Project Description
Tender for Reporting Station At Histopath Lab Archive Bldg., 4Th Floor, Actrec
BOQ
| Sl. No. | Item Description |
| 1 | Civil Works |
| 2 | All Modular furnitures are to factory manufactured & approved for design colour combination with physical sample supplied at site. On approval with correction if any shall be supplied in total qty. |
| 3 | Supply & Installtion of Modular workingtable of in 1200/1500/ x 600 x 750mm high with base frame made out of metal powder coated with granite top with edge moulded finish placed on 12mmthick marine grade playwood to line and level complete as directed and instructed. |
| 4 | Supply & installtion of Metal poweder coated Storage units / drawer unit of min 600 in width with or wothout heavy duty castores complete as directed and instructed. |
| 5 | Supply & Installtion of heavy duty Mid back revolving Office chairs of reputed make as per approved sample. |
| 6 | Supply & Installtion of ceramic Wash basin with CPVC water and drain connection, CP bib tap, CP angle cock with CP flexible pipes complete as directed and instructed. |
| 7 | STRUCTURAL STEEL WORK: At all levels including supplying cutting fabricating welding or blotting erecting and fixing in position including painting with a primary coat of approved steel primer and finishing with two or more coats of synthetic enamel paint of approved shade including cost of materials labour with chasing in wall or embedding in floor and making good the same by filling 1:2:4 cement concrete and plastering if necessary all as specified and directed by Engineer-in-Charge. |
| 8 | OPEN SHELF: Providing and fixing in position shelf of required size made of 19mm thick ply of approved make with T.W.lipping patti of 6mm thick of required size to all exposed surface with 1.5mm approved laminated on top of the shelf mounting over the bracket made out of 40mm x 40mm T.W section bracket with fully laminated surface with bracket.Etc.complete all specified and directed by Engineer-in-Charge. |
| 9 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 10 | Internal wall paint With two coats of primer and two coats of paint -Using Luster Paint with base primer of tow coats and fulling the undulation with putty and whicte cement based putty to get ecen surface complete as directed and instructed. |
| 11 | ELECTRICAL WORKS |
| 12 | Online UPS - Input supply: Single Phase, Output Supply : Single PhaseSupplying, installation, Testing & Commissioning of following capacity at fullload (Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS)system suitable for Single Phase input, Single Phase output AC Supply. TheUPS shall include a Rectifier, inverter, external battery bank suitable for 30 minutesback up (Battery VAH capacity shall not be less than 1600 VAH per KVA ofUPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF inABS Container) and Static Bypass switch along with provision for manualbypass, suitable isolation transformer for additional protection againstneutral faults etc. The UPS systems shall be Microprocessor based DigitalControl, using Insulated Gate Bipolar Transistor (IGBT)'s both for therectifier & inverter with PWM (Pulse Width Modulation) Technology. Thequality of design, manufacturing and inspection process should confirm tothe relevant Inter-national standards such as IEC/EN/VDE. The operatingefficiency of the UPS systems shall be >95% at 100% non-linear loads.Current total harmonic distortion (ITHD)/ total demand distortion (TDD) onthe input grid shall be < 5% at 100 %load. (The required LC filters shall beincluded in UPS cost), extreme power factor kit to be include to limit the inputpf to 0.99 and output power factor shall be unity (i.e. kw rating of the UPSshall be kva rating x 1 ) however UPS shall be suitable to take load at 0.7laging to 0.7 leading power factor loads. UPS shall be suitable for incomingsupply AC single phase 160-270V 50 Hz and delivering output AC supplytrue sine wave single phase 220/230/240 Volt, 50 Hz +/- 0.2Hz, Overloadcapacity of 120% for 10 mins and 150% for 1 minute. |
| 13 | 1Ph input , 1 Ph output 230volt 50HZ, 3 KVA UPS including external batteries , internal links , racks , and required earthing accessories |
| 14 | 1Ph input , 1 Ph output 230volt 50HZ 2 KVA UPS including external batteries , internal links , racks , and required earthing accessories |
| 15 | Wiring for circuit/ sub main wiring (Power Point) along with earth wire with the 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire sizes of FRLS PVC insulated copper conductor, single core cable including surface/ recessed medium class PVC conduit/ casing capping, bends and all fixing accessories as required. |
| 16 | 16 to 32A DP MCB with Metal Enclosure Type C |
| 17 | Supplying and fixing following size/ modules, PVC / GI box alongwith modular base & cover plate for modular switches in surface or recess etc. as required. • All the power socket tagging to be provided , PVC tags to be provided.• All the power sockets inside and power panel inside wiring ferruling to be done as instructed by EIC ES |
| 18 | 6 Module |
| 19 | Supplying and fixing following modular switch/ socket on theexisting modular plate & switch box including connections butexcluding modular plate etc. as required. |
| 20 | Modular switch 6A/16A |
| 21 | Modular Socket 6A/16A Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 01, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 20, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
TodayAug 21, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 1 dayTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender