Tender For special Repair To Building No A/4/71 (Toilet Block), Provn Of Floor And Wall Tile At Fd Wksp, Provn Of Hardstanding Near Fd Wksp Gate Of Eme Bn (Area 450 Sqm Approx) And Provn Of Kota Stone Tiling With Overhead Shed And Wire Mesh In Cook H
Tender Overview
Project Description
Tender for special Repair To Building No A/4/71 (Toilet Block), Provn Of Floor And Wall Tile At Fd Wksp, Provn Of Hardstanding Near Fd Wksp Gate Of Eme Bn (Area 450 Sqm Approx) And Provn Of Kota Stone Tiling With Overhead Shed And Wire Mesh In Cook House Under Ge Panagarh
BOQ
| Sl. No. | Item Description |
| 1 | Demolition of PCC in ground floors & pavings n exc 15 cm thickness (below or above ground level) (unreinforced) complete all as specified and directed. |
| 2 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. complete all as specified and as directed. |
| 3 | Demolition of reinforced cement concrete in ground floors and pavings n.exc 15 cm thickness (below or above ground level) and removal of the rubbish off the premises all as specified and directed. |
| 4 | Excavating in trenches , n.exc 1.5 m wide and n.exc 1.5 m depth for foundation etc or for shafts, wells, cesspits ,manhole pier hole, laying of cables, pipes etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in any kind of soil. complete all as specified and directed.Note : Manual excavation to be done. During excavation if any damage occured to existing cable any type/ water pipe line, it will be contractor responsibilty to get it repair and make functional by providing jointing kit etc without any extra cost. Contractor has to repair it within 24 hrs so that essential service can not be effected due to such damage.If contractor fails to repair it within 24 hrs penalty @ Rs 500/- will be charged to contractor. In this GE decision will be final, conclusive and binding. |
| 5 | Excavation over area n.exc 1.50m deep and getting out soft/loose soil complete all as spd and directed. |
| 6 | Returning filling in soft /loose excavated soil including spreading leveling watering and well ramming in layers not exceeding 25 CM and all as specified and directed. |
| 7 | Removing excavated material (soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed. |
| 8 | M&L for rolling and consolidating road formation surfaces in cutting with 8 to 12 tonne power roller complete all as spd and directed. |
| 9 | M&L for pavings, with mix of fly ash, clinker & stone dust in the proportion of 1:3:6 (ie 10% fly ash, 30% clinker and 60% stone dust ) laying in layers n. exc 10cm thick, watering, ramming and compacted with hand/power roller 8 to 12 tonn roller to required camber and gradient complete all as directed by Engineer-in-Charge. |
| 10 | M&L for 150mm thick(compacted thickness)(75mm each layer) WBM, with coarse aggregates (basalt type of aggregate) of grading 2 (63 to 40mm size) or of grading 3 (50 to 20mm size), spread, rolled and consolidated to gradient and camber required with preparing unsurfaced WBM by brushing with wire brushes for removing mud etc, sweeping with brooms and finally fanning the cleaned surface with gunny bags to remove all loose dirt etc complete all as specified and as directed. |
| 11 | M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 12 | M&L for hardcore of broken stone or boulder of gauge exc 63mm but n.exc 75 mm deposited, spread & leveled in lyers n.exc 15 cm thick watered & rammed to a true surface Complete all as specified and directed. |
| 13 | M & L for Plain Cement Concrete Type D2 1:4:8 (using 40 mm graded crushed stone aggregate) as in foundation and mass filling Complete all as specified and directed. |
| 14 | M & L for PCC (1:3:6) Type C2 using 40 mm graded crushed stone aggregate as in foundation and mass filling, sub base floor/pavings and finishing complete all as specified and as directed. |
| 15 | M&L for M-25 Design mix using 20mm graded crushed stone aggregate as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concret Complete all as specified and directed. |
| 16 | M&L for M-25 Design mix using 20mm graded crushed stone aggregate as in Beams, cantilevers, bressummers, lintels over 1.5m span Complete all as specified and directed. |
| 17 | M&L for M-25 Design mix using 20mm graded crushed stone aggregate as in Columns, pillars, piers, posts and struts Complete all as specified and directed. |
| 18 | M&L for M-25 Design mix using 20mm graded crushed stone aggregate as in chajjas Complete all as specified and directed. |
| 19 | M&L for damp proof course 40mm thk M-20 (Nominal Mix) using 12.5mm graded crushed stone aggregate with water proofing compound conforming to IS-2645 liquid grade as per manufacturer’s instructions with and including polythene film 200 micron over and including 85/25 grade Industrial bitumen (IS-702 : 1988) @ 1.5 kg/sqm blended with the dry sand @ 0.05 cubic meter/ sqm. complete all as specified and directed. |
| 20 | M&L for providing RCC precast cement concrete type B-0 (1:2:4) (using 12.5 mm graded crushed stone aggregate as in cover slab for manhole and similar article with plain face set in cement mortar (1:4) complete all as specified and directed. |
| 21 | M&L Plain Cement Concrete 1:3:6 type C1 (using 20 mm graded crushed stone aggregate) as in surface channels and drains, complete all as specified and directed. |
| 22 | M&L for Steel Centering and shuttering including strutting, propping etc. and removal of form to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter. complete all as specified and directed. |
| 23 | M&L for Steel Centering and shuttering including strutting, propping etc. and removal of form to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc for fair finished surface of concrete Complete all as specified and directed. |
| 24 | M&L for Steel Centering and shuttering including strutting, propping etc. and removal of form to sides of pillars, posts, struts, piers, columns and stanchions for fair finished surface of concrete Complete all as specified and directed. |
| 25 | M&L for Steel Centering and shuttering including strutting, propping etc. and removal of form to chullah hoods, chajjas, troughs and similar items including ege for fair finished surface of concreted Complete all as specified and directed. |
| 26 | M&L for TMT steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 27 | M&L Mild steel TMT bars 6mm to 8 mm dia, cut to length, bent to shape required, including cranking, bending pirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 28 | M&L for TMT steel bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 29 | M&L for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 30 | S & F for Roof trusses Fe - 410-W (Gde E-250) Quality B (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats, bolting etc. all as directed and as specified. |
| 31 | S&F rolled mild steel in plates channel (plain or chequred) square cut or notched (ordinary and counter shunk)forming holes, withpout any attachment of quality FE 410-W (Gde-E-250)quality-B complete all as specified and directed. |
| 32 | S&F Mild steel screw bolts (machine made) with hexagonal or squareheads at one end and screwed the other, or screwed both ends, eachscrewed end to be fitted with washers and one hexagonal or squarenut, exc 5cm but n.exc 10cm long (16 to 20mm dia), all as specified and as directed. |
| 33 | M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated of any profile steel sheet corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified up to anyheight including all necessary scaffolding and safety measures complete all as specified and directed |
| 34 | M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in ridge/ valley/ gutter fixed with self tapping screws as specified any height Mtr height including all necessary scaffolding and safety measures complete all as specified and directed |
| 35 | M/L brick work with flyash bricks old size straight or curved on plan to any radius exc 6m mean radius build in CM 1:6 complete all as specified and directed. |
| 36 | M&L for brick work with fly ash bricks old size, straight or curved on plan exc 6m mean radius, in half brick walls built in cement mortar 1:4 complete all as specified and directed. |
| 37 | Cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar 1:3 and cutting chases for concealed water tubing and making good of groves for concealed GI/PVC tube, cutting not exc 10cm girth complete all as specified and as directed. |
| 38 | Taking down chowkat or frames exc 1.5 sqm but n exc 4.0 sqm each with shutter (without taking off shutters from the frame) and removing to or from store complete all as specified and as directed. |
| 39 | Taking down Chowkats or frames not exc. 1.5 sq. m each with shutters (without taking off shutters from the frames) and removing to or from store complete all as specified and as directed. |
| 40 | S&F solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplying and fixing in opening as per specification and drawing complete all as specified and directed. |
| 41 | S&F for Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 50X100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardan and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made complete all as specified and as directed. |
| 42 | S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet trip of 20mm with stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement, supplying and fixing in the frame at site as per specification and drawing complete all as specified and directed. |
| 43 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid decorative panelled decorative flush door shutter one side plain on other side of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. (Note: stainless steel butt hinges and necessary S S screws shall be paid separately) complete all as specified and as directed. |
| 44 | S&F factory made single extruded WPC (Wood Polymer Composite) wire gauzed i.e. panel shutter will be wire mesh in lieu WPC , the wire gauze shall be warped on additional square 8mm MS Solid tube and this tube shall be welded to MS frame complete all as specified and as directed. |
| 45 | S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators frame and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per the directions of Engineer-in-Charge |
| 46 | S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-chargeher for openable/sliding shuttters) including all necessary fittings as directed |
| 47 | S&F 100 mm butt hinges,extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-22,complete all as specified and directed. |
| 48 | S&F aluminium anodised 150 mm barrel tower bolts of extruded section complete all as specified and directed. |
| 49 | S&F 150 mm long extruded aluminium alloy handles,fabricated type, anodised complete all as specified and directed. |
| 50 | S&F Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, complete all as specified and directed. |
| 51 | Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 52 | M&Lfor 75 mm thick, Cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate), as in sub base complete all as specified and directed. |
| 53 | M&L for 75 mm thick PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in floor with nominal reinforcement finished even and fair complete all as specified and directed.(Reinforcement bar will be measured and paid separately) |
| 54 | M&L Machine Cut Kota Stone Slab 18-20mm thick as in Floor, etc. over and including Screed Bed or Bedding Layer 20mm thick in Cement Mortar (1:6), Laid and Jointed with Grey Cement Slurry mixed with Pigment to match the Shade of the Slab including Rubbing and Polishing, complete all as specified and as directed. |
| 55 | M&L for 25 mm thick PCC 1:2:4 type B-0 (Using 12.5mm graded crushed stone aggregate) as in floor, finished the surfaces fair & even to receive next layer, complete all as specified and directed. |
| 56 | M&L Non Skid ceramic coloured tiles 7 to 8mm thick (squares/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors/skirting etc. laid over 15mm thick 1:6 cement mortar screed bed set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 57 | M&L Non Skid coloured ceramic tiles 7 to8 mm thick (Square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm on vertical surface such as skirtings etc. set and jointed in cement slurry over 10 mm thick rendering in CM 1:3 complete all as specified and directed.complete all as spd and as directed. |
| 58 | M&L for Glazed ceramic tiles Coloured 350 x 250mm/450 x 300mm 7 to 8 mm thick in wall/dado etc, set & jointed in neat cement slurry & pointed in white or coloured cement to match rendering over 10 mm thick in CM 1:3 on stone masonry surfaces or surfaces other than fair face of brick work/ concrete surfaces complete all as specified and directed. |
| 59 | M&L for Green marble work 15 mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade of following typesnt with admixture of pigment to match the shade of granite stone including grinding and polishing complete over and including 15mm thick Screed bed or backing coat for laying floor finishes in CM 1:6 complete all as specified. |
| 60 | Rounding to edges of stone slabs one edge, such as in steps, cooking platform, granite/kota stone and other similar situations incl polishing, complete all as specified and directed. |
| 61 | M&L for 75 mm thick cement concrete M10 (Nominal Mix) with 40mm graded crushed aggregate finished even and fair laid to a slope of 1 in 12, laid in alternate bays, each bay not exceeding 3 m length with joint filled with bituminous mastic filling comprising a mixture of 1 part of heated Industrial bitumen 85/25 grade and two parts of heated sand as in plinth protection complete all as specified |
| 62 | M&L for pre-polished factory made 80mm thickness precast concrete interlocking paver block any size and shape with grey cement and pigment confirming to IS 15658-2006 of M-40 Grade complete all as specified and directed |
| 63 | M&LProviding and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified as directed. |
| 64 | Taking down cement plaster on brick or stone wall etc. including racking out joints hacking for key scrubbing down with water etc complete all as specified and as directed. |
| 65 | M&L for rendering 15 mm thick on other than fair faces of brick work or concrete surfaces, finished fair and even on walls in cement mortar (1:6), complete all as specified. |
| 66 | M&L for Rendering 15 mm thick cement plaster in CM 1:4 on fair faces of brick/concrete surfaces finished fair and even, mixed wth water proofing compound admixture (if directed) as per manufacturer's instruction, complete all as specified and directed.Note :- WPC will measuered and paid separatly under relevant item of schedule. |
| 67 | M&L for Rendering 10 mm thick in CM 1:4 finished even and fair on vertical surfaces on wall to receive wall tiles,complete all as specified and directed. |
| 68 | Supply only intergral water proofing compound (liquid admixture) complete all as specified and directed. |
| 69 | M&L for prepartion of old surface and applying two coats of Super Latex (Sika or equivalent) @ 80gm per sqm per coat in the ratio of 1:1.5:5 (latex : water : cement) over internal/external of brick/concrete surface after cleaning and washing the surface by wire brush and plenty of water The entire surface shall be washed throughly with plenty of water and then allowed to dry complete all as specified and as directed. Note:- The entire process to be executed through authorised applicator. |
| 70 | M&L for repair to crack portion with jacktting technuque, taking down existing plaster up to brick wall surface of min 200 mm wide, cleaning to loose particles on surface of brick work along the length of crack and filling the gap/crack area with PCC 1:1.5:3 type A0 using 12.5 mm aggregate up to brick surface and inserting the welded mesh of size 25 x 25x 2 mm dia along the crack on both side of the wall surface fixed with, drilling holes 10 mm dia on either side of the crack by means of drilling machine through out the full width of the wall @ 25 cm c/c and insert 8/10 mm dia rod in the drilled holes, welded with horizontal rod to with hold the welded mesh and applying grit plaster 1:1:2 using 4 mm and down aggregate finished even and smooth without using extra cement complete all as specified and directed. (Note: Reinforcement and welded mesh will be measured and paid separately ) |
| 71 | Material & labour preparation of newly plastered surfaces of wall and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces on external surface complete all as directed by Engineer-in-charge |
| 72 | Material & Labour for preparation of new surfaces of plastered walls and applying Two coats of Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. over and including a coat of primer over plastered surfaces of walls complete all as specified . . |
| 73 | M&L for preparing of new steel & iron surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enameled paint over a coat of Red oxide zinc chrome primer zinc chrome complete all as specified and as directed. |
| 74 | M&L for preparation of concrete kerb stone or plaster surface of any description not otherwise described over 10cm width or girth and applying two coat of water based floor coat paint emulsion over one coat of self priming coat emulsion by diluting with 30% to 40% water complete all as specified and directed by Engr-in-Charge. |
| 75 | S&F Sheet glass, 3mm thick pin headed quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and directed. |
| 76 | M&L for 4mm thick figured glass, pin head type and glazing with oil putty in square n. exc 0.5 sqm in each pan for bathrooms/toilets ventilators all as directed |
| 77 | S&F in repairs Gun metal, globe or gate valve with iron wheel head, 20 mm bore, screwed both ends for pipe complete all as specified and as directed. |
| 78 | S&F in repair CP Bib taps 15mm dia, with cfancy handle, screwed down, screwed for iron pipe or for brass ferrule, fency type and fixed complete all as specified and directed. |
| 79 | S&F in repair Stop valve cast copper alloy screwed down high pressure with capston headed handle chromium plated concealed type screwed both ends for pipe 15 mm bore or for unions complete all as specified and as directed. |
| 80 | S&F in repaie fancy,chromium plated Stop valves 15mm dia, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed. |
| 81 | S&F in repair angle cock 15 mm bore fancy type chromium plated, with capstan head, high pressure, screwed down, screwed for iron pipe or for brass ferrule fixed to iron pipe complete all as specified and as directed. |
| 82 | S&F in repair 15mm bore pillar taps cast copper alloy,with capstan heads,chromium plated,screwed down, fancy type high pressure, with or without lettred 'HOT orCOLD' with long screwed sunk and fly nuts complete all as specified and directed. |
| 83 | S&F in repairs Vitreous china wash basin, white, flat back, size 550x400mm excluding taps, waste, chain and plug and porcelain stopper but including brackets and 32mm bore GI pipe light grade complete all as specified and as directed. |
| 84 | S&F in repair soap dish, any type fixed to plugs chromium plated brass screws complete all as specified and as directed. |
| 85 | S&F in repair glass self assembly consisting of 5.5 mm thick glass sheet glass self 12 Cm wide with CP bracket gaurd and railing 60 Cm long complete all as specified and as directed. |
| 86 | S & F in repairs vitreous china squatting pan, 'Orissa\\" pattern, size 580 mm X 440 mm white with ‘P’ or ‘S” trap, front or back inlet and integral foot rests, any pattern and including fixing , connector to flush pipe, lime concrete bedding and making connections to flush pipe, connector to branch pipe and anti syphonage pipes etc. including sealing the joints and making leak proof using sealant complete all as specified and as directed by Engineer-in-Charge. |
| 87 | S & F in repairs vitreous china wash down water closet (pedestal pattern), white including thermoplastic seats and covers of grade 2 type, flat with hinging device of bronze or brass with nickel chromium plating, fixing bolt, connector to flush pipe and making connections to flush pipe, connector to branch soil pipe and anti syphonage pipes etc. including sealing the joints and making leak proof using sealant complete all as specified and as directed by Engineer-in-Charge. |
| 88 | S&F in repairs PVC low level flushing cistern, 10 litres capacity, syphonic action type white body with inlet ball valve, float , handle, bracket, flush pipe etc complete & connecting to WC complete. complete all as specified and directed. |
| 89 | S&F in repair Vitreous china urinal, half stall type, white (excluding flushing cistern, flush pipe) including urinal spreader of PTMT any colour for fixing with 15mm dia pipe. (Minimum weight 60gms) and including waste pipe complete all as specified and directed. |
| 90 | S&F PVC connections 15 mm size with PTMT nuts of length 600mm complete all as specified and as directed. |
| 91 | S&F in repairs 32mm dia Waste coupling, brass , chromium plated for glazed ware , basins , etc. with long screwed shanks and fly -nuts , flange end bedded in red lead cement and other end fixed complete all as specified and as directed. |
| 92 | S&F in repairs grating square, Grating doom 125 mm dia with waste hole of PTMT. (Minimum weight 40gms), complete all as specified and directed. |
| 93 | Taking up or down 15mm dia GI steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed. |
| 94 | Taking up or down 20mm dia GI steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed. |
| 95 | S&F 16 mm outer dia medium grade CPVC, SDR 11 & plain CPVC SDR 11 with all fittings (brass inside the fittings) and fixed complete to walls and ceiling or laid in floors complete all as specified and directed. |
| 96 | S&F 20 mm outer dia medium grade CPVC, SDR 11 & plain CPVC SDR 11 with all fittings (brass inside the fittings) and fixed complete to walls and ceiling or laid in floors complete all as specified and directed. |
| 97 | Supplying and laying of PVC underground drainage sewer system pipe bearing 160 mm dia SN 4 including jointing with couplar, bend tee as per site requirement complete laid in trenches or floors complete all as specified and directed. |
| 98 | S&F PVC plain bend (any radius) for 75 mm bore, PVC pipes, complete all as specified and directed. |
| 99 | S&F 75mm bore PVC (SWR) junction single, (single T) equal or unequal fitted with oval access door, complete all as specified and directed. |
| 100 | S&F 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls including dismantling old unserviceable existing pipe with fittings, complete all as specified and directed. |
| 101 | S&F 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls including dismantling old unserviceable existing pipe with fittings, complete all as specified and directed. |
| 102 | S&F PVC (SWR) bends, plain, 110 mm bore any radius, complete all as specified and directed. |
| 103 | S&F 110 mm bore PVC (SWR) junction single (single T) equal or unequal fitted with oval access door, complete all as specified and directed. |
| 104 | Supply and fixing as in repair 110mm dia PVC(SWR) pipe fixed to wall or laid in trenches or in floors etc, including demolition complete all as specified and directed. |
| 105 | S&F in repair PVC door bends with oval access door (any radius) for 75 mm bore PVC pipes, complete all as specified and as directed. |
| 106 | S&F in repair PVC door bends with oval access door (any radius) for 110 mm bore PVC pipes, complete all as specified and as directed. |
| 107 | Taking down carefully point wiring for one light, socket or power etc incl all fittings such as switches sockets, holders, light fittings, fan requlators etc and making good the disturbed surface of wall, ceiling etc including seperating serviceabel light fittings, switches etc and keeping in safe custody for reuse and removal of unserviceable materials from site complete all as specified and directed. Please Enable Macros to View BoQ information |
| 108 | Taking down carefully point wiring for one light, socket or power etc incl all fittings such as switches sockets, holders, light fittings, fan requlators etc and making good the disturbed surface of wall, ceiling etc including seperating serviceabel light fittings, switches etc and keeping in safe custody for reuse and removal of unserviceable materials from site complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender