Health and Family Welfare Boards / Undertakings / PSU Closing in 0 days TDR #56786149

Tender For Reporting Station At Histopath Lab Archive Bldg., 4Th Floor, Actrec

Issued by Boards / Undertakings / PSU · Raigad, Maharashtra
Tender Value
9.83 Lakhs
Estimated cost
Bid Submission
20 Aug 2026
0 days left
EMD
16975
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Raigad → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Reporting Station At Histopath Lab Archive Bldg., 4Th Floor, Actrec

BOQ

Name of Work:- Reporting Station at Histopath Lab Archive Bldg., 4th floor, ACTREC
Sl. No. Item Description
1Civil Works
2All Modular furnitures are to factory manufactured & approved for design colour combination with physical sample supplied at site. On approval with correction if any shall be supplied in total qty.
3Supply & Installtion of Modular workingtable of in 1200/1500/ x 600 x 750mm high with base frame made out of metal powder coated with granite top with edge moulded finish placed on 12mmthick marine grade playwood to line and level complete as directed and instructed.
4Supply & installtion of Metal poweder coated Storage units / drawer unit of min 600 in width with or wothout heavy duty castores complete as directed and instructed.
5Supply & Installtion of heavy duty Mid back revolving Office chairs of reputed make as per approved sample.
6Supply & Installtion of ceramic Wash basin with CPVC water and drain connection, CP bib tap, CP angle cock with CP flexible pipes complete as directed and instructed.
7STRUCTURAL STEEL WORK: At all levels including supplying cutting fabricating welding or blotting erecting and fixing in position including painting with a primary coat of approved steel primer and finishing with two or more coats of synthetic enamel paint of approved shade including cost of materials labour with chasing in wall or embedding in floor and making good the same by filling 1:2:4 cement concrete and plastering if necessary all as specified and directed by Engineer-in-Charge.
8OPEN SHELF: Providing and fixing in position shelf of required size made of 19mm thick ply of approved make with T.W.lipping patti of 6mm thick of required size to all exposed surface with 1.5mm approved laminated on top of the shelf mounting over the bracket made out of 40mm x 40mm T.W section bracket with fully laminated surface with bracket.Etc.complete all specified and directed by Engineer-in-Charge.
9Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
10Internal wall paint With two coats of primer and two coats of paint -Using Luster Paint with base primer of tow coats and fulling the undulation with putty and whicte cement based putty to get ecen surface complete as directed and instructed.
11ELECTRICAL WORKS
12Online UPS - Input supply: Single Phase, Output Supply : Single PhaseSupplying, installation, Testing & Commissioning of following capacity at fullload (Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS)system suitable for Single Phase input, Single Phase output AC Supply. TheUPS shall include a Rectifier, inverter, external battery bank suitable for 30 minutesback up (Battery VAH capacity shall not be less than 1600 VAH per KVA ofUPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF inABS Container) and Static Bypass switch along with provision for manualbypass, suitable isolation transformer for additional protection againstneutral faults etc. The UPS systems shall be Microprocessor based DigitalControl, using Insulated Gate Bipolar Transistor (IGBT)'s both for therectifier & inverter with PWM (Pulse Width Modulation) Technology. Thequality of design, manufacturing and inspection process should confirm tothe relevant Inter-national standards such as IEC/EN/VDE. The operatingefficiency of the UPS systems shall be >95% at 100% non-linear loads.Current total harmonic distortion (ITHD)/ total demand distortion (TDD) onthe input grid shall be < 5% at 100 %load. (The required LC filters shall beincluded in UPS cost), extreme power factor kit to be include to limit the inputpf to 0.99 and output power factor shall be unity (i.e. kw rating of the UPSshall be kva rating x 1 ) however UPS shall be suitable to take load at 0.7laging to 0.7 leading power factor loads. UPS shall be suitable for incomingsupply AC single phase 160-270V 50 Hz and delivering output AC supplytrue sine wave single phase 220/230/240 Volt, 50 Hz +/- 0.2Hz, Overloadcapacity of 120% for 10 mins and 150% for 1 minute.
131Ph input , 1 Ph output 230volt 50HZ, 3 KVA UPS including external batteries , internal links , racks , and required earthing accessories
141Ph input , 1 Ph output 230volt 50HZ 2 KVA UPS including external batteries , internal links , racks , and required earthing accessories
15Wiring for circuit/ sub main wiring (Power Point) along with earth wire with the 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire sizes of FRLS PVC insulated copper conductor, single core cable including surface/ recessed medium class PVC conduit/ casing capping, bends and all fixing accessories as required.
1616 to 32A DP MCB with Metal Enclosure Type C
17Supplying and fixing following size/ modules, PVC / GI box alongwith modular base & cover plate for modular switches in surface or recess etc. as required. • All the power socket tagging to be provided , PVC tags to be provided.• All the power sockets inside and power panel inside wiring ferruling to be done as instructed by EIC ES
186 Module
19Supplying and fixing following modular switch/ socket on theexisting modular plate & switch box including connections butexcluding modular plate etc. as required.
20Modular switch 6A/16A
21Modular Socket 6A/16A Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56786149
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 9.83 Lakhs
LAST DATE 20-08-2026
Authority
Authority Name Tata Memorial Centre
Work Description Tender for Reporting Station At Histopath Lab Archive Bldg., 4Th Floor, Actrec
Basic Detail
Tender No CB/ET-33/Reporting Station at Histopath lab/2026
Bidding Type Tender
Location
City Raigad
State Maharashtra
Key Dates
Publish Date 01 Aug 2026
Submission Date 20 Aug 2026
Open Date 21 Aug 2026
Finance
Tender Value 9.83 Lakhs
Tender Fee Ref. Documents
EMD 16975
Exemption Not Available
Document List
AnnexureForm.xls
BOQ_966995.xls
f0f9e23c-4808-46f3-8fc7-45a8926327e6.html
TD.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 01, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 20, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Today
Aug 21, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 1 day

Tender Documents

Download All (ZIP) ↓
xls

AnnexureForm.xls

xls

BOQ_966995.xls

html

f0f9e23c-4808-46f3-8fc7-45a8926327e6.html

pdf

TD.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders