Tender For Electrical Works At Sci Integration
Tender Value
1.48 Crore
Estimated cost
Bid Submission
24 Aug 2026
23 days left
EMD
3 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kamrup Metro → Assam
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Electrical Works At Sci Integration
BOQ
| Sl. No. | Item Description |
| 1 | Electrical Works at SCI , Ghy BOQ for SCI Electrical Integration works from the OLD and New Hospitals Sl.No Description of Work Unit Quantity Approved Make Basic rate GST Amount |
| 2 | Unloading and installation of an indoor-type 1600 KVA Cast Resin dry-type distribution transformer (supplied by the client) along with RTCC panel (supplied by the client), including associated connections and testing. Commissioning support to be provided in coordination with the OEM, with the testing engineer arranged by the client. 1600 KVA Cast Resin indoor dry-type distribution Transformer Nos 1.0 0.0 |
| 3 | Unloading and installation of an indoor-type 1250 KVA Cast Resin dry-type distribution transformer (supplied by the client) along with RTCC panel (supplied by the client), including associated connections and testing. Commissioning support to be provided in coordination with the OEM, with the testing engineer arranged by the client. 1250 KVA Cast Resin indoor dry type distribution Transformer Nos. 1.0 0.0 |
| 4 | Supply, installation, testing and commissioning of HT cable, 3‑phase, 33kV grade, laid in Hume pipe or cable trench, complete with all required accessories. Cable Size 33kV (unearthed) grade, 3C × 300 sqmm XLPE insulated, aluminium conductor, armoured type. |
| 5 | Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 33 KV grade as required :33kV (Unearthed) grade, 3c x 300 sqmm XLPE Al. Ar. cable |
| 6 | Unloading, shifting, and Erection of 33 kV, 630 A, 26.3 kA/1 sec indoor switchboard (SWBD) outgoing panels – 3 nos. (supplied by the client) into position for connection with the Main HT Panel. Retrofitting and final connection to the HT Panel will be carried out by the OEM; however, coordination and assistance to the OEM shall be within the bidder’s scope. |
| 7 | Unloading, shifting, and Erection of the LT Panel-2500A I/C (supplied by the client) into position for connection with the existing Main LT Panel. Retrofitting and final connection to the LT Panel will be carried out by the OEM; however, coordination and assistance to the OEM shall be within the bidder’s scope. |
| 8 | Unloading, shifting, and placement of the Hybrid type APFC Panel (supplied by the client) into position for connection with the existing Main LT Panel. Retrofitting and final connection to the LT Panel will be carried out by the OEM; however, coordination and assistance to the OEM shall be within the bidder’s scope. EARTHING Supply, Installation, testing and commissioning of earth electrode as per IS 3043-1987. The rate shall be for complete work like excavation, back filling with salt and charcoal, ramming and consolidation , brick work , cast iron heavy duty cover slab etc. All earth station to be treated with bentonite powder and rich clay soil to obtain combined earth resistance with in 1 ohms as per requirements of local authorities. This shall also have chamber with funnel arrangement for watering. Nutech Products, Mahavir Industrial Corporation, Pranav Energy. |
| 9 | 600x600x3mm thick Cu plate electrode. |
| 10 | 65mm internal dia,3 m long GI pipe electrode Earthing the installation with the following sizes of earth wires . Rate shall be inclusive of spacer clamp for main earth flat , suitable clamping with M.S. flats for earth wires etc.,including terminal crimping type sockets , bolts and washers ,etc. required for the complete job. Nutech Products, Mahavir Industrial Corporation, Pranav Energy. GI Earth Strips |
| 11 | 25x6mm GI strip with SMS spouts isulator for every 0.75m interval Copper Earth strips |
| 12 | 75x10mm Cu. strip with SMS spouts insulator for every 0.75m interval |
| 13 | Chiller ISOLATION PANEL (Short circuit rating - 50 KA/ Sec) - Outdoor Type (IP 55) Supply, installation, testing and commissioning of isolator panel, which shall be fabricated out of galvanised MS angle iron frame/ 'C' channel and 14/16 SWG galvanised sheet steel with weather-proof cover. The arrangement shall be vermin-proof and waterproof. The bottom skirt of the panel shall be fabricated out of 100x50x5mm MS angle frame, duly galvanised with 4 nos. 12x100 mm grounding bolts and as per follows. Panel shall be fabricated with top Cable entry for incoming, Cable entry at the Bottom and with the provision of a 3 mm thick Hylam sheet shall be used to shroud all live parts and a double earthing provision shall be given as per IS codes. EAP/YALAVARTHI/CPRI approved vendor Cost shall also include constructing a platform to place the isolator panel near the chiller using RCC and associated civil works, etc. 400 Amps TPN ISOLATOR Set 1.0 0.0 MISCELLANEOUS ITEMS |
| 14 | Supply and installation of the following equipments. 6 mm thick, 900mm width Non-skid rubber mat for 33KV grade. (High voltage PVC insulating mats confirming to new specification IS:15652-2006 should be of Pastable type, Permanently fixed, smooth trolley movement, moisture proof, Fire retardent, no adverse effect fo acids, alkalies and transformer oil.) Mtrs 30.0 0.0 LT CABLES FRLS CABLE - Extruded PVC Inner Sheathed and Extruded FRLS-PVC Outer sheatehed UNIVERSAL/ RPG/ POLYCAB / KEI/HAVELLS |
| 15 | Supply, laying, dressing, testing and commissioning of the following sizes of 1.1 KV grade XLPE insulated FRLS with GI strip armoured aluminum conductor cable and armoured/Flexible Copper conductor cable, to be laid in direct ground/ Hume pipe, duct or trench using cable tray / cable rack with proper clamping ,cable identification tags etc. The rate shall exclude cable tray/trench/rack and Hume pipes. The cost shall inculude Providing cable Route markers at interval of 200meters and at turning points of the cable Armoured Aluminium Cables |
| 16 | 3.5 x 300 sq.mm |
| 17 | 3.5 x 240 sq.mm |
| 18 | 3.5 x 70 sq.mm Armoured Control Cables UNIVERSAL/ RPG/ POLYCAB / KEI/HAVELLS |
| 19 | 12C x 2.5 sq.mm copper cable |
| 20 | 4C x 2.5 sq.mm copper cable |
| 21 | FRLS CABLE - Extruded PVC Inner Sheathed and Extruded FRLS-PVC Outer sheatehed End Termination End termination for 1.1KV cables with Double compression type brass cable gland and heavy duty tinned Cu. Socket for copper cable and Al.sockets for Aluminum cable. Rate shall be inclusive of all sundry materials like adhesive tape, PVC sleeves, bolts and nuts, washers etc.including plugging unused holes. The cost shall include suitable size Gland Earth Clip for earthing of Cable Gland through 8SWG GI wire Armoured Aluminium Cables |
| 22 | 3.5 x 300 sq.mm |
| 23 | 3.5 x 240 sq.mm |
| 24 | 3.5 x 70 sq.mm CABLE TRAYS & RACEWAY Any reputed Make -HDG |
| 25 | Supply & installation of Galvanised Ladder type cable trays fabricated out of minimum 14 'SWG MS sheet steel. The rate shall be inclusive of all necessary cross arms, couplers, tee,'bends and all other fixing accessories, angles, supporting structures etc. duly painted to 'complete the cable distribution system. The rungs shall be at the interval of 300mm. The 'angle supports shall be provided at an interval of 1500mm for cable trays upto and 'including 600mm wide and the interval shall be 1000mm for cable trays above 600mm 'wide. The angle supports are required at one side for the trays upto and including 600mm 'wide and both sides supports for above 600mm wide. |
| 26 | 450mm wide 75mm depth |
| 27 | 750mm wide 75mm depth |
| 28 | Supply & installation of Galvanised Perforated type cable trays fabricated out of minimum 14 SWG MS sheet steel. The rate shall be inclusive of all necessary cross arms, couplers, 'tee, bends and all other fixing accessories, angles, supporting structures etc. duly painted to 'complete the cable distribution system. The angle supports shall be provided at an interval 'of 1500mm for cable trays upto and including 600mm wide and the interval shall be '1000mm for cable trays above 600mm wide. The angle supports are required at one side 'for the trays upto and including 600mm wide and both sides supports for above 600mm 'wide. 150mm wide 50mm depth Mtrs. 200.0 0.0 |
| 29 | Cable Tray Earthing 50x6mm G.I earth strip welded or fixed with bolt nut for 750mm(W) and above size of cable tray Mtrs. 450.0 0.0 EXTERNAL LIGHTING FIXTURES & FAÇADE LIGHT FIXTURES |
| 30 | External LED Light Fixtures All the Light Fixtures shall have in built harmonic suppression features All the Light Fixture shall comply to the below requirments a) Power factor >0.95 b) Lumen / watt - Greater than 100 (including driver loss) 126W High Power LED street light luminaire (Cool White ) with integral driver IP 65 simialr to Philips Make BRP 322 LED 128 CW HE MR FG S3 XT Nos. 5.0 WIPRO/Philips/Havells 0.0 Supply and laying of following sizes of Electrical Resistance welded (ERW) MS conduit to be / surface mounted with necessary accessories like bends, couplers GI sadles at every 600mm etc. The rate shall include for metal junction boxes of suitable sizes at regular intervals. |
| 31 | 20mm dia 1.6mm thick MS conduit CCTV System HONEYWELL/ SIEMENS /PELCO |
| 32 | Day/Night True IP Full HD Infrared Bullet Camera SITC of IP network true day/night IP65 Bullet PAL Color Camera with min 1/3\\" Progressive scan CMOS/ Progressive scan CCD /CMOS - min 2 MP resolution image sensor, with min one H.264 stream for recording & one MPEG 4/MJPEG stream for live viewing. It shall have the capability to deliver SITC of two independenat video streams and shall be possible to set independant FPS (30 fps for M-JPEG and 30 fps for H.264) & Compression selection (QCIF to 720P) for each stream with built in 2.8 - 12 mm lens, Motorized very focal auto DC iris lens with built in WDR (120DB), HLC & automatic back light compensation circuitry for varying light levels and sensitivity of min 0.3 lux with IR illuminator OFF & 0 Lux with IR illuminator ON (50mts IR distance) and sensitivity of min 0.5 lux at 40/50 IRE and with POE connectivity and also with external power supply with built in WEB Browzer. The camer should be UL listed, ONVIF Nos 12.0 HONEYWELL/ SIEMENS /PELCO 0.0 |
| 33 | SITC of 16 Channel NVR |
| 34 | SITC of Cat-6 Cable |
| 35 | Heightening of RMU & Consumer HT Panel Pedestals, including Re fixing of Panels with Cable Disconnection and Subsequent Re energisationSequence and scope of Work:1. Disconnect the live cables of the RMU panel and energise the system through the RMU panel.2. After bypassing the RMU panel, construct 600 mm pedestals above the existing level, followed by heightening of the pedestals.3. Disconnect the live electrical cables of the consumer and energise the system through the consumer panel.4. After bypassing the consumer panel, construct 600 mm pedestals above the existing level, followed by heightening of the pedestals.5. After completing pedestal heightening and panel fixing, re-energise the system to restore it to its original operational state. Total cost with GST 0.0 0.0 Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 01, 2026
11:30 IST
Tender Published
Tender notice published.
TodayAug 24, 2026
17:00 IST