Defence Statutory Bodies & Commissions/Committees Closing in 6 days TDR #56802151

Tender For Sewage And Drain Cleaning And Repair To Sewage Line Manholes & Allied Services To Md Accn Under Age B/R-Ii Of Ge(E) Jrc (Tender Id No 2026_Mes_782134_1)

Issued by Statutory Bodies & Commissions/Committees · Jalandhar, Punjab
Tender Value
30 Lakhs
Estimated cost
Bid Submission
29 Aug 2026
6 days left
EMD
60000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jalandhar → Punjab
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Sewage And Drain Cleaning And Repair To Sewage Line Manholes & Allied Services To Md Accn Under Age B/R-Ii Of Ge(E) Jrc (Tender Id No 2026_Mes_782134_1)

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 12-Aug-2026 Corrigendum No 01 dated 12 Aug 2026 Date 29-Aug-2026

BOQ

Name of Work:- Sewage and drain cleaning and repair to sewage line manholes & allied services to Md Accn under AGE B/R-II of GE(E) JRC (Tender ID No 2026_MES_782134_1)
Sl. No. Item Description
1M&L for Cleaning/Removal of blockage of floor traps/Nahani Traps of 75mm/100mm bore in kitchen/ Bathrooms/Toilets etc up to 1st Manhole including of taking down PVC/Stainless trap grating and refixing the same with white cement with pigment to match the surface as before or any other associated/related complaints not mentioned under this item and will be done as directed by Engr-in-charge. Note :- (a) Contractor/Supervisor shall be taken all complaints from complaint cell within 24 hours. (b) Complaint will be done within 48 hours from the complaint date. (c) If any complaint not done within 48 hours, then Rs. 500/day recovery will be charged against every complaint until complaint done. (e) Measurement can be repeated if blockage is occured more than one time.
2M&L for Cleaning/Removal of blockage of Gully traps up to 1st Manhole of any size and any depth including Removing RCC Manhole covers and refixing the same as before any other associated/related complaints not mentioned under this item and will be done as directed by Engr-in-charge. Note :- (a) Contractor/Supervisor shall be taken all complaints from complaint cell within 24 hours. (b) Complaint will be done within 48 hours from the complaint date. (c) If any complaint not done within 48 hours, then Rs. 500/day recovery will be charged against every complaint until complaint done. (e) Measurement can be repeated if blockage is occured more than one time.
3M&L for Cleaning/Removal of blockage of Orissa/Europian Pattern WC 'P'/S trap and making fuctional up to 1st Manhole and including removing EWC and cleaning the traps completely and making functional and refitting the EWC in same position including making good the disturbed surfaces with white cement and pigment to match the existing surface or any any other associated/related complaints not mentioned under this item and will be done as directed by Engr-in-charge. Note :- (a) Contractor/Supervisor shall be taken all complaints from complaint cell within 24 hours. (b) Complaint will be done within 48 hours from the complaint date. (c) If any complaint not done within 48 hours, then Rs. 500/day recovery will be charged against every complaint until complaint done. (e) Measurement can be repeated if blockage is occured more than one time.
4M&L for Cleaning /Removal of blockage up to 200mm bore SGSW/RCC pipes mechanically with combined high pressure water jetting cum super suction (Vacuum) type machine mounted on LCV/HCV and having facilities of high pressure water jetting, high pressure vacuum and provn of hydraulic application through high pressure thermoplastic fibre based water jetting hose and through conical round shape nozzles pipe and flushing after cleaning/clearing of sewage line including removing RCC Man hole cover and refixing the same as before complete all as directed by Engr-In-Charge. Note:- (a) Contractor/Supervisor shall be taken all complaints from complaint cell within 24 hours. (b) Complaint will be done within 48 hours from the complaint date. (c) If any complaint not done within 48 hours, then Rs. 500/day recovery will be charged against every complaint until complaint done. (e) Measurement can be repeated if blockage is occured more than one time. (f) Length of pipe will be measured from manhole to manhole in RM for payment purpose after satisfaction of Engr-in -Charge.
5Ditto all as per Item no. 4 above, but 300mm dia complete all as specified and as directed.
6Ditto all as per Item no. 4 above, but 450 to 600 mm dia complete all as specified and as directed.
7M&L for Cleaning /Removal of blockage from 150 mm up to 600mm bore SGSW/RCC pipes mechanically with combined high pressure water Jetting machine mounted on LCV/HCV and having facilities of high pressure water jetting, flushing after cleaning/clearing of sewage line including removing RCC Man hole cover and refixing the same as before complete all as directed by Engr-In-Charge. Note:- (a) Contractor/Supervisor shall be taken all complaints from complaint cell within 24 hours. (b) Complaint will be done within 48 hours from the complaint date. (c) If any complaint not done within 48 hours, then Rs. 500/day recovery will be charged against every complaint until complaint done. (e) Measurement can be repeated if blockage is occured more than one time. (f) Length of pipe will be measured from manhole to manhole in RM for payment purpose after satisfaction of Engr-in -Charge.
8M&L for Cleaning/clearing of sewer line from 150mm up to 600 mm bore under ground by removing any type of blockage including desilting, descaling and de-chocking from sewage line using roding/Flexible pipe by any means and flushing after cleaning/clearing of sewage line. The entire sludge water shall be disposed off out of Defence land complete all as directed by Engineer-in-Charge. Note :- (a) Contractor/Supervisor shall be taken all complaints from complaint cell within 24 hours. (b) Complaint will be done within 48 hours from the complaint date. (c) If any complaint not done within 48 hours, then Rs. 500/day recovery will be charged against every complaint until complaint done. (e) Measurement can be repeated if blockage is occured more than one time.
9Cleaning of manholes mechanically by using suction (vaccume) machine including getting out sludge/ waste from manholes and well flushing after cleaning, removing sludge/ waste to low lying area clearing the inlet and outlet pipe mouth, etc (depth of MH n.exc 1.5m) complete all as specified and as directed.Note : (a) Contractor will arrange sewer jetting machine & suction machine/Super Suction Machine having high pressure power to clear sludge from sewage line from 200 to 450 mm dia without any extra cost. (b) No manual work will be allow to clear the septic tank/soakage well and manholes. (c) Measurement will be done from manhole to manhole. (d) Measurement can be repeated if blockage is occured more than one time. (e) Contractor/Supervisor shall be taken all complaints from complaint cell within 24 hours. (f) Complaint will be done within 48 hours from the complaint date. (g) If any complaint not done within 48 hours, then Rs. 500/day recovery will be charged against every complaint until complaint done.
10Ditto all as per Item no 9 above, but depth of MH exc 1.5m and not exc. 3.00 m, complete all as specified and as directed.
11Ditto all as per Item no 9 above,but depth of MH exc 3.00m and not exc. 8.00 m, complete all as specified and as directed.
12M&L for Dewatering/desilting of existing Septic tank/ Soakage Well incl removing of all solid/semi-solid matter of silt residue both organic or inorganic in nature, Using suction pump up to any depth by working under foul condition and disposal of the same in out of MOD area by using trolly mount container, compolete all as directed. by Engr-in-charge.
13Earth work excavation by mechincal means (Hydraulic excavator) means over areas (not exceeding 1.5m in width or 10 sqm on plan), inlcuding dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil as directed, within a lead of 50m complete all as lan and getting out complete all as specified and as directed.
14Ditto all as per Item No. 12.00 above,but depth exc. 1.5m and n. exc. 3.0m, complete all as specified and as directed.
15M&L cement concretre type D2 1:4:8 (40mm graded stone aggregate) as in foundations filling and mass concrete, complete all as specified and as directed.
16Returning, filling in including leveling, watering and well ramming in layers n. exc. 25 cm thick each layer complete all as specified and as directed.
17Removing excavated material (soils) to a distance n. exc. 50m and depositing where directed at a level n.exc. 1.5 m above the starting point complete all as specified and as directed.
18Demolition of brick work built in cement mortar of any description complete all as directed.
19M&L brick work with sub class 'B' bricks, old size, straight or curved on plan exceeding 6 mtr mean radius and built in cement mortar (1:4) complete all as specified and as directed.
20Ditto all as per description of serial item No 19 above, but except bricks complete all as specified.
21Taking down cement plaster of any description including racking out joints for key scrubing with water etc.
22M&L for rendering 15mm thick in CM 1:3 on internal brick or concrete surfaces finished even and smooth without using extra cement with WPC ( WPC shall be measured and paid separetely).
23M&L rendering 15mm thick cement plaster on brick or concrete surfaces in cement mortar (1:4) mixed on surfaces finished fair and even complete all as specified and as directed. (WPC shall be measured and paid separately).
24Supply only liquid water proofing compound (ISI marked), complete all as specified and as directed.
25M&L for two coats of cement base paint on wall over a coat of primer to newly plastered surface including preparation of surface, complete all as specified and as directed.
26Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for , complete all as specified and as directed.
27M&L pre cast RCC 1:2:4 type B1 using 20mm graded stone aggregate as in Manhole cover slab set in CM 1:4 complete all as specified and as directed.
28S&F TMT bars 10mm dia and over cut cut to length bent to shape required including binding with mild steel wire (annealed) not less than 0.9 mm dia, complete all as specified and as directed
29M&L for Providing PCC 1:2:4 type B0 (using 12.50 mm graded crushed stone aggregate) as in coping , benching/haunching , slightly rounded or chamfred angle and throating etc all as directed .
30M&L MS work as small articles for handles, holdfasts, steps, rungs, etc knee piece and similar small article complete all as specified.
31Demolition and breaking up drain pipes of 150mm internal dia of bore SGSW, AC or reinforced concrete pipe set in cement mortar complete all as specified.
32Concrete bed to drain pipes including packing under and haunching against the sides of pipes after the air laid and tested in Cement Concrete 1:3:6 type C2 for bore of pipes 150mm dia, complete all as specified and as directed.
33M&L Reinforced concrete pipes 150 mm bore of pipe, class NP2, laid, jointed and tested with collars complete all as specified and as directed.
34Demolition and breaking up drain pipes of 200mm internal dia of bore SGSW, AC or reinforced concrete pipe set in cement mortar complete all as specified.
35Concrete bed to drain pipes including packing under and haunching against the sides of pipes after the air laid and tested in Cement Concrete 1:3:6 type C2 for bore of pipes 200mm dia, complete all as specified and as directed.
36M&L Reinforced concrete pipes 200 mm bore of pipe, class NP2, laid, jointed and tested with collars complete all as specified and as directed.
37Demolition and breaking up drain pipes of 300mm internal dia of bore SGSW, AC or reinforced concrete pipe set in cement mortar complete all as directed.
38Concrete bed to drain pipes including packing under and haunching against the sides of pipes after the air laid and tested in Cement Concrete 1:3:6 type C2 for bore of pipes 300mm dia, complete all as specified and as directed.
39M&L Reinforced concrete pipes 300 mm bore of pipe, class NP2, laid, jointed and tested with collars complete all as specified and as directed.
40Taking down eaves gutters and rainwater pipes (any size or pattern) including all fittings, heads, shoes, bends, swan necks etc., including cleaning for refixing or removal to store complete all as specified.
41S&F PVC (SWR) pipes110mm bore single socketed in any length with rubber ring joints fixed to walls or trenches or floors, complete all as specified and as directed.
42S&F PVC (SWR) pipes 75 mm bore single socketed in any length with rubber ring joints fixed to walls or trenches or floor,complete all as specified.
43S&F PVC (SWR) bends any radius 110 mm bore, complete all as specified and as directed.
44S&F PVC (SWR) bends any radius 75 mm bore, complete all as specified and as directed.
45S&F PVC (SWR) junction single (Single T) 110mm bore , complete all as specified and as directed.
46S&F PVC (SWR) vent cowl 110mm bore complete all as specified and as directed.
47M&L cutting into existing manholes for connecting 100mm bore new drains by cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete (1:2:4) type B-1 and making good pipe and reforming benching as required finishing even and smooth complete all as specified and as directed.
48M&L for racking out joints/pointing for drains walls with taking out Brick Bat, Pebbles, Silts, Muds, Clay, Sludge, grubbing up bushes etc. from the bottom of Drains and Culvert Bed etc and removing the same to outside the Defence land in any vehicles, complete all as specified and as directed.
49M&L for 100 mm bore, cast iron socket (double) collars, complete all as specified and as directed.
50S&F CI Tikki 100 mm bore including gasket, nut bolts , complete all as specified and as directed.
51M&L for salt glazed stonewere gully traps, square or round mouthed 150 x 150 mm size type 'P' including cast iron cover grating and setting and jointing to drain pipe in Cement Mortar 1:1 complete all as specified and as directed.
52S&F floor trap with grating including jointing to waste pipe in run lead joint fixed in cement concrete type (1:2:4) type B-1 diameter of outlet 75mm, complete all as specified and as directed.
53S&F mild steel CP grating 125mm dia with centre hole all as specified and as directed. by the Engr-in-Charge.
54S& F in repairs Vitreous China wash hand basin, white, flat back, size 550mm x 400mm including brass coupling, mild steel brackets fixed to wall, complete all as specified and as directed.
55S&F vitreous china squatting pan Orissa pattern size 580 x 440mm white with front or back inlet, integral foot rest including CI 'P' or 'S' trap with providing lime concrete bedding and connecting to flushing pipe complete including breaking up existing damaged WC seat and make good to floor complete all as specified and as directed.
56S&F for Vitreous China wash down water closet white with concealed S-Trap/P-trap, 360mm wide, 390mm high and 415 to 445mm long at top including fixing bolt Plastic water closet seat cover white closed pattern with flat bottom and cover and mild steel chromium plated hinging device fixed complete all as specified and as directed.
57Dismantling Floor, Hearth or Wall Tiling including Cement Mortar Bedding (but not backing) and removing rubbish off the premises, complete all as specified and as directed.
58M&L non skid ceramic coloured tiles compound (ISI marked) 7 to 8mm thick (Square or rectangular) area of each tile exc. 0.11 Sqm but not exceeding 0.18 Sqm as in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over and including 15mm thick screed bed or bedding layer in cement mortar (1:6) including neat cement slurry complete all as specified and as directed.
59M&L glazed ceramic coloured tiles compound (ISI marked) of size 450 x 300 x 7mm thick as on vertical surfaces i.e. skirting/ dado set and jointed in neat cement slurry and pointed in white or coloured cement to match the existing surface laid over and including 10mm thick rendering in cement mortar (1:4) to receive tiles complete all as specified and as directed.
60Uprooting of trees, grass, bushes etc from brick wall/roof tiles or any other surfaces of building including dismantling the required brick work/ roof tiles/ mud concrete etc for uprooting the vegetation etc and make good the same to match with existing surface with same material or concrete (1:2:4) type B-1 after pouring the chemical (which destroy the growth of vegetation to the place where vegetation removed). The rate, complete all as specified and as directed.complete all as specified.
61S&F in repairs for precast SFRC manholes covers & frames in circular type (as per IS 12592) Heavy duty for clear opening 300/400mm complete all as specified and as directed.
62Ditto all as per Item No. 61.00 above, but 450/500mm, complete all as specified and as directed.
63Ditto all as per Item No. 61.00 above, but 600/650mm, complete all as specified and as directed..
64Cutting of grass, growth/ vegetations, bushes or like and similar work and making the workable space for carrying out cleaning of sewage line/ manholes in any location or condition all as specified and as directed.. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56802151
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 30 Lakhs
LAST DATE 29-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Sewage And Drain Cleaning And Repair To Sewage Line Manholes & Allied Services To Md Accn Under Age B/R-Ii Of Ge(E) Jrc (Tender Id No 2026_Mes_782134_1)
Basic Detail
Tender No GE/JULL/ET-51/2026-27
Bidding Type Tender
Location
City Jalandhar
State Punjab
Key Dates
Publish Date 12 Aug 2026
Submission Date 29 Aug 2026
Open Date 05 Sep 2026
Finance
Tender Value 30 Lakhs
Tender Fee 500
EMD 60000
Exemption Available
Document List
5588c987-e526-42b2-b504-295f122cc8fd.html
BOQ_876394.xls
Tender51.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 12, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 29, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 6 days
Aug 29, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Sep 05, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 13 days

Tender Documents

Download All (ZIP) ↓
html

5588c987-e526-42b2-b504-295f122cc8fd.html

xls

BOQ_876394.xls

pdf

Tender51.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders