Drinking Water Supply and Sanitation Local Bodies Closing in 1 days TDR #56781657

Tender For Construction Of Additional Building At Government Hospital Coonoor In Coonoor Municipality

Issued by Local Bodies · Nilgiris, Tamil Nadu
Tender Value
3.50 Crore
Estimated cost
Bid Submission
17 Aug 2026
1 days left
EMD
3.50 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Nilgiris → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of Additional Building At Government Hospital Coonoor In Coonoor Municipality

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 31-Jul-2026 Change the Bid opening date Date 17-Aug-2026

BOQ

Name of Work:- CONSTRUCTION OF ADDITIONAL BUILDING AT GOVERNMENT HOSPITAL COONOOR IN COONOOR MUNICIPALITY
Sl. No. Item Description
1Earth work excavation for foundation by Mechanical means for Isolated & Combined Footing etc in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 100 mts and clearing and levelling including dressing of sides and raming of bottoms etc., complete complying with standard specification and as directed by the departmental officers.- Upto 2.40m Footing Depth.
2First Depth (0m to 2.4m)
3Earth work excavation for foundation by Mechanical means for Isolated & Combined Footing etc in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 100 mts and clearing and levelling including dressing of sides and raming of bottoms etc., complete complying with standard specification and as directed by the departmental officers.- Upto 2.40m Footing Depth.
4Second Depth (2.4m to 3.3m)
5Earth work open excavation by manual means in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the excavated earth with a lead of 10 mts. within the compound in places shown by the departmental officers and clearing and levelling the site, etc., complete complying with standard specification and as direct-ed by the departmental officers.
6Foundation & Basement Excavation
7Supply and filling in foundation and basement with Gravel in layers of not more than 15cm.thick well rammed watered and compacted with surface vibrator, watered and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
8Cement Concrete 1:5:10 (One Cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and including curing etc. complete complying with standard specification and as directed by the departmental officers -Mixing by mechanical means
9Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 2.10 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton and as directed by the departmental Officers(Payment for centering shall be given after the concrete is laid)
10Basement R.C.C. Wall
11Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, Sill slabs etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid with silver oak joists of size 10cm x 5cm & 7.5cm x 5cm as support runner , vertical stiffener, side support and Top Horizontal stiffener spaced at about 60cm to 90cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid).
12Footing Centering
13Supplying and erecting centering for plane surfaces such as RCC Floor/Roof Beam, Lintels, Cantilever Beams, Bed Blocks etc.. with necessary supports and strutting upto 3.60m height in all floors with all cross bracings using MS Sheets made of 10 gauge thick welded with MS angle of Size 25mm x 25mm x 3mm for boarding laid over Steel adjustable Span of Size 2m x 2m(expandable upto 3.60m) and Silver Oak Joists of Size 10 x 5 cm spaced at 50cm to 60cm c/c and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick) Spaced at not more than 50 to 60cm c/c , etc complete complying with standard specifications. Steel adjustable span and Steel Adjustable telescopic props shall be provided as directed by the departmental Officers. (Payment for centering shall be given after the concrete is laid).
14Roof Beam (0 to 3.6m)
15Supplying and erecting centering for plane surfaces such as RCC Floor/Roof beam, Lintels, Cantilever Beams, Bed Blocks etc.. with necessary supports and strutting above 3.60m upto 4.90m height in all floors with all cross bracings using MS Sheets made of 10 gauge thick welded with MS angle of Size 25mm x 25mm x 3mm for boarding laid over Steel adjustable Span of Size 2m x 2m (expandable upto 3.60m) and Silver Oak Joists of Size 10 x 5 cm spaced at 50cm to 60cm c/c and supported by Steel Adjustable Telescopic Props of Size 2.40 x 3.0m (expandable upto 4.90m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick) Spaced at not more than 50 to 60cm c/c and with Cross bracings provided at two levels at a spacing of 1.80m etc complete complying with standard specifications. Steel adjustable span and Steel Adjustable telescopic props shall be provided as directed by the departmental Officers. (Payment for centering shall be given after the concrete is laid).
16Roof Beam (3.6 to 4.9m)
17Supplying and erecting centering for plane surfaces such as RCC Floor Slab, Roof Slab, Loft, Landing Slabs, etc with necessary supports and strutting upto 3.60m height in all floors with all cross bracings using MS Sheets made of 10 gauge thick welded with MS angle of Size 25mm x 25mm x 3mm for boarding laid over steel adjustable span of size 2m x 2m (expandable upto 3.60m) and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick) , etc complete complying with standard specifications. Steel adjustable span and Steel Adjustable telescopic props shall be provided as directed by the departmental Officers. (Payment for centering shall be given after the concrete is laid).
18Roof Slab (0 to 3.6m)
19Supplying and erecting centering for plane surfaces such as RCC Floor Slab, Roof Slab, Loft, Landing Slabs, etc with necessary supports and strutting above 3.60m upto 4.90m height in all floors with all cross bracings using MS Sheets made of 10 gauge thick welded with MS angle of Size 25mm x 25mm x 3mm for boarding laid over steel adjustable span of size 2m x 2m (expandable upto 3.60m) and supported by Steel Adjustable Telescopic Props of Size 2.40m x 3.00m (expandable upto 4.90m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick) with Cross bracings provided at two levels at a spacing of 1.80m ,etc complete complying with standard specifications. Steel adjustable span and Steel Adjustable telescopic props shall be provided as directed by the departmental Officers (Payment for centering shall be given after the concrete is laid).
20Roof Slab (3.6 to 4.9m)
21Supplying and erecting steel centering including necessary supports For plane surfaces such as rectangular or square RCC columns etc. which require only nominal strutting using mild steel sheets made of 10 gauge thick welded with MS angle size 40mm x 40mm x 5 mm and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick).etc..complete in all floors complying with standard specifcation. Steel Adjustable telescopic props shall be rovided as directed by the departmental Officers. (Payment for centering shall be given after the concrete is laid).
22Rectangular Column Centering
23Providing and laying in position, Standardised Concrete Mix M-25 Grade by insitu machine mix concrete adopting weighing batch method in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 350 kglm3 and maximum water cement ratio of 0.50, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 Cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cu.m) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m’) 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials).
24Foundation and Basement
25Ground Floor
26First Floor
27Terrace Floor
28Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel reinforcement grills of all variety like HYSD/CTD/TMTand all grade like Fe 500, Fe550D, Fe 500 D etc., for all RCC works as per design given including cost of steel reinforcement and G.I. binding wire, wastage etc. complete complying with standard specification and as directed by the departmental officers.(Contractor has to make his own arrangements for the supply of steel reinforcement and binding wire)
29Foundation and Basement
30Ground Floor
31First Floor
32Terrace Floor
33Brick work in following Cement Mortar using best quality Burnt Clay Brick of size 9” x 4 3/8” x 2 3/4” with class designation of 7.5 conforming to IS 1077-1992 for foundation and basement including Cost of Mortar Plasticizer curing, etc.,complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally.other type of bond shall be done as directed by the Executive Engineer in charge.(Cement Mortar 1:5)
34Foundation and Basement Wall
35Ground Floor Wall
36First Floor Wall
37Brick partition walls of 11.50cm thickness using best quality Burnt Clay Brick of size 9” x 4 3/8” x 2 3/4” with class designation of 7.5 conforming to IS 1077-1992 in Cement Mortar 1:3 (One Cement and Three CS Sand) using hoop iron reinforcement if found necessary including Cost of Mortar Plasticizer, curing etc. complete complying with standard specification and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately)
38Ground Floor Wall
39First Floor Wall
40Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Plastering Sand) 10mm thick including mortar plasticizer at 200ml per 50Kg of cement used , hacking the surfaces and curing, etc., in all floors complying with standard specification and as directed by the departmental officers
41Plastering with Cement Mortar 1:5 (One cement and Five Plastering sand), 12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curing etc. complete complying with standard specification and as directed by the departmental officers.
42Wall Plastering
43Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no crushed stone sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers.
44Terrace Area
45Finishing the top of roof with one course of machine pressed tiles of following size of approved quality set in Cement Mortar 1:3 (One Cement and Three Crushed stone Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers (Size of 230x16x18mm)
46Terrace Area
47Supplying and fixing Mild Steel grills for windows, ventilators etc.,complete complying with standard specifications and as directed by the departmental officers.
48FRP Door Sutter with FRP Door Frames made out of FRP Sheets of 3mm thick of over all size 65mm x 50mm with rebate suitably reinforced using MS Angle / Flats, cost of holdfasts and Solid Core FRP Shutter Panel of 5mm thick and hollow core frames of 3m wall thickness for styles and rails etc., of sizes specified by Engineers
49ABS DOOR / EQUIVALENT - Specification: Providing of 35mm thick factory made pre-laminated ABS (Acrolynitrile Butadiene Styrene) Door Shutter moulded in different designs, consisting of all round frame made out of water proof solid foam PVC bar of size 20 x 32mm, reinforced by 32 x 32mm - 2 Nos., for vertical made out of LVL (Laminated Veneer Lumber), core material of 32mm thick high density craft paper honey comb board, sandwiched on both sides with pre-laminated ABS sheet thickness of 1.5mm. PVC edge banding of size 0.45mm on the vertical sides. Hardware made out of steel coated butterfly hinges - 3 Nos., for each shutter and ISI make SS round lock complete for finished item of work, complete complying with the standard specification. The door shutter and frame should be got approved from the Executive Engineer before use on work
50Providing UPVC (Un-Plasticized Polyvinyl Chloride) Door: Providing and fixing casement doors fabricated from un-plasticized polyvinyl chloride (uPVC) sections. Profiles: The profiles should be three chamber system which provides high insulation properties with outer frame 60mm x 55mm with an outer wall thickness of 2.4mm. The window unit should be designed with all corner joints mitred and fusion welded. Windows should be steel reinforced with 25 x 24 x 25mm steel reinforcement with a thickness of 1mm to have dimensional stability. The sash should be of 60 x 102mm. The mullion should be of 60 x 74mm. The profiles should have co-extruded seals. Hardware: All the hardware like friction stays, handles should be screwed with self tapping screws. The handles, locks should be designed so that they cannot be released from outside. Glazing: The window system should be glazed with 5mm plain float glass / 6mm bison lam Installation: The profiles should be cut to length and welded 45 degrees. The window should be designed such that the water drainage does not pass through the reinforcement chamber. The window system should be fixed directly to the plastered brick wall using self expanding nylon plug and driving ms electroplated screws into plug
51Manufacturing, supplying and fixing of Teakwood ornamental Entrance door of size 1.20x2.10m with the following specification. The outer frame of ornamental Entrance Door of size 150x100mm Teak wood scantling. The door consists of openable area 1.06x2.03m with single leaf. The each openable shutter consists of Top Panel for 1.10m height and bottom vertical panel for a height of 1.00m. The Shutter bottom rail is of 200x50mm size and middle, top and side rails are of size 150x50mm with corner designed beading works. The shutter pannel is of 50mm thick T.W.planks with special curving works. The outer frames corners are designed border works single side for entrance outer frame and on both sides for middle frame. The cost includes all kinds of furniture fittings, such as special type heavy Brass Aldrop 300x20mm 1 No, special type heavy Brass tower bolt 300mm length 1 No and 200mm length 1 no, special type heavy brass hinges 200mm length 4Nos, special type door stopper 1 No, special type Ornamental door handles 2 Nos, Door bush and Door stopper etc., All the members are finshed with two coats of melamine polish outer the priming coat complete and as directed by the departmental engineers.
52Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 25GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with spag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown olour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the executive Engineer before use on work
53Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work
54Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete
55Paving the floor with best quality vitrified Tiles of following size and variety conforming IS 15622 with water absorbtion less than 0.08% of approved colour and shade laid over cement mortar bed of 20mm thick in cement mortar 1:3 (one cement and three crushed stone sand) with required Cement Slurry and Mortar Plasticizer in all floors and the top pointed with Water Resistant Tile Epoxy Grout etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
56Paving the floor with pre-polished concrete anti-skid tiles (Required shape and design) of 20mm thick of approved quality and colour laid in accordance with IS 1443 over a cement mortar bed of 20mm thick in Cement Mortar 1:3 (One Cement and Three crushed stone sand) with required Cement Slurry and Mortar Plasticizer and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
57Dadooing walls with following best approved quality, white / colour glazed tiles conforming to IS 15622 of following sizes in Cement Mortar 1:2 (One Cement and Two crushed stone sand),10 thick with Mortar Plasticizer and pointing the joints with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m. neatly in all floors, curing, etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use on works)
58Paving the floor with best approved quality fine polished Granite Stone Slabs of following size and Variety with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three crushed stone sand) with required Cement Slurry and Mortar Plasticizer and laid in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments etc., complete complying with standard speicification and as directed by the departmental officers.(The granite stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work)
59Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification and as directed by the departmental officers.
60Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
61Supplying and laying of Interlocking Paver Block Stone 63mm thick Over a base layer of crushed stone sandfilling incl. Cost of materials laying and Labour charges etc complete complying with the standard specification and as directed by the departmental officers.
62Supplying and fixing in position Manhole Cover (Heavy Duty) with Frame of size 60cm x 60cm with Cement Mortar 1:3 (One Cement, Three sand) including of best approved quality as per standard specification etc., complete compying with standard specifications.and as directed by the departmental officers.
63Supplying and fixing in position PVC mould CI Steps For Sump with Cement Mortar 1:3 (One Cement, Three sand) including of best approved quality as per standard specification etc., complete compying with standard specifications.and as directed by the departmental officers.
64MAIN PANEL: 'Supplying, erecting, connecting and commissioning of MAIN PANEL Fabrication of 14G CRCA Sheet and powder coated with necessary foundation channels, etc., The cost shall also including unloading, positioning,etc., The Board shall be incorporated with the following:- Surge Protection Device Three Phase Imax -50kA Current Transformer Current Transformer Ratio 300/5A, Burden 5VA, Cl.1.0 Metering Devices Multi function meter with CL 0.5 Indication lamps Electrical and Mechanical Interlocking System with supports. SMC and DMC Supports for Panel. 300A 415V, Aluminium busbar 3Phase,With Neutral Bar 50Hz. Incoming Feeders 250A 4P MCCB Spreader Terminal 250A Outgoing Feeders 63A TPN 10kA MCB 32A TPN 10kA MCB Spare 63A TPN 10kA MCB 32A TPN 10kA MCB Fabricated Panel shell with as per Electrical Standard Norms based on incomer and outgoing including supporting accessories spaces.Like Panel base frame etc.. With necessary aluminium busbars, interconnections, providing Combined Digital type Mulitifunction Meter with RS485, RYB phase indication lamps, surge protection devices with necessary CTs, control with MFM. MCB/MPCB/RCBOs etc. in each incoming feeder. Also providing ON,OFF & TRIP indication lamps in all incoming & outgoing feeders with control MCBs etc. The panel should be suitable for interlocking Electro and Mechaincal source-1 (I/C-1) to source-2 (I/C-2) while power failure happened at any one source with necessary power contactors and all required accessories. And also provide the selector switch for selecting auto / manual mode. All MCCBs, contactors & selector switch should have two ON, OFF & TRIP status of each through and all as per the specification and drawings.\\" BUS BAR RATING:One set: 300A 3phase + Neutral KA for 1 sec. AL. bus bars with colour coated heat shrinkable PVC sleeves with DMC/SMC bus bar supports and suitable earth bus. Voltage : 415 V Construction : Single Front with Top Cable Entry Dimension : To be assessed by Contractor. Location : Ground Floor Under Staircase
65Supply and fixing of 1 no.6A two module 3 pin socket , 1 no. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End
66Supply and fixing of 1 no.6/16A two module socket , 1 no. 16A one module switch on suitable module surface mounting Box (GI ) with module cover plate (plastic) on wall with connections. Higher End
67Supply and fixing of 25A Flush type Wall Socket 25A DP MCB complete set for AC Plug in flush with wall with earth connection (For AC Plug)
68Supply and fixing of 4 Feet LED 20W Fitting with LED 20W Tube Light (Higher End) complete with TW round blocks wall or ceiling with PVC unsheathed FRLS copper leads from terminals to the fitting.
69Supply and fixing of 60W LED 2x2 square type Recessed fitting with LED (Higher end) with Clean Room Fitting on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting.
70Supply and fixing of 6 Watts LED Round Type Surface mounted Down Light on Ceiling with PVC unsheathed copper leads from terminals to the fitting.
71Supply and fixing of 12 Watts LED Round Type Surface mounted Down Light on Ceiling with PVC unsheathed copper leads from terminals to the fitting.
72Supply and fixing of 15 Watts LED Round Type Surface mounted Down Light on Ceiling with PVC unsheathed copper leads from terminals to the fitting.
73Supply and fixing of 12 Watts LED Bulkhead Light on wall with PVC unsheathed copper leads from terminals to the fitting.
74Supply and fixing of 1200mm (48\\") sweep AC ceiling fan complete ( Higher end) with 2 module 100W fan step regulator (Higher end) with 1 metre down rod with fan clamp with side plates and cross arm of size 450mm (18\\")
75Supply and fixing of 300 mm (12\\") sweep light-duty AC exhaust fan, complete with all necessary mounting accessories, electrical connections, clamps, fasteners, and hardware, including provision of wall opening and making good the wall after installation. The work shall include cutting/opening in masonry, proper fixing of the fan, plastering/finishing to match existing surface, testing and commissioning, complete in all respects as per site requirements and directions of the engineer-in-charge.
76Supply and fixing of 7 segment 6 way TPN MCB sheet steel distribution board (Higher end) with metal / acrylic door cover flush type /surface type fitted with busbars and neutral links with single / three phase MCB outgoings and seperate 4 way provision for accomodating one No 4 pole incoming MCB / Isolator and another seperate 4 way provision for accomodating one No 4 pole ELCB / RCD (totally 8 ways in one segment) (3x 6 ways in Each segment) and seperate provision for MCB / Isolators ( totally 18 Nos) for sub incomers in 3 segments with lable holder and provison for taking up cable for size not less than 35 sq.mm. with the following on wall with Earth connection only.
77Supply and run of 3 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable heavy gauge MS conduit pipe concealed in wall and ceiling with continuous earth wire connection by 4 sq.mm copper wire and making good of the concealed portion with suitable colour
78Supply and Laying of 3.5C x 120 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good.
79Supply and Laying of 4C x 16 sq.mm. PVC armoured LTUG Cable Tray with suitable all necessary working and fixing.
80Supply and Laying of 4C x 10 sq.mm. PVC armoured LTUG Cable Tray with suitable all necessary working and fixing.
81Supply and fixing of brass cable gland for 3.5C x 120 sq.mm. PVC armoured LTUG cable with earth connection
82Supply and fixing of brass cable gland for 4C x 16 sq.mm. PVC armoured LTUG cable with earth connection
83Supply and fixing of brass cable gland for 4C x 10 sq.mm. PVC armoured LTUG cable with earth connection
84Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) ( 6 points / Coil) Lower End
85Wiring with 2x1.5sq.mm. PVC insulated single core unsheathed FRLS copper conductor cable of 1100V grade insuitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories inflush with wall with 150mmx100mmx75mm MSswitch box with 3mm thick hylum sheet cover for 5A 3pin non interlocking CS plug with continuous earth wire connection of 1.5sq.mm copper wire and making good of the concealed portion with suitable colour for concealed plugpoint
86Wiring with 2x4sq.mm. PVC insulated SC unsheathed FRLS copper conductor cable of 1100V grade insuitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories with 150mmx100mmx75mm MS switch box in flush with wall with 3mm thick hylum sheet for 15A 3pin noninterlocking flushtype CS plug with painting suitable colour with continuous earth wire connection of 4 sq.mm copper wire for open power plug point
87Supply and installation of 6 way Neutral Link 15Amps, complete with insulated base, tinned brass terminals, fixing screws, mounting accessories, and all necessary hardware, as required and as directed by the Engineer-in-Charge.
88Earthing as per the ISI specification with an earth electrode of 2.10 metre Class 'B' GI pipe of dia not less than 40mm with copper earth plate of size 125mm x 50mm x 6mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry
89Supply and run of 25 mm x 3mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection.
90Supply and Laying of Conduit Pipe 38mm (11/2\\") Heavy Gauge,including all necessary accessories such as bends, couplers, junction boxes, inspection boxes, saddles, spacers, solvent cement, screws, rawl plugs, etc., complete as required and as directed by the Engineer-in-Charge.
91Supply and Laying of Conduit Bend 38mm (11/2\\") 16 Heavy Gauge Bend, including all necessary fixing accessories, solvent cement, and jointing, complete as required and as directed by the Engineer-in-Charge.
92Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. (The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level - 110 mm dia Pipe - ( Cable entry)
93Supply and Fixing of Unarmoured 0.5mm Telephone Cable 4 pair, including laying in existing/new PVC conduit, casing-capping, cable tray or on wall/ceiling with approved saddles, complete with all fixing accessories, terminations, testing and commissioning, as directed by the Engineer-in-Charge.
94Supply and Fixing of 3 Trunk + 16 Analog Extensions. Expandable Up to 96 Analog Extension & 112 IP Port with configuration, interconnections, testing, commissioning and all necessary hardware, software and accessories, as required and as directed by the Engineer-in-Charge.
95Supply and Fixing of Basic Telephone without Caller ID all necessary accessories, testing and commissioning, as required and as directed by the Engineer-in-Charge.
96Supply, fixing, installation, and commissioning of a First Aid Box, complete with all necessary first aid medicines and supplies as per applicable safety standards. The scope includes proper mounting at designated locations, ensuring accessibility, stocking with standard items such as bandages, antiseptics, scissors, gloves, and other essential first aid materials, and ensuring readiness for emergency use in accordance with workplace safety regulations.
97Supply and fixing of Shock Treatment Chart, mounted in a durable glass frame, including proper positioning at designated locations, secure fixing to walls or panels, and ensuring clear visibility and accessibility for emergency reference, complete in all respects as per site requirements and applicable safety standards.
98Supply and fixing of Danger Board as required by the Electrical Authorities, including proper positioning at designated locations, secure mounting, clear visibility, and compliance with all applicable electrical safety standards and regulations, complete in all respects as per site requirements.
99Supply, installation, and fixing of 4.5 kg CO₂ fire extinguisher, conforming to TAC norms, including proper mounting at designated locations, secure brackets, clear labeling, and ensuring accessibility for emergency use. The work includes verification of certification, functional inspection, and compliance with applicable fire safety standards and site requirements, complete in all respects.
100Supply , Laying and Instalation, Dressing, Testing and Commissioning all CCTV Work including all Necessary acceeories such as Connectors, Conduits, Saddles and termination at both ends, Complete in all respects as per Requirements and Applicable Standards specifications.and as directed by the departmental officers.
101Unarmoued Lan & CCTV CABLE CAT-6
102PoE Switches for CCTV IP Camera Higer End 24 Port
1034MP IP Bullet / Dome Camera.
104Network Video Recorder for CCTV Higher End. -32 Channel - 2 SATA (2 Nos. Hard Disk)
105Lan Network Switches - Higher End , Fully Managed 10 / 100 / 1000 Layer-3 with10G Uplink - Higher End, 24 port
106Hard Disk For NVR - Higher End - 8TB
107Rack with Accessories - Higher end - 6U Rack
108POWER SUPPLY : 24VDC Power Supply with 5 amp rating, having LED indications for Power supply ON,battery Fail,Battery Charging,battery back up etc.
109Supply and Laying of Conduit pipe 38mm(11/2\\") Heavy Gauge
110Supplying and fixing in position first quality and approved variety of Gun metal Gate Valve / Wheel Valve with BIS make of the following dia including cost of shellac, thread balls, etc., complete complying with standard specifications (for both internal and external water supply arrangements). The valves to be used on work shall be got approved by the Executive Engineer before use on work.
111Gun metal Gate Valve (Heavy Duty )- 50 mm dia
112Gun metal Gate Valve (Heavy Duty )- 40 mm dia
113Gun metal Wheel valve (Heavy Duty ) -32 mm dia
114Gun metal Wheel valve (Heavy Duty ) -25 mm dia
115Supplying and fixing in position 15mm dia brass CP screw down tap / Pillar tap / Swan neck tap (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary. (Taps should be got approved by the Executive Engineer before use on the works)
116Swan Neck tap for sink
117Chromium plated pillar tap (Heavy type) -15 mm dia
118Supplying and fixing in position Indian make bevelled edge mirror of approved quality and brand PVC / Fibre Glass framed 5.5mm thick mirror of followingsize , Shelf type with hard board backing of approved colour fixed with brass screws, rawl plug, etc., complete complying with standard specification. (The mirror should be got approved by the Executive Engineer before use on woks) Size : 1000 x 780 mm.
119Supplying and fixing in position best quality and approved make Indian made white / colour glazed earthernware wash hand basin of size 550 x 400mm (with pedestal / without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia “B” class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works).
120Supplying and fixing in position white / colour glazed European Water Closet of best quality and approved make with 100 mm “P” or “S” trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn,teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings such as 15mm brass ball valve with polythene float with brass handle, union, coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings such as 15mm brass connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe including cost of 600mm length of 110mm dia PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition etc. complete complying with standard specifications. (The EWC and flushing tank wiht all accessories should be got approved by the Executive Enginer before use on works)
121Supply and fixing in position of best Indian make white / colour glazed earthernware lipped mouth flat back urinal of best quality and approved make of size 430mm x 260mm x 350mm with GI pipe, 32mm dia bell mouth PVC connection and waste pipe, 15mm dia GI pipe of required length, 15mm dia GM wheel valve, 15mm dia brass nipple 2 Nos., and fixing the urinals in position with necessary TW plugs, clamps, screws, etc., including dismantling masnory and re-doing the same to the original condition, etc., including painting the pipe with two coats of best quality approved synthetic enamel paint over one coat of red oxide primer and checked without any leakage etc. complete complying with standard specifications and as directed by the departmental officers. (The urinal should be got approved by the Executive Engineer before use on works.)
122Supplying and fixing in position CP shower rose with CP stop cock arrangement of size 15mm dia inlet and 100mm outlet to the pipe line with necessary cutting, threading and jointing using shellac etc., complete complying with standard specification and as directed by the departmental officers (The CP shower rose should be got approved by the Executive Engineer before use on works).
123Supplying and fixing best approved best quality Procelain CP soap tray of size 150 x 150mm including cost of teak wood plugs, brass screws, etc., complete complying with standard specifications. (The soap tray should be got approved by Executive Engineer before use on works).
124Supplying and fixing approved best quality brass CP towel rail 600mm long and 20mm dia with brackets of same materials including cost of teak wood plugs and CP screws, etc., complete complying with standard specifications. (The tower rail should be got approved by Executive Engineer before use on works).
125Supplying and fixing position CI Nahani Trap / Floor Trap of the following sizes with best stainless steel gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of crushed stone sandand five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three sand) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to the CI / PVC Specials, etc., complete complying with standard specification. (The Nahani Trap should be got approved by the Executive Engineer before use on works) Size of 100x75mm Pvc PVC Gratings
126Supplying and fixing in position 150 x 100mm “P” or “S” stoneware gully trap ‘A’ grade with CI double gratings of size 150 x 150mm and 230 x 230mm at bottom and top respectively with necessary earth work excavation laid over a bed of brick jelly cement concrete 1:3:6 (One cement, Three crushed stone sandand Six broken brick jelly) 150mm thick using 40mm size broken brick jelly including necessary brick work and plastering including dismantling masonry wherever necessary and re-doing the damaged portions to the original conditions using cement concrete 1:3:6 using 20mm stone jelly for fixing the gully trap and giving connections to stoneware sewer line etc., complete complying with standard specifications. [Earth work excavation, brick work, plastering shall be measured and paid separately]. The stoneware gully trap should be got approved by the Executive Engineer before use on works.
127Supplying and fixing in position best quality PVC soil / waste Specials of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. (The PVC Specials should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level
12875 mm dia PVC Pipe 6 kg / sq.cm
129110 mm dia PVC Pipe 6 kg / sq.cm
130160 mm dia PVC Pipe 6 kg / sq.cm
131Supplying, laying and jointing PVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing PVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications. The PVC pipes shall be got approved by Executive Engineer before use on works. - Internal water supply Above ground level.
13240 mm dia PVC Pipe 10 kg / sq.cm
133Supplying PVC Specials (with working pressure 10 kg. / sq.cm.) in water supply arrangements (both in internal and external water supply arrangements
13440 mm dia PVC Bend
135Supplying and fixing in position PVC specials of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the PVC soil stacks, dismantling the masonry or RCC works and re-doing the dismantled portion to original condition etc., complete complying with standard specifications. (The PVC specials should be got approved by the Executive Engineer before use on works).
13675 mm dia PVC Specials Elbow
137110 mm dia PVC Specials Elbow
13875 mm dia PVC Specials Door Elbow
139110 mm dia PVC Specials Door Elbow
140\\"Y\\" 75 mm
141\\"Y\\" 110 mm
142Supplying and fixing in position PVC cowls of following dia of best approved quality conforming to BIS, etc., complete complying with standard specifications. (The PVC cowl should be got approved by the Executive Engineer before use on works).
143Vent Cowl 110 mm
144Vent Cowl 75 mm
145Supplying, laying and jointing UPVC pipes of Class 6 (having working pressure of 12.50 kg/sq.cm) conforming to IS 4985- 2000 of approved quality and best variety of the following dia including cutting and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) in accordance with IS 7634-3 (2003) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications. The PVC pipes shall be got approved by Executive Engineer before use on works - Internal water supply above ground level.
14620 mm dia UPVC Pipes 12.50 kg/sq.cm
14725 mm dia UPVC Pipes 12.50 kg/sq.cm
14832 mm dia UPVC Pipes 12.50 kg/sq.cm
14940 mm dia UPVC Pipes 12.50 kg/sq.cm
15050 mm dia UPVC Pipes 12.50 kg/sq.cm
151Supplying UPVC Specials in water supply arrangements (both in internal and external water supply arrangements. Since the labour for cutting, pasting, sundries have already been included under pipe line item of works, no separate provision for fixing UPVC specials needs to be allowed
15250mm dia- Elbow
15340mm dia- Elbow
15432mm dia- Elbow
15525mm dia- Elbow
15620mm dia- Elbow
15750mm dia- Bend
15840mm dia- Bend
15932mm dia- Bend
16025mm dia- Bend
16120mm dia- Bend
162Construction of INSPECTION CHAMBER following clear sizes including earth work excavation, CC 1:5:10 of 10 cm thick and brick work in Cement Mortar 1:5 [One cement and Five sand] using best quality of Clay burnt Bricks of size 9” x 43/8” x 23/4” with Class designation of 7.5 and Plastering with Cement Mortar 1:3 [One Cement and Three Plastering Sand] 12 mm thick to inner and outer sides and wearing coat 1:3:6 [One Cement, Three crushed stone sand and Six Aggregate] 15 cm thick and covered with precast slab 5 cm thick etc., complete complying as directed by the departmental officers as per standard specification. (Size 600x600mm)
163Supply and delivery and fixing of HDPE tank as per IS 12701 / 1996 including loading, unloading, transportation and labour charges for fixing of the GI pipes and specials for pipe connection works including cutting, threading and fixing charges etc.,complying as directed by the departmental officers as per standard specification.
164Supply and delivery of Electric Monoblock pump conforming to IS 9079:2002 as amended from time to time, with CI FG 200 Casing, hydraulically and dynamically balanced Bronze grade LTB-2 impeller, impeller ring and casing ring, stainless steel shaft capable of discharging required quantity of water against a total head noted below due to all causes. Pump shall of BEE 3 Star Rated and capable of discharging the specified quantity at the head noted at the minimum NPSHA at site conditions. The shut off head shall be atleast 25% over and above the head at duty point. The pump shall be suitable for operation in AC three phase , 415 V+/- 10% , 50 Hz +/- 5%. Squirrel cage induction motor for continuous operation. The speed of the Pump and Motor shall be not less than 2700 to 2900 RPM respectively 100 lpm x 35 m head
165Supply and fixing of 1000W Automatic electric water heater of 25 liters capacity suitable for 230V 50 c/s AC Supply on Suitable MS Clamps with 3 core flex wire, but without plumbing works.
166Medical Gas Copper Pipeline arrangement to hang on the wall of socket type connection installation of seamless cleaned and degreased non arsenical phosphorous gas copper pipe line with saddles complete with brazing work including all copper fitting (tee, elbow, reducer, coupling). The copper pipelines should be tested suitable for a steam of working pressure of 17.34 kg. / cm2 (17 bar) and confirm to BS 864 Standard with specially made for brazed socket type connection. The medical gas copper pipeline should be tested as per standard and commissioning after painting as per International Code No. IS 2379/1963 Table-V. The pipelines installed at the various wings and floors etc., complete as directed by the Departmental Officers as per IS Code 12827 / 1989 & ISO 7396 / 1987 Specification. 10mm OD 0.90mm thick copper pipe
167Medical Gas Copper Pipeline arrangement to hang on the wall of socket type connection installation of seamless cleaned and degreased non arsenical phosphorous gas copper pipe line with saddles complete with brazing work including all copper fitting (tee, elbow, reducer, coupling). The copper pipelines should be tested suitable for a steam of working pressure of 17.34 kg. / cm2 (17 bar) and confirm to BS 864 Standard with specially made for brazed socket type connection. The medical gas copper pipeline should be tested as per standard and commissioning after painting as per International Code No. IS 2379/1963 Table-V. The pipelines installed at the various wings and floors etc., complete as directed by the Departmental Officers as per IS Code 12827 / 1989 & ISO 7396 / 1987 Specification. 28mm OD 0.90mm Thick Copper Pipe
168Gas Outlet Points: (Self sealing type - Single / DIN outlet pipe) with 'S' type bracket made up of copper and the out let of non-interchangeable for other gas. The outlet points are brazed with brass bracket with self sealing valve (Stainless Steel) with all accessories and complete set and are covered by plastic cover duly colour coated as per specific gas and button cover etc., complete as directed by the Departmental Officers and as per IS Code 12827 / 1989 & ISO 7396 / 1987 Specification.
169Brass Isolation Valve suitable for the copper pipe and should be of non lubricated 90 degree turn lever ball valve of reputed make, conneced in line with medical gas pipe line system by using suitable size brass valve adopter union, ferrule, nipple, rubber O' ring, tapion lap and etc. All pipe line regulators shall be capable of controlling pipe line pressure and must compatible with the requirements specified in IS 12827-1989. All valves should be pneumatically tested for twice the working pressure for the gas line as per IS Code 12827 / 1989 & ISO 7396 / 1987 Sepecification.15MM isolation Valve
170Brass Isolation Valve suitable for the copper pipe and should be of non lubricated 90 degree turn lever ball valve of reputed make, conneced in line with medical gas pipe line system by using suitable size brass valve adopter union, ferrule, nipple, rubber O' ring, tapion lap and etc. All pipe line regulators shall be capable of controlling pipe line pressure and must compatible with the requirements specified in IS 12827-1989. All valves should be pneumatically tested for twice the working pressure for the gas line as per IS Code 12827 / 1989 & ISO 7396 / 1987 Sepecification.28mm Isolation Valve
171Theatre Vaccum Unit: The unit should comprise of two reusable 2000 ml shatter resistant bottle. Each made up of ply carbonate material and fully autoclavable at 134 degreee centigrade, should have a vacuum regulator with instant ON / OFF switch and tree way left, right or both. All the above items should be mounted on a trolley having free moving castor wheels. (As per IS 12827 / 19898 & ISO 7396 / 1987)
172Flow Meter made up of Brass with Humidifier Bottle Flow Meter should be back pressure compressed and should be accurate gas flow measurement with control range 0-13 litres per minute. It should meet strict permission and dumbling standard. The meter body should be made of brass materials. The humidifier bottle should be made of unbreakable polycorbonate material and auto cleavable at 134 degree centigrate. The rate includes flow meter and its accessories (silicon tube with mask). The cost of materials including transport, etc., complete as per standard specification and as directed by the Departmental Officer and as per IS 12827 / 1989 and ISO 7396 / 1987 Specification.
173Ward Vaccum Unit with Gauge both mounted on a collection jar of capacity 600 ml and with a wall bracket for mounting it on the wall. The collecion jar should be made of unbreakable polycarbonate materials which is fully auto cleavable at 134 degree centigrade as per standard specification and as directed by the Departmental Officers and as per IS 12827 / 1989 and ISO 7396 / 1987 Specification. The rate includes cost of silicon hose with SS nipple on either side.
174Supply and fixing of stored pressure ABC (Mono Ammonium Phospate) Powder Type Fire Extinguisher of 6 kg. capacity as per IS:15683 with pressure gauge, discharge hose & control nozzle, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc, complete as per standard specification and as directed by the Departmental Officers.
175Supply and fixing of Carbon-di-Oxide Gas Type 2 kg. capacity Fire Extinguisher as per New IS15683, complete with control valve, discharge hose with horn, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc., complete as per standard specification and as directed by the Departmental Officers.
176Supply and fixing of Water CO2 Stored Pressure Type 9 litres capacity Fire Extinguisher as per new IS 15683 complete with control valve, gun metal cap, pressure gauge, operation sticker, discharge hose, wall mounting bracket, safety clip, etc., as directed by the Departmental Officers.
177Addressable Fire Alarm Control Panel consists of display board which will have 160 Character Display with Touch key pad, Mother board 32 Bit Processor, In-built RS-485Networking Circuit for peer to peer networking, In-built USB 2.0 Port, Loop Card having 254 devices of both detectors and modules in a single line circuit, SLC supports both Class A and Class B wiring Approval: UL Listed. Single loop panel
178Supply and fixing of Addressable Detectors with base with Binary coded address setting. Dual LED’s for 360° visibility. Heat Cum Smoke detector.
179Supply and fixing of Manual Call Point : Addressable Manual Call Point - Resettable type - with back box with Binary coded address setting with Status LED for 360° visibility
180Supply and fixing of Hooter Conventional type Horn / Strobe wall mounted type rated at 90 dBA @ 1m for Audible annunciation and 15cd minimum flashing at 1 Hz for visual indication.
181Supply and fixing of Fault Isolator Module capable of monitoring shorted loop circuit and automatically restore communications
182POWER SUPPLY : 24VDC Power Supply with 5 amp rating, having LED indications for Power supply ON,battery Fail,Battery Charging,battery back up etc.
183Supply and laying of following sizes of Armoured Aluminium Cables for electrical motor, control panel, pressure switch,jockey motor etc.. The rate inclusive of all incidental charges,neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. 2 core 1.5 sqmm aromoured aluminium cable Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56781657
AUTHORITY Local Bodies
TENDER VALUE 3.50 Crore
LAST DATE 17-08-2026
Authority
Authority Name Municipal Adminitration And Water Supply Department
Work Description Tender for Construction Of Additional Building At Government Hospital Coonoor In Coonoor Municipality
Basic Detail
Tender No E4/1364/2026/NHM - TN - 15th FC 2023-2024
Bidding Type Tender
Location
City Nilgiris
State Tamil Nadu
Key Dates
Publish Date 31 Jul 2026
Submission Date 17 Aug 2026
Open Date 17 Aug 2026
Finance
Tender Value 3.50 Crore
Tender Fee Ref. Documents
EMD 3.50 Lakhs
Exemption Not Available
Document List
biddocument350.pdf
BOQ_829553.xls
fea37fe7-ff1c-4465-9baf-865c0f278ccc.html
Tendernotice_1 (11).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 31, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 17, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 1 day
Aug 17, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day
Aug 17, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 1 day

Tender Documents

Download All (ZIP) ↓
pdf

biddocument350.pdf

xls

BOQ_829553.xls

html

fea37fe7-ff1c-4465-9baf-865c0f278ccc.html

pdf

Tendernotice_1 (11).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders