Defence Statutory Bodies & Commissions/Committees Closing in 16 days TDR #56802116

Tender For Repair/Replacement Of Checking Of Earthing, Lightening Arrester Incl Damaged Lightening Conductor, Earthings, Security Lights, Aviation Lights, High Bay Lights, Flood Lights, Hanger Door Motors, Hanger Door Panels Etc And Other Connected M

Issued by Statutory Bodies & Commissions/Committees · Ernakulam, Kerala
Tender Value
35 Lakhs
Estimated cost
Bid Submission
21 Aug 2026
16 days left
EMD
70000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ernakulam → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair/Replacement Of Checking Of Earthing, Lightening Arrester Incl Damaged Lightening Conductor, Earthings, Security Lights, Aviation Lights, High Bay Lights, Flood Lights, Hanger Door Motors, Hanger Door Panels Etc And Other Connected Miscellaneous E/M Works At F, G & H & Other Technical Area At Naval Base Under Ge (Nw) Kochi

BOQ

Name of Work:- REPAIR/REPLACEMENT OF CHECKING OF EARTHING, LIGHTENING ARRESTER INCL DAMAGED LIGHTENING CONDUCTOR, EARTHINGS, SECURITY LIGHTS, AVIATION LIGHTS, HIGH BAY LIGHTS, FLOOD LIGHTS, HANGER DOOR MOTORS, HANGER DOOR PANELS ETC AND OTHER CONNECTED MISCELLANEOUS E/M WORKS AT F, G & H & OTHER TECHNICAL AREA AT NAVAL BASE UNDER GE (NW) KOCHI
Sl. No. Item Description
1M&L for repairs to earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to GI earth strip of size 32 x 6 mm (upto 7.5 metre in length from earth plate) by means of bolts, nuts check nuts & washers of galvanised iron or steel, protected by GI pipe 40 mm bore (light grade) and watering pipe 20 mm bore GI pipe (light grade) and PCC of chamber and coping shall in 1:3:6 type C-1 using 20 mm graded stone aggregate including excavation and earth work and removal of surplus soil and filling with black cotton soil upto ground level complete all as shown in electrical plate No 3 of SSR Pt-I, 2009 with CI cover 10mm thick of size 300x300mm with charcoal dust and common salt complete and earth lead connected to panel including testing complete all as specified and directed. Note : Earth test result shall be less than one ohm and test result to be submitted to Engineer-in-Charge.
2M & L in repairs to earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanized iron strip 25x4 mm dia as earth up to 7.5 m distance and connected by means of bolts, nuts, checknuts and washers of galvanised iron or steel all shown in electric plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including provision of necessary excavation and earth work in any type of soil, PCC pit , RCC cover 50 mm thick, reinforced with 8 mm dia TMT bars both ways @ 10 CM c/c , 20 mm bore medium grade watering pipe, water funnel, 40 mm bore GI medium grade protection pipe, common salt, charcoal dust, returning, filling in of soil, removal of spoil to a distance not exceeding 50 mtr etc including testing on completion complete all as specified and directed by Engineer-in-Charge.Note :- (i) The unit rate includes for protection pipe and earth lead upto 7.50 Mtr. (ii) Earth lead beyond 7.50 Mtr length shall be measured and paid separately.
3M&L for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanized iron wire 4mm dia as earth up to 7.5 m distance and connected by means of bolts, nuts, checknuts and washers of galvanised iron or steel all shown in electric plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including provision of necessary excavation and earth work in any type of soil, PCC pit , RCC cover 50 mm thick, reinforced with 8 mm dia TMT bars both ways @ 10 CM c/c, 20 mm bore medium grade watering pipe, water funnel, 25 mm bore GI light grade protection pipe, common salt, charcoal dust, returning, filling in of soil, removal of spoil to a distance not exceeding 50 mtr etc including testing on completion complete all as specified and as directed by Engineer-in-Charge. Note :- (i) The unit rate includes for protection pipe and earth lead upto 7.50 Mtr. (ii) Earth lead beyond 7.50 Mtr length shall be measured and paid separately.
4Equipment and labour for testing of earth resistance of existing earthing of lightening arrestor of building /workshop/hanger /OTM etc at F, G & H area and certain technical area at whole Garuda area complete all as specified and directed by Engineer-in-Charge.
5S&F in repair test terminal box of size 175x120x 80mm made out of 2mm thick hot dip galvanised sheet drilled and screwed including 4 nos 125mm long hexogonal head screwed with test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and as directed.
6S F in repair air termination, single pointed aluminium rod 12mm dia and 300 mm long, with DNB insulators. complete all as specified and directed.
7S&F in repair aluminium strip 25x3.15 mm with saddles, including DNB insulator and fixing screws & washers etc., for roof conductors and down condutors, complete all as specified and directed.
8S&F in repair GI strip of size 32x6mm for lightning conductor laid in trench / floor including necessery clamps, nuts, bolts, DNB insulators and hylem sheet block complete all as specified and as directed.
9S&F in repair GI pipe, light grade 40 mm dia as protection for lightening strips on walls with necessary clamps etc complete all as specified and as directed.
10S&F in repair Energy saving, environment friendly & robust Mediumbay /Highbay LED luminaire 150 Watt, 240 Volts with high efficacy (100lm/W) with toughened glass complete all as specified and as directed.
11S&F in repair LED Flood light 70 Watt, 120 lumen/watt, 50 Hz, 220 Volts having IP-66 Protection, pressure die cast aluminium housing, high luminious efficiancy and high power complete all as specified and as directed by Engineer-in-Charge.
12S&F in repair LED Flood light 100 Watt, 120 lumen/watt, 50 Hz, 220 Volts having IP-66 Protection, pressure die cast aluminium housing, high luminious efficiancy and high power complete all as specified and as directed by Engineer-in-Charge.
13S&F in repair LED Flood light 150 Watt, 140 lumen/watt, 50 Hz, 220 Volts having IP-66 Protection, pressure die cast aluminium housing, high luminious efficiency and high power complete all as specified and as directed by Engineer-in-Charge.
14S&F in repair LED building security light fitting 35 Watt, 230 V, AC outdoor type, 120 lum/watt with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed by Engineer-in-Charge.
15S&F in repair LED building security light fitting 60 Watt, 230 V, AC outdoor type, 120 lum/watt with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed by Engineer-in-Charge.
16S&F in repair LED aviation obstruction light luminaires 10W, IP-65 rating (dust/waterproof), 50 Hz, nominal voltage 240 Volt, Operating input voltage range between 100 to 270 VAC comprising of die-cast aluminum housing with red polycarbonate dome with supper flux 5mm LEDs with intergral drivers complete all as specified and as directed by Engineer-in-Charge. Please Enable Macros to View BoQ information
17S&F in repair LED aviation obstruction light luminaires 10W, IP-65 rating (dust/waterproof), 50 Hz, nominal voltage 240 Volt, Operating input voltage range between 100 to 270 VAC comprising of die-cast aluminum housing with red polycarbonate dome with supper flux 5mm LEDs with intergral drivers complete all as specified and as directed by Engineer-in-Charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56802116
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 35 Lakhs
LAST DATE 21-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Replacement Of Checking Of Earthing, Lightening Arrester Incl Damaged Lightening Conductor, Earthings, Security Lights, Aviation Lights, High Bay Lights, Flood Lights, Hanger Door Motors, Hanger Door Panels Etc And Other Connected Miscellaneous E/M Works At F, G & H & Other Technical Area At Naval Base Under Ge (Nw) Kochi
Basic Detail
Tender No 8626_GE_NW
Bidding Type Tender
Location
City Ernakulam
State Kerala
Key Dates
Publish Date 01 Aug 2026
Submission Date 21 Aug 2026
Open Date 28 Aug 2026
Finance
Tender Value 35 Lakhs
Tender Fee 500
EMD 70000
Exemption Not Available
Document List
94537af7-a9a3-4feb-946d-bb0f86a2a94f.html
BOQ_876434.xls
PS8626.pdf
Tender8626.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 01, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days
Aug 28, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 23 days

Tender Documents

Download All (ZIP) ↓
html

94537af7-a9a3-4feb-946d-bb0f86a2a94f.html

xls

BOQ_876434.xls

pdf

PS8626.pdf

pdf

Tender8626.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders