Power Government Departments Closing in 1 days TDR #56786704

Tender For Establishment Of Modern Centralized Electrical Material Storage At Yamuna Bank Power House Colony, Agra

Issued by Government Departments · Agra, Uttar Pradesh
Tender Value
79.18 Lakhs
Estimated cost
Bid Submission
10 Aug 2026
1 days left
EMD
97500
Bank guarantee accepted
Document Fee
3540
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Agra → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Establishment Of Modern Centralized Electrical Material Storage At Yamuna Bank Power House Colony, Agra

BOQ

Name of Work:- ESTABLISHMENT OF MODERN CENTRALIZED ELECTRICAL MATERIAL STORAGE AT YAMUNA BANK POWER HOUSE COLONY, AGRA
Sl. No. Item Description
1Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: (DSR 2.1) All kinds of soil (DSR 2.1.1)
2Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. (DSR 2.6) All kinds of soil (DSR 2.6.1)
3Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. (DSR 2.8) All kinds of soil. (DSR 2.8.1)
4Excavating, supplying, stacking and filling of local earth (excluding royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. (DSR ) (DSR 2.25(a))
5Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. (DSR 2.28) All kinds of soil (DSR 2.28.1)
6Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. (DSR ) (DSR 2.31)
7Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared. (DSR ) (DSR 2.32)
8Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (DSR 4.1) 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 4.1.2)
9Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (DSR 4.1) 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 4.1.3)
10Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (DSR 4.1) 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) (DSR 4.1.8)
11Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: (DSR 4.2) 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 4.2.3)
12Providing and laying cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing. (DSR 4.4) 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 4.4.1)
13Providing and fixing up to floor five level precast cement concrete solid block, including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering, shuttering complete : (DSR 4.7) 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR 4.7.1)
14Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20mm nominal size derived from natural sources). (DSR ) (DSR 4.11)
15Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification. (DSR ) (DSR 4.12)
16Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (DSR 5.1) C (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 5.1.2)
17Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (DSR 5.1) 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 5.1.3)
18Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : (DSR 5.2) 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 5.2.2)
19Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR ) (DSR 5.3)
20Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete (DSR 4.3.1/DSR 5.9.1)
21Centering and shuttering including strutting, propping etc. and removal of form for Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. (DSR 4.3.2/DSR 5.9.2)
22Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Suspended floors, roofs, landings, balconies and access platform (DSR 5.9.3)
23Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Shelves (Cast in situ) (DSR 5.9.4)
24Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Lintels, beams, plinth beams, girders, bressumers and cantilevers (DSR 5.9.5)
25Centering and shuttering including strutting, propping etc. and removal of form for (DSR 4.3.3/DSR 5.9) Columns, Pillars, Piers, Abutments, Posts and Struts (DSR 4.3.3/DSR 5.9.6)
26Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like (DSR 5.9.15)
27Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Edges of slabs and breaks in floors and walls 5.9.16 Under 20 cm wide (DSR 5.9.16.1)
28Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Weather shade, Chajjas, corbels etc., including edges (DSR 5.9.19)
29Providing, hoisting and fixing up to floor five level precast reinforced cement concrete in small lintels not exceeding 1.5m clear span up to floor five level, including the cost of required centering, shuttering but , excluding the cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR ) (DSR 5.13)
30Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. (DSR 5.22) Thermo-Mechanically Treated bars of grade Fe-500D or more. (DSR 5.22.6)/(DSR 5.22A.6)
31Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections (DSR No. 5.30)
32Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: (DSR 6.1) Cement mortar 1:4 (1 cement : 4 coarse sand) (DSR 6.1.1)
33Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: (DSR 6.1) Cement mortar 1:6 (1 cement : 6 coarse sand) (DSR 6.1.2)
34Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : (DSR 6.4) Cement mortar 1:4 (1 cement : 4 coarse sand) (DSR 6.4.1)
35Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : (DSR 6.4) Cement mortar 1:6 (1 cement : 6 coarse sand) (DSR 6.4.2)
36Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. (DSR 6.13) Cement mortar 1:4 (1 cement :4 coarse sand) (DSR 6.13.2)
37Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. (DSR 8.2) Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble 8.2.1 Area of slab upto 0.50 sqm (DSR 8.2.1.1)
38(DSR 8.2) Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble 8.2.1 Area of slab over 0.50 sqm (DSR 8.2.1.2)
39Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. (DSR 8.2) Granite stone slab of colour black, Cherry/Ruby red 8.2.2 Area of slab upto 0.50 sqm (DSR 8.2.2.1)
40Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. (DSR 8.2) Granite stone slab of colour black, Cherry/Ruby red 8.2.2 Area of slab over 0.50 sqm (DSR 8.2.2.2)
41Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. (DSR 8.3) Marble work (DSR 8.3.1)
42Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. (DSR 8.3) Granite work (DSR 8.3.2)
43Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. (DSR ) (DSR 8.31)
44Extra for providing frosted glass panes 4 mm thick (weight not less than 10 kg per sqm) instead of ordinary float glass panes 4 mm thick (weight not less than 10 kg per sqm) in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured). (DSR ) (DSR 9.12)
45Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. (DSR 9.48) Fixed to steel windows by welding (DSR 9.48.1)
46Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. (DSR 9.48) Fixed to openings /wooden frames with rawl plugs screws etc. (DSR 9.48.2)
47Providing and fixing ISI marked IS:1341 oxidised M.S. pressed butt hinges with necessary screws etc. complete. (Copper oxidised as per IS 1378) (DSR 9.57) 125x65x2.12 mm (DSR 9.57.1)
48Providing and fixing ISI marked IS:1341 oxidised M.S. pressed butt hinges with necessary screws etc. complete. (Copper oxidised as per IS 1378) (DSR 9.57) 100x58x1.90 mm (DSR 9.57.2)
49Providing and fixing ISI marked IS:1341 oxidised M.S. pressed butt hinges with necessary screws etc. complete. (Copper oxidised as per IS 1378) (DSR 9.57) 75x47x1.70 mm (DSR 9.57.3)
50Providing and fixing ISI marked oxidised M.S. single acting spring hinges with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.59) 150 mm (DSR 9.59.1)
51Providing and fixing ISI marked oxidised M.S. single acting spring hinges with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.59) 125 mm (DSR 9.59.2)
52Providing and fixing ISI marked oxidised M.S. single acting spring hinges with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.59) 100 mm (DSR 9.59.3)
53Providing and fixing ISI marked IS: 453 oxidised M.S. double acting spring hinges with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.6) 150 mm (DSR 9.60.1)
54Providing and fixing ISI marked IS: 453 oxidised M.S. double acting spring hinges with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.6) 125 mm (DSR 9.60.2)
55Providing and fixing ISI marked IS: 453 oxidised M.S. double acting spring hinges with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.6) 100 mm (DSR 9.60.3)
56Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.62) 300x16 mm (DSR 9.62.1)
57Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.62) 250x16 mm (DSR 9.62.2)
58Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.63) 250x10 mm (DSR 9.63.1)
59Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.63) 200x10 mm (DSR 9.63.2)
60Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.63) 150x10 mm (DSR 9.63.3)
61Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.63) 100x10 mm (DSR 9.63.4)
62Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.66) 125 mm (DSR 9.66.1)
63Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.66) 100 mm (DSR 9.66.2)
64Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.66) 75 mm (DSR 9.66.3)
65Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (DSR ) (DSR 10.1)
66Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (DSR ) (DSR 10.2)
67Fixing standard steel glazed doors, windows and ventilators in walls, including fixing of float glass panes with glazing clips and special metal-sash putty of approved make, or metal beading with screws, (only steel windows, glass panes cut to size and glazing clips or metal beading with screws, shall be supplied by department free of cost. (DSR 10.1) Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) (DSR 10.10.1)
68Fixing standard steel glazed doors, windows and ventilators in walls, including fixing of float glass panes with glazing clips and special metal-sash putty of approved make, or metal beading with screws, (only steel windows, glass panes cut to size and glazing clips or metal beading with screws, shall be supplied by department free of cost. (DSR 10.1) Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) (DSR 10.10.2)
69Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. (DSR 10.15) Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) (DSR 10.15.1)
70Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. (DSR 10.15) Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) (DSR 10.15.2)
71Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. (DSR 10.16) Electric resistance or induction butt welded tubes (DSR 10.16.3)
72Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete. (DSR ) (DSR 10.17)
73Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. (DSR ) (DSR 10.18)
74Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. (DSR 10.25) In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works (DSR 10.25.2)
75Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. (DSR 10.26) M.S. tube (DSR 10.26.1)
76Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). (DSR ) (DSR 10.28)
77Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. (DSR 10.29) Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides (DSR 10.29.2)
78Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : (DSR 10.3) 4.0 mm thick glass panes (DSR 10.30.1)
79Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. (DSR ) (DSR 10.31)
80Brick on edge flooring with bricks of class designation 7.5 on a bed of 12 mm cement mortar, including filling the joints with same mortar, with common burnt clay non modular bricks: (DSR 11.1) 1:4 (1 cement : 4 coarse sand) (DSR 11.1.1)
81Brick on edge flooring with bricks of class designation 7.5 on a bed of 12 mm cement mortar, including filling the joints with same mortar, with common burnt clay non modular bricks: (DSR 11.1) 1:6 (1cement : 6 coarse sand) (DSR 11.1.2)
82Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks. (DSR ) (DSR 11.2)
83Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. (DSR 11.3) 40 mm thick with 20 mm nominal size stone aggregate (DSR 11.3.1)
84Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. (DSR 11.6) 18 mm thick (DSR 11.6.1)
85Cement concrete pavement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete. (DSR ) (DSR 11.7)
86Providing and fixing glass strips in joints of terrazo/ cement concrete floors. (DSR ) 40 mm wide and 4 mm thick (DSR 11.13.1)
87Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : (DSR 11.23) Udaipur green marble (DSR 11.23.5)
88Extra for pre finished nosing to treads of steps of marble stone. (DSR ) (DSR 11.24)
89Extra for marble stone flooring in treads of steps and risers using single length up to 2.00 metre. (DSR ) (DSR 11.25)
90Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : (DSR 11.26) 25 mm thick (DSR 11.26.1)
91Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. (DSR ) (DSR 11.27)
92Extra for Kota stone/ sand stone in treads of steps and risers using single length above normal size up to 2.00 metre. (DSR ) (DSR 11.32)
93Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. (DSR ) (DSR 11.37)
94Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. (DSR ) (DSR 11.37A)
95Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. (DSR 11.41) Size of Tile 600x600 mm (DSR 11.41.2)
96Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. (DSR 11.41A) Double charge vitrified tile polished finish of size 11.41A.1 Size of Tile 600 x 600 mm (DSR 11.41A.1.1)
97Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. (DSR 11.48) Size of Tile 600x600 mm (DSR 11.48.2)
98Deduct for not grouting the joints with white cement and matching pigment in the items of fixing of vitrified tiles. (DSR ) (DSR 11.50)
99Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : (DSR 12.21) In 75x75 mm deep chase (DSR 12.21.1)
100Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. (DSR ) (DSR 12.22)
101Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. (DSR 12.41) 110 mm diameter (DSR 12.41.2)
102Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. (DSR 12.42) Coupler 12.42.1 110 mm (DSR 12.42.1.2)
103Providing & fixing at all heights, levels and locations Mill finish Aluminium alloy roofing sheets of alloy IS designation 31500, temper Hx8 conforming to IS 737 and dimensions as per IS code 2676 with characteristics of good formability and corrosion resistance. The profile sheets shall be fixed to truss members in slope or required pitch or curvature with Hex cap headed self drilling/tapping Stainless steel screws M6, 50 mm long with 3 mm EPDM seal washer etc. all inclusive of labour, scaffolding, T&P and sundries etc. complete as per directions of the Engineer-In-Charge. (Cost of truss/frame work shall be paid separately). (DSR 12.64) 0.56 mm, Aluminium troughed profile with center to center pitch of 200 mm, depth of 32 mm, overall profile width1092 mm, cover width 1000mm. (DSR 12.64.1)
10412 mm cement plaster of mix :CEMENT PLASTER (IN COARSE SAND) (DSR 13.4) 1:4 (1 cement: 4 coarse sand) (DSR 13.4.1)
10512 mm cement plaster of mix :CEMENT PLASTER (IN COARSE SAND) (DSR 13.4) 1:6 (1 cement: 6 coarse sand) (DSR 13.4.2)
10615 mm cement plaster on rough side of single or half brick wall of mix:CEMENT PLASTER (IN COARSE SAND) (DSR 13.5) 1:4 (1 cement: 4 coarse sand) (DSR 13.5.1)
10715 mm cement plaster on rough side of single or half brick wall of mix:CEMENT PLASTER (IN COARSE SAND) (DSR 13.5) 1:6 (1 cement: 6 coarse sand) (DSR 13.5.2)
10812 mm cement plaster finished with a floating coat of neat cement of mix : (DSR 13.7) 1:4 (1 cement: 4 fine sand) (DSR 13.7.2)
1096 mm cement plaster of mix : (DSR 13.16) 1:3 (1 cement : 3 fine sand) (DSR 13.16.1)
110Neat cement punning. (DSR ) (DSR 13.18)
111Pebble dash plaster upto 10 m height above ground level with a mixture of washed pebble or crushed stone 6 mm to 12.5 mm nominal size, dashed over and including fresh plaster in two layers under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand) and top layer 10 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 10% finely grounded hydrated lime by volume of cement. (DSR ) (DSR 13.20)
112Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. (DSR ) (DSR 13.21)
113Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: (DSR 13.47) New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) (DSR 13.47.1)
114Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : (DSR 13.48) Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm (DSR 13.48.1)
115Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : (DSR 13.48) Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture (DSR 13.48.2)
116Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : (DSR 13.48) Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture (DSR 13.48.3)
117Finishing walls with ready mixed Premium acrylic emulsion paint (Company Depot Tinted) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade with silicon additives. (DSR 13.48A) New work (Two or more coats applied @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. (DSR 13.48A.1)
118Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : (DSR 13.62) Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture (DSR 13.62.1)
119Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (DSR ) (DSR 13.80)
120Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. (DSR 13.82) One coat (DSR 13.82.1)
121Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. (DSR 13.82) Two coats (DSR 13.82.2)
122Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. (DSR 13.83) One coat (DSR 13.83.1)
123Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. (DSR 13.83) Two coats (DSR 13.83.2)
124Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. (DSR 13.85) With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre (DSR 13.85.1)
125Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. (DSR 13.85) With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre (DSR 13.85.3)
126White washing with lime to give an even shade : (DSR 13.87) Old work (two or more coats) (DSR 13.87.1)
127White washing with lime to give an even shade : (DSR 13.87) Old work (one or more coats) (DSR 13.87.2)
128Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete (DSR ) (DSR 13.88)
129Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. (DSR ) (DSR 13.91)
130Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : (DSR 13.99) One or more coats on old work (DSR 13.99.1)
131Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade (DSR 13.112) Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface (DSR 13.112.1)
132Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade (DSR 13.112) Old work (one or more coats applied @ 0.83 ltr/10 sqm). (DSR 13.112.2)
133Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. (DSR 14.1) With cement mortar 1:4 (1cement: 4 coarse sand) (DSR 14.1.2)
134Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. (DSR 14.2) Door chowkhats (DSR 14.2.1)
135Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. (DSR 14.2) Window chowkhats (DSR 14.2.2)
136Fixing chowkhat in existing opening in brick/ RCC wall with dash fasteners/Chemical fasteners of appropriate size (3 nos on each vertical member of door chowkhat and 2 nos on each vertical member of window chowkhats), including Cost of dash fasteners/ chemical fastener. (DSR ) (DSR 14.3)
137Making the opening in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface i/c disposal of mulba/ rubbish to the nearest municipal dumping ground, all complete as per direction of Engineer-in-Charge. (DSR 14.4) For door/ window/ clerestory window (DSR 14.4.1)
138Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: (DSR 14.5) Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) (DSR 14.5.1)
139Renewing glass panes and refixing existing wooden fillets: (DSR 14.7) Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) (DSR 14.7.1)
140Supplying and fixing new wooden fillets wherever necessary: (DSR 14.8) Hollock wood fillets (DSR 14.8.2)
141Renewal of old putty of glass panes (length) (DSR ) (DSR 14.9)
142Refixing old glass panes with putty and nails (DSR ) (DSR 14.10)
143Fixing old glass panes with wooden fillets (excluding cost of fillets) (DSR ) (DSR 14.11)
144Providing and fixing 16 mm M.S. Fan clamps of standard shape and size in existing R.C.C. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. (DSR ) (DSR 14.12)
145Raking out joints in lime or cement mortar and preparing the surface for re-pointing or replastering, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. (DSR ) (DSR 14.17)
146Providing and fixing M.S. round or square bars with M.S. flats at required spacing in wooden frames of windows and clerestory windows. (DSR ) (DSR 14.29)
147Providing and fixing chromium plated brass butt hinges with necessary chromium plated brass screws etc. complete. (DSR 14.4) 125x70x4 mm (ordinary type) (DSR 14.40.1)
148Providing and fixing chromium plated brass butt hinges with necessary chromium plated brass screws etc. complete. (DSR 14.4) 100x70x4 mm (ordinary type) (DSR 14.40.2)
149Providing and fixing chromium plated brass butt hinges with necessary chromium plated brass screws etc. complete. (DSR 14.4) 75x65x4 mm (heavy type) (DSR 14.40.3)
150Providing and fixing chromium plated brass butt hinges with necessary chromium plated brass screws etc. complete. (DSR 14.4) 75x40x2.5 mm (ordinary type) (DSR 14.40.4)
151Providing and fixing chromium plated brass butt hinges with necessary chromium plated brass screws etc. complete. (DSR 14.4) 50x40x2.5 mm (ordinary type) (DSR 14.40.5)
152Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre) (if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) (DSR ) (DSR 14.75A)
153Cleaning and desilting of gully trap chamber, including removal of rubbish mixed with earth etc. and disposal of same, all as per the direction of Engineer-in-charge. (DSR ) (DSR 14.76)
154Cleaning of chocked sewer line by diesel running vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleaning machine fitted with pump having 4000 litres suction capacity and 6000 litres water jetting tank capacity including skilled operator, supervising engineer etc. for cleaning and partial desilting of manholes and dechocking of sewer lines. Dechocking and flushing of sewer line from one manhole to another by high pressure jetting system of 2200 PSI for sewer line from 150mm dia upto 300mm (DSR ) (DSR 14.77)
155Disconnecting damaged overhead/terrace PVC water storage tank of any size from water supply line and removing from the terrace including shifting at ground level as per direction of Engineer-in-charge. (DSR ) (DSR 14.79)
156Providing & fixing White vitreous china water closet squatting pan (Indian type) along with \\"S\\" or \\"P\\" trap including dismantling of old WC seat and \\"S\\" or \\"P\\" trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge. (DSR 14.8) Orissa pattern W.C Pan of size 580x440 mm (DSR 14.80.2)
157Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. (DSR ) (DSR 15.60)
158Brick edging in full brick width and half brick depth including excavation, refilling and disposal of surplus earth lead upto 50 metres. (DSR 16.7) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR 16.7.1)
159Brick edging laid lengthwise with half brick depth including excavation, refilling and disposal of surplus earth lead upto 50 metres : (DSR 16.8) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR 16.8.1)
160Supplying at site : (DSR 16.15) Welded steel wire fabric of required width having rectangular mesh painted with two or more coats of enamel paint of approved shade over a coat of primer (Priming & Painting to be paid for separately). (DSR 16.15.2)
161Fencing with angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100 m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately). Payment to be made per metre cost of total length of barbed wire used. (DSR 16.18) With G.I. barbed wire (DSR 16.18.1)
162Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete. (DSR ) (DSR 16.19)
163Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) in pavements, laid to required slope and camber in panels as required including consolidation finishing and tamping complete. (DSR ) (DSR 16.42)
164Extra for providing and mixing hardening compound of approved quality as per manufacturer's specification in cement concrete. (DSR ) (DSR 16.44)
165Providing and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners, all complete as per direction of the Engineer-in-Charge. (Pre-moulded joint fillers shall be made of bitumen hot sealing compound impregnated fibre board having impregnation more than 35%, conforming to IS:1838 for fibre board and IS: 1834 for hot sealing bitumen compound grade A.) (DSR ) (DSR 16.45)
166Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) (DSR ) (DSR 16.53)
167Providing and laying 75 mm thick compacted bed of dry brick aggregate of 40 mm thick nominal size including spreading, well ramming, consolidating and grouting with jamuna sand, including finishing smooth etc. complete as per direction of Engineer-in-charge. (DSR ) (DSR 16.64)
168Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. (DSR ) (DSR 16.68)
169Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. (DSR 16.7) Made of G.I. wire of dia 4 mm (DSR 16.70.1)
170Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge. (The panel shuttering work shall be paid for separately).(Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately). (DSR ) (DSR 16.75)
171Deduct for using of M-20 grade concrete instead of M-25 grade concrete in C.C. pavement. (DSR ) (DSR 16.76)
172Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. (DSR 16.78) With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 (DSR 16.78.2)
173Providing and laying matt finished vitrified tile of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. (DSR ) (DSR 16.89)
174Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. (DSR 16.91) 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. (DSR 16.91.1)
175Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. (DSR 16.91) 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. (DSR 16.91.2)
176Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: (DSR 17.1) White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests (DSR 17.1.1)
177Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: (DSR 17.7) White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap (DSR 17.7.4)
178Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. (DSR 17.18) 10 litre capacity - White (DSR 17.18.1)
179Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings : (DSR 17.25) Flat back wash basin of size 550x400 mm (DSR 17.25.2)
180Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. (DSR 17.28) Semi rigid pipe 17.28.1 32 mm dia (DSR 17.28.1.1)
181Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. (DSR 17.28) Flexible pipe 17.28.2 32 mm dia (DSR 17.28.2.1)
182Providing and fixing 100 mm sand cast Iron grating for gully trap. (DSR ) (DSR 17.29)
183Providing and fixing in position 25 mm diameter mosquito proof coupling of approved municipal design. (DSR ) (DSR 17.30)
184Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. (DSR ) (DSR 17.31)
185Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. (DSR ) (DSR 17.72)
186Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.(Concealed work, including cutting chases and making good the walls etc.) (DSR 18.8) 20 mm nominal dia Pipes (DSR 18.8.2)
187Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.(Concealed work, including cutting chases and making good the walls etc.) (DSR 18.8) 25 mm nominal dia Pipes (DSR 18.8.3)
188Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) (DSR 18.9) 15 mm nominal dia Pipes (DSR 18.9.1)
189Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) (DSR 18.9) 20 mm nominal dia Pipes (DSR 18.9.2)
190Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) (DSR 18.9) 25 mm nominal dia Pipes (DSR 18.9.3)
191Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) (DSR 18.9) 32 mm nominal dia Pipes (DSR 18.9.4)
192Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : (DSR 18.17) 25 mm nominal bore (DSR 18.17.1)
193Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : (DSR 18.17) 20 mm nominal bore (DSR 18.17.1A)
194Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : (DSR 18.17) 32 mm nominal bore. (DSR 18.17.2)
195Providing and fixing gun metal non- return valve of approved quality (screwed end) : (DSR 18.19) 25 mm nominal bore 18.19.1 Horizontal (DSR 18.19.1.1)
196Providing and fixing gun metal non- return valve of approved quality (screwed end) : (DSR 18.19) 25 mm nominal bore 18.19.1 Vertical (DSR 18.19.1.2)
197Providing and fixing gun metal non- return valve of approved quality (screwed end) : (DSR 18.19) 32 mm nominal bore 18.19.2 Horizontal (DSR 18.19.2.1)
198Providing and fixing gun metal non- return valve of approved quality (screwed end) : (DSR 18.19) 32 mm nominal bore 18.19.2 Vertical (DSR 18.19.2.2)
199Providing and fixing uplasticised PVC connection pipe with brass unions : (DSR 18.21) 30 cm length 18.21.1 15 mm nominal bore (DSR 18.21.1.1)
200Providing and fixing uplasticised PVC connection pipe with brass unions : (DSR 18.21) 30 cm length 18.21.1 20 mm nominal bore (DSR 18.21.1.2)
201Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (DSR ) (DSR 18.48)
202Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : (DSR 18.49) 15 mm nominal bore (DSR 18.49.1)
203Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. (DSR 18.5) 15 mm nominal bore (DSR 18.50.1)
204Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. (DSR 18.51) 15 mm nominal bore (DSR 18.51.1)
205Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. (DSR 18.52) 15 mm nominal bore (DSR 18.52.1)
206Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 (DSR 18.53) 15mm nominal bore (DSR 18.53.1)
207Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. (DSR ) (DSR 18.53A)
208Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. (DSR 18.62) 20 mm nominal bore, 120 mm long, weighing not less than 198 gms (DSR 18.62.2)
209Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. (DSR ) (DSR 18.65)
210Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. Group A (DSR-22 EM Code: 1.8.1)
211Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A (DSR-22 EM Code: 1.10.1)
212Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. b) 2 X2.5 sq. mm + 1X2.5 sq. mm earth wire (DSR-22 EM Code: 1.14.2)
213Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. C)2 X 4 sq. mm + 1 X 4 sq. mm earth wire (DSR-22 EM Code: 1.14.3)
214Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. c)2 X 6 sq. mm + 1 X 6 sq. mm earth wire (DSR-22 EM Code: 1.14.4)
215Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. Group B (DSR-22 EM Code: 1.15.2)
216Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. a)1 x1.5 sq. mm (DSR-22 EM Code: 1.17.1)
217Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.b)2x1.5 sq. mm (DSR-22 EM Code: 1.17.2)
218Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.c)3x1.5 sq. mm (DSR-22 EM Code: 1.17.3)
219Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.d)4x1.5 sq.mm (DSR-22 EM Code: 1.17.4)
220Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.k)2x2.5 sq.mm (DSR-22 EM Code: 1.17.11)
221Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3x2.5 sq.mm (DSR-22 EM Code: 1.17.12)
222Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.2 x4 sq.mm (DSR-22 EM Code: 1.17.20)
223Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3x4 sq.mm (DSR-22 EM Code: 1.17.21)
224Supplying and fixing 6way, Double door, single pole and neutral, sheet steel, MCB distribution board, 240V, on Surface/recess,complete with tinned copper bus bar, heutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But with MCB/RCCB/Isolator) (DSR EM 2022 2.3.1)
225Supplying and fixing 5 amps to 32 amps rating,Single pole, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (DSR EM 2022 2.10.1)
226Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm (DSR-22 EM Code: 1.21.1)
227Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm (DSR-22 EM Code: 1.21.2)
228Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 32 mm (DSR-22 EM Code: 1.21.3)
229Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 40 mm (DSR-22 EM Code: 1.21.4)
230Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 5/6 amps switch (DSR-22 EM Code: 1.23.1)
231Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.2 way 5/6 A switch (DSR-22 EM Code: 1.23.2)
232Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 15/16 A switch (DSR-22 EM Code: 1.23.3)
233Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 3 pin 5/6 A socket outlet (DSR-22 EM Code: 1.23.4)
234Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 6 pin 15/16 A socket outlet (DSR-22 EM Code: 1.23.5)
235Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch (DSR-22 EM Code: 1.24.1)
236Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 2 way 5/6 A switch (DSR-22 EM Code: 1.24.2)
237Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 A switch (DSR-22 EM Code: 1.24.3)
238Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 A socket outlet (DSR-22 EM Code: 1.24.4)
239Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 A socket outlet (DSR-22 EM Code: 1.24.5)
240Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. (DSR-22 EM Code: 1.25)
241Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. (DSR-22 EM Code: 1.26)
242Supplying and fixing following size/ modules, Gl box along with modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm) (DSR-22 EM Code: 1.27.1)
243Supplying and fixing following size/ modules, Gl box along with modular base & cover plate for modular switches in recess etc. as required. 3 Module (100mmX75mm) (DSR-22 EM Code: 1.27.2)
244Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 1 or 2 Module (DSR-22 EM Code: 1.28.1)
245Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 3 Module (DSR-22 EM Code: 1.28.2)
246Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required. (DSR-22 EM Code: 1.29)
247Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required. (DSR-22 EM Code: 1.30)
248Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. (DSR-22 EM Code: 1.31)
249Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. (DSR-22 EM Code: 1.32)
250Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. (DSR-22 EM Code: 1.33)
251Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. (DSR-22 EM Code: 1.44)
252Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Up to 450 mm sweep (DSR-22 EM Code: 1.50.1)
253Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/lsolator) 4 way (4 + 12), Double door (DSR-22 EM Code: 2.4.1)
254Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4 + 12), Double door (DSR-22 EM Code: 2.5.1)
255Supplying and fixing following rating, double pole, the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A (DSR-22 EM Code: 2.12.1)
256Supplying and fixing following rating, double pole, the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A (DSR-22 EM Code: 2.12.2)
257Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A (DSR-22 EM Code: 2.13.2)
258Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 100 A (DSR-22 EM Code: 2.13.3)
259Providing and fixing 25 mm X 5 mm G.l. strip on surface or in recess for connections etc. as required. (DSR-22 EM Code: 5.15)
260Providing and fixing 6 SWG dia G.l. wire on surface or in recess for loop earthing as required. (DSR-22 EM Code: 5.16)
261Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. (DSR-22 EM Code: 17.5.4)
262Supply, Installation, Testing and Commissioning of 1200 mm sweep,BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required (DSR EM 2022 19.1)
263Concrete with 4cm gauge I class brick ballast, coarse sand (F.M. 1.8 to 2.5) and cement in proportion of 12:6:1 in foundations and under floors including supply of all materials, labour and tools and plants etc. required for proper completion. (CSI No.5.01 )
264Concrete work with 40 mm gauge brick ballast obtained from breaking brick bats (brick bats supplied by the department free of cost) in proportion of 12:6:1 as in CSI no. 5.01 including cost of all labour, materials, T&P etc required for proper completion of work. (CSI No. 5.20)
265Brick work in foundation & plinth with old dismantled bricks (supplied by department free of cost) and coarse sand of F.M. 1.8 to 2.5 mortar in 1:6 including supply of all other materials, labour, removing mortar & cleaning of old & used bricks,T&P etc complete. (CSI No. 6.18)
266Brick work in Super structure with old dismantled bricks (supplied by department free of cost) and coarse sand of F.M. 1.8 to 2.5 mortar in 1:6 including supply of all other materials, labour, removing mortar & cleaning of old & used bricks,T&P etc complete. (CSI No. 6.19)
267S/F welded wire mesh size 75x25mm and rectangular made out of 10 SWG over M.S. angle frame with M.S. flat welded as required including cost of drilling holes, washer welding etc as required including cost of all material, labour and T&P etc. required for proper completion of work . exept cost of M.S angle and flat. (NSI Based on CSI No. 9.22 Based NSI)
268Supply & installation of electrical control panel of L&T / Havells or equivalent make for 1.5/2.00 pump set single phase submersible pump / pumpset containing contractor relay condenser. (NSI Based on CSI No. 19.31b)
269Supply & Installation of 1.5 HP outlet 40mm dia. or more, Head 71/36, Discharge 2000/6000 LPH submersible pump of K.S.B/ CALAMA. or eqt. make including cost of labour, T&P and material required for completion of work. (NSI Based on CSI No. 19.32b)
270Supply & Installation of 2.00 HP outlet 40mm dia. or more, Head 89/45, Discharge 2000/6000 LPH submersible pump of K.S.B/ CALAMA. or eqt. make including cost of labour, T&P and material required for completion of work. (NSI Based on CSI No. 19.32c)
271Supply & installation of electrical control panel of L&T / Havells or equivalent make for submersible pump / pumpset containing contractor relay condenser.e) for 7.5 H.P pump set three phase (CSI No. 19.31e)
272Supply & Installation of submersible pump of K.S.B/ CALAMA. or eqt. make including cost of labour, T&P and material required for completion of work. f) three phase 7.5 HP outlet 65 mm dia. or more, Head 57/46, Discharge 24000/30000 LPH(CSI No. 19.32f)
273Supply and fixing of submersible cable Havels or equivalent make, for submersible pump complete in all respect. c) 4.0 mm2 for pump above 3 HP and up to 7.5 H.P. (CSI No. 19.33c)
274Supply and fixing of 2.5 mm2 for pump above 1 HP and up to 3 HP submersible cable Havels or equivalent make, for submersible pump complete in all respect. (NSI Based on CSI No. 19.33b)
275Supply & fixing of steel wire rope for submersible pump including cost of labour, T&P and material required for completion of work. (NSI Based on CSI No. 19.34)
276Extraction of defective VT submersible pumps and motor with 60\\" x 90\\" column pipe and then lowering of the repaired pump and motor with pipe and testing the same including checking main cut-out fuse and operation of Tube well for 24 hours fo rits smooth working with all cost of materials,labour and T&P etc required for the proper completion of the work.(NSI Based on CSI No. 20.28)
277Rewinding of burnt ceiling fan with approved copper wire including cost of all materials, labour and T&P etc. complete (Burnt wire will not be taken back.)(NSI Based on CSI No. 22.08)
278Supply and replacing of burnt and damaged condenser of ceiling fan of approved quality including all materials,labour and T&P etc.(NSI Based on CSI No. 22.09)
279Taking off the defective ceiling fan from position & re hanging after receiving the repaired fan and proper connection etc.(NSI Based on CSI No. 22.10)
280Providing and laying SWR, PVC ( Finolex or equivalent ) pipe including cost of excavation, C.C etc including its jointing and connection, all materials, labour and T&P etc. required for proper completion of the work. (CSI No. 27.29 c) 110 mm dia
281Supply and Fixing of 5 blade Exhaust fan ventile air dx 225 mm of Havells or equivalent make including all material, T&P etc required for proper completion of work as approved by engineer in charge.(CSI No. 28.38)
282Supply and fixing of LED Tube Light batten fitting suitable for up to 1 X 22 watt LED tube light on surface complete in all respect. 2018 PWD 1413(A) CAT AA
283S/F of LED Bulb 9Watt bajaj or equivalent make as approved sample and make as per direction of Engineer in charge (NSI)
284Providing and fixing 15 mm thick Industrial tiles size 600 x 600 mm to of Johnson Endura Meteor or approved make and colour using in different sizes (thickness to be specified by the manufacturer) conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete(NSI)
285Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. (NSI)
286Precast Cement Concrete Septick tank 0.900 m dia pipe with cover with accessories & cover (NSI)
287Providing & fixing at all heights, levels and locations 0.47 to 0.52 mm colour finish Aluminium alloy roofing Tata Durashine or equivalent make sheets of alloy IS designation 31500, temper Hx8 conforming to IS 737 and dimensions as per IS code 2676 with characteristics of good formability and corrosion resistance. The profile sheets shall be fixed to truss members in slope or required pitch or curvature with Hex cap headed self drilling/tapping Stainless steel screws M6, 50 mm long with 3 mm EPDM seal washer etc. all inclusive of labour, scaffolding, T&P and sundries etc. complete as per directions of the Engineer-In-Charge. (Cost of truss/frame work shall be paid separately)(NSI)
288Providing and fixing of Pre-coated colour/ mill finish Precoated/mill finish aluminium Gutter (600 mm over all girth) Accessories in 0.47 to 0.52 mm thickness ,Alloy 31500 (IS designation) [Aluminium Alloy (AA) 3004 (ISO designation)] For color, coating shall be 5-7 microns epoxy primer on both sides of the sheet and polyester top coat 15-18 microns, using self drilling/ tapping SS screws of size 6 x 50mm with 3mm thick EPDM seal and SS plain washercomplete : Precoated/mill finish aluminium Ridges plain (500- 600mm)(NSI)
289Refixing at all heights, levels and locations roofing Sheet The profile sheets shall be fixed to truss members in slope or required pitch or curvature with Hex cap headed self drilling/tapping Stainless steel screws M6, 50 mm long with 3 mm EPDM seal washer etc. all inclusive of labour, scaffolding, T&P and sundries etc. complete as per directions of the Engineer-In-Charge. (Cost of truss/frame work shall be paid separately & Roofing sheet provide by Department) (NSI)
290Water proofing treatment over Roof, wall, Chajjas, Balcony etc. with Engineer Plus 7 layer waterproofing system at leakage, seepage area consisting of Surface preparation roughening of surface, opening of cracks in V groove in size of 5 mm to 10 mm width, Back filling of cracks with SBR Latex, 2 layer Spraying Mixture of Aquasil-99 and Aquaprime-99 (Take 20 liter clean water+ 1 liter Engineer Plus Aquasil-99 + 2 liter. Engineer Plus Aquaprime-99 in proportion 20:1:2 This solution should not sprayed over more than 40 sqm area, 3rd Laying 90GSM fiber glass mesh with proper overlap, 4th coat of brushable mortar prepared with Engineer Plus Aquaprime-99, water & cement (Aquaprime -99 @ 0.45 kg per sqm, water @ 0.45 kg per sqm & cement @0.68 kg per sqm.) in the proportion of 1:1:1.5 by weight, After 4th coat allow the coating to air cure for minimum four hours, after 4 hours interval apply, 2 coat of Flexicoat-99 mixed with Water (Flexicoat-99 @0.33 kg/sqm, water @0.66 Kg per Sqm) in the proportion of 1:2 by weight in 4 hours interval. After 6th coat allow the coating to air cure for minimum 4 hours. After 4 hours interval apply, 7th coat of Engineer Plus smartcoat-99 (Smartcoat-99 @ 0.45 Ltr/sqm & water @ 1.35Ltr/sqm in the proportion of 1:3). The surface will dry within 2 hours and surface would be fully water proof and usable after a period of 24 hours and the final appearance of the coating will be gray/milky white. The rates are included the cost of all chemicals, labours, and Required T&P for Proper completion of Work.NSI
291Providing and lowering of 32 mm dia. uPVC column pipe Finolex/Ashirwad or equivalent make with column coupling socket etc. including cutting the pipe of required length, proper jointing the same including cost of all materials, labour, T&P etc required for proper completion of work.
292Providing and lowering of 40 mm dia. uPVC column pipe Finolex/Ashirwad or equivalent make with column coupling socket etc. including cutting the pipe of required length, proper jointing the same including cost of all materials, labour, T&P etc required for proper completion of work. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56786704
AUTHORITY Government Departments
TENDER VALUE 79.18 Lakhs
LAST DATE 10-08-2026
Authority
Authority Name Dakshinanchal Vidyut Vitran Nigam Limited
Work Description Tender for Establishment Of Modern Centralized Electrical Material Storage At Yamuna Bank Power House Colony, Agra
Basic Detail
Tender No 141/ECC(D)Ag/2026-27
Bidding Type Tender
Location
City Agra
State Uttar Pradesh
Key Dates
Publish Date 01 Aug 2026
Submission Date 10 Aug 2026
Open Date 11 Aug 2026
Finance
Tender Value 79.18 Lakhs
Tender Fee 3540
EMD 97500
Exemption Not Available
Document List
492a6443-490e-43af-bfac-dc0c6c319af4.html
BOQ_2205657.xls
TenderDocuments.rar
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 01, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 10, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day
Aug 11, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
html

492a6443-490e-43af-bfac-dc0c6c319af4.html

xls

BOQ_2205657.xls

rar

TenderDocuments.rar

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders