Agriculture Government Departments Closing in 3 days TDR #56802076

Tender For Renovation And Modernization Of One Room With Attached Bathroom Facility And Co-Working Spaces At The 1St Floor Of The Administrative Building Of West Bengal Co-Operative Milk Producers Federation Limited , Lb-2 , Salt Lake , Kolkata-70010

Issued by Government Departments · 24 Paraganas North, West Bengal
Tender Value
10.18 Lakhs
Estimated cost
Bid Submission
18 Aug 2026
3 days left
EMD
20367
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
24 Paraganas North → West Bengal
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Renovation And Modernization Of One Room With Attached Bathroom Facility And Co-Working Spaces At The 1St Floor Of The Administrative Building Of West Bengal Co-Operative Milk Producers Federation Limited , Lb-2 , Salt Lake , Kolkata-700106

BOQ

Name of Work:- Renovation and Modernization of one Room with attached bathroom facility and co-working spaces at the 1st floor of the Administrative Building of West Bengal Co-Operative Milk Producers Federation Limited , LB-2 , Salt lake , Kolkata-700106
Sl. No. Item Description
1CIVIL REPAIRING Works
2Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m.
3Taking out Mirzapur or glazed porcelain tiles carefully bychiselling from walls or floor including stacking serviceable material as directed.
4Taking out heavy iron grated door or window (jail pattern or existing) with locking arrangement after cutting out from walls and refixing the same including mending all damages.[Mending charges to be paid separately]
5Brick work with 1st class bricks in cement mortar (1:6)(b) In superstructure, ground floor
6125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.
7Labour for Chipping of concrete surface before taking up Plastering work.
8Supplying and laying true to line and level Double Charge Vitrified Tiles of approved brand conforming to IS 15622: 2006 (Group B I a) and tested as per IS 13630:2006 (relevant parts) [Non-modular sizes for tiles with Water Absorption (av.) ≤ 0.08 %] in floor, skirting etc. using polymerised adhesive of 6mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course and joints grouted with admixture of white epoxy grout materials of approved brand including spacer -2mm as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials,Iabour and all other incidental charges complete as per direction of Engineerin-Charge. (Note: This work should not be executed without specific permission of Superintending Engineer) (a) ln Ground FIoor:(size not Iess than 600mmX 600 mm X 9.5 mm thick)
9Supplying,fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charges for fitting & fixing of aluminium 2-track/3-track sliding window with fixing of glass (excluding cost of glass) all complete as per architectural drawings and direction of Engineer-in-charge. 10-12 Micron thickness Annodizing film Natural white
10Supplying, fitting & fixing of partly glazed partly panelled or fully glazed single leaf Aluminium swing door of all aluminium sections viz door frame ( top and side frame), shutter( top rail, bottom rail, lock rail, door vertical) ,glazing clip made of Aluminium Alloy Extrusions conforming to IS: 733-1983 and IS: 1285-1975, annodized conforming to IS:1868- 1983, fitted with all other accessories viz. EPDM gusket,cleat, angle screws etc. including labour charges for fitting and fixing of aluminium door with door spring,/aluminium hinges, glass / Panel board all complete as per architectural drawings and direction of Engineer-incharge. ( Excluding cost of glass/ panel board, door spring/ Al hinges, door closer, door stoper, handle, tower bolt and locking arrangment etc) 10-12 Micron thickness Annodizing film Natural white
11Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987iv) 5mm thick coloured / tinted / smoke glass.
12Providing and fixing exterior quality Aluminium Composite Panel (ACP) wall cladding on existing Al. /MS frame work with GI brackets, ACP fixed on the existing frame work by folding the edges of ACP panel (Engraving the rear surface of ACP sheet) with CP angles, cleats and strainless Steel screws forming groves at the periphery of ACP panel. Such grooves filled with foam and silicon sealant etc. complete with all materials (but including the cost of silicon sealant), labour, scaffolding and all other incidental charges complete in all respect as per specification and direction of Engineer-in-charge. (Mode of payment is on finished surface area of ACP)(a) 3mm thick (0.25mm Al.+2.5mm LDPE +0.25mm Al. PVDF coating)
13Supplying, fitting and fixing fibre reinforced polymer (FRP) Composite door frame as per approved section with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to safisfy IS: 4020 door testing performance criteria.(i) 66mm x 90mm
14Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) tosatisfy IS:4020 door testing performance criteria.In ground floor.(i) 32 mm thick
15Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately)(b) 40mm X 6mm, 200mm Length
16Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark.(iv) 75mm. X 47mm. X 1.70mm
17ii) Brass hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting. (a) 300mm long
18Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixedwith cadmium plated screws:(iii) 100mm long x 10mm dia. Bolt
19ii) Godrej Hydraulic door closer fitted and fixed complete(b) Medium type
20Anodised aluminium grip handle with base plate of approved quality fitted and fixed complete.(iii) 300mm grip x 20mm dia rod x 50mm plate x 3.2mm thick.
21Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(A) Floor With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (a) Area of each tile upto 0.09 Sq.m (i) Coloured decorative
22(B) Wall With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (a) Area of each tile upto 0.09 Sq.m (i) Coloured decorative
23Supplying, fitting & fixing of Aluminium fixed partion wall of allaluminium sections viz top, bottom and side member, intermediate member, glazing clip made of Aluminium Alloy Extrusions conforming to IS: 733-1983 and IS: 1285-1975, annodized conforming to IS:1868- 1983, fitted with all other accessories viz. EPDM gusket,cleat, anglescrews etc. including labour charges for fitting and fixing of aluminium fixed partition wall with glass / panel board all complete as per architectural drawings and direction of Engineer-in-charge. (Excluding cost of glass/ panel board, 10-12 Micron thickness Annodizing film.Natural white.
24Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint.(ii) 550 mm X 400 mm size
25Supplying, fitting and fixing bevelled edged mirror 5.5 mm thick silver red as per I.S. 3438 / 1965 together with brass C.P. hinges.(ii) 600 mm X 450 mm
26(c) (i) Chromium plated Bib Cock (angular shape with wall flange) (Equivalent to Code No. 5037 & Model - Florentine of Jaquar or similar brand).
27Supplying, fitting and fixing towel rail with two brackets(b) Aluminium(iii) 25 mm dia. and 750 mm long
28Supplying, fitting and fixing liquid soap container(a) Cromium plated.
29Supplying, fitting and fixing porcelain soap tray of approved make.(i) Recessed soap tray of size 150 mm X 150 mm
30Supplying, fitting and fixing E.W.C. in white glazed vitreous chinaware of approved make complete in position with necessary bolts, nuts etc.(a) With 'P' trap
31Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc.
32(f) Hand Shower(Health Faucet) with 1mtr Fexible Tube with WallHook(Equivalent to Code No.573 & Model -ALLIED of Jaquar orsimilar).
33Chromium plated Rose shower with revolving joint and 150 mm long shower arm (Equivalent to Code No. 5489 & Model - Florentine of Jaquaror similar brand).
34CP 2-way bib Cock - 15 mm, supplied, fitted and fixed. (Code No.5041 & Model - FLORENTINE of JAQUAR or similar brand).
35Supplying, fitting and fixing bib cock or stop cock.(ii) Chromium plated Bib Cock long body with wall flange with aerator (Equivalent to Code No. 512 & Model - Tropical / Sumthing Special ofESSCO or similar brand)
36(Q) Ball Valve40 mm
37Supplying, fitting and fixing pillar cock of approved make. a) (i) CP Pillar Cock - 15 mm. (Equivalent to Code No. 507 & Model - Tropical / Sumthing Special of ESSCO or similar brand).
38Supplying,fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia.(ii) 450 mm long
39Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992(A) (i) Single Socketed 3 Meter Length (ii) 110 mm. Dia
40(ii) 75 mm. Dia
41c) Bend 87.5 degree (ii) 110 mm. Dia.
42Supplying, fitting and fixing CPVC (ChlorinatedPolyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. 20 mm
43Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.
44(i) Pakur Variety.
45Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)
46(a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge.
47Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. II.JSW/JSPL/SHYAM/ SRMB/BMASL/ELECROSTEEL/SSL
48(a) For works in foundation, basement and upto roof of ground floor/upto 4 m
49(i) Tor steel/ Mild steelIII. OTHER MANUFACTURERS NOT SPECIFIED
50Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary. (Ground floor).[Excluding cost of chipping over concrete surface]
51(ii) With 1:4 cement mortar.
52(b) 15 mm thick plaster
53(a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc
54(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :With other than hi-gloss of approved quality-(iv) Two coats (with any shade except white)
55Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor) (a) One Coat i) Water based interior grade Acrylic Primer
56Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) :(Two coats) ii) Luxury Quality
57a) Normal Acrylic Emulsion
58FURNITURE Related Works
59Office section table with drawer
60Covered rack for file
61Executive table
62Executive chair
63ELECTRICAL REPAIRING WORKS
64Supplying and fixing double-door SPN MCB Distribution Board Legrand make2+12 way with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.Incl 40A DP Isolator Same make.and 12 no 6-32A same make MCB as outgoing MAKE:LEGRAND(607711)/SIMENNS
65Supply & Fixing 240 V, 2 nos. 6A, & 2 nos. 20A plug socket with separate 2 nos. 6 A & 2 nos. 20A modular key type switch, indicator & 20A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
66Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [only PVC Rigid Conduit on ceiling and remaining portion concealed]
67Avg Run 10 Mtr
68Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required
693 x 22/0.3 (1.5 sqmm)
702 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm)(for 25 nos power plugs) for SPN DB to Power Plugs
712x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC
72Supply & Fixing 240 V, 25A Modular type socket, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (C-Curve) and 6 Module GI Modular type switch board with 6 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
73Supply & Fixing 240 V,6/16 A, 5 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wireetc.
74Supply & Fixing 240 V, 6 A, 3 pin Modular type plug socket (Brand approved by EIC) with 6A Modular type switch, without plug top on 4 Module GI Modular type switch board with 3 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuitywire etc.
75S&F 230V,50 HZ AC 48'' sweep (Crompton/Havells/ Orient) Ceiling Fan inclu. All accassories viz, Canopy/Fork/ down rod etc.incl,connection as per Gs.
76Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc.
77Supply and fixing 20 W LED tube light fittings(T 8 Crompton make) LT8-20-865-2 Incl supply and fixing Batten and Fixing only fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports incl. S&F EI conduit, ball socket/socket type ceiling plate and connecting the length of PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm) flexible copper wire of 1.10 mt. length MAKE:CROMPTON/PHIIPS
78S&F 230V,50 HZ AC (9'') Sweep Exhaust Fanm(Havells/EPC/ORIENT) after making hole in wall and making good damages & smooth cement finish etc .inclu. S&F leuvour Shutter/Cowl on wall with necessary bolts,nuts (6 mm x 62 mm long) and Providing necessary length of PVC insulated wire and making connection as per Gs.
79Installation,Testig and Commissioning of above AC machines
80Supply of Mitsubishi Heavy Duty Hyper Inverter AC SRK20YYM-W6 1.80 Ton 3 Star - Chilling Mart
81Taxes & Duties
82Add: G.S.T. @ 18% of Rs.8,54443=63, ( sum of Sl. No. 1.01 to 3.17) i.e. Rs.1,53,799=85
83Add: Labour Cess @ 1% of Rs. 10,08,243=48 (sum of Sl. No. 1.01 to 4.01) i.e. Rs. 10,082=43 Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56802076
AUTHORITY Government Departments
TENDER VALUE 10.18 Lakhs
LAST DATE 18-08-2026
Authority
Authority Name Animal Resources Development Department
Work Description Tender for Renovation And Modernization Of One Room With Attached Bathroom Facility And Co-Working Spaces At The 1St Floor Of The Administrative Building Of West Bengal Co-Operative Milk Producers Federation Limited , Lb-2 , Salt Lake , Kolkata-700106
Basic Detail
Tender No PBGSBS/ENGG-BEN/NIT-294/26-27
Bidding Type Tender
Location
City 24 Paraganas North
State West Bengal
Key Dates
Publish Date 03 Aug 2026
Submission Date 18 Aug 2026
Open Date 20 Aug 2026
Finance
Tender Value 10.18 Lakhs
Tender Fee Ref. Documents
EMD 20367
Exemption Available
Document List
7f22b247-9a6c-4b9b-bd0b-8e5295cbb4e1.html
BOQ_2544224.xls
Tendernotice_1 (16).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 18, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Aug 20, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
html

7f22b247-9a6c-4b9b-bd0b-8e5295cbb4e1.html

xls

BOQ_2544224.xls

pdf

Tendernotice_1 (16).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender