Tender For Special Repairs To Building No P-118 (Kill House) At installation Dronacharya Under Ge Fort Kochi
Tender Overview
Project Description
Tender for Special Repairs To Building No P-118 (Kill House) At installation Dronacharya Under Ge Fort Kochi
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 21-Aug-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 28-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling structural steel work, including doors, gates, etc complete all as specified and as directed. |
| 2 | Cutting holes in brick walls exc half brick thick but not exc one brick walls built in cement mortar for inserting hold fasts, fixing lugs and similar articles and making good the dismantled portion in cement mortar 1:3 or in cement concrete 1:2:4 type B-1 complete all as specified and as directed. |
| 3 | Demolition of cement concrete (un reinforced) in ground floors and pavings not exc 15 cm thickness below or above ground level, complete all as specified and as directed. |
| 4 | Material and labour for plain cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation, filling and mass concrete, complete all as specified and as directed. |
| 5 | Material and labour for 40 mm thick plain cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in floors finished even and smooth using extra cement, complete all as specified and as directed. |
| 6 | Material and labour for 2 mm thick homogenous PVC tiles/sheets, plain coloured, marbled mosaic or mottled finish, laid with approved rubber-based adhesive in floors, complete all as specified and as directed. |
| 7 | Supply and fix 1.6 mm thick mild steel plain black sheet in wall cladding, steel gates and similar work, cut to size, holes punched etc, fixing to frame work with riveted or welded seams including bending/ turning up, mitred angles etc as required, complete all as specified and as directed. |
| 8 | Supply and fix rolled sections as in main or cross beams, running rails and guides etc fixed with cleats or other plates of Fe-410-W (grade E-250) quality A, complete all as specified and as directed. |
| 9 | `Ditto- all are as per item No 8 above but fixing only |
| 10 | Supply and fix mild steel framed work as in door, gates of angle and other sections with gusset plates, rails, braces etc for covering doors etc, to be prepared for hanging or sliding including hooks and hinges and hanging (exclusive of steel sheeting) complete all as specified and as directed. |
| 11 | Supply and fix plain or chequered plates square cut or notched (ordinary or counter sunk), forming holes with riveted, bolted or welded attachments, complete all as specified and as directed. |
| 12 | Fixing only plain or chequered plates (obtained from dismantling) square cut or notched (ordinary or counter sunk), forming holes with riveted, bolted or welded attachments, complete all as specified and as directed. |
| 13 | Supply and fix stairs / ladder (framed) including stringers, treads, landing, balusters, hand rail etc including cleats, brackets complete all as specified and as directed. |
| 14 | Taking down chowkats or frames not exc 1.5 Sqm each with shutters (without taking of shutters from the frame complete all as specified and as directed. |
| 15 | Powder coated aluminium frame & sections for sliding windows, ventilators, one or more rebates including jointing cleat for fixing, handles, locking arrangements etc complete all as specified and as directed. Note: glass panes shall be measured and paid separately. |
| 16 | Material and labour for 5mm thick sheet Toughened glass exceeding 0.50 sqm in each pane fixed to aluminium windows/ventilators or in partitions complete all as specified and as directed. (Note: Rate quoted shall be deemed to inclusive of rubber beading). |
| 17 | Hacking out old broken glass (any thickness, size, quality or description) from metal frames, glazed with putty or fixed with beads, complete all as specified and as directed. |
| 18 | Supply and fix 5mm thick sheet Toughened glass and glazing with oil putty in square exc 0.5 Sqm in each pane, complete all as specified and as directed. |
| 19 | Taking down cement plaster on brick or stone walls, etc, including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and as directed. |
| 20 | Material and labour for rendering 15 mm thick in two coats (10 mm thick in cement mortar 1:4 and 5 mm thick in cement mortar 1:4 mixed with water proofing compound) on other than fair faces of brick work or concrete surfaces finished even and smooth without using extra cement, complete all as specified and as directed. Note: - water proofing compound shall be measured and paid separately |
| 21 | Material and labour for plastering in cement mortar 1:6, 10 mm thick on walls finished even and smooth without using extra cement, complete all as specified and as directed. |
| 22 | Supply only liquid water proofing admixture of Fosroc chemicals/ Pidiliteor equivalent complete all as specified and as directed. |
| 23 | Material and labour for two coats of Antifungal paint (Apex Ultima Protec of Asian paint or equivalent as approved) over a coat of Exterior primer (Professional pack of Asian Paintsor equivalent ) over a coat of external wall care putty not.exc 2mm thick on new or old prepared plastered external surfaces and including scaffoldings and cradles including hoisting and lowering as required with bracing support complete all as specified and as directed. |
| 24 | Material and labour for preparation of new plastered surfaces of wall and applying two coats of oil bound distemper (Oil emulsion) over a coat of primer complete all as specified and as directed. |
| 25 | Material and labour for preparation of old surfaces of ceiling and applying two coats of oil bound distemper (Oil emulsion) over a coat of primer complete all as specified and as directed. |
| 26 | Material and labour for applying oil based bitumen primer @ 0.25 Kg/Sqm, providing and laying 4 mm thick APP modified water proofing membrane weighing not less than 160 g/Sqm having softening point not less than 140°C, longitudinal tensile strength not less than 650 N/Sqm, tearing strength of 180 N by torch application including min 10 cm side over lap and 15 cm end lap, applying a coat of blown grade hot bitumen 90/15 over membrane @ 1.2 Kg/Sqm and applying bituminous aluminium paint @ 100 gm/Sqm complete all as specified and as directed. |
| 27 | Supply and fix tubes 50 mm bore medium grade galvanised with all fitting and fixed complete to roof as railing/guard bars, complete all as specified and as directed. |
| 28 | Supply and fix tubes 25 mm bore medium grade galvanised with all fitting and fixed complete to roof as railing/guard bars, complete all as specified and as directed. |
| 29 | Material and labour for preparation of new steel surfaces over 10cm width or girth and applying two coats of VX-polymer based anti-corrosive paint over a coat of anti-corrosive primer complete all as specified and as directed. |
| 30 | Material and labour for preparation of Old steel surfaces over 10cm width or girth and applying two coats of VX-polymer based anti-corrosive paint over a coat of anti-corrosive primer including complete removal of old paints, rusted portion, dust etc. complete all as specified and as directed. |
| 31 | Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets, complete all as specified and as directed. |
| 32 | Material and labour for 5mm thick plain embossed PVC false ceiling boards of size 595mm x 595mm of density 600 Kg/Cum plain colour decorative type fixed with and including pre powder coated white GI snap grid frame work (Make Everest Armstrong etc) of size main runner 24x38x.32mm cross tee 24x28x.3mm and wall angle 19x22x.4mm to be placed at desired level fixed with 4mm dia GI suspender wire @ 1.2 m centre to centre with steel rafter/purlins complete all as specified and directed. |
| 33 | Welding in repairs not exc 2.5cm in length of metal plate n exe 6mm thickness, complete all as specified and as directed. |
| 34 | Welding in repairs not exc 2.5cm in length of metal plate thickness exc 6mm but not exc 9mm, complete all as specified and as directed. |
| 35 | Welding in repairs exc 2.5cm in length but not exc 5cm of metal plate of thickness not exc 6mm, complete all as specified and as directed. |
| 36 | Welding in repairs exc 2.5cm in length but not exc 5cm of metal plate of thickness exc 6mm not exc 9mm, complete all as specified and as directed. |
| 37 | Running welding in repairs not exc 6mm, complete all as specified and as directed. |
| 38 | Taking down copper / aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc and making good the disturbed surfaces of walls, floors, etc. complete all as specified and as directed. |
| 39 | Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface complete all as specified and as directed. |
| 40 | Supply and instal Hi wall mounted air-cooled star rated split type air conditioner, electric driven ,230 V, single phase indoor unit, outdoor unit complete with cordless remote-control unit and within built air ioniser, plasma filter, for better indoor air quality with minimum 5-star rating and BEE 5.0 of capacity 2.0TR, complete all as specified and as directed. Make :- Blue Star, LG, Carrier, Diakin |
| 41 | Supply and fixing single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB,240 volt, 20 Amps complete all as specified and as directed. |
| 42 | Voltage stabilizer of automatic operation, three phase naturally oil cooled indoor, type and designed, for input variation between 170 V to 250 V without voltage stabilized at 230 V accuracy +/- 2.5 % and speed of correction, 8 volt per second and of capacity 5.0 KVA, complete all as specified and as directed. Make :- V-Guard, Servo, Blue bird, Microtek |
| 43 | Taking down carefully copper/aluminium Sub main wiring of any size from surface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and as directed. |
| 44 | Material and labour for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sqmm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in wall/ceiling etc, heavy duty ISI marked, with GI sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with inner frame suitable for modular switches, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly including cutting wall/PCC, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and as directed for the following :- |
| 45 | One light point controlled by one, one way switch 5 Amps |
| 46 | One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board. |
| 47 | One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board. |
| 48 | Description all as per item No 44 here in before but using 2.5 sq mm single core copper conductor cable of multistranded FRLS PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket combination point including necessary running of 2.5 sq mm copper conductor FRLS PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly, complete all as specified and as directed. |
| 49 | Supply and fix Modular switch 06 Amp, single pole, one way, 230 Volt complete all as specified and as directed. |
| 50 | Supply and fix Modular switch 16 Amp, single pole, one way, 230 Volt complete all as specified and as directed. |
| 51 | Supply and fix Modular socket outlet 2 in 1, 3 pin, 06 Amp flush type, 230 volt, complete all as specified and as directed. |
| 52 | Supply and fix modular socket outlet multipurpose 2 in 1, 3 pin, 06 Amp and 16 Amp flush type, 230 volt, complete all as specified and as directed. |
| 53 | Supply and fix for Ceiling rose, surface Bakelite with 3 terminals, ISI marked for batten fitting complete all as specified and as directed. |
| 54 | Supply and fix in replacement of surface mounted LED tube light fitting four feet long, 20 Watt with IP 20 protection comprises of aluminium extruded channel, extruded aluminium body, integrated electronic driver, etc and all accessories pre-wired including connecting up complete all as specified and as directed. |
| 55 | Material and labour for Sub main wiring with approved colour coding as per IS with four single core PVC insulated FRLS cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non-metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessories ISI marked heavy duty of suitable size including concealed in wall etc two runs of PVC insulated with 6 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note:- Four runs of 6 sqmm cable, two runs of 6 sqmm cable and one run of PVC conduit will be measured as one unit |
| 56 | Material and labour for Sub main wiring with approved colour coding as per IS with four single core PVC insulated FRLS cable with stranded copper conductor of size 4 Sq mm nominal area and drawing into suitable size of PVC non-metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessories ISI marked heavy duty of suitable size including concealed in wall etc two runs of PVC insulated with 4 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note:- Four runs of 4 sqmm cable, two runs of 4 sqmm cable and one run of PVC conduit will be measured as one unit |
| 57 | Supply and fix in repairs of sheet metal enclosure distribution board, triple pole and neutral, vertical type, AC, 415 volt, 04 way with 200 Amp rated copper bus bar and double door complete all as specified & directed and comprising of the following : (a) MCCB, 125 Amps, 04 pole, AC, 415 Volts of 25 KA breaking capacity complete 01 No ( incoming )(b) MCB, SP, AC, 240 volts of up to 40 Amps,10 KA, 'C' Curve capacity complete - 12 Nos, all as specified and as directed. (outgoing) |
| 58 | Supply and fix sheet metal enclosure MCB DB SPN 12-way Vertical type with 200 Amps rated bus bar 230 volts double door with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonry etc. and making good of disturbed surface to match with existing colour of wall complete all as specified and as directed. |
| 59 | Supply and fix MCB SPN 40 to 63 Amp, 240 volts of 10 KA rupturing capacity, C-curve type as outgoing complete with connection testing and commissioning complete all as specified and as directed. |
| 60 | Supply and fix MCB SP 6 to 32 Amp, 240 volts of 10 KA rupturing capacity, C-curve type as outgoing complete with connection testing and commissioning complete all as specified and as directed. |
| 61 | Material and labour for earthing complete with galvanised steel earth plate electrode 60cmx60cmx6.3mm thick, buried directly in Set ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel Gl protection pipe 15mm bore light grade all as shown in electrical plate No 3 on serial page No 497 of SSR part 2009 and connected to main switch board/ Main DB's including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, Gl pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 75mm centre to centre both way with 12mm dia lifting handle and pit/ chamber in PCC 1:3:6 type C1, Angle iron 40mmx40mmx3mm frame for pit cover including testing on completion including taking down old unserviceable earthing complete all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 4 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender