Defence Statutory Bodies & Commissions/Committees Closing in 4 days TDR #56783384

Tender For Name Of Work : Special Repair To Bldg No P-1300 And P-1301 (Sm Barrack And Toilet Block) At Field Regt Under Ge (A) Jaisalmer At Mil Station Jaisalmer

Issued by Statutory Bodies & Commissions/Committees · Jaisalmer, Rajasthan
Tender Value
70.78 Lakhs
Estimated cost
Bid Submission
28 Aug 2026
4 days left
EMD
1.32 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jaisalmer → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Name Of Work : Special Repair To Bldg No P-1300 And P-1301 (Sm Barrack And Toilet Block) At Field Regt Under Ge (A) Jaisalmer At Mil Station Jaisalmer

BOQ

Name of Work:- NAME OF WORK : SPECIAL REPAIR TO BLDG NO P-1300 AND P-1301 (SM BARRACK AND TOILET BLOCK) AT FIELD REGT UNDER GE (A) JAISALMER AT MIL STATION JAISALMER
Sl. No. Item Description
1M&L for preparation of new plastered surface and applying two coat of white or tinned with cement base paint over priming coat on exterior wall complete all as specified and directed by Engr-in-Charge.
2M & L for preparation of new plastered/concrete surfaces of walls, providing minumum 1mm thick Birla white wall care putty to achieve smooth surfaces and applying two coats of Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer,ofrequired shade and colour complete, as per manufacturer's specification. over a coat of compatiable priming paint complete all as specified.
3M&L for prepration of newly plastered surface and applying two coats of white wash on plastered surfacesof wall all as specified and directed.
4M&L for prepration of newly plastered ceiling surface and applying two coats of white wash on plastered surface all as specified and directed.
5Complete removal existing treatment and applying 1mm thick of Birla white wall care putty to achieve smooth surfaces and applying two coats of Oil Bound Distemper of approved shade/tint over a coat of compatiable priming paint complete all as specified and as directed.
6M&L for preparation of old plastered surfaces of ceiling and applying two coats of white wash complete all as specified and directed.
7M & L for preparation of old painted wooden surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
8M&L for preparation of old painted steel surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
9M&L for Chipping of slab/columns/ beams/chajjas /parapet /roof projection/ balcony/ staircase and removing loose mortar with chisel hammer without much impact on concrete surface, clean the surface by sand blasting the surface using river sand with minimum of 6 kg pressure at the nozzle or air blow by electric pressure blower by mechanical compressor, cleaning the exposed reinforcement with wire brushes etc and disposal of debris for all lead and lifts complete all as specified and directed by Engineer-in-Charge.Note :- Scaffolding/ temporary support structure required to support the members / structure during strengthening shall be measured and paid under Ser item No.1.
10M&L for applying bond coat on the prepared old surface of concrete/ masonry to receive micro concrete with two coats of Sika-Latex Super SBR or equivalent make of brand & as per manufacturer specifications. Laying of reinstatement polymer mortar or micro concrete shall be completed within the overlay time of bonding coat. This bond coat act as bonding agent between old and new concrete complete all as specified and directed by Engineer-in-Charge.
11M&L for applying to the damaged concrete portion of slab/columns/beams/chajjas/parapet /roof projection/balcony/staircase with single component, fiber reinforced, dual shrinkage- compensated thixotropic, cementitious patch repair mortar Sika monotop 122F (having the technical parameters mentioned in material specifications) capable of applying up to 20-25mm thick in double layer initially by hand and finishing with troweled carefully compacting the same around the rebar and finishing to bring it in line with existing concrete surface with an average specified thickness complete all as specified and directed by Engineer-in-Charge.
12Taking down cement plaster in cement or cement lime mortar on brick or concrete walls etc. including raking out joints, hacking for key, scrubbing down with water etc, Including removal of debries out side MoD land complete all as specified and as directed.
13M & L for rendering 15mm thick (In two layers) - first layhers 10mm thick with ready mix plaster and outer layer 5mm thick ready mix water proof plaster on outer wall by adding potable water by weight of material as mentioned by manufacture Ready mix plaster shall complies with IS 1661-1972, IS 2250-1981, IS 2402-1963 and shall confirms the compressive strength @ 28 days 10-15 Mpa/Bulk density 1600-1800 Kg/m3 and pull out bond strength -> 0.5 Mpa. Note: The rate quoted by contractor shall include cleaning of surface , application as per instruction and scafolding upto 20mtr height all as per specified and directed.
14M and L for rendering 10mm thick ready made plaster on internal walls by adding potable water by weight of material as mentioned by manufacture. Ready - Mix plaster shall complies with IS 1661 - 1972, IS-2250-1981, IS 2402-1963 and shall confirm the compressive strength @ 28 days - 10-15Mpa/Bulk density 1600-1800 Kg/m3 and pull out bond strength - > 0.5Mpa.
15M and L for rendering 5mm thick ready mix self curing plaster on ceiling by adding potable water by weight of material as mentioned by manufacture. Ready - Mix plaster shall complies with IS 1661 - 1972, IS-2250-1981, IS 2402-1963 and shall confirm the compressive strength @ 28 days - 10-15Mpa/Bulk densityh 166-1800 Kg/m3 and ppuill out bond strength - > 0.5Mpa.
16M&L for Cleaning & applying rust remover (Sika rustoff100)) in two coats over rusted reinforcement surface and providing anti corrosive coating with two component epoxy based zinc rich primer/Rust passivation Inhibitor coat at the rate of 6-8 sq. mtr/ltr not less than 50 microns dft with Sika friazinc R or equivalent to reinforcement surface as per manufacturer’s instructions including all scaffolding, machinery, tools tackles and clearing of debris complete all as specified and directed by Engineer-in-charge.
17Demolition of cement concrete reinforced in ground floors and pavings n.exc 15 cm thick (below or above ground level) all as directed by Engineer-in-charge.
18M & L for reinforced cement concrete (M-25) Fins, fascias, louvres, parapets, and railings exc. 60cm in height, newels, balustrade, and the lik complete all as specified and directed by Engineer-in-charge.
19M & L for Formwork to flat faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to battercomlpete.
20M&L Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips including dismantling of existing bar complete all as specified and directed by Engineer-in-charge.Note : Additional Reinforcement: In the case of the shear reinforcement also, if the diameter of the rebars are reduced, provide 8mm dia stirrups in the form of 2 \\"U\\" shaped bars. Tie them properly so that it has a tight contact with the main bars.
21S&F chicken mesh wire netting 25 gauge supplied and fixed on wall ceiling with nails complete all as specified and as directed.
22S & F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected tocommon rafters and running rails and guides for sliding doors; fixed with angle cleats or otherconnecting plates including dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified
23S&F Pre painted Galvalume aluminium zinc coating GI based corrugated steel sheet/ semi corrugated 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall fixed with self tapping screws as including dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings
24M& L plain cement concrete 1:2:4 type by using 20mm graded stone agregate as in flooring with water proofing compound @ 2% dosage (1kgs) in 50kg cement including demolition of cement concrete un -reinforced in ground floors and pavings n.exc 15cm thickness complete all as specified.
25Supply of SBR based waterproofing compound @ 2% dosage by weight of cement (1kgs) of 50kg cement used to be mixed in cement concrete as water proofing and hardening.
26M & L For applying Pitch Free PU based Liquid applied single component elastomeric seamless, water and vapor proof membrane system Nitoproof 600PF for concrete @ 2.50 kg/m2 (2 coats). Typical applications will include roofs, podiums, balconies, floor slabs, suspended floors, patios, bathrooms, inspection pits, swimming pools, bridge decks, Conforming Tensile Strength (2N/mm2 ) (ASTM D412) / Tear resistance (15 kN/m) (ASTM D624-00 and Crack bridging (ASTM C836 / ASTM C1305 modified)2mm. After 72 hours of curing, flood test can be carried out to a minimum depth of 50mm of water for 24 hours. Drains shall be plugged and barriers placed to contain the water. Note : All above operations to be done in presence of auth applicator in order all as specified and directed.
27M&L for Non - skid colored ceramic tiles 7 to 8 mm thick (square / rectangular) area of each tile exceeding 0.11 sqm but not exc 0.18 sqm, in floors etc. by fixing with 6-8mm thick bedding of TYPE2 tile adhesive Make: Ultratech TileFixo range and pointed in epoxy grouing only for laying floor finishes complete all as specified. Note : Work will be in patches or in bulk all as specified and directedMake: Equivalent of Ultratech/Fosroc/Sika/Choksey, etc
28M&L for Coloured Glazed ceramic tiles in vertical surface 450X 300X 7mm thick set, by fixing with 6-8mm thick bedding of TYPE2 tile adhesive Make: Ultratech TileFixo range set and pointed in epoxy grouting. incl dismantling of wall tiling including backing coat if any, removing rubbish off the premises all as specified and directed Make: Equivalent of Ultratech/Fosroc/Sika/Choksey, etc
29M & L for Machine cut kota stone slab flooring 20-25mm thick over, laid over cement screed base , jointed and pointed with grey cement slurry mixed with pigment over 20mm thick cement mortar 1:6 screed bed to match the shade of the slab including rubbing and polishing including dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc. laid beded and pointed in any morter complete all as specified.complete all as specified and directed.
30M & L for Machine cut kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar over 10 mm thick cement plaster 1:3 jointed and pointed with grey cement slurry mxed with pigment to match the shade of the slab including rubbing and polishing including dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc. laid beded and pointed in any morter complete all as specified.complete, all as specified and directed.
31M & L for Mirror polishing on old marble/ granite/ Kota stone/ stone work where ever required to give high gloss finish complete.
32Demolition of plain cement concrete in ground floors and pavings n. exc 15 cm thickness (below or above ground level) Including removal of debries out side MoD land complete all specified and as directed
33M&L for 50mm thick PCC 1:3:6 type C2 (using 20mm graded agg) as in plinth protection incl finishing even & smooth without using extra cement complete all as specified and directed.
34M&L for 25mm thick PCC (1:2:4) type B-1 (using 20mm graded stone aggregates) as in flooring complete all as specified and directed by Engineer-in-charge.
35M&L for cement concrete 1:4:8, type D-2, using 40 mm graded stone aggregate, as in Sub base for floor all as specified .
36M&L for Precast cement concrete 1:3:6 type C1 (Using 20 mm graded granite stone aggregate) block masonry with solid blocks, exceeding 10 cm in width and setting in cement mortar 1:6 including demolition of brickwork or stone/ boulder/block masonry and built in cement mortar including all quoins arches, pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles and removal unserviceable materials, debris and rubbish to a distance not exceeding 100m complete all as specified & directed by Engineer-in-charge.complete all as specified & directed by Engineer-in-charge.
37M & L 20mm thick Granite (Jodhpur Red) work (table rubbed and polished) for wall lining / partition b/w urinals and for counter wash basin 10mm thick in cement mortar (1:3) and pointing / fixing with epoxy grouting only using marble dust w ith admixture of pigment to match with shade of granite including cleaning of damaged granite and fix with epoxy grouting only.including dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc. laid beded and pointed in any morter complete all as specified.
38Supply & Fixing in repair 20mm of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified and directed by Engr-in-charge.
39Supply & Fixing in repair 25mm of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified and directed by Engr-in-charge.
40Supply & Fixing in repair 25mm of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified and directed by Engr-in-charge.
41M&L for Cutting chases, of girth not exceeding 10 cm for concealed water tubing or concealed conduit wiring, etc. in stone / brick masonry wall built in cement mortar and making good, disturbed surface in Cement mortar 1:3 complete.
42Taking down eaves gutters and rainwater pipes (any type or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories all as specified and directed
43S & F PVC (SWR) 110 mm bore pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors all as specified and directed.
44S & F PVC (SWR) 110 mm bore pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed by Engineer-in-charge.
45S & F inepair PVC (SWR) 75 mm bore pipes single socketed in any length with rubber ring joints fixed to walls completed all as specified and as directed by Engineer - in charge.
46S & F inepair PVC (SWR) 75 mm bore pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors all as specified and directed
47SWR(PVC) 110 mm Drainage Pipe Supply for Pipe Supporting Clamping - Single Pipe of PVC dia 110 mm (4\\") down take pipe fixing done with Clamping System consists of Profile Bracket + Continuous Slotted C Channel + U Bolt Rubber Sleeve mounted System running vertically with wall distance 100 mm (4\\"): Pipe Support Clamping made of : 1. Profile Bracket having Wall Distance 100 mm (4\\") made of Low Carbon Hot Roll Gauge Corrected Oil Pickled and Drawn (HROP D) Steel (IS 1079); material size 32 mm x 3 mm with ribs and notch are Hot Dip Galvanzied + Zn Al Flake coated having Salt Spray Test (Test method - ASTM B-117-2019) result 2000 hrs with SS304 Hex Flange Bolt with Serration 5/16 x 3/4 (A/F 13mm) as per DIN 6921and SS304 Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration as per DIN 6923. 2. Continuous Slotted \\"C\\" Channel with ribs to be used of size 250 mm (10\\") made of Low Carbon Hot Roll Gauge Corrected Oil Pickled and Drawn (HROP D) Steel (IS 1079) are Hot Dip Galvanzied + Zn Al Flake coated with material 48mm x 3mm. 3. U bolt Rubber Sleeve mounted are made of low carbon mild steel with Rod diameter 7 mm approx.; Zn Al Flake coated with noise absorbing semi transparent ribbed silicon rubber sleeve; with Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration set as per DIN 6923 - Zn Al Flake coated. Hotdip Galvanizing: As per IS 2629 (1985) - 610 grams/m2 (> 85 microns). Material Grade : IS 1079 used as per MTC confirms to EN 10204 3.1. Material Qty. for one unit : 1. Profile Bracket Wall distance 100 mm (4\\") - 2 Nos. 2. Continuous Slotted C Channel of Size 250 mm (10\\") - 1 No.; 3. U Bolt Rubber sleeve mounted for 110 mm (4\\") PVC Pipe Dia. - 1 No.; and 4. Fixing Nail Zn coated of thickness 6.5 mm and length 63 mm (2 1/2\\") - 4 nos. Fixing Details: Pipe Support Clamping Unit to be fixed at every metre distance in the duct as specified in Chief Engineer Jodhpur Zone Technical Drawing (TD) of Factory Made Pipe Supporting System . REF DRG NO. CEJZ/TD/102. Make: Shaivi or equivalent as approved by GE. Note:- Pipe, elbow, T,vent cowl,Y and all above related accessories rate are include in this item.
48SWR(PVC) 75 mm Drainage Pipe Supply for Pipe Supporting Clamping - Single Pipe of PVC dia 75 mm (4\\") down take pipe fixing done with Clamping System consists of Profile Bracket + Continuous Slotted C Channel + U Bolt Rubber Sleeve mounted System running vertically with wall distance 100 mm (4\\"): Pipe Support Clamping made of : 1. Profile Bracket having Wall Distance 100 mm (4\\") made of Low Carbon Hot Roll Gauge Corrected Oil Pickled and Drawn (HROP D) Steel (IS 1079); material size 32 mm x 3 mm with ribs and notch are Hot Dip Galvanzied + Zn Al Flake coated having Salt Spray Test (Test method - ASTM B-117-2019) result 2000 hrs with SS304 Hex Flange Bolt with Serration 5/16 x 3/4 (A/F 13mm) as per DIN 6921and SS304 Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration as per DIN 6923. 2. Continuous Slotted \\"C\\" Channel with ribs to be used of size 250 mm (10\\") made of Low Carbon Hot Roll Gauge Corrected Oil Pickled and Drawn (HROP D) Steel (IS 1079) are Hot Dip Galvanzied + Zn Al Flake coated with material 48mm x 3mm. 3. U bolt Rubber Sleeve mounted are made of low carbon mild steel with Rod diameter 7 mm approx.; Zn Al Flake coated with noise absorbing semi transparent ribbed silicon rubber sleeve; with Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration set as per DIN 6923 - Zn Al Flake coated. Hotdip Galvanizing: As per IS 2629 (1985) - 610 grams/m2 (> 85 microns). Material Grade : IS 1079 used as per MTC confirms to EN 10204 3.1. Material Qty. for one unit : 1. Profile Bracket Wall distance 100 mm (4\\") - 2 Nos. 2. Continuous Slotted C Channel of Size 250 mm (10\\") - 1 No.; 3. U Bolt Rubber sleeve mounted for 110 mm (4\\") PVC Pipe Dia. - 1 No.; and 4. Fixing Nail Zn coated of thickness 6.5 mm and length 63 mm (2 1/2\\") - 4 nos. Fixing Details: Pipe Support Clamping Unit to be fixed at every metre distance in the duct as specified in Chief Engineer Jodhpur Zone Technical Drawing (TD) of Factory Made Pipe Supporting System . REF DRG NO. CEJZ/TD/102. Make: Shaivi or equivalent as approved by GE. Note:- Pipe, elbow, T,vent cowl,Y and all above related accessories rate are include in this item.
49S & F in repair 75mm size PVC (SWR) vent cowl complete all as specifeed and directed.
50S & F in repair 100mm size PVC (SWR) vent cowl complete all as specifeed and directed.
51S & F in epair PVC (SWR) 110mm bends any radius all as specified and directed
52S & F inrepair PVC (SWR) 75mm bends any radius all as specified and directed.
53S &F in repair 110mm bore PVC (SWR) Single 'Y'branch piece, double (double Y) equal or unequal complete all as specified and as directed.
54S & F in epair PVC (SWR) multi floor trap 75 mm with grating including jointing with solvent cement all as specified and directed
55S & F in repair Flushing cistern of PVC 10 ltr. cap. with single flushing system, valveless syphonic action type, , low level, white/ivory/off white with inlet, ball valve, float and including brackets and connection to pipe etc. and incl all necessary accessories like rag bolts/gel gasket etc as recommended by manufacturer for fixing, packing and taking down existing of any description/size complete in all respect all as specified.
56S&F in repairs 15 mm size Central Hole Basin Mixer without Popup Waste System with 450mm Long Braided Hoses screwed for iron pipe complete all as specified & directed.Make: (Jaquar) Cat No.CON-167KNB or equivalent make mentioned in Appendix 'B'
57S&F in repair 15 mm size bib tap long body with wall flange , chromium plated, screwed for iron pipe or for brass ferrule complete all as directed.Make: Cat No : CON-107KN (JAQUAR) or equivalent make mentioned in Appendix 'B'
58S&F in repair 15 mm size Basin inlet connection (Angular stop cock) with wall flange, chromium plated all as specified and directed. Make : Cat No (JAQUAR) CON-059KN or equivalent make mentioned in Appendix 'B'
59S&F in repair 15 mm concealed stop valve with Exposed Part Kit of Concealed StopCock with Fitting Sleeve, Operating Lever & Adjustable Wall Flange (Compatible with ALD-083FT & ALD-089FT), chromoum plated, with regular body of suitable for 15mm bore pipe line complete all as directed.Make : Cat No (JAQUAR) Cat No.CON-083FTK or equivalent make mentioned in Appendix 'B'
60S & F in repair for 125mm size Brass chromium plated shower rose with or without swivel joints, any size completed all as specified and an as directed.
61S&F in repair 20mm dia brass chromium plated towel rail completed all as specified and as directed.
62S & F in repair SS Soap dish, embedded in the wall completed all as specified all as specified.
63S & F in repair for PVC connections 15mm size with PTMT nuts of length 600mm complete all as specified and directed.
64S&F in repair 800mmx800mm bevelled edge mirror of selected quality 5mm glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers, complete all as specified and as directed.
65S & F in repair Vitreous china squatting pan of pattern Orissa Pattern of size 580x 440 mm white with 110mm bore PVC ‘P’ or ‘S’ trap , front or back inlet but excluding flushing cistern and flush pipe including placing in position in floor and embedded in cushion of PCC type E2 ( 1:5:10, using 40 mm graded stone aggregates), and finishing the top surfaces to match with the existing flooring as in repairs.
66S&F in repair European type water closet including CI P/S trap as directed including connection to drain (or out going pipe) and to flushing pipe, antisyphonagee pipe,etc.,with flush pipe PVC 32mm dia and incl. plastic seat cover as recommended by manufacturer closed pattern with flat bottom etc; and incl all necessary accessories like rag bolts/gel gasket etc as recommended by manufacturer for fixing, packing and including supply and fix of PVC long arm P/S trap so that joint is avoided inside the building as well as in wall and outlet straight away come out of wall in all floors G.F.and taking down existing of any description/size complete in all respect all as specified.
67S & F in repair Vitreous china premium/1st quality wash basin (under counter), white, size 550x400 mm including S&F all accessories as recommended by manufacturer complete fixed in position in all respect as per manufacturer's instructions and all as specified including all Waste fittings, brass,chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed, Note : The items for counter will be measured and paid separately.
68Supply and fixing in repairs PVC Flexible waste pipe 32/40 mm dia having length 900mm with socket for steel sink/WHB/ urinal upto floor level complete all as specified and directed.
69S & F in repair Vitreous china premium/1st quality urinal pedestal type of white colour, of size 355x340x535mm incl providing and fixing plugs/brackets, bedding urinal against wall in CM 1:2, securing urinals to plugs with and incl S&F of all accessories for fixing as recommended by manufacturer like 60mm long brass secrews/fasteners/rag bolts etc, pointing urinal back in white cement; connecting for discharge pipe incl necessary packing, union complete all as specified.Make: Jaquar . Cat part No: URS-WHT-13261or equivalent make mentioned in Appendix 'B'
70S & F 1000 litres capacity white tripple layer, rotational molded, polythene water storage tank, ISI Marked (Cylindrical vertical with closed top),colour white , hoisted and fixed on roof in position, including all fitting such as connection pieces with GI tank nipple for inlet and outlet, washout and overflow etc and including 25 mm size Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe complete incl dismantling water tanks and removing to store complete all as specified and as directed by Engineer-in-Charge.
71M&L for Cleaning of HDPE service water tank of capacity exc 250 litre but not exc 500 litre and the connected circulating pipes at any position by removing sludge, mud, moss, moulds, efflorescent salts, oil spots etc or any other foreign material from the bottom, cover and internal surfaces by scraping using wire brush, draining out the water from the tank and washing internally with water & bleaching powder (0.10 Kg of bleaching powder will be mix in 1 litre water) and again draining out the water from the tank and writing the date of cleaning with white synthetic enamel paint on black background with synthetic enamel paint including disconnecting existing tanks (Exc 250 Ltrs but not exc 500 Ltrs capacity PVC water tank), setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position.complete all as directed by Engineer-in-charge.
72S & F in repairs 20 mm bore Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. Min weight 15mm-142gms/ 2 0 m m - 2 1 0 g m s . / 25mm-455gms/ 40mm - 690 gms) complete.
73S & F in repairs PVC water storage tank cover for 1000/500ltr capacity complete all as specified.
74Taking down chowkats or frames exc 1.5 sqm but n.exc 4sqm each with shutters (without taking off shutters from the frame), complete all as specified and as directed.
75Taking down chowkhats or frames (without taking off shutters from the frame) n. exc 1.5 Sqm incl cutting holes and making good reqd shape for hold fast block for new frame complete all as specified.
76Taking down shutters of any description exc 1sqm but not exc 2.00 sqm each complete all as specified and as directed.
77Resecuring or easing & adjusting without taking down the shutter of any description exc 1 Sam and n.exc 2 Sqm in same opening complete all as specified and directed.
78S & F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). ® Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extrapayment on this account shall be made.
79S & F 35mm thick glazed and skelton shutters of 2nd class hard wood (factory made) open rebated and divided to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass etc size of members of shutter as specified in SSR-91 Pt-I section 8 clause 8.20 (a) kiln seasoned and chemically pressure treated all as specifeid including stainless steel 304 grade wire cloth ( 0.36mm nominal dia of wire and average width of aperture 1.40 mm ) complete all as specified and directed by Engineer-in-charge and including supply and fixing following items :-(a) Stainless Steel (304 Grade) Finished Butt Hinges 125mm - 3 nos per leaf(b) Stainless Steel (304 Grade) Finished Tower Bolt 200mm long - 2 nos per leaf(c) Stainless Steel (304 Grade) Finished Handles 200 mm - 2 nos per leaf(d) Stainless Steel (304 Grade) Finished Sliding Door Bolt/Aldrop 16x3000mm - 1 nos per leaf(e) Stainless Steel (304 Grade) Finished Floor Door Stooper - 1 nos per leaf
80S & F 30mm thick Factory made single extruded WPC (Wood PolymerComposite) solid plain flush door shutter comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunkS.S screws, all as per direction of Engineer-In-Charge and incl supply and fixing following items:-(a) Stainless Steel (304 Grade) Finished Butt Hinges 125mm - 3 Nos per leaf(b) Stainless Steel (304 Grade) Finished Tower Bolt 200mm long - 2 Nos per leaf(c) Stainless Steel (304 Grade) Finished Handles 200 mm - 2 Nos per leaf
81S & F for Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified.
82S & F for Steel ventilator with top hung shutter including hinges, steel peg stay, complete
83S & F 300mm, mild steel, ordinary rat tail rod pattern springs including roller and roller plate, bearing ISI mark complete including necessary welding work all as specified and as directed.
84Supply and fixing Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staple complete .
85M & L for preparation of new or previously untreated steel surfaces including two coat of synthetic enamel (ordinary tint) paint over priming with red oxide,zinc of any description, over 10cm in width or girth, not otherwise described
86M & L for preparation of new wooden surfaces of any description exc 10 cm width or girth and applying two coats of synthetic enamel paint, first quality, over a coat of zinc chromium oxide primer complete all as specified and as directed.
87S & F in repairs 100mm size MS butt hinges medium weight cold rolled all as specified and as directed by Engineer-In-Charge.(ISI Mark, Make: Crown or Equivalent)
88S & F in repairs 200mm long stainless steel barrel tower bolt all as specified and as directed by Engineer-In-Charge.(ISI Mark, Make: Crown or Equivalent)
89S & F in repairs 150mm long stainless steel handle all as specified and as directed by Engineer-In-Charge.(ISI Mark, Make: Crown or Equivalent)
90S & F in repairs 250mm x 16mm dia stainless steel sliding door bolt with hasp and staple (bolt type) and fixing clips of steel cast or extruded section (ISI Mark, Make: Crown or Equivalent)
91S & F in repairs 140 mm over all length of cover plate of floor door stopper, bearing ISI mark, of stainless steel body and tongue, anodised with hard drawn steel spring, complete all as specified and as directed.
92Supply and fixing in repairs Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete .
93S & F 3mm thick sheet glass ordinary quality & glazing with oil putty or fitted with wooden/steel beads in squares n.exc. 0.50 sqm in each pane including hacking out old broken glass with puty or fixed with wooden bends complete all as specified and directed.
94S&F 3 mm thick frosted on one side sheet glass ordinary quality & glazing with oil putty or fitted with beads in squares n.exc. 0.50 sqm in each pane including hacking out old broken glass with puty or fixed with wooden bends complete all as specified and directed.
95S & F Inrepair stainless tubing of 25mm dia chromium plated min 1.00mm wall thickness as in curton rod and including 02 Nos stainless steel brackets/finials fancy type , stops fixed with SS screws etc complete all as specified and directed by the Engineer-in-Charge. Note : For the purpose of measurement and payment running length of curtain rod and only shall be considered.
96Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premise complete all as specified and directed by Engineer-in-charge.
97Material & Labour for ceramic out door tiles 300mmx300mmx10mm thick digital design set, jointed and pointed in neat cement slurry as in floors with grey cement over & including over screed bed or bedding layer of mortar 15 mm thick Cement Mortar 1:6 . Note : Work will be in patches or in bulk
98M&L for rubber moulded supplying and laying 80mm thick factory made chamfered edge cement concrete paver block of M-25 grade with approved colour, design & pattern as in footpath,parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratorymethod using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand,compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed.Note: colour and design as approved by GE
99M& L Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening whereverrequired complete
100Material & Labour for 75 mm thick sand stone slabs as in drain covers,cover stone templates, etc. n exc. 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in lime mortar 1:2 or cement mortar 1:4 i ncluding demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortarcomplete all as specified and as directed.
101Demolition of cement concrete of any description and in any position not otherwise specifically provided for an removing the debries outside from MoD land complete all as specified and as directed by Enginneer in charge
102S&F RCC pipe class NP-2 ISI marked laid to slope in trenches jointed and tested complete with collars for 150 mm dia pipe complete all as specified and directed by Engineer - in - Charge.
103Earth work in excavation by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m,including getting out the excavated oridanary rock and disposal of surplus excavated soil as directed, within a lead of 50 m. complete all as specified.
104Returning filling in including spreading leveling and well ramming in layers n.exc 25 cm thick complete all as specified and as directed by Enginneer in charge.
105Removing excavated material to a distance exc 50m but n.exc 100 m and depositing where directed at a level n.exc 1.50m from starting point complete all as specified and as directed by Enginneer in charge.
106M & L Cement concrete 1:3:6, type C-2 (using 40mm graded crushed stone agg) as in bed to drain pipe including packing under and haunching against the sides of pipes after they are laid and tested for 150 mm Bore dia including demolition of concrete of any description and breaking of pipe complete all as specified and directed by Engineer in charge
107Taking down carefully surface aluminium point wiring with PVC casing-caping (light, fan, socket, bell or power) including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc and making good disturbed surfaces complete.
108M&L for point wiring using approved colour coding as per IS (Red , Black and Green for single phase circuits),with multistranded copper conductor 1.5 sq mm nominal cross-sectional area , single core, PVC insulated and unsheathed FRLSH cable 1100 Volts grade, ISI-694 marked with valid CML No.in and inciuding medium grade, Concealed PVC conduit and accessories on wall/roof/floor etc, ISI marked with mild steel/pressed steel sunken box thickness as per IS standard (with earth dolly) duly painted with two coats of anti corrosive paint/aluminium paint over a coat of red oxide primer internally. and two coats of black bituminous paint over a coat of red oxide primer externally,covered with 3 mm thick plastic laminated sheet cover for fixing of switches, socket and fan regulators etc, inciuding PVC insulated multistranded copper conductor 1.5 sq mm nominal cross sectional area single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed by Engineer-in-charge for One light or fan point, controlled by one, one way switch 5 Amps.
109(a) One light point controlled by one switch.
110(b) One Ceiling /Exhaust fan point controlled by one switch.
111(c) One socket outlet 5 amp controlled by one switch on the same board with other switches.
112All as per Item No 108 here-in-before but for one socket outlet of 05 Amps fixed on independent board
113All as per Item No 108 here-in-before but for one socket outlet of 15 Amps fixed on independent board with 4.0 Sq mm multistranded copper conductor wire FRLS PVC insulated and 4.0 Sq mm multistranded copper conductor wire FRLS PVC insulated as earth wire complete all as specified.
114S/F in repair modular switch one way 6A, 1 module .
115S/F in repair modular socket 6A-2/3 pin combined 2 module.
116S/F in repair modular switch socket combined 6A/16A , 6 pin, 2 module
117S&F in repair hum free electronic step fan regulator 120 - 280 volts of 100 watt capacity (socket type) including connecting up complete.
118S/F in repair Ceiling rose, three terminals PVC/polycorbonate, isolated body.
119S/F in repair vertical DBs TPN 6 way 415 V double door powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 54 - IK 09 with metal door, recess mounted, having insulated 200 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required,suitable for TP/FP MCCB as incomer with 01X MCCB 160A,16 KA, and with provision of SP/TP MCB's of required size as outgoing.
120S & F in repair for MCB DB TPN 4 way double door IP 54 complete prewired including Bus Bar etc suitable for operation on 240 volt 50 Hz AC supply including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed .Make: Legrand/Havells/Indoasian or equilent HSN code : 8537
121Supply and fixing in repair MCB TPN 32 Amps to 100 Amps, 240 Volts,10 KA rapturing capacity 'C' curve.complete all as specified & directed. Make :Legrand/Havells/Indoasian
122S & F in repair for MCB DB SPN 8 way double door IP 54 complete prewired including Bus Bar etc suitable for operation on 240 volt 50 Hz AC supply including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed .Make: Legrand/Havells/Indoasian
123S&F as in repair MCCB 4 Pole, 415V, Adjustable type, 100 to 125 Amps with breaking capacity 16 KA complete all as specified and as directed.
124Supply and fixing in repair MCB's single pole and neutral 40 to 63 Amps, 240 Volts,10 KA rapturing capacity 'C' curve.complete all as specified & directed.
125Supply and fixing in repair MCB's single pole 06 Amps to 32 Amps, 240 Volts,10 KA rapturing capacity 'C' curve.complete all as specified & directed. Make :Legrand/Havells/Indoasian
126Ditto as above item but capacity of 40 Amp
127S&F in repair 3 phase submain wiring with approved colour code/as per IS (R,Y,B,black & green for three phase)concealed conduit circuit with two single core PVC insulated cable with multistranded copper conductor of nominal cross sectional area of 6.00 Sqmm (FRLSH) in Concealed pvc conduit including one run of PVC insulated multistranded copper conductor nominal cross sectinal area of 6.00 Sqmm (FRLSH) of continous earth wire green in colour complete including taking/down all as specified and directed by Engr-In-Charge.(Note :- Four runsof 6.00 Sqmm cable & one run of 6.00 Sqmm cable shall be paid as one unit length)
128S&F in repair submain wiring with approved colour code/as per IS (Red,black & green for single phase)concealed conduit circuit with two single core PVC insulated cable with multistranded copper conductor of nominal cross sectional area of 6.00 Sqmm (FRLS) in Concealed pvc conduit including one run of PVC insulated multistranded copper conductor nominal cross sectinal area of 6.00 Sqmm (FRLS) of continous earth wire green in colour complete including taking/down all as specified and directed by Engr-In-Charge.(Note :- Two runsof 6.00 Sqmm cable & one run of 6.00 Sqmm cable shall be paid as one unit length)
129S&F in repair building security light fitting LED 15 Watt IP 66 IK 07 pressure dia cast aluminium housing with high efficient LED as lihjting souce and PC cover having TOP opening sepreate drive compartment etc and connecting as specified and directed .Havells or Crompton/Philips equivalent as approved.
130S& F in repair of repair bracket of GI pipe medium grade of 40mm dia ,1.2 meter in length clamps made of FI 40 mm x 6mm incl nuts ,bolts & washers,painting complete as specified .
131S&F in repair LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
132S & F in repair of LED tube light fitting 10 watt tube LED Neutral white in colour, 600 mm in length wall mounted LED batten,extruded aluminium heat shink provided for efficient heat dissipation & integrated electronic driver,optic diffused type ENDURA LINER NEO including all electric connection with whilte flexible cord 1.50 Sqmm 3 core as required complete all as specified and directed.Make :- Crompton/philips/Havells. cat no-LUMILINEBS10WLED865SPCWH
133S & F in repair for LED down lightrecess mounted/Surface mounted/POP mounted or as per site requirement, square/Round type worm white / Neutral white or 2700 K- 3000 K as per user requirement 18 watts with efficiency of 100 lumens per watt, in worm white/ neutral white as per site requirement sleek design aluminium housing polycarbonate diffuser white finish operating voltage from ceiling rose to fitting complete all as specified and as directed. CAT NO-CDR-206-18-57--SL NWH , MAKE - CROMPTON
134Taking down ceiling fan of any sweep sealing cable end dismanting blade and removing fan and blade complete all as specified and directed
135M& L for painting of ceiling fan complete in situ with synthetic enamel paint by spraying including filling cavity with filler one coat after cleaning all dust etc compete all as specified and directed .
136Fixing of ceiling fan ,including making serviceable and noise free in all respect and connecting up including provn of cable from ceiling rose or connector to fan complete all as specified and as directed .(Note :- Rate Quated by Contractor shall be inclusive for replacing all unsv item like quater pin ,nut bolt with check nut ,rubber real etc.)
137M & L in repair of rewinding of fan of any size with supper enameled copper wire of existing gauge including varnishing and drying complete reassembling & testing complete of 1200/1400 mm sweep complete all as specified and as directed.
138S&F in repair Fan condenser, 2.5 Mfd, 240 volts for ceiling/exhaust fan including PVC clamp Make: Epcos, Bajaj, Havells, Crompton
139S&F in repair of Ceiling fan downrod suitable size upto 03 fit with GI Hook as per requirement of site of any size
140Supply & Fix in repair including taking down for ball bearing suitable for ceiling fan 1200/1400mm sweep complete all as specified and as directed. Make : SKF/NBC/TATA
141Supply and fix in repair exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers including taking down of previous u/s exhaust fan and painting/sticking of SM /MES No by paint/radium all as specified and as directed. Old unsv exhust fan deposited to Mes Store yard
142M & L in repair bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe 40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate, charcoal & salt up to ground level connected to 4.00 mm dia GI wire as earthing lead up to 7.5 mtr by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 15 mm dia light grade pipe for earth lead protection connected to electrical equipment and earthing test point , earth dolly and earth chamber as shown in elect plate No 2 of SSR Pt-I including all necessary earth work, excavation, earth chamber with PCC 1:3:6, Type C1 and RCC chamber cover of PCC 1:2:4 with handle and 20 mm dia GI watering pipe with funnel and wire mesh etc and testing on complete all as specified and directed Engr-in-Charge. Note : Testing of earthing of any type, after disconnecting from test point and other loops by using ISI marked digital/Analog earth tester of reputed make and test result shall be entered in a Earth Testing register and put up to the Engr-in-Charge after testing complete all as specified and directed. Test result for item No. 7 and all earthing in schedule to be provided to Engr-in-Charge before completion of work. Earth tester to be provided by the contractor himself.
143M&L in repair for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to DBs or any other indicated situation for loop earthing with 4.00 mm dia GI wire size complete all as specified and directed Engg-in-Charge.
144M&L in repair for GI Tubing light grade 15 mm dia.for cable protection complete all as specified and directed Engg-in-Charge.
145Supply ,laying in repair and testing cable XLPE insulated ,screened ,PVC bedded ,galvanized steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium condutor of size 70 sq mm 3.5 core all as specified and directed .
146Supply ,laying in reapir and testing cable XLPE insulated ,screened ,PVC bedded ,galvanized steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium condutor of size 35 sq mm 3.5 core all as specified and directed .
147Excavation in soft /Disintegrated rock not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide for laying of cable and getting out complete all as specified and diected at site .
148Returnig filling in including spreading ,leveling ,watering and well ramming excavated soft/disintegrated rock in layers all as specified and directed at site .
149Removing excavated materials (hard/disingated rock) to a distance not exceeding 50 mtr and deposting where directed at alevel not exceeding 1.5 m above the starting point all as specified and directed .
150M & L in repair HDPE DWC pipe ISI Marked fixed on walls, ceilings or in floors, trenches etc. for cable protection of 80 mm dia all as specified and directed.
151S&F repair ,50 mm bore GI tubing \\"light garde \\"in treches on pole for protection of cables complete all as specified & directed by Enginner-in Charge .
152S&F repair ,80 mm bore GI tubing \\"light garde \\"in treches on pole for protection of cables complete all as specified & directed by Enginner-in Charge .
153M&L for road cutting and making good with PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) complete all as directed by Enger -in- charge.
154Taking out of old panel & Supply instal testing and commissioning of CPRI approved factory make LT panel board outdoor type pedelstal mounted dust proof, weather proof, vermin proof front side double door hinge type with locking arrangement rear side single door hinge type with locking arangement, sheet steel cubical type with slanting roof made out of 3.0mm thick CRCA sheet with powder coated finished suitable length and size. High conductivity 3 phase and neutral Aluminium bus bar of 300 Amps capacity duly mounted on pre cast insulators including earth work excavation, PCC foundation necessary coping work, nuts and bolts and connecting electrically with suitable copper cable lug, cable glands etc complete all as specified and directed to accomodate the following items.Incoming:- (a) MCCB 200 amps 4 pole 16 KA - 1 Nos.(b) 3 phase LED ammeter & Voltmeter - 01 Set (d) LED type indication lamp for RYB.Outgoing:(a) MCCB 63 amps 4 pole 16 KA - 4 Nos.
155M & L in repair of bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe 40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate, charcoal & salt up to ground level connected to 25X3 mm GI strip as earthing lead up to 7.5 mtr by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 40mm dia light grade pipe for earth lead protection connected to electrical equipment and earthing test point , earth dolly and earth chamber as shown in elect plate No 2 of SSR Pt-I including all necessary earth work, excavation, earth chamber with PCC 1:3:6, Type C1 and RCC chamber cover of PCC 1:2:4 with handle and 20 mm dia GI watering pipe with funnel and wire mesh etc and testing on complete all as specified and directed Engg-in-Charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56783384
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 70.78 Lakhs
LAST DATE 28-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Name Of Work : Special Repair To Bldg No P-1300 And P-1301 (Sm Barrack And Toilet Block) At Field Regt Under Ge (A) Jaisalmer At Mil Station Jaisalmer
Basic Detail
Tender No 84460/C/E8
Bidding Type Tender
Location
City Jaisalmer
State Rajasthan
Key Dates
Publish Date 31 Jul 2026
Submission Date 28 Aug 2026
Open Date 29 Aug 2026
Finance
Tender Value 70.78 Lakhs
Tender Fee 1000
EMD 1.32 Lakhs
Exemption Available
Document List
BOQ_876181.xls
cb8cebe9-e1ac-4629-a164-e5a5464d61ef.html
TENDER1.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 31, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 28, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Aug 29, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_876181.xls

html

cb8cebe9-e1ac-4629-a164-e5a5464d61ef.html

pdf

TENDER1.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender