Tender For Repair And Maintenance Of Perimeter Security Lights And Allied Works Under Ge (A) Jaisalmer
Tender Value
50 Lakhs
Estimated cost
Bid Submission
31 Aug 2026
19 days left
EMD
1 Lakhs
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jaisalmer → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair And Maintenance Of Perimeter Security Lights And Allied Works Under Ge (A) Jaisalmer
BOQ
| Sl. No. | Item Description |
| 1 | Taking down defective/unservicable street light/ flood light/ solar light/post top lantern fitting of any size /type/capacity any Watt from height of pole/walls/high mast of any location up to 16M height for repair work and fixing back after repair work including checking, inspecting, testing and commissioning complete all as specified.Note :- (a) Spares like LED Driver, Surge protector, Service wire etc. shall be measured and paid as separetely under relavant items of schedule'A' (b) Necessary tools like mobile ladder & other T&P required etc shall be arranged by the contractor without any extra cost.(c) The rate quoted deemed to be inclusive for minor repair parts like nuts, bolts, circle clips , clamps etc required if any at site. |
| 2 | Supply only repair of electronic driver for LED light fitting, LED out put power 30 watt, input voltage range : 170 - 300 volt AC , out put voltage DC as per make/model range: 24 volt to 110 volt, make as per site requirement complete all as specified. |
| 3 | All as per item No 2 above but capacity 45 watt |
| 4 | All as per item No2 above but capacity 60 watt |
| 5 | All as per item No 2 above but capacity 70 watt |
| 6 | All as per item No 2 above but capacity 90 watt |
| 7 | Supply only Surge Protector 10KV for street light fitting, Normal voltage input range : 170- 300 volt complete all as specified. |
| 8 | Labour only for making unserviceable street/security lights/solar light serviceable placed at pole by disconnection / Isolating power supply either from pole junction box or by disconnecting overhead jumpers and carrying out de-carbonization / de-sulphation at connection points with overhead conductor / light fitting / junction box terminal including replacement connection wire complete all as specified Note : - Cable shall be measured and paid seprately. |
| 9 | Supply And Fixing in repair LED Street Light Of Capacity 60 Watt, aerodynamically designed for all weather condation with excellent thermal management Having Pressure Die Cast Aluminium Housing,with toughend glassand high power LEDs with secondary optics and IP66 protection.10 KV SPD included , Efficiency Of ≥ 110 Lumens/Watt , The Fitting Must Be Suitable For 30 To 50 Mm O.D Mounting Pipe And Suitable For Mounting On Wall / Pole With Necessary Mounting Arrangements ), Mounting Pipe/Bracket , Nut, Bolts And Accessories Including Disconnected & Taking Down Old Unserviceable Light Complete. The Manufacturer Of The Led Fitting Shall Have Inhouse Nabl Accrediated Lab & Contractor Shall Furnish Same Along With Lm-79,Lm-80, Test Report Etc. all as specified and directed by Engr-in-Charge. Cat No Raptor Pro:- crompton CAT No CRP-409-60-57-SL-GL-NSG or Equivalent in appx c |
| 10 | Supply & Fixing in repair LED Flood Light Fitting 400 Watt Elegently Designed, Pressure Die Cast Aluminium Housing In Powder Coated Finish Ip-66, Lumen Efficacy >= 120lm/W And Total Lumens Output Must Be = 30,000 Lumens Or More, Operating Voltage Range 120 – 270, P.F > 0.95,Cct – 5700k, Surge Protector of 10 Kv Inside Fitting, Driver Of The Fitting Shall Be Potted Type Only For Vibration Proof Performance With Inbuilt Surge Protector, Over Voltage Protection. Both Fixture And Drivre Must Have Separate Bis Marked Registration With Clearly Mentioned On Fixture & As Well As On Driver.Including Disconnected & Taking Down Old Unserviceable Light Complete. The Manufacturer Of The Led Fitting Shall Have Inhouse Nabl Accrediated Lab & Contractor Shall Furnish Same Along With Lm-79,Lm-80, Test Report Etc. Including Making Connection With 3 Core X …….. Frlsh Wire, All As Per Directed By Eic As all as specified and directed by Engr-in-Charge Per Make Crompton/Havells/Wipr,or Equivalent in Appx c |
| 11 | Supply and fixing only in replacement of PVC insulated, sheathed weather proof, copper conductor of size 1.5 sqmm, 3 core complete all as specified. |
| 12 | Supply and fixing only in replacement of PVC insulated, sheathed weather proof, aluminium conductor of size 6 sqmm, 2 core complete all as specified. |
| 13 | M&L in replacement of PVC conduit 20 mm, heavy duty rigid non metallic including of all tee, bends, elbows etc complete all as specified. |
| 14 | S & F in repair Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-31 (9 metres long) and including one coat of red oxide primer and two coat of aluminium paint over a pole including dismantlaing/taking out existing PCC/Steel tubular pole and making surface good complete all as specified and directed by Engr -in-Charge. |
| 15 | M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate in foundation for PCC poles/struts including necessary form work complete all as specified & directed by Engr-in-Charge. |
| 16 | M & L for plain cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate in foundation of PCC pole /stay assembly including necessary form work up to groud level all as specified and directed by Engr-in-Charge. |
| 17 | M&L for plain cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) for pedestal/coping/plinth of poles, including necessary form work finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge. |
| 18 | Supply ,laying, test and commissioning in repair of LT UG ,XLPE insulated, heavy duty, 1100V grade of electric cable size 50 Sqmm 3.5 core with aluminium conductor ,served with an inner sheathing of PVC tape armoured eith galvanized steel wire or tape and overall PVC sheathed,laid in trench or passing through pipe, making all connection with and including provision of necessary glands ,lugs,bushing etc as required complete all as specified and directed by Engineer-in -Charge of following size:-Note: Earthwork excavation sand cushioning ,Jodhpur stone patti, GI protcetion pipe shall be measured and paid separately in their respective items. |
| 19 | (a) All as above item no 18 but size 35 Sqmm 3.5 core |
| 20 | (b )All as above item no 18 but size 25 Sqmm 4 core |
| 21 | (c) All as above item no 18 but size 16 Sqmm 4 core |
| 22 | (d) All as above item no 18 but size 10 Sqmm 4 core |
| 23 | (a) All as above item no 18 but size 10 Sqmm 2 core |
| 24 | Taking out and relaying of old retrieved servicable LT UG cable of any size /any core including pipe or cable cover or DWC pipe complete all as directed by Engr -in- charge. Note : Earth work & other items will be measured and paid separately. |
| 25 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe etc not exceeding 10 sqm on plan and getting out in any type of soil complete all as specified & directed by Engr-in-Charge. |
| 26 | Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in any type of soil all as specified & directed by Engr-in-Charge. |
| 27 | Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as directed by Engr-in-Charge. |
| 28 | M & L in repair HDPE DWC pipe ISI marked fixed on walls,ceiing , in floor,trenches etc for laying of cable protection of the following outer dia :- |
| 29 | a) 40 mm dia |
| 30 | b) 50 mm dia |
| 31 | c) 63 mm dia |
| 32 | S & F in repair of 1.1 KV LT cable route indicator /marker of MS plate 15 CM dia and 10 mm thick and 60 cm long, 45 cm ground in PCC and 15 cm above the ground level of MS angle of 50x 50x6 mm with the logo at the centre\\" LT CABLE GE (A) JSLR \\" complete with PCC as required qty all as specified & directed by Engineer-in-charge. |
| 33 | M&L in repair of Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete including dismantling existing rusted/ unserviceable cross arms. |
| 34 | Supply & fix in repair 40 mm bore GI tubing light grade in trenches or on pole for cable protection complete all as specified and as directed. |
| 35 | Supply & fix in repair 50 mm bore GI tubing light grade in trenches or on pole for cable protection complete all as specified and as directed. |
| 36 | Supply and Fixing in repair of pole mounted junction box of outer size 300x200x120mm made out of FRP body (hot mulded type) with IP-66 protection and locking with screws alongwith 6 Amp rating MCB SP-01 No, up to 50 Amp rated 4 pole connector suitable to insert the cable size up to 25 sqmm x 4 core -02 No and din rail suitable for mounting the MCB/Connector etc complete in side box and duly fixed with 25x3mm FI clamps with nut bolts of suitable size on steel tubular pole/PCC/RCC pole including cable glands, aluminum lugs/thimbles for incoming and out going cables including taking out existing u/s one complete all as specified. |
| 37 | S&F in repair, galvanised iron bracket of 'medium grade' pipe 40 mm bore, length 1.20m, bend to required shape with 2 Set clamps made of 40x6mm FI and suitable size of bolts, nuts & washers, etc duly painted with two coats of aluminium paint over a coat of red oxide primer complete for fixing street light fittings all as directed by Engr-in-Charge. |
| 38 | Supply & fix in repair MCB, single pole, 16-32 Amp, 240 Volts, 'C' Curve 10KA complete all as specifed and directed by Eng-in-Charge. |
| 39 | Supply & fix in repair MCB, SPN, 32 Amp, 240 Volts, 'C' Curve 10KA complete all as specifed and directed by Eng-in-Charge. |
| 40 | Supply and fixing in repair 415V 10KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB/ Panel box/ feeder piller box complete with connection testing and commissioning MCB, TPN 40 Amp, complete all as specifed and directed by Engr-in-Charge. |
| 41 | Supply and fixing in repair 415V 10KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB/ Panel box/ feeder piller box complete with connection testing and commissioning.MCB, TPN 63 Amp, including taking down /dismantling old one Complete all as specifed and directed by Engr-in-Charge. |
| 42 | Material and labour for straight through (Heat Shrinkable) cable jointing kit for 1.1 KV grade cable complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 10/50 SQmm including dismantling the old burnt cable joint termination Complete all as specifed and directed by Eng-in-Charge.. |
| 43 | Material and labour for preparation of old painted surface of LT Concrete electric pole of height 9 mtr in size by removing all dirt, dust,etc and painting complete surface up to pole top including connected accessories with dual coat of apex exterior , synthetic enamel paint over a coat of primer of approved colour of black and white strip 30 cm height 1.5 mtr above the ground level, including painting the cross arms/bracing support on poles with a coat of aluminium paint, silver colour aluminium paint with coating of primer and writing of identification Nos with proper stencil cut etc as per directions by Engr-in-Charge. |
| 44 | Material and labour for preparation of old painted surface of LT Steel tubular pole of 9 mtr in height by removing all dirt, dust,etc and painting complete surface up to pole top including connected accessories with dual coat of apex exterior , synthetic enamel paint over a coat of primer of approved colour of black and white strip 30 cm height (Total 5 Nos) & rest of the height of the pole is in silver colour aluminium paint, including bracing support on poles and writing of identification Nos with proper stencil cut etc as per directions by Engr-in-Charge. |
| 45 | Supply and fix in repair Din type HRC fuse link of Required rating 32A/63A/100A Suitable for HG type 20H/2complete all as specified & directed by Engr-in-Charge.Make:-Seimens/L&T/Havells. |
| 46 | S & F in repair Nature switch( using infrared sensor technology ) based automatic street light control panel. The panel should be enough to take three phase load of 25 KW.Nature switch operation should be based on natural light luxes. required illuminance level switching ON is <=60 and for Switching OFF >=10 lux. the senser should be have a part night operation facility of min 4HRS to max 12 hrs . the senser along with suitable 3 phase load of 25 KW with 3 nos contractor ,3 nos Incoming MCBs of 63 Amps and outgoing MCBs of 63 Amp and circuit wire copper of min 16 Sqmm and should be enclosed in a pole /wall mountig Rust proof ,Electric shock proof ,Termite proof and FR grade thermoplastic polycarbonate enclouser (with hinged lid) conforming to IP66 protection.The circuit should also have provision gor Manual or Auto operation . complete all as specified and directed by Engr-in-Charge. (Make :- Kakatiya Energy system (SW , Indoasian, L&T). |
| 47 | Supply & fix in repair MNX Power contactor suitable for power supply 40 Amps 4 pole 4 NO Contactor including making electrical connection to the contactor complete all as specified & directed by Engr-in-Charge. Make: Legrand or equivalent make of Havells/L&T. |
| 48 | Supply & fix in repair MNX Power contactor suitable for power supply 63 Amps 4 NO Contactor including making electrical connection to the contactor complete all as specified & directed by Engr-in-Charge. Make: Legrand or equivalent make of Havells/L&T. |
| 49 | Suppy &Fix in repair Digital Astronomical timer switch 240V AC-2W,C/O, Base/DIN type complete for switching of contactors complete all as specified and directed by Engineer-in-charge. |
| 50 | M&L for Cutting the road / hard standings and excavating in trenches not exceding 0.40 mtr wide and not exc 0.80 mtr deep across the road for laying cable including making good the excavated portion by means of PCC 1:2:4, type B1 using 20mm graded stone aggregate complete and matching with the surroundings complete all as specified. |
| 51 | Surface Cleaning excavation not exceeding 15 cm deep and getting out in soft/disintigrated rock/any type of soil complete all as specified and directed by Engineer -in- Charge. |
| 52 | M & L for cutting of branches of tree of various length to keep a clear perimeter street light surrounding area and depositioning the cut branches upto 50 mtr from pump house all as specified and directed by Engineer-in-charge. Please Enable Macros to View BoQ information |
| 53 | M & L for cutting of branches of tree of various length to keep a clear perimeter street light surrounding area and depositioning the cut branches upto 50 mtr from pump house all as specified and directed by Engineer-in-charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 03, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 31, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysSep 01, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender