Tender For Special Repair Of Other Rank Living Accommodation Bldg No To-243 Of 203 Army Avn Sqn (Uh) Under Age B/R-I Of Ge 865 Ews,Leh
Tender Value
11.81 Lakhs
Estimated cost
Bid Submission
24 Aug 2026
1 days left
EMD
23700
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
leh → Ladakh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Special Repair Of Other Rank Living Accommodation Bldg No To-243 Of 203 Army Avn Sqn (Uh) Under Age B/R-I Of Ge 865 Ews,Leh
BOQ
| Sl. No. | Item Description |
| 1 | M&L 6mm (5 ply) thick veneered decorative (Knoty Pine) plywood, grade 1 (with BWR resin) with decorative face veneers on one face, fixed with nails to timber frame work as in wall , including dismantlng, complete all as specified and as directed. |
| 2 | M&L 6mm (5 ply) thick veneered decorative (Knoty Pine) plywood, grade 1 (with BWR resin) with decorative face veneers on one face, fixed with nails to timber frame work as in ceiling , including dismantlng, complete all as specified and as directed. |
| 3 | M&L for 2nd class soft wood clean sawn as in battens for grids of ceiling & lining fixed with nails exc 13 sqcm and n exc 25 sqcm in section including Dismantlng .complete all as specified and as directed. |
| 4 | M&L for 2nd class soft wood clean sawn as in beeding for edges of Ceiling ,lining ,or wooden flooring work fixed with nails exc 6 sqcm and n exc 13 sqcm in section including Dismantlng complete all as specified and as directed. |
| 5 | M&L for covered fillets of standard hard board not less than 6mm thick and up to 40mm wide and fixing with screws including Dismantlng complete all as specified and as directed |
| 6 | M&L French polishing on wood or wood based surface of any width or girth or any description,including cleaning and preparing the surface including a coat of wood filler o new surface with two or more coats complete all as specified and as directed. |
| 7 | M&L for hard wood 2nd class factory made wooden boarded floors 10mm thick and skirtings planed one side & edges tonged and grooved or rebated , including backing with thermocol sheets or as specified by manufacture including Dismantlng all as specified and directed. |
| 8 | S&F in repairs viterous China squatting pan or Orissa pattern 580 x 440 mm white with integral foot rest (excluding cistern and flush pipe) but including connection to 100mm dia trap 'P' or 'S', anti syphonage pipe etc complete all as specified and as directed by Engr-in-Charge. |
| 9 | S&F in repairs, 10 litres capacity PVC valveless syphonic action type, flushing cistern (ISI marked), low level ,white ,with inlet, ball valve, float and handle including bracket & flush pipe of polyethylene of low or high density or high density or PVC,32mm dia,for low level cistern complete all as specified & directed by Engr-in-charge. |
| 10 | Demolition of cement concrete in ground floor and pavings n'exc 15cm thick below or above ground level complete all as specified and as directed |
| 11 | M&L for 25 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate as in sub base of floor complete all as directed by Engr-in-charge. |
| 12 | M & L Non-Skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm not exceeding 0.16 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed or bedding layer in Cement Mortar 1:6 for laying floor finishes incl incl dismantling floor tiling including cement mortar bedding (but not backing), removing serviceable tile to store and rubbish off the premises complete all as specified and directed. |
| 13 | Taking down shutters of any description area exceeding 1 Sqm and not exceeding 2 Sqm each complete all as directed by Engr-in-charge. |
| 14 | S&F for 40 mm thick Flush shutters, solid core construction ,with block board core and plywood face panels commercial type on both sides , Supply and fixed to chowkats , complete all as directed by Engr-in-charge. |
| 15 | S&F mild steel butt hinges, medium weight cold rolled 100mm size complete all as specified and as directed. |
| 16 | S&F 150mm long aluminium anodized, barrel tower bolt of extruded section complete all as specified and as directed. |
| 17 | S&F 150mm size extruded aluminium alloy handles, fabricated type, anodized complete all as specified and as directed. |
| 18 | S&F in 250mm long aluminium alloy, anodized, sliding door bolt with hasp & staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolt and sliding bolts of extruded section or cast aluminium alloy fixed complete all as specified and as directed |
| 19 | S & F floor door stopper 150mm long of aluminium alloy body and tongue, anodised with hard drawn steel spring fixed complete all as specified and as directed. |
| 20 | S & F 25mm dia 3 layer PP-R polypropyene random copolymer concealed pipes SDR 7.4 (PN 16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete all as per manufacture instructions and as directed by Engineer in Charge and including taking up or down 25 mm bore steel tubing / PPR pipe and connections and set aside for re-use or removal to store. |
| 21 | S & F 32mm dia 3 layer PP-R polypropyene random copolymer concealed pipes SDR 7.4 (PN 16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete all as per manufacture instructions and as directed by Engineer in Charge and including taking up or down 32 mm bore steel tubing / PPR pipe and connections and set aside for re-use or removal to store. |
| 22 | S&F in repair 25mm outer dia PPR Gate valve (Brass insert) confirming to ISO 2000 high pressure with epoxy coated aluminium rod and high density plastic ball screwed for PPR pipe or for union and fixed as per requirement of site completely all as specified and directed by the Engr-in-Charge. |
| 23 | S&F in repair 32mm outer dia PPR Gate valve (Brass insert) confirming to ISO 2000 high pressure with epoxy coated aluminium rod and high density plastic ball screwed for PPR pipe or for union and fixed as per requirement of site completely all as specified and directed by the Engr-in-Charge. |
| 24 | S & F 500 litres capacity rotational moulded polyethylene water storage tanks inner and out white, two layers ISI marked (Cylindrical vertical, with closed top), hoisted with threaded cap and fixed in position all as specified in SSR Part I including all accessories (ie GI nipple etc), including provn of 20/25 mm dia spout for connecting inlet, outlet, over flow and washout pipes and including dismantling water tanks and removing to store Exc 250 and n exc 500 ltrs capacity complete all as specified and as directed by Engr-in-Charge. |
| 25 | S&F in repair 25mm outer dia PPR Ball valve (Brass insert) confirming to ISO 2000 high pressure with epoxy coated aluminium rod and high density plastic ball screwed for PPR pipe or for union and fixed as per requirement of site completely all as specified and directed by the Engr-in-Charge. |
| 26 | S & F in repairs Fancy type 15 mm bore chromium plated bib taps, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 27 | S & F in repair fancy type 15 mm bore pillar taps, Cast Copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed. |
| 28 | S&F in repairs, 15 mm bore, PVC connection pipe 600 mm long with PTMT nuts at both ends complete all as specified and directed. |
| 29 | S&F in repair 600x450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial ply wood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed by Engr-in-Charge. |
| 30 | S & F in repair CP floor gratings 150mm dia all as directed by the Engr-in-Charge |
| 31 | S & F Chrominum plated brass soap dish (Oval shape) to walls (size not less than 125mm long) complete fix to wall all as specified and direced by Engr-in-Charge |
| 32 | S & F in repair fancy type ,chromium plated 20 mm bore Angle Stop valves, cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed. |
| 33 | S & F in repair 4.80 mm thick Sheet glass, ordinary quality and glazing with oil putty in squares not exceeding 0.5 Sqm in each pane including hacking out old broken glass (any thickness, size, quality or description) from metal frames including punching or drilling out old glazing pins / spring clips and providing new pins / spring clips. complete all as specified and directed by Engr -in-Charge. |
| 34 | M & L for 75 mm PCC 1:3:6 type C-2 using 20mm graded aggregate as plinth protection finished even and smooth with out using extra cement |
| 35 | M&L Forming Contraction (Dummy) joints 65 mm deep x 10mm wide, filled with sealing compound Grade 'A' in plinth protection |
| 36 | S&F in repairs Towel Hnager with 6 Nos of pin and 600mm long Cromum plated etc complete fitted as per sepcified and directed by Engr-in-charge |
| 37 | Dismantling of CI/PVC pipe any type and size etc as per specified and directed by Engr-in-charge. |
| 38 | M&L for Cast iron Nahani trap 75mm in repair with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) |
| 39 | M&L for PVC (SWR) pipe single socketed, 75mm dia soil, waste and rain water dranage pipes laid in trenches and jointed all as specified |
| 40 | Dismantling wrought iron or mild steel work of any description not otherwise provided for. |
| 41 | S&F MS Rolled sections in main and cross beams,hip and jack rafters ;purlins where connected to common rafters running rails and guids for sliding doors ;fixed with angle cleats or other connecting plates and similar work confirming to Fe-290, Gde-E-165 complete all as specified and as directed. |
| 42 | Dismantling plain or corrugated steel /fibre sheeting any guage thickness including nanital or similar pattern complete all as specified and as directed |
| 43 | S&F Pre painted galvalumealuminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mps as in roof covering /cladding to wall fixed with self tapping screws as specified |
| 44 | M&L for preperation and removal of old Steel / CGI Sheet surface any description over 10cm in width or girth and applaying two coat of synthetic enamal paint all as specified and as directed complete all as specified and as directed. |
| 45 | S&F in repair 19mm dia mild steel, chromium plated curtain rods, with brackets, end bulbs all as specified and as directed by Engr-in-charge. |
| 46 | Taking down carefully copper/aluminium point wiring (light, fan, socket and power point) complete fittings such as switches, ceiling rose, regulators, socket etc and removing material from site and making good disturbed surfaces of walls, floors/ceiling to match the existing surface all as spfd and directed by Engr-in-Charge. |
| 47 | Point wiring complete with 1.5Sq.mm nominal area of copper conductor multi stranded PVC insulated and unsheathed 1100 volts cable drawn through & including PVC Casing & caping with standard accessories such as elbows, tees, junctions etc. and PVC moulded terminal box with top cover of including PVC insulated unsheathed solid 1.5Sqmm copper conductor cable as continuous earth lead complete all as specified and directed for the followings:- |
| 48 | One light point/fan controlled by one way switch complete all as specified and directed. |
| 49 | One socket outlet 5 Amps, 230 volts point on independent board complete all as specified and directed. |
| 50 | One Socket outlet 5 Amps, 230 volts point on Same board complete all as specified and directed. |
| 51 | All as item No 47 above, but using cables 4 Sq mm size complete all as specified and directed. |
| 52 | Supply and fix Switch piano flush button single pole 6 Amps 230 volts one way complete all as specified and directed. |
| 53 | Supply and fix Socket out let two in one 5 pin 6 Amps flush type.230 volts complete all as specified and directed. |
| 54 | Supply and fix switch Socket combination out let multi purpose 5 pin 6 Amps and 16Amps 230 volts complete all as specified and directed. |
| 55 | Supply and fix Ceiling rose, surface Bakelite three terminals complete all as specified and directed. |
| 56 | Supply and fix in replacement of sheet metal enclosure for DBs double door when MCB's to be used single pole & neutral 240 Volts 12 complete all as specified and directed. |
| 57 | Supply and fix in replacement of MCB SPN 40 to 63 Amp 240 Volts AC ISI marked complete all as specified and directed. |
| 58 | Supply and fix in replacement of MCB SP 6-32 Amps. 240 Volts 50 HZ complete all as specified and directed. |
| 59 | Supply and Fixing only in Replacement LED light fitting 1X20 W, 220 V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 60 | Taking down old unserviceabole exhaust fan and supply and fix in repair exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete all as specified and directed. |
| 61 | M & L for submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/recessed as required in PVC casing Caping wire size 2x 2.5 sq. mm + 1x 2.5 sq. mm earth wire complete all as specified and directed. |
| 62 | Excavation in trenches not exceeding 1.5m in wide and not exceeding 1.5 m in depth for laying of pipe etc and getting out in hard soil, complete all as specified and directed. |
| 63 | M & L for returning, filling in including spreading leveling watering and well ramming in layers not exc. 25 cm thick complete all as specified and directed.(Surplus soil if any shall not be removed but left over the trench) |
| 64 | M & L for removing surplus soil to a distance not exc. 50 M and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed. |
| 65 | M & L for sand cushioning with clean dry sand to cables with layer of sand 8 cm before laying of cable and 15 cm thick after laying of cable complete all as specified. |
| 66 | M & L for providing PCC cable cover class LV type-I of size 250x150x40mm laid in perpendicular to the cable abutting each other all as specified and directed at site. |
| 67 | Labour only for laying of old serviceable cable covers retrieved from excavation complete all as specified and directed by Engineer-in-Charge. |
| 68 | Supply & laying in replacement of existing unserviceable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volt grade of cross sectional area 50 Sqmm 3.5 Core complete all as specified and directed. Please Enable Macros to View BoQ information |
| 69 | Supply & laying in replacement of existing unserviceable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volt grade of cross sectional area 50 Sqmm 3.5 Core complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 01, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 24, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 dayAug 31, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender