Tender For Tender For Survey, Supply, Design ,Erection Testing & Commissioning Of 11 Kv Ht Line, 2 Nos. 63 Kva New Dtr, Shifting Of Existing 250 Kva Dtr From Bed To Pole Mounted, L T Line, Civil Works , Ct Pt Combined Unit For Providing Sop To Water
Tender Overview
Project Description
Tender for Tender For Survey, Supply, Design ,Erection Testing & Commissioning Of 11 Kv Ht Line, 2 Nos. 63 Kva New Dtr, Shifting Of Existing 250 Kva Dtr From Bed To Pole Mounted, L T Line, Civil Works , Ct Pt Combined Unit For Providing Sop To Water Supply Scheme Gharahan, Water Supply Scheme Pipli Kathwari, Water Supply Scheme Rathore (Ms-14) Stage-I & Ii Located At Village Chandyal And Village Pipali Kathwadi( For 3.73+14.91 =18.64 Kw Load Of Stage-Ist At Chandiyal )& (29.43 Kw Load Of Stage-Ii At Pipli) In Es Gagal Under Esd Hpsebl Nerchowk
BOQ
| Sl. No. | Item Description |
| 1 | Supply Part of 63 KVA Transformer at Chandyal on H T line Four pole structure |
| 2 | Prov. 11 KV CT-PT unit outdoor type , PT(1 Unit , 11 KV/110 V):CT:10-400/5A) |
| 3 | Prov. 3-Phase 3/4 wire CT-PT Operated static trivector meter (DLMS Complaint) |
| 4 | i) PVC Multistrand 4 sqr mm copper wire |
| 5 | ii) 1 inch dia GI pipe for concealing |
| 6 | iii) bend joints/ elbow |
| 7 | CT-PT Belting & Knee Bracing:- Prov. M.S.C.I. X-Arm (100x50x6 mm),Length 2800 mm X 2 Nos. For CT/PT |
| 8 | Prov. C.I. X-Arm (100X50x6 mm) length 460 mm X 2 Nos. for supporting Main Channel of transformer. |
| 9 | Prov. M.S. A.I X Arm (50x50x6mm) Length 2800 mm 2 Nos. |
| 10 | M.S. Angle Iron (35X35X5 mm), Length: 460 X 2 Nos. |
| 11 | M.S Angle Iron (50*50*6 mm) lenght:(950 mm) x 2 No.'s for Bed Knee Bracing |
| 12 | Prov. 63 KVA , 11/0.4 KV Transformer |
| 13 | Prov. M.S.C.I. X-Arm (100x50x6 mm),Length 2800 mm X 2 Nos. For incomer line |
| 14 | Prov. M.S. Angle Iron (50X50X6 mm), Length: 2800 X 1 Nos. For LA's |
| 15 | Prov. C.I. X-Arm (75X40x6 mm) length 2800 mm X 4 Nos. for supporting D O Fuse Unit & G O ABSwitch |
| 16 | Prov. M.S.C.I. X-Arm (100x50x6 mm),Length 2800 mm X 2 Nos. For Transformer Bed |
| 17 | Prov. C.I. X-Arm (100X50x6 mm) length 460 mm X 2 Nos. for supporting Main Channel of transformer. |
| 18 | Prov. M.S. A.I X Arm (50x50x6mm) Length 2800 mm 2 Nos. |
| 19 | M.S. Angle Iron (35X35X5 mm), Length: 460 X 2 Nos. |
| 20 | M.S Angle Iron (50*50*6 mm) lenght:(950 mm) x 2 No.'s for Bed Knee Bracing |
| 21 | M.S. Angle Iron (50X50X6 mm), Length: 2800 X 2 Nos. |
| 22 | M.S. Angle Iron (50x50x6mm), Length: 450 X 1 Nos. |
| 23 | GO Switch handle suppourting channel Iron (75*40*6mm) lenght 460 mm |
| 24 | Prov. G.O. AB Switch Unit ( 11 kV, 400A, 25kV) |
| 25 | Prov. D.O.Fuse Unit |
| 26 | Prov. Surge Arrester,9 kV Station Class (Porcilain Type) L.A. |
| 27 | Prov. 11 kV Disc Insulator set (Comprising 1 No. Disc. (Porcilain, BS, 12kV,90kN) i/c Dead End Clamps etc.) |
| 28 | Prov. Stay Set complete |
| 29 | Prov. Stay Wire 7/3.15 mm ( @ 7.0 kg Per Stay Set) |
| 30 | Prov. Pipe Earthing |
| 31 | Prov. 6 SWG GI Wire for earthing |
| 32 | Prov. ACSR 6/1/4.72 Sqr mm for Jumpering |
| 33 | Prov. LT Distribution box for 63 KVA DTR with MCCB 100A 3P 35 KA , ICS=100 % ICU , KIT KAT 200 A |
| 34 | Prov. Half Clamps (M.S. Flat 50X6 mm) |
| 35 | Prov. Full clamps (M.S Flat 50x6 mm) |
| 36 | Prov. M.S. Nuts and Bolts of various sizes (galvanised/ Coated) (Preferably 16 mm ɸ or more (With Flat & Spring Washers)) |
| 37 | Prov. Aluminium. Thimble |
| 38 | Copper. Thimble 95 mm2 |
| 39 | Prov. Danger Plate |
| 40 | Prov. Barbed wire |
| 41 | Prov. LT Cable (3.5 Core) 120 mm2 |
| 42 | Prov. Aluminium Paint. |
| 43 | Prov. Red oxide |
| 44 | Switched capacitor 27 KVAr |
| 45 | Erection Charges of 63 KVA DTR at Chandyal |
| 46 | Errection Charges of Transformer including CT /PT Unit (Complete in all respect) |
| 47 | Transportation charges for transformer all material required |
| 48 | Supply Part of 63 KVA Transformer at Peepli Kathwadi |
| 49 | Prov. 11 KV CT-PT unit outdoor type , PT(1 Unit , 11 KV/110 V):CT:10-400/5A) |
| 50 | Prov. 3-Phase 3/4 wire CT-PT Operated static trivector meter (DLMS Complaint) |
| 51 | i) PVC Multistrand 4 sqr mm copper wire |
| 52 | ii) 1 inch dia GI pipe for concealing |
| 53 | iii) bend joints/ elbow |
| 54 | Prov. M.S.C.I. X-Arm (100x50x6 mm),Length 2800 mm X 2 Nos. For CT/PT |
| 55 | Prov. C.I. X-Arm (100X50x6 mm) length 460 mm X 2 Nos. for supporting Main Channel of transformer. |
| 56 | Prov. M.S. A.I X Arm (50x50x6mm) Length 2800 mm 2 Nos. |
| 57 | M.S. Angle Iron (35X35X5 mm), Length: 460 X 2 Nos. |
| 58 | M.S Angle Iron (50*50*6 mm) lenght:(950 mm) x 2 No.'s for Bed Knee Bracing |
| 59 | Prov. 63 KVA , 11/0.4 KV Transformer |
| 60 | Prov. S/T Pole 9 Mtr. Long |
| 61 | Prov. RCC Muff with C:C filling 2000 mm length |
| 62 | Prov. M.S.C.I. X-Arm (100x50x6 mm),Length 2800 mm X 2 Nos. For incomer line |
| 63 | Prov. M.S. Angle Iron (50X50X6 mm), Length: 2800 X 1 Nos. For LA's |
| 64 | Prov. C.I. X-Arm (75X40x6 mm) length 2800 mm X 4 Nos. for supporting D O Fuse Unit & G O ABSwitch |
| 65 | Prov. M.S.C.I. X-Arm (100x50x6 mm),Length 2800 mm X 2 Nos. For Transformer Bed |
| 66 | Prov. C.I. X-Arm (100X50x6 mm) length 460 mm X 2 Nos. for supporting Main Channel of transformer. |
| 67 | Prov. M.S. A.I X Arm (50x50x6mm) Length 2800 mm 2 Nos. |
| 68 | M.S. Angle Iron (35X35X5 mm), Length: 460 X 2 Nos. |
| 69 | M.S Angle Iron (50*50*6 mm) lenght:(950 mm) x 2 No.'s for Bed Knee Bracing |
| 70 | M.S. Angle Iron (50X50X6 mm), Length: 2800 X 2 Nos. |
| 71 | M.S. Angle Iron (50x50x6mm), Length: 450 X 1 Nos. |
| 72 | GO Switch handle suppourting channel Iron (75*40*6mm) lenght 460 mm |
| 73 | Prov. G.O. AB Switch Unit ( 11 kV, 400A, 25kV) |
| 74 | Prov. D.O.Fuse Unit |
| 75 | Prov. Surge Arrester,9 kV Station Class (Porcilain Type) L.A. |
| 76 | Prov. 11 kV Disc Insulator set (Comprising 1 No. Disc. (Porcilain, BS, 12kV,90kN) i/c Dead End Clamps etc.) |
| 77 | Prov. Stay Set complete |
| 78 | Prov. Stay Wire 7/3.15 mm ( @ 7.0 kg Per Stay Set) |
| 79 | Prov. Pipe Earthing |
| 80 | Prov. 6 SWG GI Wire for earthing |
| 81 | Prov. ACSR 6/1/4.72 Sqr mm for Jumpering |
| 82 | Prov. LT Distribution box for 63 KVA DTR with MCCB 100A 3P 35 KA , ICS=100 % ICU , KIT KAT 200 A |
| 83 | Prov. Half Clamps (M.S. Flat 50X6 mm) |
| 84 | Prov. Full clamps (M.S Flat 50x6 mm) |
| 85 | Prov. M.S. Nuts and Bolts of various sizes (galvanised/ Coated) (Preferably 16 mm ɸ or more (With Flat & Spring Washers)) |
| 86 | Prov. Aluminium. Thimble |
| 87 | Copper. Thimble 95 mm2 |
| 88 | Prov. Danger Plate |
| 89 | Prov. Barbed wire |
| 90 | Prov. LT Cable (3.5 Core) 120 mm2 |
| 91 | Prov. Aluminium Paint. |
| 92 | Prov. Red oxide |
| 93 | Switched capacitor 27 KVAr |
| 94 | Erection Charges of 63 KVA DTR at Peepli Khatwadi |
| 95 | Errection Charges of Transformer including CT /PT Unit (Complete in all respect) |
| 96 | Transportation charges for transformer all material required |
| 97 | Supply Part of Existing 250 KVA,11/0.4 KV DTR at chandyal to be re-erected on pole mounted from DTR Bed |
| 98 | Prov. M.S. Angle Iron (50X50X6 mm), Length: 2800 X 1 Nos. For LA's |
| 99 | Prov. C.I. X-Arm (75X40x6 mm) length 2800 mm X 4 Nos. for supporting DO Fuse Unit & G O ABSwitch |
| 100 | M.S. Angle Iron (125X65X6 mm), Length: 2800 X 2 Nos. |
| 101 | M.S. Angle Iron (125x65x6mm), Length: 450 X 1 Nos. |
| 102 | Prov. M.S. A.I X Arm (50x50x6mm) Length 2800 mm 2 Nos. |
| 103 | M.S. Angle Iron (35X35X5 mm), Length: 460 X 2 Nos. |
| 104 | M.S Angle Iron (50*50*6 mm) lenght:(950 mm) x 2 No.'s for Bed Knee Bracing |
| 105 | GO Switch Handle Supporting: [Channel Iron (75x40x6 mm), Length : 460 mm |
| 106 | GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type |
| 107 | D.O Fuse Unit |
| 108 | Surge Arrester, 9 kV Station Class (Porcelain Type) |
| 109 | Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) |
| 110 | Stay set complete |
| 111 | Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set) |
| 112 | Pipe Earthing Set |
| 113 | Prov. GI wire 6 SWG for earthing |
| 114 | Prov. ACSR 6/1/4.72 Sqr mm |
| 115 | L.T. Distribution Penel Box with MCCB (with copper thimbles of 200A, Insulating sleeves etc. MCCB 400 amp ,50kA, 3P- 1 No. ICS 100% ICU % MCCB 250 Amp 36kA=3 nos) and SFU (32A. 5No. rewirable). |
| 116 | Half Clamp (M.S. Flat 50X6 mm) |
| 117 | Full Clamps (M.S. Flat 50X6 mm) |
| 118 | Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16mm Φ or more (with flat and spring washers)] |
| 119 | Aluminium Thimble |
| 120 | Copper Thimble |
| 121 | Danger Plate |
| 122 | Barbed Wire |
| 123 | Prov. LT XLPE Cable (3.5 Core) 240 mm2 |
| 124 | Erection Charges of existing 250 KVA DTR Transformer from DTR Bed to Pole mounted |
| 125 | Errection of existing 250 KVA DTR Transformer from DTR Bed to Pole mounted (Complete in all respect) |
| 126 | Transportation charges for transformer all material required |
| 127 | Supply Part of HT Line |
| 128 | Prov. Steel Tubular Pole 9.00 mtr long |
| 129 | Prov. Steel Tubular Pole 11.00 mtr long |
| 130 | Prov. RCC Muff with Concrete Filling 2000mm length. |
| 131 | 11kV Covered Conductor XLPE Sheath Material , (AAAC, 12kV, 245 Amps, 70mm²) [EN 50397-1:2006] |
| 132 | Prov. AAAC Cond.7/3.15 mm2 (50 sqr mm ) |
| 133 | Prov. G.I.No. 6/ 8 SWG for Earth wire for PCC & S/T Pole( including for guarding) |
| 134 | Prov. 11 KV Pin Insulator with Pin Hellically formed fitting (Porcelain, 12kV, 10kN) |
| 135 | Prov. 11 KV Disc Insulator Set Cleaves & Toungue Hellically formed fitting (Porcelain, BS, 12kV, 90kN) |
| 136 | Prov. C.I.X-arm (100x50x5mm), Length(1500) for S. Pole Str. |
| 137 | Prov. C.I. X-arm(75x40x6mm),Length: 2800 mm for D.Pole Str. GO Switch & Do Fuse |
| 138 | Prov. C.I. X-arm(100x50x5mm),Length: 2400 mm for D.Pole Str. |
| 139 | Prov. C.I. X-arm(100x50x5mm),Length: 2800 mm for D.Pole Str. |
| 140 | Prov. A.I.X-arm(50x50x6mm), Length:1800 mm.for Gaurding |
| 141 | Prov. A.I.X-arm(50x50x6mm), Length : 3000 mm.for Gaurding |
| 142 | Prov. A.I.X-arm(50x50x6mm), Length : 2700 mm.for Gaurding |
| 143 | Prov. A.I Knee Bracing set (50x50x6mm), Length (2x750) for Single Pole |
| 144 | Prov. Belt Set (X-Bracing Set)M S A. Iron (50x50x6mm) Length:1800*2 mm |
| 145 | Prov. Belt Set (X-Bracing Set)M S A. Iron(50x50x6mm) Length: 2700x2 mm |
| 146 | Prov. G.O Switch Handle Suppourting channel 75*40*6 Length 460 mm |
| 147 | Prov. Stay Set Complete in all respect i/c Guy Assembly with Helically Fitting |
| 148 | Prov. Stay Wire 7/3.15 mm/ 7.400 mm ( @ 6.0 KG /9.00 Kg per Stay Set) |
| 149 | Prov. H.T. Earthing for PCC /S/T Pole |
| 150 | Prov. Full Clamp with nuts & bolts M.S. Flat 50x6 mm |
| 151 | Prov. Half Clamp with nuts & bolts M.S. Flat 50x6 mm |
| 152 | Prov. Pole Top Clamp with nusts & bolts M.S .Flat-do- |
| 153 | Prov. Earth Hook for Earth Wire |
| 154 | Prov. Danger Plate (250x200x1.6 mm) |
| 155 | Prov. Nuts & Bolts Of various sizes ( Gaivanised/ Coated) ( Preferably 16 mmɸ or more with flat and spring washers) |
| 156 | Prov. Barbed Wire |
| 157 | Prov. Alluminium Paint |
| 158 | Prov. Red oxide |
| 159 | Prov. 11 KV G.O. AB Switch Unit (11 KV, 400A, 25 KA |
| 160 | Prov. 22 KV G.O. AB Switch Unit (11 KV, 400A, 25 KA |
| 161 | Providing Fault Path Indicator ,7kV - 69kV ,at various spur of 11 KV line |
| 162 | Providing 22 kV Auto Recloser , Auto Recloser(interruption: Vaccum, Insulation: Solid Dielectric, with C/R Panel and without Communication) etc |
| 163 | Providing Dell/HP AIO Desktop with: Intel Core i5-14500T-14th Gen Processor, 8GB DDR4 RAM expandable upto 16GB 512GB SSD, 23\\" LED Color display with FHD (1920×1080) Integrated HD Graphic & webcam, 2xUSB 3.0, 2xUSB 2.0, Audio jack/ VGA/ HDMI/ DP port, 10/100/1000m IPV6 compliant LAN, USB Keyboard & Mouse, internal speaker, 1x802.11b/g/n/ac, PL-Windows10 Pro 64bit O.S |
| 164 | Prov. HP Monochrome Multi Function Laser Printer HP Laser MFP 1188A Printer – A4 Size Paper, Printing Speed 20PPM, Resolution 1200Dpi, Memory 128MB, Copy Speed (Mono) 20CPM, Scan speed Black and Color 6PPM & 3PPM, USB 2.0, Paper Tray Capacity 150 pages. |
| 165 | Erection of HT line |
| 166 | Erection of ST pole 9.00/10.00/11.00 mtr ,muff i/c CC muffing with 1:2:4 ratio, CI-X-arm 2800*100*50mm /1500*100*50mm for double pole structure , drilling of holes in pole & -X-arm etc, disc insulators with complete fitting, pin insulator with pin, AI - |
| 167 | Erection of ST pole ,muff i/c CC muffing with 1:2:4 ratio, CI-X-arm 1500*100*50mm for Single pole str , drilling of holes in pole , pin insulator with pin, knee bracing set, barbed wire, danger plate, MS full clamps,top clamp, nuts & bolts off sizes, |
| 168 | Erection of HT stay set, stay wire, stay clamp, egg insulator, digging of pit, filling & ramming, fixing of stay rod, nozzeling & tightening etc. complete in all respect. |
| 169 | Erection of HT earthing (pipe earthing) set complete in all respect, digging of earth pit, filling of pit with required material and ramming complete in all respect. |
| 170 | Erection/Sagging of 11kV Covered Conductor XLPE Sheath Material ( Laying & Sagging complete in all respect ) as per cost Data 2025-26. |
| 171 | Erection , Laying of ACSR 50mm2 i/c stringing, sagging, binding with insulators and jumpering etc. complete in all respect. (Singl wire conductor)(Complete in all respect) |
| 172 | Erection, Laying of G.I. Wire 6/8 SWG i/c stringing, sagging and binding with earth hook bolt for continious earth wire complete in all respect. (Complete in all respect) |
| 173 | Erection Charges for G.O Switch, & D.O fuse and Fault Path Indicator |
| 174 | Erection Charges for Auto Recloser comlete in all respect |
| 175 | Transportation charges for transformer all material required |
| 176 | Supply Part of LT Line |
| 177 | Prov. Steel Tubular Pole 9.00 mtr Working Load >180 Kgf/m2 |
| 178 | Prov. Steel Tubular Pole 10.00 mtr Long |
| 179 | Prov. R.C.C. Muff (2000 mm) with C. C. 1:2:4 for filling |
| 180 | Prov. XLPE Cable 95 sqr mm |
| 181 | Prov. AAAC 7/3.81 (80 mm 2 ) |
| 182 | Prov. GI Wire 8 SWG |
| 183 | Prov. A.I Knee Bracing set (50x50x6mm), Length (2x750) for Single Pole |
| 184 | Prov. C.I.X-arm (100x50x6mm), Length(600) for S. Pole Str. |
| 185 | Prov. Messanger wire for XLPE Cable considering 0.425 Kg per meter (175mtr*0.425 Kg/Mtr=75Kg) ( Stay wire) |
| 186 | Clamps for holding XLPE Cable and messanger wire |
| 187 | Prov. Shackle Insulaotrs |
| 188 | Prov. D-Iron |
| 189 | Prov. L.T Stay Set |
| 190 | Prov. Stay Wire 7/3.15 mm (@7.0 kg per stay set) |
| 191 | Prov. L.T.Stay clamp |
| 192 | Prov. Earth Knoob |
| 193 | Prov. L.T. Earthing |
| 194 | Prov. M.S. Nuts & Bolts off size |
| 195 | Prov. Aluminium Paint |
| 196 | Prov. Red oxide |
| 197 | Prov. L.T. Spacer For 3Ø L.T. Line |
| 198 | Erection of LT line |
| 199 | Erection erection of steel poles 8/9 Mtrs long, shackle insulator with D-iron eye hook, digging of pole pit size 1.20x0.80x1.35 filling and ramming & painting etc complete in all respect |
| 200 | Erection of LT stay set, stay wire, stay clamp, egg insulator, digging of pit, filling & ramming, fixing of stay rod, nozzeling & tightening etc. complete in all respect. |
| 201 | Erection of LT earthing set complete in all respect, digging of earth pit, filling of pit with required material and ramming complete in all respect. |
| 202 | Add Erection Charges Laying of conductor,Stringing & Sagging of conductor & binding with insulator single ACSR/AAAC (80/100mm2) as per cost Data 2023-24. ( single conductor P/ Km) |
| 203 | Erection/Sagging charges of G.I. wire (laying , stringing & sagging & binding with insulator) as per cost data 2023-24 |
| 204 | Transportation Charges for LT line |
| 205 | Civil Work (i.e Chain link fencing angle iron gate etc. of 250 KVA DTR) |
| 206 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. |
| 207 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand) : 8 graded stone aggregate 40 mm nominal size) |
| 208 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement: 1½ coarse sand) : 3 graded stone aggregate 20 mm nominal size) |
| 209 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 210 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. Made of G.I. wire of dia 4 mm |
| 211 | Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc. complete :100x58x1.90 mm |
| 212 | Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete :250x16 mm Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender