Tender For Creation Of 400 Kva & 250 Kva Sub-Station Along With Ht /Lt Network At Achan.

Issued by Government Departments · Srinagar, Jammu and Kashmir
Tender Value
76.54 Lakhs
Estimated cost
Bid Submission
17 Aug 2026
13 days left
EMD
1.53 Lakhs
Bank guarantee accepted
Document Fee
1500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Srinagar → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Creation Of 400 Kva & 250 Kva Sub-Station Along With Ht /Lt Network At Achan.

BOQ

Name of Work:- Creation of 400 KVA & 250 KVA Sub-station along with HT /LT Network at Achan.
Sl. No. Item Description
1Supply ,Installation ,Testing & Commissioning of following for creation of 250 kVA substation
2250 kVA ,11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, Copper wound , and with LV Cable Box having detachable Aluminium Gland plate
3Steel Tubular poles 9mtr (410 SP33) complete with base plate (300x300x5mm), top cap,pit depth = (1.5mtr)
4GI Channel/Angle/Flat of sizes including clamps including 11KV isolator mounting channels
511KV Polymer composite Pin insulator 12 kV, 5 kN, Lighting Impulse 75 kV positive and 80 kV negative, creepage distance 320 mm.
611KV G.O AB Switch 3-phase, 3pole 200-Amp, vertical Type
711KV Horn Gap Fuse set, 3Phase 200A
8Gap less Surge Arrestor, 11KV, 10 Ka, LA with Polymer housing Station Type.
9Galvinized Nuts & Bolts
10240mm² single core Cable,1.1kV Grade, XLPE Insulated Stranded Conductor FRLS type
11Wedge Connectors / PG Clamps
12240 sq mm Al.thimbles
13LT Distribution Box for: 250 kVA DTR with 400 Amp MCCB 3P 36 kA for incomer & 200 Amp MCCB 3P 16 kA 1 No. and 160 Amp MCCB 3P 16 kA 2 No.s for Outgoing Circuits
14Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthingof size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
15Danger Plate
16Cement bottoming of S T poles in 1:2:4 mix,as per REC standards 0.48 cum/pole
17Earthing complete by GI pipe 40 mm or GI Rod 20 mm 2.5 mtr long through GI strip
18Painting of Steel Tubular poles with one coat of red oxide paint (1 ltr /Pole )
19Painting of Steel Tubular poles with two coats of aliminium paint (1 ltr /Pole )
20GI barbed wire for anti climbing with clamps etc
21Sundry items like Aluminium lugs, Jumpers, Binding Tape,
2211KV HT Trivector meter with suitable CT& PT operated along with all accessories
23Supply ,Installation ,Testing & Commissioning of following for HT Network
24Steel Tubular poles 9mtr (410 SP33) complete with base plate (300x300x5mm), top cap,pit depth = (1.5mtr)
25GI V Cross arm with top bracket including clamp, nuts and bolts
2611KV polymeric composite pin insulator 12KV,5KN,lighting impulse 75KV positive and 80KV negative, creepage distance 320mm
2752.88 mm² AL59 Aluminium claded steel Conductor (Covered Conductor)
28Heat Shrinkable Outdoor Cable Termination Kit
29Tension Clamps with bail and IPC (Insulation piercing conductors)
30IPC for CC to CC connection
31IPC with Aluminium bail for earthing
32Mid Span joint
33Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long,20 mm diameter solid GS stay rod & 7/4 mm dia GI stranded wire complete
34Cement bottoming 1:2:4 mix as per Standards 0.48 cum /pole
35Galvinized Nuts and Bolts
36Earthing Complete by GI Pipe 40 mm 3 mtr long through GI Strip.25x3mm
37Painting of Steel Tubular poles with one coat of red oxide paint (1 ltr /Pole )
3811KV Isolator Double Break, 3-pole, 630 Amps, Horizontal Mounting Type , with earth switch
39Painting of Steel Tubular poles with two coats of aliminium paint (1 ltr /Pole )
40Supply ,Installation ,Testing & Commissioning of following for LT Network
41Steel Tubular poles 8mtr (410 SP15) complete with base plate
42Heat Shrinkable Outdoor Cable Termination Kit
43120 mm² XLPE LT AB Cable (3X120+1X95 ) Insulated (1.1kV, 3C+ Earth)
44Suspension/Tension Clamp with eye hook
45Galvinized Nuts and Bolts
46Cement bottoming of S T poles in 1:2:4 mix,as per REC standards 0.48 cum/pole
47Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6) mm, nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
48Earthing complete by GI pipe 40 mm or GI Rod 20 mm 2.5 mtr long through GI strip
49Painting of Steel Tubular poles with one coat of red oxide paint (1 ltr /Pole )
50Painting of Steel Tubular poles with two coats of aliminium paint (1 ltr /Pole )
51Supply ,Installation ,Testing & Commissioning of following for creation of 400 kVA substation
52400KVA , 11/0.433kV, 3-phase Distribution Transformer with Bimetallic Terminal Connectors Energy Level-2, Copper CU wound for 400KVA , and with LV Cable Box having detachable Al. Gland plate with LV Bimetallic terminal connection suitable for vertical take off of cable. ( X-mer without OLTC (Off Ckt Tap Changer))
53Galvinized Nuts and Bolts.
54GI Channel/Angle/Flat of sizes including clamps for L.A Set/G.O Set/Horn Gap
55Steel Tubular poles 9mtr (410 SP33) complete with base plate (300x300x5mm), top cap,pit depth = (1.5mtr)
56G.I Pipe of 150 mm dia 2 mtr long for Pole Butts (6\\")
57Transformer Pad/G.I Channel Bedding (300Kg)
5811KV Polymer composite Pin insulator 12 kV, 5 kN, Lighting Impulse 75 kV positive and 80 kV negative, creepage distance 320 mm.
5911KV G.O AB Switch 3-phase, 3pole 200-Amp, vertical Type
6011KV Horn Gap Fuse set, 3Phase 200A
61Gapless Surge Arrestor, 11KV, 10 Ka, LA with Polymer housing Station Type.
62300 mm²(3Ckt) XLPE Insulated cable Stranded Conductor FRLS type
63Wedge Connectors / PG Clamps
64300 sq mm Al.thimbles
65LT Distribution Box for: i). 400 kVA DTR with 630 Amp MCCB 3P (36 KA) adjustable 1 No. for incomer & 200 Amp 3 P (16 KA) 4 No.s fixed for Outgoing Circuits.
66Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthingof size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
67Danger Plate
68Cement bottoming of S T poles in 1:2:4 mix,as per REC standards 0.48 cum/pole
69Earthing complete by GI pipe 40 mm or GI Rod 20 mm 2.5 mtr long through GI strip
70Painting of Steel Tubular poles with one coat of red oxide paint (1 ltr /Pole )
71Painting of Steel Tubular poles with two coats of aliminium paint (1 ltr /Pole )
72GI barbed wire for anti climbing with clamps etc
73Sundry items like Aluminium lugs, Jumpers, Binding Tape,
7411KV HT Trivector meter with suitable CT& PT operated along with all accessories
75Supply ,Installation ,Testing & Commissioning of following for LT Network
76Steel Tubular poles 8mtr (410 SP15) complete with base plate
77Heat Shrinkable Outdoor Cable Termination Kit
78120 mm² AB Cable (3X120+1X95 insulated)mm² XLPE (1.1kV, 3C+ Earth)
79Suspension/Tension Clamp with eye hook
80Galvinized Nuts and Bolts
81Cement bottoming of S T poles in 1:2:4 mix,as per REC standards 0.48 cum/pole
82Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6) mm, nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
83Earthing complete by GI pipe 40 mm or GI Rod 20 mm 2.5 mtr long through GI strip
84Painting of Steel Tubular poles with one coat of red oxide paint (1 ltr /Pole )
85Piericing connector
86Painting of Steel Tubular poles with two coats of aliminium paint (1 ltr /Pole ) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56795881
AUTHORITY Government Departments
TENDER VALUE 76.54 Lakhs
LAST DATE 17-08-2026
Authority
Authority Name Srinagar Municipal Corporation
Work Description Tender for Creation Of 400 Kva & 250 Kva Sub-Station Along With Ht /Lt Network At Achan.
Basic Detail
Tender No Tender Notice No. 13 Of 2026-27 Electric
Bidding Type Tender
Location
City Srinagar
State Jammu and Kashmir
Key Dates
Publish Date 01 Aug 2026
Submission Date 17 Aug 2026
Open Date 18 Aug 2026
Finance
Tender Value 76.54 Lakhs
Tender Fee 1500
EMD 1.53 Lakhs
Exemption Not Available
Document List
BOQ_1054600.xls
d7b63847-9c86-4041-9d93-0c4ffe57fa9c.html
TechSpecsDTSCOPPER.pdf
TechSpecsPoles.pdf
Tendernotice_1 (11).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 01, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 17, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 13 days
Aug 18, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 14 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_1054600.xls

html

d7b63847-9c86-4041-9d93-0c4ffe57fa9c.html

pdf

TechSpecsDTSCOPPER.pdf

pdf

TechSpecsPoles.pdf

pdf

Tendernotice_1 (11).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders