Tender For Re-Conditioining /Overhauling Of 33-66 Kv/11 Kv, 10 Mva-6.3 Mva Power Transformers Installed Under The Jurisdiction Of Std-Ii Division, Jpdcl On Turnkey Basis.
Tender Value
1.08 Crore
Estimated cost
Bid Submission
20 Aug 2026
5 days left
EMD
2.16 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jammu → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Re-Conditioining /Overhauling Of 33-66 Kv/11 Kv, 10 Mva-6.3 Mva Power Transformers Installed Under The Jurisdiction Of Std-Ii Division, Jpdcl On Turnkey Basis.
BOQ
| Sl. No. | Item Description |
| 1 | Lifting and shifing of spare power transformer to and fro from Div store to the site and its temporary installation at site to free Power Transformer to be overhauled. |
| 2 | Supply and Replacement of Cork Sheet Gasket sets for Power Transformer to be overhauled (which inlcudes main tank top cover, OLTC top main gasket, Inspection windows gasket, Radiators valve gasket , Buchholz Relay gasket, Bush gasket LT/HT and damaged rod / clamps etc.) wherever required. |
| 3 | Transformer Oil filtration at site using vacuum pump oil filtration machine including pre and post BDV value check, including Drainage & Refilling of oil into barrels. |
| 4 | Supplying & Topping up of fresh Transformer oil in 210 ltrs of drum |
| 5 | Supplying of Transformer breather including fresh silica gel filled in |
| 6 | Supplying and Installation of Buchholz Relay |
| 7 | Supply & Installation of Busha) LT Bush |
| 8 | b) HT Bush |
| 9 | Supply & Installation of Roda) LT Rod |
| 10 | b) HT Rod |
| 11 | Testing of Power Transformer ( Megger , P.I, D.A.R, Magnetising Current measurement, Magnetic Balance & Winding Resistance Measurement, Tan delta of Windings & DGA of main tank oil ) |
| 12 | Arrangement of Stand by DG set ( 3-phase , 45 kVA) for carrying out Oil filtration and Testing works inclusing fuel charges |
| 13 | Earthing as per approved drawings with minimum scope of work as - Conventional GI plate earthing ( 600 mm X 600 mm X 6mm) , 40 mm dia., 3000 mm long GI pipe tied with GI plate electrode with test link, RCC pit, RCC cover plates on GI frame, 50 kg of bentonite powder per pit and other accessories complete to strengthen Power Transformer Neutral earthing and connecting it to main earth mat - Complete Job |
| 14 | Dismantling & Refitting of Radiator Butterfly valve as per requirement & arrest of oil leakage |
| 15 | Replacement of oil temperature meter |
| 16 | Replacement of sundry / unforeseen items |
| 17 | Replacement of Oil Drain valve |
| 18 | Supplying & Replacement of Pressure Relief valve |
| 19 | Flushing out sludge from the transformer |
| 20 | Painting of Transformer including paint |
| 21 | Supply & installation of 10 kVA, 240 V AC single-phase silent diesel generator set (To be supplied to the Divisional Stores) |
| 22 | Supply of Transformer oil filtration plant capacity 3000 LPH, Single Stage high vacuum, as per IS-6034-1989 with micro filters cartidges, inlet & outlet hoses of 15m length, skid mounted mobile plany/machine on tyres ( 7 inches X 16 inches, section width x rim diameters) minimum. (To be supplied to the Divisional Stores) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 01, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 20, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysAug 22, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender