Tender For Maint, Repair/Replacement Of Internal Wiring Including Fittings And Fixtures Of Md Accn At Aec Trg College And Centre Pachmarhi
Tender Value
9 Lakhs
Estimated cost
Bid Submission
24 Aug 2026
14 days left
EMD
18000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Hoshangabad → Madhya Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Maint, Repair/Replacement Of Internal Wiring Including Fittings And Fixtures Of Md Accn At Aec Trg College And Centre Pachmarhi
BOQ
| Sl. No. | Item Description |
| 1 | Taking down carefully copper/aluminum point wiring (light/fan/socket power) complete , including fixture and fitting such as switches, ceilling roses, pendants, regulators, socket, light fittings etc. removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfases of walls, floors, etc complete all as specified and directed by Engineer-in-charge. |
| 2 | Taking down existing sub main wiring of any size & type and description including removal of teak wood batten/pipe etc complete. |
| 3 | M&L for One light/fan/bell point controlled by one No piano type switch 5 AMPS single pole one way for point wiring complete with PVC insulated unsheathed FR multistranded copper conductor cable conforming to IS : 694 of size 1.5 Sqmm two single core drawn through in and including PVC concealed conduit pipe 20mm dia medium grade ISI Marked complete with one run of PVC insulated copper conductor cable 1.5 Sq mm single core green colour earth wire and connecting to earth dolly incl colour coding of cable shall be for phase, nuetral and earth wire as specified in MES SSR Part I 1991 with terminal boxes concealed on wall, with modular inner & outer cover for fixing of switches/socket/regulator with screws complete including making good of disturbed surfaces of wall/ceiling/floor in same specification as per existing complete all as specified and directed by Engineer-in-charge. |
| 4 | As per item No 3.00 but One light/fan/bell point controlled by tw0 way switches,with cables 1.5 sqmm size |
| 5 | As per item No 3.00 One socket outlet 5/3 pin 5 AMPS controlled by one switch on the same board. |
| 6 | As per item No 3.00 One socket outlet 5/3 pin 5 AMPS controlled by one switch on independent board. |
| 7 | As per item No 3.00 One socket outlet 15 Amps independent with two single core 2.5 sqmm drawn through in and including PVC concealed conduit pipe 20mm dia medium grade ISI Marked complete with one run of PVC insulated copper conductor cable 1.5 Sq mm single core green colour earth wire and connecting to earth dolly incl colour coding of cable shall be for phase, neutral and earth wire |
| 8 | M&L in replacement of modular white cover plate with frame 2 module complete all as specified and directed by Engineer-in-charge. |
| 9 | M&L in replacement of for modular white cover plate with frame 3 module complete all as specified and directed by Engineer-in-charge. |
| 10 | M&L in replacement of for modular white cover plate with frame 4 module complete all as specified and directed by Engineer-in-charge. |
| 11 | M&L in replacement of modular white cover plate with frame 8 module complete all as specified and directed by Engineer-in-charge. |
| 12 | M&L in replacement of modular metal flush box for 2 module complete all as specified and directed by Engineer-in-charge. |
| 13 | M&L in replacement of modular metal flush box for 3 module complete all as specified and directed by Engineer-in-charge. |
| 14 | M&L in replacement of modular metal flush box for 4 module complete all as specified and directed by Engineer-in-charge. |
| 15 | M&L in replacement of modular metal flush box for 8 module complete all as specified and directed by Engineer-in-charge. |
| 16 | S&F in replacement of Modular switch piano type 6/10 Amps one way single pole 240 volts A.C complete all as specified and directed by Engineer-in-charge. |
| 17 | S&F in replacement of Modular switch piano type 6/10 Amps two way single pole 240 volts A.C complete all as specified and directed by Engineer-in-charge. |
| 18 | S&F in replacement of Modular switch piano type16/ 20 Amps ccomplete all as specified and directed by Engineer-in-charge. |
| 19 | S&F in replacement of Modular socket outlet 5/10 Amps 5 pin 240 Volts multi socket for cell phone pin or 2 pin+ 3 pin complete all as specified and directed by Engineer-in-charge. |
| 20 | S&F in replacement of modular socket outlet 16/20 Amps 6 pin 240 Volts twin socket heavy duty complete all as specified and directed by Engineer-in-charge. |
| 21 | S&F in replacement of modular bell push large piano type single pole one way 240 volts A.C complete all as specified and directed by Engineer-in-charge. |
| 22 | S&F in replacement of bell ding dong/ bell musical single phase 230 volts complete all as specified and directed by Engineer-in-charge. |
| 23 | S&F in replacement of modular type single phase motor stator 240 volt grade up to 25 Amps complete all as specified and directed by Engineer-in-charge. |
| 24 | S&F in replacement of Modular ceiling fan regulator suitable electronic rotary step type 100 Watt 2 module complete all as specified and directed by Engineer-in-charge. |
| 25 | S&F ceiling rose , 3 phase / PVC/ polycarbonate, isolated body ccomplete all as specified and directed by Engineer-in-charge. |
| 26 | S&F LED tube light fitting 1x20 watt LED (4 ft), LED fitting incl LED Tube 20 watt in warm white, 230 volts energy saving, environmental friendly, long life, impact proof, surface mounting , batten suitable for use single LED tube made out from CRCA sheet steel coated for improper resistance against corrosion with PC Housing in opal finish suitable for wet location with brightness LEDs with all accessories internally prewired and incl connected with twin core twisted flexible wire copper conductor cable with suitable size complete all as specified and directed by Engineer-in-charge. |
| 27 | S&F LED Panel 36 watt LED (2X2 ft), LED Recessed mounted aluminium frame fitting ,including LED panel in white , 230 volt energy saving , enviromental friendly , long life, corrosion resistant , impact proof, surface mounting IP-65luminaire with PC Housing in opal finish suitable for wet location with brightness LED edge lit luminaire suitable for armstrong/grid ceiling complete with all accessories internally prewired and including connected with twin core twisted flexible wire copper conductor cable with suitable size complete all as specified and directed by Engineer-in-charge. |
| 28 | S&F in replacement of sheet metal enclousure for MCB DB single pole and neutral 8 way with 200 Amps rated bus bar 240 volts double door type complete all as specified and directed. |
| 29 | M&L for replacment of Sheet metal enclosure MCCB DBs, Triple pole & neutral 4 way with 200 Amp rated bus bar double door suitable for 01 No incoming MCCB of 125Amp capacity and 12 Nos+ 12 Nos Out going MCB SP complete all as specified and directed by Engineer-in-charge.NOTE:- MCCB & MCB's are measured and paid in separate items and same make. |
| 30 | S&F in replacement of MCB SP upto 40 Amps 240 volts complete all as specified and directed by Engineer-in-charge. |
| 31 | S&F in replacement of MCB SPN capacity 40 to 60 Amps DP 240 complete all as specified and directed by Engineer-in-charge. |
| 32 | S&F in replacement of MCCB 4 pole, 125 Amps with breaking capacity 16 KA, 415 volts complete all as specified and directed by Engineer-in-charge. |
| 33 | M&L in replacement of sub main wiring with two single core pvc insulated unsheathed FR copper conductor 1100 volt grade multistandard of size 6 sqmm and incl drawn through and including non metalic rigid pvc conduit and couduit accesssories of 25 mm external dia and conduit accessories of ISI marks medium grade including 4.0 sqmm copper wire for earth continuity wire and connected of common earth dolly. Make of Wire complete all as specified and directed by Engineer-in-charge.Note:- One run of conduit two run of 6 sq mm copper conductor & one run of 4 sq mm copper conductor is measured as one unit. |
| 34 | M&L in replacement of sub main wiring with two single core pvc insulated unsheathed FR copper conductor 1100 volt grade multistandard of size 4 sqmm and incl drawn through and including non metalic rigid pvc conduit and couduit accesssories of 25 mm external dia and conduit accessories of ISI marks medium grade including 4 sqmm copper wire for earth continuity wire and connected of common earth dolly complete all as specified and directed by Engineer-in-charge. Note:- One run of conduit two run of 4 sq mm copper conductor & one run of 4 sq mm copper conductor is measured as one unit. |
| 35 | M&L for Earthing complete with galvanized steel earth plate electrode 600 x600x6mm thick buried directly in ground (earth pit not less than 2.25 meters deep below normal ground level) with top edge of plate not less than 1.6 meter below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts check nuts galvanized iron or steel all as shown in Electrical plate No. 3 of MES sch pt I testing on completion with & incl. 15 mm bore light grade GI protection pipe 7.5 mtr long for earth lead, PCC (1:3:6) pit with pre cast RCC (1:2:4) cover watering arrangement with funnel, wire mesh 20 mm bore light grade GI pipe, common salt & char coal fixing necessary excavation earth work complete all as specified and directed by Engineer-in-charge.Note -GI pipe & GI wire beyond 7.5 mtr will be measured and paid respectively. |
| 36 | Comprehensive maintenance of internal electrification at AEC Training Centre Pachmarhi under jurisdiction of AGE (I) Pachmarhi for attending day to day complaints such as switch, socket, fan regulator, holder, PVC casing & caping, tube lights etc. complete all as specified and directed by Engineer-in-charge.Note- Materials will be measured & paid seprately aganist respectives item of schedule 'A'. |
| 37 | S &F Switch Piano Flush button single pole one way 5 Amp complete all as specified and directed by Engineer-in-charge. |
| 38 | M&L for switch socket comb 2 in 1, 3 Pin 5 Amp flush type ISI Marked complete all as specified and directed by Engineer-in-charge. |
| 39 | M&L Switch socket comination multipurpose 2 in 1,5 and 15 Amp Flush type ISI Marked complete all as specified and directed by Engineer-in-charge. |
| 40 | M&L for Lamp hoder insulated body with back plate for batten fittings complete all as specified and directed by Engineer-in-charge. |
| 41 | M&L for socket outlet 3/5 pin 5Amp flush type complete all as specified and directed by Engineer-in-charge. |
| 42 | S &F Socket type electronic stepped fan regulator flush type on the existing phenolic laminated sheet etc complete all as specified and directed by Engineer-in-charge. |
| 43 | Supply only socket type Electronic fan regulator stepped type 100 watts A.C complete all as specified and directed by Engineer-in-charge. |
| 44 | Supply only switch type Electronic fan regulator stepped type 100 watts A.C complete all as specified and directed by Engineer-in-charge. |
| 45 | Supply only PVC 20 mm casing N caping of 2 mtrs length complete all as specified and directed by Engineer-in-charge. |
| 46 | Supply only Switch Piano Flush button single pole one way 5 Amp complete all as specified and directed by Engineer-in-charge. |
| 47 | Supply only Batten holder angular type 2 pin complete all as specified and directed by Engineer-in-charge. |
| 48 | Supply only Switch socket comination multipurpose 2 in 1,5 and 15 Amp Flush type ISI Marked complete all as specified and directed by Engineer-in-charge. |
| 49 | Supply only Switch socket combination 5 Amps complete all as specified and directed by Engineer-in-charge. |
| 50 | Supply only 5/6 amp 3 pin plug tops complete all as specified and directed by Engineer-in-charge. |
| 51 | Supply only 15/16 amp 3 pin plug tops complete all as specified and directed by Engineer-in-charge. |
| 52 | Supply only Copper conductor standard FR PVC insulated 1.5 Sqmm Single Core Roll of 90 mtr complete all as specified and directed by Engineer-in-charge. |
| 53 | Supply only Copper conductor standard FR PVC insulated 2.5 Sqmm Single Core Roll of 90 mtr complete all as specified and directed by Engineer-in-charge. |
| 54 | Supply only Copper conductor standard FR PVC insulated 4 Sqmm Single Core Roll of 90 mtr complete all as specified and directed by Engineer-in-charge. |
| 55 | Supply only MCB SP 5 to 30 Amps 240 volts complete all as specified and directed by Engineer-in-charge. |
| 56 | Supply only MCB SPN capacity 40 to 60 Amps 240 volts complete all as specified and directed by Engineer-in-charge. |
| 57 | Supply only ceiling Fan condensor 2.5 MFD complete all as specified and directed by Engineer-in-charge. |
| 58 | Supply only ceiling Fan condensor 3.15 MFD complete all as specified and directed by Engineer-in-charge. |
| 59 | Supply Only Nails (Chinese) 1\\" (Type 17),1.5\\",2\\",2.5\\",3\\", Each of 1 Kg complete all as specified and directed by Engineer-in-charge. |
| 60 | Supply only Copper conductor standard FR PVC insulated 6 Sqmm Single Core Roll of 90 mtr complete all as specified and directed by Engineer-in-charge. |
| 61 | Supply only Twin core Flexible wire 23/0076 Roll of 90 mtrs complete all as specified and directed by Engineer-in-charge. |
| 62 | Supply only PVC Tape insulation of width 1.8 cm and 7 Mtrs length complete all as specified and directed by Engineer-in-charge. |
| 63 | Supply onlyHeating elemtny 1.5 kw 230 Volts, ISI Marked suitable for 25 liter capacity geyesrs of any type required complete all as specified and directed by Engineer-in-charge. |
| 64 | Supply onlyHeating elemtny 2.0 kw 230 Volts, ISI Marked suitable for 50 liter capacity geyesrs of any type required complete all as specified and directed by Engineer-in-charge. |
| 65 | Supply only brass chromium plated flexible pipe 15 mm bore heavy duty suitable for hot water supply with two numbers brass chromium plate 450 mm long complete all as specified and directed by Engineer-in-charge. |
| 66 | Supply only Thermostat ISI marked suitable for 25/50 liters geysers as required complete all as specified and directed by Engineer-in-charge. |
| 67 | Supply only LED tube light 20 watt with LED batten complete all as specified and directed by Engineer-in-charge. |
| 68 | M&L in replacement of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 120sqmm 3.5 core complete all as specified and directed by Engineer-in-charge. |
| 69 | M & L for earthing complete with copper earth plate electric 60 cm x 60 cm x 3.15mm buried directly and vertically in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to Copper strip 20 x 3 mm as earth lead by means of bolts, nuts, check nuts and washers of galvanised steel and including necessary earth work execution in any type of latent rock, PCC 1:3:6 type C2 chamber and chamber cover 50mm (PCC 1:2:4) with 8 mm dia CTD reinforcement watering pipe 20mm dia GI, protection pipe for copper strip 40mm dia GI light grade, salt, coal, magnesium sulphate and water funnel etc complete all as per electrical plate No 4 of SSR Part I complete all as spd and directed by Engr-in-Charge . |
| 70 | M&L in replacement of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50sqmm 3.5 core complete all as specified and directed by Engineer-in-charge. |
| 71 | Excavation in trenches n exc 1.5 m wide & n exc 1.5 mtr deep in soft/lose soil for taking out pipe & laying of pipe & getting out for diverting of CI pipe line complete all as specified and directed by Engineer-in-charge. |
| 72 | Returning, filling in, including spreading, leveling, watering & well ramming in layers n. exc 25 cm thick complete all as specified and directed by Engineer-in-charge. |
| 73 | Removal of excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-charge. |
| 74 | M&L for bricks common burnt sub class B designation for protection of cable complete all as specified and directed by Engineer-in-charge. |
| 75 | M&L for natural local river sand for cable protection complete all as specified and directed by Engineer-in-charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 03, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 24, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysAug 31, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender