Tender For Supply, Installation, Commissioning & Testing Of Latest Online Water Quality Analyzers, Rotameters, Flow Meters And Centralized Monitoring System For Dm Plant At Unit No. 5, 210 Mw Atps Mppgcl Chachai.
Tender Overview
Project Description
Tender for Supply, Installation, Commissioning & Testing Of Latest Online Water Quality Analyzers, Rotameters, Flow Meters And Centralized Monitoring System For Dm Plant At Unit No. 5, 210 Mw Atps Mppgcl Chachai. , Analyzers , Dual Channel Conductivity Analyser Complete Set With All Accessories For Differential Cation Conductivity. Calibration Range: 0-50 Μs/Cm Input Power Supply : 230 V Ac, 50 Hz Analog Output : 4-20 Ma Modbus Communication Protocol : Rs-485 , Single Channel Conductivity Analyser Complete Set With All Accessories. Calibration Range: 0-50 Μs/Cm Input Power Supply : 230 V Ac, 50 Hz Analog Output : 4-20 Ma Modbus Communication Protocol : Rs-485 , Dual Channel Analyzer (Conductivity + Ph ) Complete Set With All Accessories. Conductivity Calibration Range: 0-10 Μs/Cm Ph Calibration Range: 0-14 Ph Input Power Supply : 230 V Ac, 50 Hz Analog Output : 4-20 Ma Modbus Communication Protocol : Rs-485 , Dual Channel Analyzer (Conductivity + Ph ) Complete Set With All Accessories. Conductivity Calibration Range: 0-1 Μs/Cm Ph Calibration Range: 0-14 Ph Input Power Supply : 230 V Ac, 50 Hz Analog Output : 4-20 Ma Modbuscommunication Protocol : Rs-485 , Single Channel Ph Analyzer Ph Calibration Range: 0-14 Ph Input Power Supply : 230 V Ac, 50 Hz Analog Output : 4-20 Ma Modbuscommunication Protocol : Rs-485 , Silica Analyzer , Silica Analyzer Alongwith Complete Set Of All Accessories, Reagents Etc. Input Power Supply : 230 V Ac, 50 Hz Analog Output : 4-20 Ma Modbus Communication Protocol : Rs-485 Channels Location: 1. Sba- A Outlet 2. Mb- A Outlet 3. Sba- B Outlet 4. Mb- B Outlet , Rotameters/ Varible Area Flowmeters (For Dm Plant) , Bypass Rotameter Accuracy : ± 2% Of Full Flow, Moc Of Orifice Plate: Ss316, Moc Of Float : Ss316, Moc Of Float Retainer : Ss316, Moc Of Body : Ms Powder Coating, Moc Of Packing : Ptfe, Moc Of Measuring Tube : Borosilicate Toughened Glass, Wetted Parts: Ss316 Type Of Tapping : Corner Tapping (Carrier Rings), Range Of Rotameter : 16.0-80.0 M3/Hr, Output Pressure : 4-5 Kg/Cm2, Output Flow : 41-42 M3/Hr, Max. Flow : 46-47 M3/Hr, Line Size : 100 Nb, Pipe Id : 97.2-100 Mm, Pipe Od : 114 Mm, Tube Size : Pg-3 (For Normal Pressure Application), B- Ratio : 0.6-0.7 , Online Rotameters , Accuracy : ± 2% Of Full Flow, Moc Of Float : Ss316, Moc Of Float Retainer : Ss 316, Moc Of Body : Ms Powder Coating, Moc Of Packing : Ptfe, Moc Of Measuring Tube : Borosilicate Toughened Glass, Line Size: 50Nb, Wetted Parts: Ss316 Type Of Connection : Flange Type, Housing Protection Class : Ip-65 , Orientation : Inlet Connection - Bottom, Outlet Connection : Top, Range Of Rotameter : 0.6 - 6 M3/Hr, Output Pressure : 4.5 Kg/Cm2, Output Flow : 3.34-4.2 M3/Hr, Meter Size : 50 Nb, Flange Size : 40, Pipe Id : 33.9 Mm, Pipe Od : 48 Mm , Accuracy : ± 2% Of Full Flow, Moc Of Float : Ss316, Moc Of Float Retainer : Ss 316, Moc Of Body : Ms Powder Coating, Moc Of Packing : Ptfe, Moc Of Measuring Tube : Borosilicate Toughened Glass, Line Size: 50Nb Type Of Connection : Flange Type, Housing Protection Class : Ip-65 , Orientation : Inlet Connection - Bottom, Outlet Connection : Top, Range Of Rotameter : 1.6 - 16 M3/Hr, Output Pressure : 4-4.5 Kg/Cm2, Output Flow : 9.35-10.5 M3/Hr, Meter Size : 80 Nb, Flange Size : 50, Pipe Id : 45 Mm, Pipe Od : 60 Mm , Flowmeters With Totalizer , Type: Vortex Flow Meter Pipe Line Size : 100 Nb Pipe Line Material : Msrl Pipe Line Od : 114 Mm, Id : 97.2 Mm Flow : 0 - 75 M3/Hr Process Liquid : Dm Water , Type: Vortex Flow Meter Pipe Line Size : 80 Nb Pipe Line Material : Msrl Pipe Line ; Od : 90 Mm, Id : 80 Mm Flow : 0 - 75 M3/Hr Process Liquid : Dm Water , Type: Electromagnetic Flow Meter Pipe Line Size : 200 Nb Pipe Line Material : Erw Ms Pipe Line : Od =218 Mm ; Id : 200Mm Flow : 310 M3/Hr Discharge Head : 25 M Process Liquid : Clarified Water , Type: Electromagnetic Flow Meter Pipe Line Size : 150 Nb. Pipe Line Material : Erw Ms Pipe Line : Od =168 Mm ; Id : 150Mm Flow : 120 M3/Hr Discharge Head : 30 M Process Liquid : Clarified Water , Centralized Monitoring System Of Dm Plant Comprises Of Industrial Grade Pc, Screen/Monitor, Connectivity System Etc. , Ups System 2 X 10Kva (Hot-Standby Configuration) With Single Battery Bank, Alkaline Battery Bank Is To Be Supplied For At Least 10 Hour Power Backup. Input Power Supply : 230 V Ac Single Phase. Output Power Supply : 230 V Ac Single Phase. Ups Properties: 1) Master & Slave And Auto Changeover On Fault 2) If Both Ups Failed, Auto Switchover On Auxiliary Power Supply , Power Cable For All Instruments Three Core 2.5 Sq.Mm Multi Strand Copper 230Vac Armoured , Control Cable For All Instruments Communication Cable Rs-485 , Two Core, Four Pair , 01 Sq.Mm Armoured , Installation & Commissioning Of Whole System As Per Scope Of Work , annual maintenance contract Charges For 03 Years (Minimum 02 Days Per Visit Only) , For 1St Year (Total 3 Visit Per Year) , For 2Nd Year (Total 3 Visit Per Year) , For 3Rd Year (Total 3 Visit Per Year)
BOQ
| Sl. No. | Item Description |
| 1 | Analyzers |
| 2 | Dual Channel Conductivity Analyser complete set with all accessories for Differential Cation Conductivity.Calibration Range: 0-50 μS/cm Input Power Supply : 230 V AC, 50 HzAnalog Output : 4-20 mAMODBUS Communication Protocol : RS-485 |
| 3 | Single Channel Conductivity Analyser complete set with all accessories.Calibration Range: 0-50 μS/cmInput Power Supply : 230 V AC, 50 HzAnalog Output : 4-20 mAMODBUS Communication Protocol : RS-485 |
| 4 | Dual Channel Analyzer (Conductivity + pH ) complete set with all accessories.Conductivity calibration range: 0-10 μS/cmpH calibration range: 0-14 pHInput Power Supply : 230 V AC, 50 HzAnalog Output : 4-20 mAMODBUS Communication Protocol : RS-485 |
| 5 | Dual Channel Analyzer (Conductivity + pH ) complete set with all accessories.Conductivity Calibration Range: 0-1 μS/cmpH calibration range: 0-14 pHInput Power Supply : 230 V AC, 50 HzAnalog Output : 4-20 mAMODBUSCommunication Protocol : RS-485 |
| 6 | Single Channel pH AnalyzerpH calibration range: 0-14 pHInput Power Supply : 230 V AC, 50 HzAnalog Output : 4-20 mAMODBUSCommunication Protocol : RS-485 |
| 7 | Silica Analyzer |
| 8 | Silica Analyzer alongwith complete set of all accessories, reagents etc. Input Power Supply : 230 V AC, 50 HzAnalog Output : 4-20 mAMODBUS Communication Protocol : RS-485 Channels Location:1. SBA- A Outlet 2. MB- A Outlet3. SBA- B Outlet4. MB- B Outlet |
| 9 | Rotameters/ Varible area flowmeters (For DM Plant) |
| 10 | Bypass Rotameter Accuracy : ± 2% of Full Flow, MOC Of Orifice Plate: SS316, MOC Of Float : SS316, MOC Of Float Retainer : SS316, MOC Of Body : MS Powder Coating, MOC Of Packing : PTFE, MOC Of Measuring Tube : Borosilicate Toughened Glass, Wetted Parts: SS316Type Of Tapping : Corner Tapping (Carrier Rings), Range of Rotameter : 16.0-80.0 m3/Hr, Output Pressure : 4-5 kg/cm2, Output Flow : 41-42 m3/Hr, Max. Flow : 46-47 m3/Hr, Line Size : 100 NB, Pipe ID : 97.2-100 mm, Pipe OD : 114 mm, Tube Size : PG-3 (For Normal Pressure Application), B- Ratio : 0.6-0.7 |
| 11 | Online Rotameters |
| 12 | Accuracy : ± 2% of Full Flow, MOC Of Float : SS316, MOC Of Float Retainer : SS 316, MOC Of Body : MS Powder Coating, MOC Of Packing : PTFE, MOC Of Measuring Tube : Borosilicate Toughened Glass, Line Size: 50NB, Wetted Parts: SS316 Type Of Connection : Flange Type, Housing Protection Class : IP-65 , Orientation : Inlet Connection – Bottom, Outlet Connection : Top, Range of Rotameter : 0.6 - 6 m3/Hr, Output Pressure : 4.5 kg/cm2, Output Flow : 3.34-4.2 m3/Hr, Meter Size : 50 NB, Flange Size : 40, Pipe ID : 33.9 mm, Pipe OD : 48 mm |
| 13 | Accuracy : ± 2% of Full Flow, MOC Of Float : SS316, MOC Of Float Retainer : SS 316, MOC Of Body : MS Powder Coating, MOC Of Packing : PTFE, MOC Of Measuring Tube : Borosilicate Toughened Glass, Line Size: 50NB Type Of Connection : Flange Type, Housing Protection Class : IP-65 , Orientation : Inlet Connection – Bottom, Outlet Connection : Top, Range of Rotameter : 1.6 - 16 m3/Hr, Output Pressure : 4-4.5 kg/cm2, Output Flow : 9.35-10.5 m3/Hr, Meter Size : 80 NB, Flange Size : 50, Pipe ID : 45 mm, Pipe OD : 60 mm |
| 14 | Flowmeters With Totalizer |
| 15 | Type: Vortex Flow MeterPipe Line Size : 100 NBPipe Line Material : MSRLPipe Line OD : 114 mm, ID : 97.2 mmFlow : 0 - 75 m3/hrProcess Liquid : DM water |
| 16 | Type: Vortex Flow MeterPipe Line Size : 80 NBPipe Line Material : MSRLPipe Line ; OD : 90 mm, ID : 80 mmFlow : 0 - 75 m3/hrProcess Liquid : DM water |
| 17 | Type: Electromagnetic Flow MeterPipe Line Size : 200 NBPipe Line Material : ERW MS Pipe Line : OD =218 mm ; ID : 200mmFlow : 310 m3/hrDischarge Head : 25 mProcess Liquid : Clarified water |
| 18 | Type: Electromagnetic Flow MeterPipe Line Size : 150 NB.Pipe Line Material : ERW MSPipe Line : OD =168 mm ; ID : 150mmFlow : 120 m3/hrDischarge Head : 30 mProcess Liquid : Clarified water |
| 19 | Centralized Monitoring System Of DM Plant comprises of Industrial Grade PC, Screen/Monitor, Connectivity System etc. |
| 20 | UPS System 2 X 10KVA (Hot-Standby Configuration) with Single Battery Bank, Alkaline battery bank is to be supplied for at least 10 hour power backup.Input Power Supply : 230 V AC Single Phase.Output Power Supply : 230 V AC Single Phase.UPS Properties: 1) Master & Slave and auto changeover on fault 2) If both UPS failed, auto switchover on auxiliary power supply |
| 21 | Power Cable for all instrumentsThree core 2.5 sq.mm Multi Strand copper 230Vac Armoured |
| 22 | Control Cable for all instruments Communication cable RS-485 , Two core, four pair , 01 sq.mm Armoured |
| 23 | Installation & Commissioning of whole system as per scope of work |
| 24 | AMC Charges for 03 years (minimum 02 days per visit only) |
| 25 | For 1st year (Total 3 visit per year) |
| 26 | For 2nd year (Total 3 visit per year) |
| 27 | For 3rd year (Total 3 visit per year) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender