Tender For Special Repair To P-03, P-05 And P-59 At Af Station Highgrounds.
Tender Overview
Project Description
Tender for Special Repair To P-03, P-05 And P-59 At Af Station Highgrounds.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 20-Aug-2026 | BOQ Corrigendum | BOQ | 31-Aug-2026 |
| 2 | 20-Aug-2026 | Date Corrigendum | Date | 31-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Building Work |
| 2 | Dismantaling brick/PCC tiles or terracing tiles single layer in roof complete. |
| 3 | Taking down existing bitumen felt roof treatment,chiseling existing bitumineous coating and removing out side the MoD land complete all as specified. |
| 4 | Taking down cement plaster or cement lime plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc of any description and any position, including removing the debris from the site to a designated point by the civil administration complete all as specified and directed by Engineer-in-Charge. |
| 5 | Demolition of cement concrete as in roof pading, any thickness and any descrition upto RCC roof slab by mechanical means,cleaning the surface including flashings and junction of parapers, etc with wire brushes and water to the entire satisfaction of Engineer -in -Charge including removing the debris from the site to a designated point by the civil administration complete all as specified and directed by Engineer-in-Charge. |
| 6 | Roughning surfaces of old concrete sufrace of floor/roof by picking, sweeping clean and washing down with water to remove dust etc and brushing neat cement slurry with 3.0 Kg of cement per sqm complete all as specified and directed. |
| 7 | Material and labour, 15mm thick cement plaster in CM (1:4) mixed with liquid WPC as per manufacturer’s instructions on the surface of brick work/concrete surfaces of walls, facia of roof projection etc finished even and smooth without using extra cement Note : WPC shall be measured and paid separately, Rate quoted by contractor shall be deemed to include to necessary scaffolding etc. |
| 8 | M&L for cement concrete 1:2:4 type B1 using 20mm graded crushed stone aggregate as padding in roof including necessary formwork as specified, if required. Note :- Padding concrete shall be laid to maintain the slope with thickness at lower end and at ridge as directed by Engineer in Charge. Contractor shall provide leveling bench mark at ridge level and up to edges with distances as specified by Engineer in Charge with water proofing compound. |
| 9 | M&L for cement concrete 1:2:4 type B0 using 12.5mm graded crushed stone aggregate as in roof kerbs or mud stops, chajja rounded or chamfered on edges etc complete all as specified and directed with water proofing compound. |
| 10 | Material & labour cutting out cracks to V section mechanically of minimum width 5mm and depth equal to width in existing RCC roof parapet or terracing, cleaning out and apply Dr Fixit PU sealant (Make : Pidilite or Equivalent) complete all as specified. |
| 11 | Surface Preparation: Existing Surfaces must be clean, even, and soundconcrete. Remove oil, dirt, laitance.Supplying and applying Fiber reinforced elastomeric liquid waterproofing membrane formulated with PU hybrid polymers and reinforcing acrylic fibers with Sun Reflectivity Index (SRI) of 105 on top of roof in three coats @ 1.8 Kg/sqmt to be reinforced, having minimum elongation of 350%, tensile strength 2.9Mpa and shall have crack bridging ability of up to 2.5mm and shall resist 10bars of hydrostatic pressure, reduces surfaces temperature up to 10 degree Celsius also IGBC certified (Indian Green Building Council) Certificate will be provided by company. The system consists of self-priming with 33% water dilution followed by two undiluted coats of Fibre reinforced elastomeric liquid water proofing, the fibermesh of 40 to 50 GSM must be sandwich between 1st and 2nd coat ofFiber reinforced elastomeric liquid waterproofing membrane (dry film thickness of complete application/system not less than 500 microns) and Ponding test to be done after application of material..(i) While doing the treatment on existing roof,concrete should be throughly inspected for any significant distress,such distress if any shall be repaired/rehabilitated and treated.(iii) The work of water proofing to roof and sunken portion shall be executed by the manufacturer's authorized trained/skilled applicator as per technical guidlines and apllication methodology of the manufacturer. The contractor will arrange to provide company back gurantee for the water proofing for the period of 10 year specified here-in-after. |
| 12 | Providing and carrying out waterproofing treatment at roof-parapet junctions,internal corners,outlets, and peneterations, including preparation of surface and application of waterproofing membrane coating as specified.Extending the waterproofing treatment (upturn) on parapet walls, including proper detailing at roof parapet junctions and around all outlets and pipe penetrations, forming fillets at internal corners using polymer modified mortar comprising in approved proportion of cement, polymer, and water in 2:1 :1/2 to ensure complete watertightness with and including waterproofing treatment with fiber-reinforced elastomeric liquid-applied membrane based on polyuethane-acrylic hybrid polymer as (Tech parameter as per item No 10 above)-(a) one coat of self-priming layer by diluting polyurethane material with water (30-35%)(b) second coat of undiluted membrane applied after drying of primer coat.(c) Third and final coat of undiluted membrane applied in cross direction to acheive uniform edge continous coverage.Note- The work of water proofing to roof and sunken portion shall be executed by the manufacturer's authorized trained/skilled applicator as per technical guidlines and apllication methodology of the manufacturer. The contractor will arrange to provide company back gurantee for the water proofing for the period of 10 year specified here-in-after. |
| 13 | Supply only water proofing compound ISI marked complete all as specified. Make: Pidiproof LW+ (Dr Fixit) or equivalent ISI marked make as approved by GE. |
| 14 | Demolition floor, health or wall tilling including cement mortar bedding (but not backing removing survicabletiles to store and rubbish including removing the debris from the site to a designated point by the civil administration complete all as specified and directed by Engineer-in-Charge. |
| 15 | S&F coloured non skid joint free ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white cement or coloured cement to match over 15 mm thick screed bed in cement mortar 1:6 complete. |
| 16 | M&L for coloured non skid joint free ceramic tiles of 7mm to 8mm thick area of each tile exceeding 0.06 Sqm but not exceeding 0.11 sqm in floors, etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10 mm thick rendering in cement mortar 1:4 for laying floor finishes complete all as specified & directed. |
| 17 | S&F joint free coloured non skid ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white cement or coloured cement to match over 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed. |
| 18 | S&F coloured non skid ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in skirting etc. set and jointed in neat cement slurry and pointed in white cement or coloured cement to match over 10 mm thick plastering as backing layer in cement mortar 1:4 complete all as specified and directed. |
| 19 | S&F coloured Glazed ceramic tile in verticle surface area exc 0.06 sqm but n.exc 0.16 sqm set and jointed in neat cement slurry and pointed in white or colour cement to match including rendering 10 mm thick on fair faces of brick work or concrete surfaces as backing coat in cement mortar 1:4 complete all as specified and directed. |
| 20 | Taking down chowkhat or frame with shutter (without taking off shutter from the frame) area exc 1.5 Sqm but n.exc 4 Sqm each, with and including make good the diturbed surface wit PCC 1:2:4 B0 and CM 1:4 to make the surface and edges finished to recive the window/door chowkhats complete all as specified and directed |
| 21 | M&L for plain cement concrete (1:3:6), type C-1, (using 12.5mm graded crushed stone aggregates) as in bed block, blocks for holdfasts, filling in pressed steel door frames , benching slightly rounded or chamfered angles & throating etc including necessary use & waste of form work complete all as specified and directed. |
| 22 | Cutting holes in brick walls exc half brick but n exc one brick in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required complete all as specified |
| 23 | Supply and fix, factory made pressed steel frames for doors with one or more rebates, of size 105mmx60mm, made out of 1.25mm thick sheet, including necessary fixing lugs, hinges, lock strike plate, with and including cement concrete 1:2:4 (type B0) with 12.50 mm graded stone aggregate in backfilling of chowkhats etc, complete all as specified and directed. |
| 24 | Supply and fix, factory made flush shutters 35 mm thick,solid core construction with block board core and plywood face panels commercial type on both sides, duly provided with 6mm thick Teakwood leeping on edges alround, fitted to chowkats, complete all as specified & directed. |
| 25 | S&F 250 mm long aluminium alloy, anodized, sliding door bolt with hasp & staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolt and sliding bolts of extruded section or cast aluminium alloy, ISI marked, complete all as specified and directed by Engr in charge. |
| 26 | S&F, 200mm long, aluminium anodized, barrel tower bolts of extruded section, ISI marked, complete all as specified and directed. |
| 27 | S&F 125 mm long extruded aluminium alloy handles, fabricated type anodised, features a D-shaped pull with backplate of anodised aluminium for mounting complete all as specified and directed. |
| 28 | S&F 140 mm long floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed in floor |
| 29 | M&L preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified. |
| 30 | M&L for preparation of new surfaces of steel and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 31 | Dismantiling ceiling boards of any description including cover fillets, and removal of debris/rubbish out of premises complete all as specified. |
| 32 | Providing and fixing 600 × 600 mm modular lay-in T-grid suspended false ceiling using 24 mm exposed T-gridframework of Everest make with manufacturer’s engraved marking on grid, or equivalent approved make, complete all as specified and as directed, comprising the following:(a) Perimeter Framework: Pre-coated GI wall angle of size 24 × 24 mm, minimum 0.35 mm thick, fixed to wall /partition periphery at required ceiling level using PVC dash fasteners (nylon sleeves) and steel screws @ 300 mm centre to centre, complete.(b) Suspension System: GI Main Tee runners of size 24 × 38 mm, minimum 0.25 mm thick, suspended from RCC soffit / roof purlins by 4 mm dia GI hanger wire, including soffit cleats and Ø6 × 40 mm metal anchor fasteners @ 1200 mm centre to centre, levelling complete.(c) Grid Formation: 1200 mm Cross Tees insert-fixed into Main Tees @ 600 mm c/c to form 600 × 1200 mmmodule and 600 mm Cross Tees insert-fixed into 1200 mm Cross Tees @ 600 mm c/c to form final 600 × 600 mm grid using snap-fit / bayonet locking system, all grid components of same approved make, complete.(d) Ceiling Tiles: Providing and laying 6 mm thick pre-painted fibre cement ceiling tiles of size 595 × 595 mm, fire resistant, conforming to IS 14862 : 2000 – Type B, Category III, having density not less than 1340 kg/m³, MOR ≥ 10 MPa (dry) and ≥ 7 MPa (wet), non-combustible as per BS 476 Part 4, fire tested as per ASTM E-84, placed properly over grid, true to line and level.(e) General: Rate includes all materials, hangers, fasteners, cutting, finishing, levelling, scaffolding, labour, tools, wastage and all incidental works required for complete and satisfactory execution of the item.MAKE: Everest make with engraved marking on grid, OR EQUIVALENT APPROVED MAKE conforming to above specifications and standards. |
| 33 | Dismantling of wall lining , any thickness, including cover fillets, complete all as specified |
| 34 | S&F PVC wall panelling with hollow profile 8 mm thick of panel size 450mmx2900mmx1.65mm with teak or similar colour finish fixed on and including 35mm wide frame with screw/nails clips including top corner and bottom frame complete all as specified 5 mm thick PVC fillet.Make : Mega Star, Amstrong |
| 35 | M&L for rendering 10 mm thick in cement mortar (1:3), as on concrete surfaces in ceiling (such as chajja,beams, roof projection, balcony, mumty and staircase flight ceiling, roof slab etc.) finished even and fair without using extra cement, complete all as specified and directed by Engineer - in -Charge.NoteThe rate quoted by contractor is deemed to be included necessary scaffolding and form work. |
| 36 | M&L for rendering 15 mm thick on brick or concrete surfaces in cement mortar 1:6 finished even and fair without using extra cement, complete all as specified as per directed (Internal plaster). |
| 37 | M&L for rendering 15 mm thick on brick or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement, complete all as specified (External plaster).Note:- The rate quoted by contractor is deemed to be included necessary scaffolding and form work upto 12Mtr height or (G+2) storey building. |
| 38 | M&L for rendering 15 mm thick plaster (1:3) in cement sand mortar with integral water proofing compound for repair of distressed RCC member including scaffolding for suitable working platform as in column, beams, chajja and roof projection, facia by with and including fiber mesh, finishing the surfaces even and smooth without using extra cement and icluding taking down all as specified and directed by Engineer in Charge.Note : (i) Rendering should be done in two layers . First Layer 10mm thick and Second layer 5 mm thick after over wire netting of galvonised mild steel wires of 0.91mm dia and average size of wire mess 20mm fixed with tinned tacks.(ii) Removing all disintegrated and loose portion and cleaning the rust from exposed reinforcement, removing, rusted scales by chipping and cleaning by wire brushes.(iii) The rate quoted by contractor is deemed to be included necessary scaffolding and form work upto 10Mtr height or (G+2) storey building. |
| 39 | M&L preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified. |
| 40 | M&L preparation of newly plastered surfaces of wall and applying three coats of white wash complete all as specified. |
| 41 | Material and labour for preparation of newly plastered surfaces of walls/chajja and applying two or more coats of distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/liter, of approved manufacturere of required shade and colour complete as per manufacturere specifications over a coat of primer and including applying upto 1 mm thick wall care putty on entire surface to acheive smooth finishing by sand-faced of wall complete all as specified and directed. |
| 42 | Material & Labour for applying of new plaster external surface of wall Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over 1mm thick wall care putty of new plaster and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new plastered of any description 12M upto G+2 building, including necessary scaffolding, complete all as specified and directed. Note: Weather proof exterior emulsion paint and primer shall be of same manufacturer. |
| 43 | Demolition of unreinforced cement concrete in ground floors and pavings n. exc 15 cm thickness (below or above ground level) by mechanical means complete all as specified and directed. |
| 44 | Material and labour for 75 mm thick, plain cement concrete 1:3:6, type C-1, using 20 mm graded mechanically crushed stone aggregates, laid in 1:20 slope as in plinth protection including making joints at 3.00 metre intervals and at each corner, the joint shall be filled with mastic filling (to full depth) comprising of one part heated hot blown bitumen 85/ 25 & two parts heated sand (by volume), surface finished even and smooth without using extra cement, complete all as specified. Note: The concrete shall be laid at a stretch not exceeding 3 metre in length and width of joint shall not be more than 12 mm. |
| 45 | M&L 75 mm thick cement concrete type B-1, 1:2:4 (using 20 mm graded crushed stone aggregate), as in floors, ramp etc incl making impressions of expanded metal, whilst the concrete green complete all as specified and directed. |
| 46 | Dismantling structural steel work including doors, gates but excluding framed truss etc. |
| 47 | S&F Collapsible steel gate, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, wheels, brass handle etc,as specified, erected in position and securing runners with holdfast, brackets complete all as specified and directed. |
| 48 | S & F 15mm dia tubes medium grade, galvanized, with all fittings such as sockets, bends, elbows, tees etc, concealed/surface fixed to walls and ceiling or laid in floors complete including taking down old unseviceable all as specified and directed. |
| 49 | S&F steel water tubes, 20 mm bore medium grade, galvanized with all fittings and fixed complete to walls, ceiling or laid in floors, including taking down old unseviceable complete all as specified. |
| 50 | M&L rotational moulded PVC, triple layered, white colour water storage tanks of capacity 500 litre (cylindrical vertical with closed theard pettern top cover), ISI Marked, hoisted and fixed in position, with & including all fittings such as GI tank nipple etc, including all valve, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball, ISI marked (Minimum weight 210 gms), screwed & suitable for iron pipe 20 mm bore and dismantling unserviceable PVC water tank complete all as specified and directed. |
| 51 | S&F in repairs 20mm bore dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed. |
| 52 | S&F in repairs Vitreous China wash down water closet with plastic seat cover (pedestal pattern), white (excluding fixing bolts flushing cistern and flush pipe) including 100mm certifugal cast iron (Spun) 'P' & 'S' trap and 100mm centrifula cast iron (spun) sanitary connection socket to fit WC outlet including connection to trap, to flushing pipe, anti-syphonage pipe etc. complete all as specified and directed. |
| 53 | S&F in repair 15 mm bore pillar taps, cast copper alloy, fancy type with capstan heads, chromium plated screwed down high pressure with or without lattered 'Hot' or 'Cold' with long screwed for iron pipe and fixed. |
| 54 | S&F in repairs Health faucet (ABS Body) stainless steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed. |
| 55 | S & F 10 litres capacity, PVC valve less, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and suitable flush pipe PVC 32mm dia complete all as specified and directed. |
| 56 | S&F in repairs wash basins, vitreous china, white, rectangular type of size 550x400mm including brackets and cutting for and pinning in ends of brackets or erecting stand 32mm dia waste (PTMT Coupling) fittings, brass, chromium plated with long screwed shanks and fly nuts, over and including new brackets complete all as specified and directed. |
| 57 | S&F PVC waste pipe flexible for WHB/urinal of 32/40mm size complete all as specified and directed. |
| 58 | S&F in repair soap dish brass, chromium plated fancy type of standard size and specification as directed and fixed to plugs with chromium plated brass screws. |
| 59 | S&F in repairs looking mirror 600 mm x 450 mm beveled edge mirror of selected quality glass mounted on 6 mm thick commercial plywood with decorative type wooden frame and fixed to wooden plugs with steel screws, complete all as specified and directed. |
| 60 | S&F in repairs towel rail 600 mm long, 20 mm dia, ‘D’ type, chromium plated, fixed to walls with screws and plastic cleats, complete all as specified and directed. Make-Prayag SS Towel Rail Cubix Cat No. CPA-46 |
| 61 | S&F in repairs chromium plated grating doom 125mm dia with or without hole complete all as specified and directed. |
| 62 | S&F in repair Vitreous China Urinal, Half stall type, white (excluding flushing cistern), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including waste coupling, 60mm long brass screws, pointing around urinal back in white cement; flush pipe, grating and Union for discharge pipe complete all as specified and directed. |
| 63 | S&F urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (min wt 60 gms). |
| 64 | S&F PVC connections 15 mm size with PTMT nuts of length 450 mm. |
| 65 | S&F 110 mm bore PVC (SWR) pipes with, single socketed in any length with rubber ring joints fixed to wall including holding holder /clamps and making good the mouth of rain water pipe including taking down as directed complete all as specified. |
| 66 | Dismantling PVC/CI/AC drain pipe n.exc 110 mm dia |
| 67 | S&F 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified & directed by Engineer-in-Charge. |
| 68 | S&F 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified & directed by Engineer-in-Charge. |
| 69 | S&F 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls complete all as specified & directed by Engineer-in-Charge. |
| 70 | S&F PVC 75 mm bore (SWR), junction single, (Single T) equal or unequal with access door |
| 71 | S&F PVC 110 mm bore (SWR), junction single, (Single T) equal or unequal with access door |
| 72 | S&F PVC 110 mm bore (SWR) reducers |
| 73 | S&F 75 mm PVC (SWR) vent cowl complete all as specified & directed by Engineer-in-Charge. |
| 74 | S&F 75 mm bore PVC (SWR) bends andy radius complete all as specified & directed by Engineer-in-Charge. |
| 75 | S&F 110 mm bore PVC (SWR) bends any radius complete all as specified & directed by Engineer-in-Charge. |
| 76 | M& 75 mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified & directed by Engineer-in-Charge. |
| 77 | Hacking out old broken glass (any thickness, size, quality or description) from metal frame incl punching or drilling out old glazing pin, spring/clips and providing and fixing new ones. |
| 78 | S&F 4.0 mm thick frosted glass, pin head type and glazing with oil putty in square n.exc 0.5 sqm in each pane complete all as specified and directed. |
| 79 | S&F 4.0 mm thick sheet glass ordinary quality and glazing with oil putty in square n exc 0.5 sqm in each pane complete all as specified and directed. |
| 80 | M&L preparation of old plastered surfaces of walls and applying two coats of whtie wash complete all as specified. |
| 81 | M&L for complete removal of existing treatment from internal surfaces on walls by wire brushes and applying with one coat of 1mm average thick cement wall care putty to obtain smooth regular/even finish surfaces by using sand paper and applying two coats of Acrylic Distemper, complete all as specified and directed. |
| 82 | M&L for complete removal of existing treatment and preparing plastered or unplastered old surfaces of walls including brooming down or steel wire brushing, scraping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and filling the cracks/holes with wall care putty to rubbing down and stoping of surfaces using sand paper and applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm on old surfaces of any description complete all as specified and directed. |
| 83 | M&L preparation of old painted wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified. |
| 84 | M&L preparation of old painted steel and iron surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enemel paint complete all as specified and directed. |
| 85 | Dismantling asbestos cement (corrugated, semi corrugated etc,) sheets in roof covering. |
| 86 | Dismantling wrought iron or mild steel works of any description not otherwise provided for. |
| 87 | S&F framed brackets of angles or tees with web and flanged cut to shape, drilled and countersunk for screw, incl bending and welding anglres as necessary guesset plates, reveting, wtc., n.exc 10 Kg each brackets conforming to Fe 290, Gde-E-165 (Brackets conforming each to be measured under structureal steel.) |
| 88 | S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fascia/evs etc fixed with self tapping screws as specified. |
| 89 | S&F pre-painted galvalume aluminium zinc coating GI based plain sheet steel sheet0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. |
| 90 | M &L providing cement concrete 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) in roof kerb or mud stops, rounded or chamfered complete all as specified and directed by Engr-in-Charge. |
| 91 | S&F galvanised, 2 strand, steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacings and straining and fixing to any type of standard rails to any type of standard rails straining bolts, incl securing or tying at crossings with and provision of galvanised mild steel wirem staples or steel pins, etc as directed (each line wire to be measured). |
| 92 | Dismantling of barbed wire fencing of any description and removal to store for credit, complete all as spedified and directed. |
| 93 | M&L machine cut kota stone slab flooring 18-20 mm thick over 20 mm thick cement screed base of cement mortar 1:6, laid and jointed with grey cement slurry mixed with pigment to match the shade to the slab incl rubbing and polishing complete. |
| 94 | M&L machine cut kota stone slab 18-20 mm thick in riser of steps, skirting, dado and pillar laid over 10 mm thick cement screed of cement mortar 1:3 and jointed with grey cement slurry mixed with pigment to match the shade to the slab incl rubbing and polishing complete. |
| 95 | Demolition stone slabs and tiles of any description or thickness in floors/ dado, aprons etc., laid bedded and pointed in any mortar, complete all as specified and directed. |
| 96 | M & L for Granite (of any type ) 16 to 18 mm thick, work (table rubbed and polished) fine grained 'Z' black/red in cooking platforms/Jambs including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including screed bed of 15 mm thick in CM 1:4, and rounding of edges complete all as specified. |
| 97 | Supply and fixing in repair kitchen sinks made of Stainless steel 1.00mm thick with plugs, washers and waste pipes including bedding in cement mortar to dwarf wall or including fixing cantilever brakets including and connecting union to pipe over all size 495mm X 420mm bowl size 410mm X 330mm X 160mm including 40 mm dia waste fittings, brass, chromium plated sinks,with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other complete all as specified and directed. |
| 98 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars etc. but excluding ashlar facings, dressed stone work & precast concrete articles complete all as specified & directed. |
| 99 | M&L for brick work sub class “B” bricks straight or curveted in plan exc. 6mtr mean radius with old size bricks Iin CM 1:6 all as specified. |
| 100 | S&F powder coated anodised aluminium door shutters, aluminium section min 2mm thick incl necessary joining cleats, glazing clips, rubber neoprene packing, aluminium snap beading screws etc. complete all as specified. |
| 101 | Taking down shutters of any description exc 2 Sqm and refixing in the same opening. |
| 102 | S&F powder coated anodised aluminium window and ventilator shutters, side hung type without sash bar, aluminium section min 2mm thick incl necessary joining cleats, glazing clips, rubber packing, anodised aluminium spap beading, screws etc, complete all as specified. |
| 103 | S & F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge. |
| 104 | S&F powder coated aluminium gril 8mm thick (anodised transparent or dyed to required shade acoording to IS: 1868 with minimum anodic coating of grade AC 15) of approved design /pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @200 mm centre to centre, including, cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. |
| 105 | S&F, 150mm long, aluminium anodized, barrel tower bolts of extruded section, ISI marked, complete all as specified and directed. |
| 106 | S&F aluminium (Die cast body) door closer hydraulically requlated designation No. 3 universal type, suitable for door shutters of 851 to 1000 mm in width and of weight 61 to 80 Kg and fixed. |
| 107 | S&F in repair aluminium (Die cast body) door closer hydraulically requlated designation No. 3 universal type, suitable for door shutters of 851 to 1000 mm in width and of weight 61 to 80 Kg and fixed. |
| 108 | Providing and fixing 6mm thick Alumunium composite panel (ACP) cladding of approved color and shade,made of 0.25 mm thick aluminium skins on both side with LDPE core,fixed over existing frame work,using SS screws,aluminium cleats,angles,adhesives and necessary hardware including cutting, bending,grooving,sealing of joints with weather-proof silicone sealant,complete as per manufacturer's specification and directions of engineer-in-charge |
| 109 | S&F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with stainless steel wire staples. |
| 110 | S&F in repair stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with stainless steel wire staples. |
| 111 | Taking up or down steel water tubing and connections, including cleaning for refixing or removal from site, for bore of pipes 15mm dia complete all as specified and directed. |
| 112 | Taking up or down steel water tubing and connections, including cleaning for re-fixing or removal from site, for bore of pipes 20mm dia complete all as specified and directed. |
| 113 | Providing and fixing 8 mm thick toughened frosted glass urinal partiion wall mounted of size 450mmx900mm, made from high quality float glass, edges machine polished, corner rounded. The glass shall be fixed with SS 304 Grade heavy duty brackets/clamps incl all necessary fittings such as bolts,screws wall plugs spacers and rubber gasket complete all as manufactures specifications.Cat Part No. S4090102 Make Cera and equivalent. |
| 114 | S&F in repair Vitreous china oval shape wash basin of size (550 x 440 mm), white, flat back, fixing on granite top, including 32mm dia CP brass coupling, along with PVC waste pipe complete, including connection to pipe etc, with and including 15mm dia 450mm long PVC connection pipe with steel check nut (exluding taps) including & pinning in ends of brackets and taking down and removal of old wash hand basin , complete all as specified. |
| 115 | S&F 15 mm bore stop/angle valves, fancy type chromium plated cast copper alloy screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for union and fixed. |
| 116 | S&F in repair 15 mm bore Fancy type two way Bib taps, cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed. |
| 117 | S&F in repair 15 mm bore brass CP basin mixer swan neck for mixing hot & cold water screwed down for iron pipe and fixed |
| 118 | S&F 18/19 mm thick Prelaminated particle, board, exterior grade, prelaminated one side with decorative choice laminations & other side balancing white lamination, fixed with screws/dashfastener to timber frame work or in brick wall as in kitchen cabinet complete alll as specified |
| 119 | Magnetic catcher with Ball catches with 8mm dia steel ball, and brass body and striking plate including letting in and fixed suitable for kitchen cabinate/cupboard,complete all as specified and directed by Engineer-in- Charge. |
| 120 | S&F 40 mm dia cub board knobs fixed with nut, screw and washer of Brass, polished |
| 121 | M&L 2nd class hard wood plain fillets, square, rectangular or trinagular in section, clean sawn, secured with nails or brads, sectional area exc 13 sqcm but n.exc 25 sqcm fixed as frame work of cupboard, cabinet etc and fixed to existing wall with SS screws and PVC plugs complete all as specified and as directed.Note :- Treating wooden surface joint with wall surface with a coat of black paint . |
| 122 | S&F chequered cement concrete tiles 30 cm x 30 cm x 25 mm thick with grey cement and pigments, set, jointed and pointed in neat cement slurry in floors over 20 mm thick screed bed in cement mortar 1:6. |
| 123 | Demolition of reinforced cement concrete any description and in any position not otherwise specially provided for. |
| 124 | Complete removal of exisitng treatment on wall surface including washing, rubbing down by wire brush of old painted surface and roughning the surface to receive the plaster complete all as specified and directed. |
| 125 | M&L 40 mm thick cement concrete type B-1, 1:2:4 (using 20 mm graded crushed stone aggregate), as in sub base of floors. |
| 126 | Taking down chowkat or frame with shutters (without taking off shutters from the frame) exceeding 1.5sqm each n exc 4sqm each and making good to disturbed surfaces and refing in same opening complete all as specified and as directed by the Engineer-in-Charge. |
| 127 | Taking down rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks,tee, reducer etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified |
| 128 | INTERNAL ELECTRIFICATION WORK |
| 129 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed. |
| 130 | M&L for Point wiring with 1.5 Sqmm single core PVC insulated , unsheathed cable FRLS, 1100 volt grade with multi stranded copper conductor drawn through and incuding med grade, ISI marked PVC conduit not less than 20 mm dia with accessories concealed on wall/ceiling and incuding provision of 1.5 Sqmm single core PVC insulated , unsheathed cable FRLS, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including MS sunken box or pressed steel terminal boxes made out of 1.6 mm thick MS sheet with provision of new 3 mm thick plastic laminated sheet top cover over sunken box for housing the switches , socket outlets, fan regulators etc. with brass screws and brass washers incl and making good the disturbed surfaces as per existing for for One light/Ceilinf fan/Exhaust fan point controlled by one switch complete all as per specified and directed. |
| 131 | All as per item No 2.0 above but for one socket outlet point 5 Amps on same board. |
| 132 | All as per item No 2.0 above but for one socket outlet point 5 Amps on independent board. |
| 133 | All as per item No 2.0 above but for one bell point controlled by one bell push. |
| 134 | All as per item No 2.0 above but with 2.5 sqmm cable for 3 pin 15 amps switch socket outlet (Power point) |
| 135 | Supply and fix switch piano 6 Amps flush type single pole one way 230 volt , AC supply complete all as specified. |
| 136 | Supply and fix switch piano 16 Amps flush type single pole one way 230 volt , AC supply complete all as specified. |
| 137 | Supply and fix socket outlet 3 pin 6 amps 230 volt AC flush type complete all as specified. |
| 138 | Supply and fix socket outlet 2 in 1, 3 pin 6/16 amps 230 volt. flush type complete all as specified. |
| 139 | Supply and fix bell push 5 Amps flush type single pole one way 230 volt , AC supply complete all as specified. |
| 140 | Supply and fixing in replacement door bell electric , ding dong type, single phase 230 volts, complete all as specified. |
| 141 | Supply and fix ceiling rose 3 phase/PVC/polycarbonate, isolated body complete all as specified. |
| 142 | Supply and fixing LED lights fitting 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 143 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed. |
| 144 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. |
| 145 | S & F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd complete all as specified and as directed. |
| 146 | Supply and fix Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed. |
| 147 | M&L for Sub Main Wiring with two single core PVC FRLS insulated cable of size 4.0 Sqmm multistranded copper conductor cable' drawn through concealed PVC conduit of suitable size, with all fixing accessories and 4.0 Sqmm multistrand copper conductor cable as earth continuity wire including cutting chases, pinning in cement mortar, plastering, making good the disturbed surfaces to match with the existing surface and including taking down old submain wiring complete all as specified and as directed. (Note :- Two Nos of 4.0 Sqmm Wire and One No of 4.0 Sqmm Earth wire in One RM length Measured as one unit length). |
| 148 | M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required GI or steel wire 4.00mm dia, including taking down old one complete all as specified and directed. |
| 149 | M&L test point terminal block made of gun metal or phosphorous bronze of size 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal head screws, including taking down old onecomplete all as specified and directed. Note : (i) Enclosure shall be made up FRP box of suitable size. Make-Sintex/Hensel |
| 150 | M&L for 40mm dia steel tubes (Light grade) galvanised with fittings, laid in trenches/wall for protection of underground earth strip when crossing the road/fixing on wall as in repair complete all as specified and directed. |
| 151 | Taking down carefully earthing GI strip/Al Strip and refixing the same complete all as specified and directed. |
| 152 | Supply and fix aluminium strip 25 x 3.15mm witwith saddles and fixing screws on porecelain insulator/ spacer fixed at every 1 mtr length for extension, re-routing an re-allignent etc of earthing strip on roof/wall and joining the same with existing/New earth test poin complete all as specified and as directed. |
| 153 | S&F GI strip 32 x 6.0 mm with saddles and fixing screws on porecelain insulator/ spacer fixed at every 1 mtr length for extension, re-routing an re-allignent etc of earthing strip on roof/wall and joining the same with existing/New earth test point complete all as specified and directed by Engr-in-Charge. |
| 154 | M&L in repairs for air termination, single pointed aluminium rod, 12mm dia and 300mm long including necessary fixing arrangement using clamp, base plate nuts and bolts after taking down old unserviceable termination rod complete all as specified and directed. |
| 155 | Supply and fix MS Hollow Section recttangular pipe Size 100 mm x 50mm x 3.2 mm with all including special shaped washer etc complete all as specified and as directed. |
| 156 | M&L for earthing complete with Galvanised steel earth plate electrode of size 600mmx600mmx6mm, buried directly in ground (earth pit not less than 2.25 Mtr deep below normal ground level) with top edge of earth plate not less than 1.5 Mtrs deep below normal ground level, connected to GI earth strip of size 32x6 mm by means of brazing and connected to earthing test point / distribution board/equipments or any other indicated situation by means of brazing all as shown in electrical plate No.3 of SSR Part I (2009) and testing on completion including necessary excavation and earth work in any type of soil, returning filling, removing of soil. GI medium grade pipe 20 mm dia 1.5 mtr long with funnel wire mesh as watering pipe, and GI medium GI medium grade pipe 32mm dia as earth lead protection pipe.Earth pit chamber made of PCC 1:2:4 type B1 using 20mm graded stone aggregate including 40mm thick chamber cover made of 1:2:4 type B1 using 20mm graded stone aggregate and reinforced with 8mm dia TMT bars at 100 c/c on both ways precast chamber cover with lifting handle 16mm dia round bars including chorcoal and common salt in alternate layer of 15cm thick covering all faces of earth electrode plate, including taking down old one, complete all as specified and directed.(Note :- (i) The rates quoted for the complete earthing shall deemed to include the cost of GI wire 4.00 mm dia and GI medium grade protection pipe upto 7.5 Mtrs.(ii) GI earth strip and GI medium grade protection pipe beyond 7.5 Mtrs length shall be measured and paid separately.(iii) Fresh red soil required to be re-filled and existing calcium carbonate skeleton mixed soil to be removed from site. |
| 157 | S&F in repairs LED street light fitting 45 watt, 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. including taking down u/s fitting complete all as specified and as directed. |
| 158 | Taking down carefully existing celling fan/Exaust fan and cleaning , greassing and refixing the same complete all as specified and directed. |
| 159 | Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc, and cutting chases for concealed conduit wiring and making good, cutting not exc 10 cm girth, complete all as specified and directed by Engineer in charge. |
| 160 | Supply and fix in repair sheet metal enclosure single pole and neutral with a two pin socket and earth plug complete with one MCB single pole and 240V, 20 Amp ‘B’ curve, 10 kA, oe complete all as specified and directed . |
| 161 | Supply and fix in repair sheet metal enclosure single pole and neutral with a two pin socket and earth plug complete with one SPN/DP MCB of 240V, 20 Amp ‘B’ curve, 10 kA, oe complete all as specified and directed . |
| 162 | Supply and fixing sheet metal enclosure TPN verticla type type DB 430 volts 4 way double door type, with 200 amps rated bus bar with IP43 protection & conforming to IEC 61439-1&3, IS:8623-1&3 complete all as specified and directed by Engr-in-Charge. |
| 163 | S & F MCCB 4 Pole of capacity 100 Amps, 50 Hz, 415V with rupturing capacity of 16 KA including spreader terminals complete all as specified and directed. |
| 164 | Supply and fix MCB single pole 240 volts, 50Hz , breaking capacity 10KA, B curve 6A to 32A, ISI marked all as specified and as directed. |
| 165 | Supply and fixing Mild steel ciling fan hanging road 2 feet to 4 Feet (White colour) including all fitting nuts and bolts all as specified and directed. |
| 166 | Supply and fix Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers, connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, incl making hole in wall and make good as existing incl dismantling and taking down old unsv complete all as specified and directed. Note: Old unsv exhaust fan will be diposited in MES store yard. |
| 167 | All as per item No 12.00 above but 450mm sweep size exhaust fan. |
| 168 | Supply and fix MCCB 4 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 36 KA, ISI marked all as specified and as directed. |
| 169 | Supply and fix MCB single pole 240 volts, 50Hz , breaking capacity 10KA, C curve 6A to 32A, ISI marked all as specified and as directed. |
| 170 | Supply and fix MCB SPN 240 volts, 50Hz , breaking capacity 10KA, C curve 40A to 63A A, ISI marked all as specified and as directed. |
| 171 | Supply and fixing in repair Load line TPN vertical distribution board 6 Way double door dust protected powder coated inclusive of busbar, neutral link, blanking plates and having provision of MCCB/TP as incomer and MCBs SP/TP as outgoing as per IS - 01 No, having IP-43 protection, complete all as specified and directed. |
| 172 | Supply and fix sheet metal enclosures distribution board SPN 12 ways double door , IP 43 protection, 240 volts, with shrouded neutral bar & insulated bus bar and earth link, suitable for MCBs/RCBOs as incomer and out going complete dully grouted on the wall (flush) incl dismantling and taking down old unsv and making connections with suitable size of lugs and making good the disturbed surface matchig with existing surface all as specified and directed. |
| 173 | All as per item No 18.00 above but 8 way DB double door. |
| 174 | Material and labour for sub main wiring with two single core PVC insulated , unsheathed stranded copper conductor cable FRLS 6 sqmm drawing in concealed conduit not less than 25 mm dia with accy and making good the disturbed surface incl one additional PVC insulated , stranded copper conductor FRLS of 6.0 sqmm, green colour for earth continuity conductor incl taking down of unsv sub main wiring complete. |
| 175 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete. |
| 176 | Taking down Air termination, single pointed aluminium rod 12 mm dia and 300mm long including galvanised iron pipe complete all as specified and as directed. |
| 177 | Supply & fix single pointed air termination aluminium rod 12mm dia, 300 mm long complete all as specified and as directed. |
| 178 | Supply and laying GI Pipe medium grade 40mm dia for protection of earth lead complete all as specified and as directed. |
| 179 | EXTERNAL ELECTRIFICATION WORK |
| 180 | M&L for supply, laying, jointing and commissioning in replacment PVC insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, 3.5 core, cross-sectional area 70 sq. mm including taking down old u/s cable of any size complete all as specified and as directed. |
| 181 | All as per item No 1.00 above but size of cable 50 sq mm, 3.5 core. |
| 182 | All as per item No 1.00 above but szie of cable 16 sq mm, 4 core. |
| 183 | Excavation in trenches in soft/loose soil not exceeding 1.5 meter wide and not exceeding 1.5 meter deep for laying of LT XLPE cables and foundation of poles etc. and getting out complete all as spceified and as directed. |
| 184 | Returning, filling in trenches (soil) including spreading leveling and well ramming in layers not exc 25 cm thick complete all as specified and as directed. |
| 185 | Removal of excavated material (surplus soil) to a distance not exceeding 50m and depositing where directed at level not exceeding 1.5m above the starting point, complete all as specified and directed. |
| 186 | M&L for Sand cushioning for cable with river washed sand and punning to provide required cover as per SSR part I complete all as specified and as directed. |
| 187 | Supplying and laying reinforced precast concrete cable cover, Class LV, Type 2, flat, size 300mm x 180mm x 40mm for cable protection complete all as specified and as directed. |
| 188 | M&L for boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and as directed. |
| 189 | Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 70 to 95 sqmm,Indoor/Outdoor type complete all as specified and as directed. |
| 190 | M&L for earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick, burried dirctly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised earth lead by means of bolts, nuts, check nuts and washer of galvanised iron strip 32 x 6mm as earth lead as shown in electrical plate No. 3 of SSR Part I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal od surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm bore GI tubing medium grade for watering pipe, 40mm bore medium grade GI pipe for protection of GI earth strip and pre-cast earth pit cover 50mm thick made of RCC (1:1.5:3) tyep A1 duly reinforced with 8mm dia TMT bar @ 100 mm c/c both ways, one lifting handle made out of 10mm dia TMT bar 250mm long embedded in cover slab and cover, wire, copper lugs etc mesh, charcoal and common salt in alternate layer of 15 cm thick including taking down old unserviceable one complete all as specified and directed. Note : (i)Rate shall include GI strip / wire and protection pipe of length 7.5m, excess beyond 7.5m length required at site shall be measured and paid seperately.(ii) Earth resistance should be less than 3 ohm. In case the test results are not found below 3 ohm, complete earthing will be redone without any extra cost to the Govt. |
| 191 | S&F Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32x6mm galvanised iron strip. |
| 192 | Supply and fixing LED street light fitting 70 Watt 230 V AC outdoor type with high pressure diecast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed. |
| 193 | S&F and laying GI tubing light grade 80mm dia including all fitting and connections for road crossing along with pole/ culvert / drainage for mechanical protection of cable complete all as specified and as directed. |
| 194 | Supply and fix epoxy based insulator of suitable size 40mm height for fixing GI/ Al earth strip on wall / ceiling / floor / poles etc complete all as specified and as directed. |
| 195 | Note: The Total amount shall subject to adjustment of credit of Rs.74440.03 for old Materials as per Schedule of Credit. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 8 daysCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 8 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender