Tender For Dismantling Of Four Existing Ht Feeder And Re-Erection Of 4 Ht Feeders Namely Feeder - 2 (3.3Kv), Feeder - 5 (6.6Kv), Feeder - 7 (6.6Kv) And Feeder - 8 (3.3Kv) From Kantapahari Sub Station To Kantapahari Patch Purposed Pumping Station (For
Tender Overview
Project Description
Tender for Dismantling Of Four Existing Ht Feeder And Re-Erection Of 4 Ht Feeders Namely Feeder - 2 (3.3Kv), Feeder - 5 (6.6Kv), Feeder - 7 (6.6Kv) And Feeder - 8 (3.3Kv) From Kantapahari Sub Station To Kantapahari Patch Purposed Pumping Station (For Kumarijore) At Akwmc Ocp Katras Area
BOQ
| Sl. No. | Item Description |
| 1 | ITEM DESCRIPTION / HEADLING |
| 2 | (A) FEEDER 2 Supply of MS Tubular pole -12 mtr |
| 3 | Erection of Metallic Pole upto 12 meter length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal) Foundation including excavation and refillingetc as required |
| 4 | Supply and erection of 11KV pin insulator complete with large steel head GI Pin, nut washer etc as required |
| 5 | Supply and erection of 11KV disc insulator for 11kv overhead line with galvanised insulator fitting, ball and socket type and complete with galvanised strain clamps, bolt, nut, washer etcas required |
| 6 | Supply and erection of GI Wire 8 SWG |
| 7 | Erection of GI wire 8 No SWG including Binding |
| 8 | Supply of AB Switch Nominal Voltage 11KV Grade, Rated voltage 12KV, 1240Amps 3 Phase outdoor Type off load disconnection in horizontal plane with earthing switch. |
| 9 | Erection of AB Switch Nominal Voltage 11KV Grade, Rated voltage 12KV, 1240Amps 3 Phase outdoor Type off load disconnection in horizontal plane with earthing switch. |
| 10 | Supplying of channel iron 75mmx 40mm x 6mm (7.14 kg per meter ) V Shape cross arm for two 11KV overhead line conductor complete with 50mm x 6mm M.S. Flat iron clamps, bolts, nuts, and washers etc (as per drawing) and painting with primer and finish paint as required. |
| 11 | Supply of two length of channel iron 75mm x 40mm x 6mm) (7.14kg per meter) double pole cross arm for three wire 11KV overhead line conductor complete with trough bolts and nuts for clamping to the poles, 50mm x 6mm MS Flat weelded on one side to the channel iron and with bolts and nuts. |
| 12 | Supplying of channel iron 75mmx 40mm x 6mm (7.14 kg per meter ) pole top bracket/ cross arm for single 11KV Overhead line conductor complete with 50mm x 6mm flat iron clamp, bolt nut and washer including drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required. |
| 13 | Supply of 50mm x 8mm MS Flat iron pole top bracket/ cross arm for single 11/22/33kv overhead line conductor complete with fixing clamp bolts, nuts, and washer drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required. |
| 14 | Erection of pole top/ straight two wire/ V Shape two wire, angle iron/ channel iron, cross arm on steel tubular/ rail / PCC Pole for 11k/22/33KV as required. |
| 15 | Erection of double pole 3 wire cross armfor 11KV/22KV/33KV overhead line as required. |
| 16 | Providing and fixing of HT Danger notice Plate of 250mm x 200mm, made of mild steel at least 2mm thick and vitreous enameled white on both sides and with incription in single red colour on front side as required. |
| 17 | Supply of ACSR Dog Conductor (3260mtrs x 3 = 9270 mtrs ) + (10% Additional for sag) = 10,758 mtrs |
| 18 | Erection of ACSR Dog Conductor including binding as required = 0.394kg/mtr x 10,758 mtrs = 4238.65Kg |
| 19 | Supply and erection of Galvanised stay set for 11KV overhead line complete with 19/20 mm Dia x 1.8 mtrs long stay rod, anchor plate set size 45cm x 45 cm x 7.5mm thick, thimble, stay clamp, turn buckel (20mm x 600mm), 7/4.0 mm dia GI Stay wire and 11kv strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse and : 6 graded stone aggregate 40mm nominal size) foundation including excavation and refilling etc as required. |
| 20 | Supply and fitting of cradle guard |
| 21 | Dismantling of Dog conductor 760mtrs |
| 22 | Dismantling of disc insulator 36nos |
| 23 | Dismantling of pin insulator 27nos |
| 24 | Dismantling of Iron materials |
| 25 | Dismantling of pole |
| 26 | Transportation of Dismantled Pole |
| 27 | (B) FEEDER 5 Supply of MS Tubular pole -12 mtr |
| 28 | Erection of Metallic Pole upto 12 meter length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal) Foundation including excavation and refillingetc as required |
| 29 | Supply and erection of 11KV pin insulator complete with large steel head GI Pin, nut washer etc as required |
| 30 | Supply and erection of 11KV disc insulator for 11kv overhead line with galvanised insulator fitting, ball and socket type and complete with galvanised strain clamps, bolt, nut, washer etcas required |
| 31 | Supply and erection of GI Wire 8 SWG |
| 32 | Erection of GI wire 8 No SWG including Binding |
| 33 | Supply of AB Switch Nominal Voltage 11KV Grade, Rated voltage 12KV, 1240Amps 3 Phase outdoor Type off load disconnection in horizontal plane with earthing switch. |
| 34 | Erection of AB Switch Nominal Voltage 11KV Grade, Rated voltage 12KV, 1240Amps 3 Phase outdoor Type off load disconnection in horizontal plane with earthing switch. |
| 35 | Supplying of channel iron 75mmx 40mm x 6mm (7.14 kg per meter ) V Shape cross arm for two 11KV overhead line conductor complete with 50mm x 6mm M.S. Flat iron clamps, bolts, nuts, and washers etc (as per drawing) and painting with primer and finish paint as required. |
| 36 | Supply of two length of channel iron 75mm x 40mm x 6mm) (7.14kg per meter) double pole cross arm for three wire 11KV overhead line conductor complete with trough bolts and nuts for clamping to the poles, 50mm x 6mm MS Flat weelded on one side to the channel iron and with bolts and nuts. |
| 37 | Supplying of channel iron 75mmx 40mm x 6mm (7.14 kg per meter ) pole top bracket/ cross arm for single 11KV Overhead line conductor complete with 50mm x 6mm flat iron clamp, bolt nut and washer including drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required. |
| 38 | Supply of 50mm x 8mm MS Flat iron pole top bracket/ cross arm for single 11/22/33kv overhead line conductor complete with fixing clamp bolts, nuts, and washer drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required. |
| 39 | Erection of pole top/ straight two wire/ V Shape two wire, angle iron/ channel iron, cross arm on steel tubular/ rail / PCC Pole for 11k/22/33KV as required. |
| 40 | Erection of double pole 3 wire cross armfor 11KV/22KV/33KV overhead line as required. |
| 41 | Providing and fixing of HT Danger notice Plate of 250mm x 200mm, made of mild steel at least 2mm thick and vitreous enameled white on both sides and with incription in single red colour on front side as required. |
| 42 | Supply of ACSR Dog Conductor (3260mtrs x 3 = 10080 mtrs ) + (10% Additional for sag) = 11,088 mtrs |
| 43 | Erection of ACSR Dog Conductor including binding as required = 0.394kg/mtr x 11,088 mtrs = 4368.67Kg |
| 44 | Supply and erection of Galvanised stay set for 11KV overhead line complete with 19/20 mm Dia x 1.8 mtrs long stay rod, anchor plate set size 45cm x 45 cm x 7.5mm thick, thimble, stay clamp, turn buckel (20mm x 600mm), 7/4.0 mm dia GI Stay wire and 11kv strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse and : 6 graded stone aggregate 40mm nominal size) foundation including excavation and refilling etc as required. |
| 45 | Supply and fitting of cradle guard |
| 46 | Dismantling of Dog conductor 2160mtrs |
| 47 | Dismantling of disc insulator 36nos |
| 48 | Dismantling of pin insulator 27nos |
| 49 | Dismantling of Iron materials |
| 50 | Dismantling of pole |
| 51 | Transportation of Dismantled Pole |
| 52 | © FEEDER - 7 Supply of MS Tubular pole -12 mtr |
| 53 | Erection of Metallic Pole upto 12 meter length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal) Foundation including excavation and refillingetc as required |
| 54 | Supply and erection of 11KV pin insulator complete with large steel head GI Pin, nut washer etc as required |
| 55 | Supply and erection of 11KV disc insulator for 11kv overhead line with galvanised insulator fitting, ball and socket type and complete with galvanised strain clamps, bolt, nut, washer etcas required |
| 56 | Supply and erection of GI Wire 8 SWG |
| 57 | Erection of GI wire 8 No SWG including Binding |
| 58 | Supply of AB Switch Nominal Voltage 11KV Grade, Rated voltage 12KV, 1240Amps 3 Phase outdoor Type off load disconnection in horizontal plane with earthing switch. |
| 59 | Erection of AB Switch Nominal Voltage 11KV Grade, Rated voltage 12KV, 1240Amps 3 Phase outdoor Type off load disconnection in horizontal plane with earthing switch. |
| 60 | Supplying of channel iron 75mmx 40mm x 6mm (7.14 kg per meter ) V Shape cross arm for two 11KV overhead line conductor complete with 50mm x 6mm M.S. Flat iron clamps, bolts, nuts, and washers etc (as per drawing) and painting with primer and finish paint as required. |
| 61 | Supply of two length of channel iron 75mm x 40mm x 6mm) (7.14kg per meter) double pole cross arm for three wire 11KV overhead line conductor complete with trough bolts and nuts for clamping to the poles, 50mm x 6mm MS Flat weelded on one side to the channel iron and with bolts and nuts. |
| 62 | Supplying of channel iron 75mmx 40mm x 6mm (7.14 kg per meter ) pole top bracket/ cross arm for single 11KV Overhead line conductor complete with 50mm x 6mm flat iron clamp, bolt nut and washer including drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required. |
| 63 | Supply of 50mm x 8mm MS Flat iron pole top bracket/ cross arm for single 11/22/33kv overhead line conductor complete with fixing clamp bolts, nuts, and washer drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required. |
| 64 | Erection of pole top/ straight two wire/ V Shape two wire, angle iron/ channel iron, cross arm on steel tubular/ rail / PCC Pole for 11k/22/33KV as required. |
| 65 | Erection of double pole 3 wire cross armfor 11KV/22KV/33KV overhead line as required. |
| 66 | Providing and fixing of HT Danger notice Plate of 250mm x 200mm, made of mild steel at least 2mm thick and vitreous enameled white on both sides and with incription in single red colour on front side as required. |
| 67 | Supply of ACSR Dog Conductor (3260mtrs x 3 = 9270 mtrs ) + (10% Additional for sag) = 10,758 mtrs |
| 68 | Erection of ACSR Dog Conductor including binding as required = 0.394kg/mtr x 10,758 mtrs = 4238.65Kg |
| 69 | Supply and erection of Galvanised stay set for 11KV overhead line complete with 19/20 mm Dia x 1.8 mtrs long stay rod, anchor plate set size 45cm x 45 cm x 7.5mm thick, thimble, stay clamp, turn buckel (20mm x 600mm), 7/4.0 mm dia GI Stay wire and 11kv strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse and : 6 graded stone aggregate 40mm nominal size) foundation including excavation and refilling etc as required. |
| 70 | Supply and fitting of cradle guard |
| 71 | Dismantling of Dog conductor 1980mtrs |
| 72 | Dismantling of disc insulator 36nos |
| 73 | Dismantling of pin insulator 27nos |
| 74 | Dismantling of Iron materials |
| 75 | Dismantling of pole |
| 76 | Transportation of Dismantled Pole |
| 77 | (D) FEEDER - 8 Supply of MS Tubular pole -12 mtr |
| 78 | Erection of Metallic Pole upto 12 meter length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal) Foundation including excavation and refillingetc as required |
| 79 | Supply and erection of 11KV pin insulator complete with large steel head GI Pin, nut washer etc as required |
| 80 | Supply and erection of 11KV disc insulator for 11kv overhead line with galvanised insulator fitting, ball and socket type and complete with galvanised strain clamps, bolt, nut, washer etcas required |
| 81 | Supply and erection of GI Wire 8 SWG |
| 82 | Erection of GI wire 8 No SWG including Binding |
| 83 | Supply of AB Switch Nominal Voltage 11KV Grade, Rated voltage 12KV, 1240Amps 3 Phase outdoor Type off load disconnection in horizontal plane with earthing switch. |
| 84 | Erection of AB Switch Nominal Voltage 11KV Grade, Rated voltage 12KV, 1240Amps 3 Phase outdoor Type off load disconnection in horizontal plane with earthing switch. |
| 85 | Supplying of channel iron 75mmx 40mm x 6mm (7.14 kg per meter ) V Shape cross arm for two 11KV overhead line conductor complete with 50mm x 6mm M.S. Flat iron clamps, bolts, nuts, and washers etc (as per drawing) and painting with primer and finish paint as required. |
| 86 | Supply of two length of channel iron 75mm x 40mm x 6mm) (7.14kg per meter) double pole cross arm for three wire 11KV overhead line conductor complete with trough bolts and nuts for clamping to the poles, 50mm x 6mm MS Flat weelded on one side to the channel iron and with bolts and nuts. |
| 87 | Supplying of channel iron 75mmx 40mm x 6mm (7.14 kg per meter ) pole top bracket/ cross arm for single 11KV Overhead line conductor complete with 50mm x 6mm flat iron clamp, bolt nut and washer including drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required. |
| 88 | Supply of 50mm x 8mm MS Flat iron pole top bracket/ cross arm for single 11/22/33kv overhead line conductor complete with fixing clamp bolts, nuts, and washer drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required. |
| 89 | Erection of pole top/ straight two wire/ V Shape two wire, angle iron/ channel iron, cross arm on steel tubular/ rail / PCC Pole for 11k/22/33KV as required. |
| 90 | Erection of double pole 3 wire cross armfor 11KV/22KV/33KV overhead line as required. |
| 91 | Providing and fixing of HT Danger notice Plate of 250mm x 200mm, made of mild steel at least 2mm thick and vitreous enameled white on both sides and with incription in single red colour on front side as required. |
| 92 | Supply of ACSR Dog Conductor (3260mtrs x 3 = 9270 mtrs ) + (10% Additional for sag) = 10,758 mtrs |
| 93 | Erection of ACSR Dog Conductor including binding as required = 0.394kg/mtr x 10,758 mtrs = 4238.65Kg |
| 94 | Supply and erection of Galvanised stay set for 11KV overhead line complete with 19/20 mm Dia x 1.8 mtrs long stay rod, anchor plate set size 45cm x 45 cm x 7.5mm thick, thimble, stay clamp, turn buckel (20mm x 600mm), 7/4.0 mm dia GI Stay wire and 11kv strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse and : 6 graded stone aggregate 40mm nominal size) foundation including excavation and refilling etc as required. |
| 95 | Supply and fitting of cradle guard |
| 96 | Dismantling of Dog conductor 1980mtrs |
| 97 | Dismantling of disc insulator 36nos |
| 98 | Dismantling of pin insulator 27nos |
| 99 | Dismantling of Iron materials |
| 100 | Dismantling of pole |
| 101 | Transportation of Dismantled Pole |
| 102 | Total impact of GST for the purpose of CTC Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender