water cooler including taking out old unsv and fixing on position with nuts, bolts, rubber gromote and washers, connecting copper tubing by welding/flame nuts, detecting leak and repairs if any, complete all as specified and directed by Engr-in-Charge |
| 197 | Carrying out pressure leak test by nitrogen pressure for detecting leak in condensing unit, refrigerant pipe and repairing the leakage by welding or brazing of condensing unit refrigerant pipe, putting under pressure for leak checking after repairs of leak pipe including transporting & carrying out T&P required at site for work of water cooler all as specified and directed. |
| 198 | Flushing out by Nitrogen and CTC, vacuum and supply charging of refrigerant gas as existing into the system for water cooler all as specified & directed. |
| 199 | Removing defective condensing fan motor of water cooler single phase 230 V 50 HZ and opening and replacing of Blower motor and cutting out the burnt wiring and cleaning the slots of rotor and rewinding of the same with the existing size of super enamelled copper winding wire including insulation, varnishing, greasing, replacement of bushes, reassembling including testing and commissioning all as directed. |
| 200 | S&F water pump for desert cooler any make and size as per sample all as specified and directed. |
| 201 | S&F selecter switch with knob for desert cooler any make and size as per sample all as specified and directed. |
| 202 | S&F cooling pad (benature/PVC ), (set of 3) for desert cooler any make and size as per sample all as specified and directed. |
| 203 | S&F capacitor 3.5 mfd all as specified and directed. |
| 204 | Supply and fixing desert cooler electric driven (single phase), plastic/PVC body having nominal air flow capacity of 5000 Cum per hour (or nearest size complete all as specified and directed Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 25 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender