Tender For Repair / Replacement And Servicing Of Central Heating System At Corps Officers Mess And Signal Centre Including Connected Works At Sector A Under Age E/M-I Of Ge 865 Ews
Tender Value
47 Lakhs
Estimated cost
Bid Submission
22 Aug 2026
3 days left
EMD
94000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
multi state → Multi State
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Repair / Replacement And Servicing Of Central Heating System At Corps Officers Mess And Signal Centre Including Connected Works At Sector A Under Age E/M-I Of Ge 865 Ews
BOQ
| Sl. No. | Item Description |
| 1 | M&L in replacement for 80mm dia MS ERW pipe heavy grade 'C' Class complete with welded ends laid in ducts over the angle iron supports/ fixed on the walls/ trenches including fittings, complete all as specified and/or as directed by Engr-in-Charge. Note : The item rate is inclusive of cutting to any levels/shapes like elbows, tees, bends etc. welding joints wherever necessary as per the site requirement. |
| 2 | All as per Srl item No 1 above but of size 50mm. |
| 3 | All as per Srl item No 1 above but of size 40mm. |
| 4 | All as per Srl item No 1 above but of size 32mm. |
| 5 | All as per Srl item No 1 above but of size 25mm. |
| 6 | All as per Srl item No 1 above but of size 20mm. |
| 7 | Taking out the unserviceable insulation from MS ERW pipe of size 80mm bore and providing for Insulation of MS pipe with PUF slab 40 mm thick and applying bituminuous compound and GI cladding with 26 gauge GI sheet complete including complete earthwork for clearance around the pipe, complete all as specified and/or as directed by Engr-in-Charge. |
| 8 | Taking out the unserviceable insulation from MS ERW pipe of size 80mm bore and providing for Insulation of MS pipe with PUF slab 30 mm thick and applying bituminuous compound and GI cladding with 26 gauge GI sheet complete including complete earthwork for clearance around the pipe, complete all as specified and/or as directed by Engr-in-Charge. |
| 9 | All as per Srl item No 8 above but of size 40mm. |
| 10 | All as per Srl item No 8 above but of size 32mm. |
| 11 | All as per Srl item No 8 above but of size 25mm. |
| 12 | All as per Srl item No 8 above but of size 20mm. |
| 13 | M&L for replacement of cast iron butterfly valve of size 80mm dia Class PN 1.6 with SG iron dice flanged ends (integrally cast) horizontal type, conforming to IS-14846 (ISI marked) with stainless steel spindle and iron wheel non rising type including jointing material complete such as rubber or fibre board insertion packing rings with requisite numbers of nuts, bolts & washers etc. including taking out existing unserviceable valve, complete all as specified and/or as directed by Engr-in-Charge. |
| 14 | Dismantling of burner assembly at Corps Offrs Mess CHS and removing of side cover of boiler capacity 1.5 lakh kilo/cal/hr and complete servicing the boiler including exhaust outlet i.e. chimney by removing the complete carbon/oil deposits with suitable coil shine chemical including repair to coil assembly by welding if there is any leakage found or any other repair required at site and reassembling/ testing the same (again after 4 months of again servicing), complete all as specified and/or as directed by Engr-in-Charge. |
| 15 | All as per Srl item No 14 above but for 1 lakh kilo/cal/hr including all filters of radiator assembly at Signal Centre. |
| 16 | M&L for rewinding of electric motor 3 phase 415 volts of capacity 3 HP with superior quality super enameled copper winding wire of appropriate size and gauge as existing including varnishing, cotton tape, PVC sleeves etc., complete all as specified and/or as directed by Engr-in-Charge. |
| 17 | M&L for rewinding of electric motor 3 phase 415 volts of capacity 2 HP with superior quality super enameled copper winding wire of appropriate size and gauge as existing including varnishing, cotton tape, PVC sleeves etc., complete all as specified and/or as directed by Engr-in-Charge. |
| 18 | S&F in sequence controller suitable for 1.0 to 1.5 lakh kilo/cal/hr with burner rod assembly, complete all as specified and/or as directed by Engr-in-Charge. |
| 19 | S&F in replacement of ignition rod suitable for 1.0 to 1.5 lakh kilo/cal/hr with burner rod assembly, complete all as specified and/or as directed by Engr-in-Charge. |
| 20 | S&F in replacement of ignition transformer electronic type suitable for 1.0 to 1.5 lakh kilo/cal/hr with burner rod assembly, complete all as specified and/or as directed by Engr-in-Charge. |
| 21 | M & L for complete servicing of diesel pumps suitable for boiler of capacity 1.0 to 1.5 lakh kilo/cal/hr including replacement of bearings, seal etc. as per site requirement, complete all as specified and/or as directed by Engr-in-Charge. |
| 22 | S&F temp controller digital type DTC 503 with sensor suitable for 1.0 to 1.5 lakh kilo/cal/hr LAL 2.25 burner rod assembly, complete all as specified and/or as directed by Engr-in-Charge. |
| 23 | S&F in replacement of photo cell as per existing suitable for 0.6 to 1.5 lakh kilo/cal/hr burner rod assembly,complete all as specified and/or as directed by Engr-in-Charge. |
| 24 | S&F in replacement of burner nozzle suitable for 0.6 to 1.5 lakh kilo/cal/hr, complete all as specified and/or as directed by Engr-in-Charge. |
| 25 | S&F in replacement of electrode suitable for burner of capacity 0.6 to 1.5 lakh kilo/cal/hr, complete all as specified and/or as directed by Engr-in-Charge. |
| 26 | S&F in replacement of pressure gauage 0 to 20 Kg/sq cm as per existing, complete all as specified and/or as directed by Engr-in-Charge. |
| 27 | S&F in replacement of thermostate assembly tail type as per existing suitable for 0 to 30 degree centrigrade temperature, complete all as specified and/or as directed by Engr-in-Charge. |
| 28 | S&F in replacement of auto air pressure valve 3/8\\" as per existing, complete all as specified and/or as directed by Engr-in-Charge. |
| 29 | S&F in replacement of high pressure fuel pipe 1.5 mtr as per existing, complete all as specified and/or as directed by Engr-in-Charge. |
| 30 | M&L for replacement of burner complete assembly single phase 220 volts, Make : Bentone, Type ST-120, Model-ST-120K or equavelent, eco flame capacity 2 to 5.6 Kg/hr, suitable for 1.5 lakh kilo/cal/hr boiler,complete all as specified and/or as directed by Engr-in-Charge. |
| 31 | M&L for replacement of burner complete assembly single phase 220 volts, Make : Bentone, Type ST-120, Model-ST-120K or equavelent eco flame capacity 2 to 5.6 Kg/hr, suitable for 1 lakh kilo/cal/hr boiler, complete all as specified and/or as directed by Engr-in-Charge. |
| 32 | M&L for disconnecting the AHU any capacity complete shifting to outside of the building and replacing unserviceable parts cleaning inside and outside and testing, complete all as specified and/or as directed by Engr-in-Charge. |
| 33 | S&F in replacement of V-Belt, B-108, suitable for AHU motor. |
| 34 | S&F in replacement of inlet/outlet forged brass ball valve 20 mm with Y stainer for FCU, hot water for -25 to 90 degree temperature as per existing, including supply and fixing GI nipple of size 3/4 inch including welding work, cutting the existing rusty unserviceable MS/GI nipple, complete including taking out existing unserviceable valve,complete all as specified and/or as directed by Engr-in-Charge. Make : KIRLOSKAR/TATA/LEADER/L&T or equivalent as approved by GE. |
| 35 | S&F and replacement of inlet/outlet forged brass ball valve 25 mm with Y stainer for FCU, hot water for -25 to 90 degree temperature as per existing, including supply and fixing GI nipple of size 3/4 inch including welding work, cutting the existing rusty unserviceable MS/GI nipple, complete including taking out existing unserviceable valve, complete all as specified and/or as directed by Engr-in-Charge. Make : KIRLOSKAR/TATA/LEADER/L&T or equivalent as approved by GE. |
| 36 | S&F and replacement of forged steel globe valve, bolted bonnet outside screw & yoke type rising stem for 20mm dia complete including taking out existing unserviceable valve, complete all as specified and/or as directed by Engr-in-Charge. Make : KIRLOSKAR/TATA/LEADER/L&T or equivalent as approved by GE. |
| 37 | All as per Srl item No 36 above but of size 25mm dia bore. |
| 38 | All as per Srl item No 36 above but of size 32mm dia bore. |
| 39 | All as per Srl item No 36 above but of size 40 mm. |
| 40 | All as per Srl item No 36 above but of size 50 mm. |
| 41 | Brass flare nuts of size 20/15 mm bore and fix the brass valves/FCUs including taking out existing unserviceable valve, complete all as specified and/or as directed by Engr-in-Charge. |
| 42 | S&F in replacement of FCU connection flexible pipe 20/16 mm as per existing, complete all as specified and/or as directed by Engr-in-Charge. Make- Jindal/Kitetac or equivalent as approved by GE. |
| 43 | M&L for complete cleaning and checking the serviceability of fan coil unit of any capacity for having continuous sreviceability of FCU for any number of time as desired by Engr-in-Charge including replacement of minor spare part like Gasket, Teflon tape, flare nut, tightening of any loose glycol line connections, shifting FCU from one place to another place if required, heating up the freezed glycol line anywhere about the premises and cleaning with the chemical solution by pressure pump from inlet to outlet to have continuous flow of glycol fluid, repairing the insulation of pipe line of any size by providing shallow tape / GI wire as deemed fit, for fastening the insulation with pipe line, stopping any kind of leakage from any size of pipe line, tightening the loose electrical connections as related with FCU / Heating system, cleaning the air filter including radiator of FCU to the entire satisfaction of Engr-in-Charge at site, complete all as specified and/or as directed by Engr-in-Charge. |
| 44 | S&F in replacement of fan coil unit duel shaft electric motor 1/12 HP, 30 watt 930 RPM, 3 speed as per existing, complete all as specified and/or as directed by Engr-in-Charge. Make- Maratan/CEG or equivalent as approved by GE. |
| 45 | S&F radiator unit of FCU including connecting with the unit and making it leakproof of capacity 1.5 TR consisting of copper coils covered with aluminium finsing as per existing size of capacity 3000 Kilo/cal/hr including dismantling the existing unserviceable, complete all as specified and/or as directed by Engr-in-Charge. |
| 46 | S&F radiator unit of FCU including connecting with the unit and making it leakproof of capacity 2.5 TR consisting of copper coils covered with aluminium finsing as per existing size of capacity 4500 Kilo/cal/hr including dismantling the existing unserviceable, complete all as specified and/or as directed by Engr-in-Charge. |
| 47 | Welding the leakage portion of MS pipe line including earthwork complete and materials as required for welding the pipe line of size 25 mm to 80 mm including testing on full pressure, complete all as specified and/or as directed by Engr-in-Charge. |
| 48 | M&L for cleaning of MS overhead POL storage tank of capacity 2000 ltr including all type of T&P and chemical required for the same, including welding work to leakage surface including opening and refixing the existing insulating materials to the external surface of storage tank, complete all as specified and/or as directed by Engr-in-Charge. |
| 49 | M&L for replacement of old unserviceable centrifugal monoblock pump 3 phase 415 volts of capacity 5 HP with mechanical seal complete fittings with accessories, complete all as specified and/or as directed by Engr-in-Charge. Make : Kirloskar / Havells / Texmo / CG or equivalent as approved by by GE. |
| 50 | M&L for replacement of old unserviceable centrifugal monoblock pump 3 phase 415 volts of capacity 3 HP with mechanical seal complete fittings with accessories, complete all as specified and/or as directed by Engr-in-Charge. Make : Kirloskar / Havells / Texmo / CG or equivalent as approved by by GE. |
| 51 | T&P alongwith labour only for attending of complaint for day to day / daily complaints by employed skilled staff, checking the serviceability of fan coil unit of any capacity for having continuous serviceability of FCU for any number of time as desired by Engr-in-Charge including replacement of minor spare part like Gasket, Teflon tape, flare nut, tightening of any loose glycol line connections, shifting FCU from one place to another place if required, heating up the freezed glycol line anywhere about the premises to have continuous flow of glycol fluid, repairing the insulation of pipe line of any size by providing shallow tape / GI wire as deemed fit, for fastening the insulation with pipe line, stopping any kind of leakage from any size of pipe line, tightening the loose electrical connections as related with FCU / Heating system, cleaning the air filter including radiator of FCU to the entire satisfaction of Engr-in- Charge all as directed at site. Note : (i) Attending any complaints of different nature in a single day in Corps HQ Complex Plant Room inside / outside will be considered as one job. (ii) Any kind of replacement of major items shall be measured and paid for separately under respective item of schedule 'A'. (iii) Any nature of complaint related with FCUs, radiators, bursting/cracking/leakage of MS pipe lines, replacement of valves etc. will be completed round the clock by suitable trademen (welder with suitable T&P, (including portable heating materials) -01, skilled mechanic of CHS-01, Plumber/Fitter -each 01, Supervisor-01 as per discretion of Engr-in-Charge. (iv) Job slip will be maintained by the Contractor Supervisor under supervision of concerned JE E/M CHS, suitable communication shall be maintained through JE incharge round the clock. (v) Any delay in attending complaint will be directly reported to higher authorities and suitable penalities will be incurred from the Contractor (Minimum Rs 1000/-Per Job). |
| 52 | S&F and replacement of Chilled/Hot Water Fan Coil Unit (FCU) vertical type Floor Mounting 2.5 TR capacity, complete all as specified and/or as directed by Engr-In-Charge. Make : Caryaire/Carrier/Voltas/Blue Star. |
| 53 | Supply and fixing and replacement of Chilled/Hot Water Fan coil Unit (FCU) Wall Mounting 2.0 TR Capacity complete all as specified and directed by Engr-In-Charge. Make : Carrier/Zeco or equvalent ISI Marked. |
| 54 | S&F in replacement of wall mounting (ECO Panel) convertor heater 2.5KW/Hrs Two heat output setup with auto control and LED temperature display. Dimension : width - 1200mm, height - 450mm, depth - 90mm with complete fixing accessories.Note : Old unserviceable convector heater to be deposited in MES Store Yard. |
| 55 | S&F in replacement of Soft Plug Top 6 Amps with indicator as per existing, complete all as specified and/or as directed by Engr-in-Charge. |
| 56 | Supply, connection and testing of thermal heater wires on water supply pipe lines (GI/MS/PPR) for heating of water through minimum 25 watt per meter in spiral/ straight line shape above outer diameter of pipe with aluminium tape insulation to preserve heat, fiber glass layer, second layer of aluminium tap to hold fiber glass by glass wool minimum 40mm thick with essential tapes, complete all as specified and/or as directed by Engr-in-Charge..Make: HTC Chromalox or equivalent as approved by GE. |
| 57 | S&F in replacement of lagging all around with 40/50 mm thick section bonded material wool of density 144 Kg/cum conforming to IS 9842 for heating calculation pipe line 40/50 mm over chicken wire mess, complete all as specified and/or as directed by Engr-in-Charge. Note : Retrieved glass wool to be disposed off by the Contractor. |
| 58 | S&F in replacement of lagging all around with 25/32 mm thick section bonded material wool of density 144 Kg/cum conforming to IS 9842 for heating calculation pipe line 40/50 mm over chicken wire mess, complete all as specified and/or as directed by Engr-in-Charge. Note : Retrieved glass wool to be disposed off by the Contractor. |
| 59 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth and getting out in hard/dense soil, complete all as specified and/or as directed by Engr-in-Charge. |
| 60 | Removing excavated material outside MD land n.exc 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point in soil, complete all as specified and/or as directed by Engr-in-Charge. |
| 61 | M&L for cleaning of MS under ground diesel tank of capacity 10000 ltr, firstly taking out diesel from tank by using suitable T&P and store into drum for re-use, secondly remove sludge completely from bottom of tank and destroy / bury in a safe place including painting the internal wall with two coats of black rubber emulsion paint and painting the complete tank from out side with two coats of synthetic enamel paint, complete all as specified and/or as directed by Engr-in-Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 01, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 22, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysAug 29, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender