Tender For Rev Ing And Augmentation Of Existing Compound Lighting At Entire Compound Of Lok Bhavan Kolkata.
Tender Value
51.62 Lakhs
Estimated cost
Bid Submission
19 Aug 2026
2 days left
EMD
1.03 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kolkata → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Rev Ing And Augmentation Of Existing Compound Lighting At Entire Compound Of Lok Bhavan Kolkata.
BOQ
| Sl. No. | Item Description |
| 1 | Supplying and delivery of following size Armoured cables XLPE/PVC insulated are designed for 1.1 kV Stranded Aluminium conductor, high tensile galvanized steel wire/strip armour for mechanical protection, and PVC/FR PVC outer sheathing power cable of following size.(Make:-Gloster/Polycab/Havells/RR Kable) |
| 2 | 4 core 10 sqmm |
| 3 | 4 core 50 sqmm |
| 4 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. |
| 5 | Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 6 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 7 | Upto 35 sq. mm [CPWD(DSR)/10.1.1]/65 |
| 8 | Above 35 sq. mm and upto 95 sq. mm [CPWD(DSR)/10.1.2]/65 |
| 9 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. |
| 10 | Upto 35 sq. mm [CPWD(DSR)/10.5.1]/66 |
| 11 | Above 35 sq. mm and upto 95 sq. mm [CPWD(DSR)/10.5.2]/66 |
| 12 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade asrequired. [CPWD(DSR)/11] |
| 13 | 4 X 10 sq. mm (25mm) [CPWD(DSR)/11.1.32] |
| 14 | 4 X 50 sq. mm (35mm) [CPWD(DSR)/11.1.35] |
| 15 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required |
| 16 | 100 mm dia [CPWD(DSR)/15.13.1] |
| 17 | Supply & Installation of Out Door Type Feeder pillar box of Suitable size made with 5mm thick MS plate on 40X40X6mm angle iron frame having front open able hinged door with door handle and double locking arrangement, the box will be fixed on a MS angle Frame consisting four Nos legs of Suitable size . There should be proper ventilation spout at the centre of the top edge on either side. The pillar box should be erected over suitable brick structure with plaster and neat cement finish and to be painted by two coats of paints over two coats of primer. The pillar box should be provided with following fixtures. |
| 18 | INCOMING |
| 19 | 415V, 36KA, 200 Amp MCCB (L&T) – 1No. |
| 20 | 415 Volt 315 Amp Bus bar of 4 Nos. 40x5mm [Cu. Bar on heavy duty porcelain insulator with multi-color tapping & necessary drilled holes.] -1 Set. |
| 21 | OUTGOING: 415V, 63 Amp 4Pole MCB (L&T) – 2No |
| 22 | 415V, 32 Amp 4Pole MCB. (L&T) – 2No |
| 23 | Astronomical Timer (ASTRO MINI) -1No |
| 24 | LED Phase Indicating Lamps (RYB). – 1 Sets. |
| 25 | 50-550V Digital VAF+ PF Meter Cl 1 with associated 1A/5A CTs (L&T) –1set |
| 26 | EI Danger Board (6”X4”) – 1No. |
| 27 | Supply and Delivery of 7 MTRS GI OCTAGONAL POLE FABRICATED PART AS PER DIMENSION :T0P DIA - 70 mm, BOTTOM DIA -135 mm, (SECTION LENGTH - 7000 mm) THICKNESS - 3 mm,BASE PLATE - 220 mm x 220 mm x 12 mm.. FOUNDATION BOLT - M20 x 700 mm x 4 nos 'J' type bolts (Make: UTKARSH/TRANSRAIL/BAJAJ/VALMOST) |
| 28 | Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. [CPWD(DSR)/12]/72 |
| 29 | Above 6.5 Meter and upto 8.0 Meter |
| 30 | Supply and Fixing of double arm header assembly fabricated from 40mm dia. GI Pipe (ISI-M) of 1.5 Mtr. long rigidly welded with 100mm dia. GI Pipe (ISI-M) of 0.3 Mtr. long at an angle of 110⁰ & suitable angle between the two arms including S/F 3Nos ½” MS jam nut each with 1No. ½” dia. through bolt and painting the entire assembly. |
| 31 | Supply and Fixing of Single arm header assembly fabricated from 40mm dia. GI Pipe (ISI-M) of 1.5 Mtr. long rigidly welded with 100mm dia. GI Pipe (ISI-M) of 0.3 Mtr. long at an angle of 110⁰ & suitable angle between the two arms including S/F 3Nos ½” MS jam nut each with 1No. ½” dia. through bolt and painting the entire assembly. |
| 32 | Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. [CPWD(DSR)/13.34]/78 |
| 33 | Supplying & Fixing PVC Syntex waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 3 A MCB, one 3 Ph DMC Connector,one NL on porcelain insulator, one compression type brass cable gland for up to 2- core 16 sq.mm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint. |
| 34 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (Make: GLOSTER/POLYCB/RRKABEL) |
| 35 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire. [CPWD(DSR)/1.14.1]/3 |
| 36 | Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5,Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output.LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). [CPWD(DSR)/8.14.15]/52 (Make: Signify/Wipro/LT) |
| 37 | 100 Watt [CPWD(DSR)/8.14.15] |
| 38 | 150 Watt [CPWD(DSR)/8.14.17] |
| 39 | Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection,EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80extra polation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cableand earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shallbe submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). (Make: Signify/Wipro/LT) |
| 40 | 200 Watt [CPWD(DSR)/8.17.5]/65 |
| 41 | 250 Watt [CPWD(DSR)/8.17.6]/65 |
| 42 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. [CPWD(DSR)/5.2]/30 |
| 43 | Supplying and laying 6 SWG G.I. wire at 0.50 Meter below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. [CPWD(DSR)/5.7]/31 Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 01, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 19, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysAug 21, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender