Tender For Installation Of Truss, Plaster, Ceiling, Flooring, Installation Of Doors, Windows & Allied Works Of 03 Rooms At Ups Shalote. (Under District Capex Elementary Education Sector).
Tender Value
20 Lakhs
Estimated cost
Bid Submission
17 Aug 2026
14 days left
EMD
40000
Bank guarantee accepted
Document Fee
600
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Doda → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Installation Of Truss, Plaster, Ceiling, Flooring, Installation Of Doors, Windows & Allied Works Of 03 Rooms At Ups Shalote. (Under District Capex Elementary Education Sector).
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth asdirected:1 meter from cutting edge All kinds of soil : |
| 2 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 3 | Providing and laying in position cement concrete of specified grade including curing butexcluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 4 | Providing and laying in position specified grade of reinforced cement concrete includingcuring but excluding the cost of centering, shuttering, finishing and reinforcement. Allworks upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 5 | Reinforced cement concrete work in walls (any thickness) including attached pilasters,buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts andstruts upto floor five level including curing but excluding cost of centering shuttering,finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 6 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°,landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiralstair cases upto five level including curing but excluding the cost of centring, shuttering,finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 7 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 8 | Foundations, footings, bases of columns etc. for mass concrete. |
| 9 | Lintel, beams, plinth beams, girders, bressumers and cantilevers. |
| 10 | Columns, pillars, piers, abutments, posts and struts. |
| 11 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing inposition and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 12 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 infoundation and plinth including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand) |
| 13 | Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level |
| 14 | Structural steel work Welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 15 | Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled withwhite lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.50 mm thick with zinc coating not less than 275 gram/m2 |
| 16 | Providing ridges or hips of width 60cm overall width plain G.S. sheets fixed with polymer coated J. or L hooks, bolts and nuts 8mm dia G.I. limpet and bitumen washers complete. 0.50 mm thick with zinc coating not less than 275 gram/m2 |
| 17 | Providing and fixing hard board sheet ceiling of approved quality with necessary nails etc. complete (frame work to be paid for separately) Standard Quality board |
| 18 | Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position : Budloo / Fir wood |
| 19 | Providing and fixing 30 mm thick glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butthinges bright finished of required size with necessary screws. Second class Kail wood |
| 20 | Providing and fixing 30 mm thick panelled or panelled and glazed shutters for doors,windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: -Butt hinges andnecessary screws shall be paid separately). Second kail wood |
| 21 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. Particle Board 12mm thick Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side, Grade I, Type II IS : 12823 marked |
| 22 | Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete: 2nd class kail wood 50 x 12 mm |
| 23 | 12mm Cement plaster of mix: 1 : 6 ( 1 cement : 6 fine sand) |
| 24 | 15mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 6 ( 1 cement : 6 fine sand) |
| 25 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface. |
| 26 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer |
| 27 | Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm) |
| 28 | Applying priming coat:With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 29 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work |
| 30 | Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc. complete : |
| 31 | 100x58x1.90 mm |
| 32 | 75x47x1.70 mm |
| 33 | Providing and fixing ISI marked oxidized M.S. tower bolt black finish, (Barrel type) with necessary screws etc complete. |
| 34 | 150x10 mm |
| 35 | 200x10 mm |
| 36 | Providing and fixing ISI marked oxidized M.S. handles conforming to IS : 4992 with necessary screws etc. complete : |
| 37 | 125 mm |
| 38 | 100 mm |
| 39 | Providing and fixing bright finished brass hard drawn hooks and eyes 150 mm |
| 40 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 250x16 mm |
| 41 | Supplying and filling in plinth with fine sand under floors including, watering, ramming, consolidating and dressing complete. |
| 42 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mmnominal size well rammed and consolidated and grouted with fine sand including finishingthe top smooth and curing complete |
| 43 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc including priming coat with approved steel primer all complete.Fixed to openings / wooden frames with rawl plugs screws etc. |
| 44 | Wiring for light point/ fan point / exhaust fanpoint/ call bell point with 1.5 sq. mm FRLS PVCinsulated copper conductor single core cable insurface/ recessed PVC conduit, with modularswitch, modular plate, suitable GI box earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required (Group- A) |
| 45 | IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminium housing with in built driver , System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption shouldnot more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. 20/22 watt LED 4 feet with min. lumen output (2000- 2200) lm |
| 46 | Supplying and fixing of ceiling fan offollowingsweep with 2.25 mfd condenser and 1'-6\\" down rod on the existing fan hook with necessary connection from ceiling rose to fan using twin core copper wire. 1200 mm sweep (As approved by Engineer In Charge) |
| 47 | CARRIAGE OF MATERIALSBy Mechanical Transport and Head load including loading, unloading and stacking |
| 48 | Carriage of Sand / Dust avg. lead of 20.00 km by MT & 50 Mtr. By HL. |
| 49 | Carriage of stone aggregate below 40 mm nominal size at an avg. lead of 20.00 km by MT & 50 Mtr. By HL. |
| 50 | Carriage of Bricks at an avg. lead of 200.00 km by MT & 50 Mtr. By HL. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 03, 2026
11:30 IST
Tender Published
Tender notice published.
TodayAug 17, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysAug 18, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 15 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender