Tender For Addn/Altn And special Repairs To False Ceiling At Workspaces Of Groung And First Floor At Dmde Main Building.
Tender Value
48.40 Lakhs
Estimated cost
Bid Submission
19 Aug 2026
12 days left
EMD
96800
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Hyderabad → Telangana
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Addn/Altn And special Repairs To False Ceiling At Workspaces Of Groung And First Floor At Dmde Main Building.
BOQ
| Sl. No. | Item Description |
| 1 | Providing and fixing tiled Aluminium Ceiling Lay in false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams/sqm, both side inclusive) consisting of main “T” runner with suitably spaced joints to get required length and of size Silhouette grid 15X32mm made from 0.30mm thick (minimum) sheet, spaced at 1200 mm center to center and cross “T” of size 15X32mm made of 0.30mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600 mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600 mm and size 15X32mm made of 0.30mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 24X24 OR 20X20, 0.40mm and laying false ceiling tiles of approved texture in the grid including required cutting/making.Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 15mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in perforated BEVELLED MICRO TEGULAR EDGE global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation and backed with a black glass fiber acoustical fleece. Make: M/S. Diamond Ceiling or or Equalante |
| 2 | Providing and fixing tiled GI Metal Ceiling Lay in false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams/sqm, both side inclusive) consisting of main “T” runner with suitably spaced joints to get required length and of size Silhouette grid 15X32mm made from 0.30mm thick (minimum) sheet, spaced at 1200 mm center to center and cross “T” of size 15X32mm made of 0.30mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600 mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600 mm and size 15X32mm made of 0.30mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 24X24 OR 20X20, 0.40mm and laying false ceiling tiles of approved texture in the grid including required cutting/making.Main “T” runners to besuspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 15mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in perforated BEVELLED MICRO TEGULAR EDGE global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation and backed with a black glass fiber acoustical fleece. Make: M/S. Diamond Ceiling or or Equalante |
| 3 | M&L for providing and fixing Plaster of Paris false ceilings with light weight 19 mm thick Gypsum Board False Ceiling straight or curve any profile grid made from hot dipped GI steel section notary stitched double webbed power coated white consisting of main T- runner 42mmx14mm and 0.30mm thick and cross T of size 33mmx 14mm and 0.30mm thick placed at 60cm centre having width of flange 14mm with a 6mm reveal profile (Blace). The grid system to be rested on the periphery wall/partitions on a W-profile wall section made of pre-coated galvanized steel of dimension 3.0mm long x (15mm+10mm) x22.5mm and laying false ceiling for services like diffusers grill including cutting, making opening for services like diffusers grill light fitting, fixture smoke detectors etc. Wherever required main T-runner to be suspended from ceiling using GI suffix cleats of size 25mm x 35mm x 1.6mm fixed to ceiling with 6mm dia and 50mm long dash fastener, 4mm dia GI adjustable rods with galvanized level adjustment clips spaced as required, all complete at all height as per specification, drawing and as per direction of Engr in Charge and Including dismantliling of existing false celing at any specification and any height.. |
| 4 | M&L for complete removal of existing treatment from surfaces of walls/ ceiling, washing with water and applying two coats of Premium emulsion paint as per manufacturers instructions over a coat of primer over two coats of putty 1.5mm thick each layer each to level the surface and finished smooth with emery paper No.180 followed by emery paper No.320 or 400 and wipe it clean complete all as specified and as directed by Eng-in-charge. Note:- (i)The putty surface should be finished even smooth and dent free before application of primer, stage passing shall be taken for each building at every stage.. |
| 5 | NOTE FOR CONTRACTOR APPLICABLE TO ALL SCHEDULED ITEMS NO 01 TO ITEM NO 04 :1. Site will be given partly occupied condition.2. Work will be executed by strict timeline.3. Contractor, Supervisor and their labour should be provide police verification and proof of identity.4. Demolished material should be removed from site timely as per direction of JE. |
| 6 | M&L for point wiring complete with 1.5 Sqmm PVC insulated unsheathed single core multi standard FRLS copper conductor 1100 V grade drawn through in and including 20 mm dia PVC conduit concealed in walls/Ceiling and Terminated to sunken box of modular type including modular frame white cover plates suitable for fixing switches, sockets etc including 1.5 Sqmm PVC insulated Copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and directed for the following:- |
| 7 | a) One light/ Fan/ Bell point controlled by one way modular switch 6 Amps |
| 8 | b) One 3 pin 6 Amps switch socket outlet point on independent board |
| 9 | M&L for point wiring complete with 2.5 Sqmm PVC insulated unsheathed single core multi standard FRLS copper conductor 1100 V grade drawn through in and including 20 mm dia PVC conduit concealed on walls/Ceiling and Terminated to sunken box of modular type including white cover plates suitable for fixing switches, sockets etc including 1.5 Sqmm PVC insulated Copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and directed. |
| 10 | S&F modular switch one way 6 amps 1 module complete all as directed by Engineer-in-Charge. |
| 11 | S&F modular switch one way 16 amps 1 module complete all as directed by Engineer-in-Charge. |
| 12 | S&F modular socket out let 6 Amps 230 volts AC 3 pin multipurpose type complete all as directed by Engineer-in-Charge. |
| 13 | S&F modular socket out let 6A/16A - 2/3 pin combined 2 module, multipurpose type complete all as directed by Engineer-in-Charge. |
| 14 | S&F ceiling rose two to three terminal surface backallite type AC 50Hz 230 volts complete |
| 15 | Supply and fixing LED lights fitting 1x 20W, 220V, AC batten type fittings with extruded aluminium housing PC diffuser and integrated electronic driver connector block etc and connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. |
| 16 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC white recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete |
| 17 | Material and labour for earthing complete with galvanised mild steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level steel earth plate connected with GI wire 04 mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15 mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150 mm thick around GI earth plate, GI pipe medium grade 20 mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40 mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6 mm dia at the rate of 75 mm centre to centre both way with 12 mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40 mm x 40 mm x 3 mm frame for pit cover including testing on completion complete all as specified and directed. Please Enable Macros to View BoQ information |
| 18 | Material and labour for earthing complete with galvanised mild steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level steel earth plate connected with GI wire 04 mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15 mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150 mm thick around GI earth plate, GI pipe medium grade 20 mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40 mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6 mm dia at the rate of 75 mm centre to centre both way with 12 mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40 mm x 40 mm x 3 mm frame for pit cover including testing on completion complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 31, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 19, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysAug 21, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender