Tender For Repair/Maint Of Ht Overhead Network, Ht Underground Cables, Vcbs, Rums, Gods And Other Connected Works In Old Cantt Under Ge(N) Patiala
Tender Value
52 Lakhs
Estimated cost
Bid Submission
29 Aug 2026
20 days left
EMD
1.03 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Patiala → Punjab
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Maint Of Ht Overhead Network, Ht Underground Cables, Vcbs, Rums, Gods And Other Connected Works In Old Cantt Under Ge(N) Patiala
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation of electric pole, stays,laying of cable, pipe etc and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-charge. |
| 2 | Returning,filling in soft/loose soil including spreading levelling, watering and well ramming in layers not exc. 25 cm thick complete all as specified and as directed by Engineer-in-charge. |
| 3 | Removing the excavated surplus soil to a distance not exc. 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed by Engineer-in-charge. |
| 4 | Supply, laying and spreading fine river sand in trenches,ducts etc, 8 cm before laying of cable and 15 cm after laying of cable for cushioning to under ground cable for protection of cable complete all as specified and as directed by Engineer-in-charge. Note:- Only punned depth shall be measured for payment purpose |
| 5 | Material and labour for un-reinforced precast concrete cable cover class HV, type 1, flat, size 300 mm X 180mm x 40mm laid in trenches over cable perpendicular to the direction of cable abutting each other for protection of cable complete all as specified and as directed by Engineer-in-charge. |
| 6 | Material and labour for cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed by Engineer-in-charge. |
| 7 | Material and labour for cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate for in foundations, filling and mass concretet complete all as specified and as directed by Engineer-in-charge. |
| 8 | Material and labour for cement concrete 1:2:4 type B-1 using 20 mm graded broken stone aggregate as in coping around the poles, strut above ground level, foundation of stay etc. including necessary form work and finishing the concrete surface fair and even without using extra cement complete all as specified and as directed by Engineer-in-charge. |
| 9 | Supply, laying, jointing and testing HT XLPE cable, cross section area 185 Sqmm, 3 core, 11000 V. screened, PVC E grade insulated bedded, galvanised steel (heavy duty) strip or wire armoured with aluminium conductor, pressure earthed system. conforming to IS 7098 (Part-1) 1977 and Part-II of 1985, laid in trenches/ducts through pipes, under floor, roads or fixed to walls/along poles etc including taking out old unserviceable cableant type complete all as specified and as directed by Engineer-in-charge. Note:-Excavation and earth work,sand for cushioning, cement concrete cable cover shall be measured and paid separetaly under respective items of this schedule |
| 10 | Supply, laying, jointing and testing HT XLPE cable, cross section area 120 Sqmm, 3 core, 11000 V. screened, PVC E grade insulated bedded, galvanised steel (heavy duty) strip or wire armoured with aluminium conductor, pressure earthed system. conforming to IS 7098 (Part-1) 1977 and Part-II of 1985, laid in trenches/ducts through pipes, under floor, roads or fixed to walls/along poles etc including taking out old unserviceable cableant type complete all as specified and as directed by Engineer-in-charge. |
| 11 | Supply, laying, jointing and testing HT XLPE cable, cross section area 95 Sqmm, 3 core, 11000 V. screened, PVC E grade insulated bedded, galvanised steel (heavy duty) strip or wire armoured with aluminium conductor, pressure earthed system. conforming to IS 7098 (Part-1) 1977 and Part-II of 1985, laid in trenches/ducts through pipes, under floor, roads or fixed to walls/along poles etc including taking out old unserviceable cableant type complete all as specified and as directed by Engineer-in-charge.Note:-Excavation and earth work,sand for cushioning, cement concrete cable cover shall be measured and paid separetaly under respective items of this schedule |
| 12 | Supply, laying, jointing and testing HT XLPE cable, cross section area 240 Sqmm, 3 core, 11000 V. screened, PVC E grade insulated bedded, galvanised steel (heavy duty) strip or wire armoured with aluminium conductor, pressure earthed system. conforming to IS 7098 (Part-1) 1977 and Part-II of 1985, laid in trenches/ducts through pipes, under floor, roads or fixed to walls/along poles etc including taking out old unserviceable cableant type complete all as specified and as directed by Engineer-in-charge.Note:-Excavation and earth work,sand for cushioning, cement concrete cable cover shall be measured and paid separetaly under respective items of this schedule |
| 13 | Material and labour for mild steel tube, light grade, galvanised, 80 mm bore with all fittings and laid in trenches / under roads/ floors/ fixing along poles and walls with MS clamps made out of 50x 6 mm flat with suitable nuts, bolts & washers complete all as specified and as directed by Engineer-in-charge.Note:-Excavation and earth work shall be measured and paid separetaly under respective items of this schedule |
| 14 | All as per item No 13 here-in-before but mild steel tube, light grade, galvanised,100 mm bore with all fittings complete all as specified and as directed by Engineer-in-charge.Note:-Excavation and earth work shall be measured and paid separetaly under respective items of this schedule |
| 15 | Material and labour for cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 to 95 sqmm complete all as specified and as directed by Engineer-in-charge. |
| 16 | All as per Serial item No. 15 here-in-before but for cable of size 120 to 185 sqmmcomplete all as specified and as directed by Engineer-in-charge. |
| 17 | All as per Serial item No. 15 here-in-before but for cable of size 240 to 300 sqmm complete all as specified and as directed by Engineer-in-charge. |
| 18 | Material and labour for cable jointing kit for 11 KV (earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 to 95 sqmm complete all as specified and as directed by Engineer-in-charge. |
| 19 | All as per Serial item No 18 here-in-before but for cable of size 120 to 185 sqmm complete all as specified and as directed by Engineer-in-charge. |
| 20 | All as per Serial item No 18 here-in-before but for cable of size 240 to 300 sqmm complete all as specified and as directed by Engineer-in-charge. |
| 21 | Supply and fixing Prestressed concrete pole 11.0 metres long. 152mm x 152mm at top and 152mm x 260mm at bottom, class 9 complying with requirement of relevent IS and painting the pole upto 1.5 m height from top of coping in alternate strip of 30cm each with black and red synthetic enamel paint ad writing pole number as directed including excavation around old poles broken pole, demolition of cement concrete in foundation for removing the broken pole from site and making disturbed surface good complete all as specified and as directed by Engineer-in-charge. Note:- Excavation and earth work, cement concrete in foundation and coping etc for new pole shall be measured and paid separetaly under respective items of this schedule. |
| 22 | Material and labour for cable jointing kit for 11 KV (earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 to 95 sqmm complete all as specified and as directed by Engineer-in-charge. |
| 23 | All as per Serial item No 22 here-in-before but for cable of size 120 to 185 sqmm complete all as specified and as directed by Engineer-in-charge. |
| 24 | All as per Serial item No 22 here-in-before but for cable of size 240 to 300 sqmm complete all as specified and as directed by Engineer-in-charge. |
| 25 | Material and labour for replacement of Earthing complete with galvanized earth plate electrode 60 cm x 60cm x 6mm thick buried directly in ground( earth pit not less than than 2.25 metres below ground level with top edge of earth plate or a depth not less than 1.50 m below ground level) connected to Galvanised earth lead wire 4mm dia by means of galvanized iron bolts, nuts, check nuts and washers and necessary excavation and earth work PCC 1:2:4 type B-1 using 20mm graded brick aggregate for earth pit RCC cover, charcoal & common salt filled in alternate layers funnel with 20mm bore light grade watering pipe, 15mm dia GI pipe light grade for projection of earth lead, wire mesh and connected to earth point including testing on all as specified and shown in electric plate No 3 of SSR Part- I 2009 and testing complete all as specified and as directed by Engineer-in-charge. |
| 26 | Material and labour for replacement of Earthing complete with galvanized earth plate electrode 60 cm x 60cm x 6mm thick buried directly in ground( earth pit not less than than 2.25 metres below ground level with top edge of earth plate or a depth not less than 1.50 m below ground level) connected to Galvanised earth lead wire 32 x 6mm dia by means of galvanized iron bolts, nuts, check nuts and washers and necessary excavation and earth work PCC 1:2:4 type B-1 using 20mm graded brick aggregate for earth pit RCC cover, charcoal & common salt filled in alternate layers funnel with 20mm bore light grade watering pipe, 40mm dia GI pipe light grade for projection of earth lead, wire mesh and connected to earth point including testing on all as specified and shown in electric plate No 3 of SSR Part- I 2009 and testing complete all as specified and as directed by Engineer-in-charge. |
| 27 | Material and labour for fixing/ installation, commissioning and testing of switch Air break, Gang operated with 15 insulators switch Triple pole, mechanicaly operated, mounted on insulator and steel frame, for current rating 200 Amp operating Voltage 11 KV out door, vertical mounted type, complete with locking arrengement, assembly with fuse mount carrier and fuse element of required capacity and isolator suitable for 11 KV including necessary electric connection and 11 KV fuse (drop out type) of capacity as required at site and directed by Engr-in-Charge, with DO fuses assembly and one number operating rod of 25 mm dia bore medium grade GI pipe of suitable length, worked out from ground level and handle complete with lock and two Nos keys including flat iron clamp 50mm x 6mm MS channel of suitable size & length for fixing GOD including nut, bolt, washers complete including taking down existing unservicable set complete all as specified and as directed by Engineer-in-charge. |
| 28 | All as per Serial item No. 33 here-in-before but for current rating 400 Amps complete all as specified and as directed by Engineer-in-charge. |
| 29 | Material and labour for replacement of u/s cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of super enamel paint complete all as specified and as directed by Engineer-in-charge. |
| 30 | Dismantling/ taking of HT over head lines 3 wire and 2 earthwire span measured as one length ACSR conductor and Re- stretching of ACSR Conductor 3 wire of any size on HT over head line 11000 volts grade including earth continuity wire including binding properly, replacement of jumper with existing / suitable size of ACSR conductor complete all as specified and as directed by Engineer-in-charge. |
| 31 | Material and labour for painting to existing PCC poles 11 mtr long pole upto 1.5 m height from top of coping in alternate strip of 30 cm each with black and red synthetic enamel paint and marking pole No with synthetic enamel paint of colour and size of letters as approved by Engineer-in-charge complete all as specified and as directed by Engineer-in-charge. |
| 32 | Material and labour for painting of cross arm and MS channel, nut bolts, clamps etc on HT two Pole Structure 11 Mtr long after preparing/ scrapping the metal surface with emery sheet to achieve smooth surface and applying two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed by Engineer-in-charge. |
| 33 | Material and labour for painting of cross arm and MS channel , nut bolts, clamps etc on HT four Pole Structure of 11 Mtr Long after preparing/Scrapping the metal surface with emery sheet to achieve smooth surface and painted with one coat of primer and two coats of aluminium paint.complete all as specified and as directed by Engineer-in-charge. Note for item No 31 to 33 : Bottom of the pole up to 1.5 meter from ground level to be painted with two coats synthetic enamel paint ( every 50cm block ,yellow & black ) & writing the pole & feeder no. and marking with black paint incoming and outgoing cable complete all as specified and as directed by Engineer-in-charge. |
| 34 | Material and labour for Servicing and painting of 11 KV GOD by cleaning the contact ,pin insulator with CTC and applying the Petrolium Jelley at the contact point /down rod links for smooth operation including replacing the rusted/ corroded bolts and nuts (using GI Nuts & Bolts) and deffective insulator of GOD,contacts,tinned strip as required at site.preparation/scrapping of steel or iron surface of cross arm of MS channel and male female contact in red/yellow/ blue color including nut bolts, clamps etc and applying two coats of synthetic enamel paint over a coat of red oxide primer and male female contact in red/yellow/blue colourcomplete all as specified and as directed by Engineer-in-charge.Note:- Unserviceable parts such as contacts, insulators, copper tinned strip etc shall be measured and paid separately as supply only under respective item(s) of this schedule. |
| 35 | Supply only Male/ Moving contact for GOD switch complete all as specified and as directed by Engineer-in-charge. |
| 36 | Supply only Female/ Fixed Contact for GOD switch complete all as specified and as directed by Engineer-in-charge. |
| 37 | Supply only Copper Tinned Strip for GOD switch complete all as specified and as directed by Engineer-in-charge. |
| 38 | Surface excavation not exceeding 30 cm deep and average 15 cm deep and getting out in soft/loose soil including cleaning away all grass, vegetation, shrubs, roots and trees from surrounding of transformers /Poles/ Substation etc, not exceeding 30 cm grith and removing rubbish and levelling the surface complete all as specified and as directed by Engineer-in-charge. |
| 39 | Supply and fixing in repair lightening arrestor Non metal oxide type conform to IS 3070 (part-I) complete with all fittings transmission classes discharge Capacity 65 KA suitable for 11 KV out door typecomplete all as specified and as directed by Engineer-in-charge. |
| 40 | Material and labour for 100 mm thick cement concrete 1:4:8 type D2 using 40mm graded stone aggregate as in sub floors, sub base of floors and paving etc complete all as specified and as directed by Engineer-in-charge. Please Enable Macros to View BoQ information |
| 41 | Material and labour for 100 mm thick cement concrete 1:4:8 type D2 using 40mm graded stone aggregate as in sub floors, sub base of floors and paving etc complete all as specified and as directed by Engineer-in-charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 01, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 29, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysAug 31, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 22 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender