| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil (As per DSR 2.8.1) |
| 2 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) (As per DSR 6.4.1) |
| 3 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) (As per DSR 6.1.1) |
| 4 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform (As per DSR 5.9.3) |
| 5 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (As per DSR 5.3) |
| 6 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more (As per DSR 5.22A.6) |
| 7 | 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) (As per DSR 13.16.1) |
| 8 | Pointing on brick work or brick flooring with cement mortar 1:3 (1 cement : 3 fine sand): Flush / Ruled/ Struck or weathered pointing (As per DSR13.31.1) |
| 9 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and makingpattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. “All above operations to be done in order and as directed and specified by the Engineer-in-Charge”: With average thickness of 120 mm and minimum thickness at khurra as 65 mm (As per DSR 22.7.1) |
| 10 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase (As per DSR 12.21.1) |
| 11 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. (As per DSR 12.22) |
| 12 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre (As per DSR 13.41.1) |
| 13 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) (As per DSR 13.46.1) |
| 14 | Providing and laying cement concrete in retaining walls, return walls,walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses,parapets, coping, bed blocks, anchor blocks, plain window sills, fillets,sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) (As per DSR 4.2.3) |
| 15 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. (As per DSR 15.6) |
| 16 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (As per DSR 5.2.2) |
| 17 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers (As per DSR 5.9.5) |
| 18 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. (As per DSR 5.22.6) |
| 19 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:5:10 (1 cement : 5 coarse sand (zone-Ill) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) (As per DSR 22.5) |
| 20 | Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8 mm having with water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20 mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge (As per DSR 16.9) |
| 21 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) (As per DSR 4.1) |
| 22 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, hannels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) (As per DSR 10.28) |
| 23 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. (As per DSR 15.56) |
| 24 | 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement: 4 fine sand) (As per DSR 13.2.1) |
| 25 | Finishing walls with Acrylic Smooth exterior paint of required shade : Old work (One or more coat applied @ 0.90 ltr/10 sqm) (As per DSR 13.111.2) |
| 26 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour. Old work (one or more coats) (As per DSR 13.81.1) |
| 27 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work (As per DSR 13.99.1) |
| 28 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. (As per DSR 13.91) |
| 29 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete (As per DSR 13.80) |
| 30 | Providing and applying cement based putty (Birla, Jk or equivalent) to the required finish complete in all respect and to the entire satisfaction of Engineer-in-charge. (N.S.) |
| 31 | Providing and finishing walls of existing brickwork/ pointing face/ plastered surface finished with acrylic smooth exterior paint at various dispensaries in Chandigarh having pre-defined shade/ colour (of make Asian paint, Berger paint equivalent.) as per guidlines of Govt. of India under \\"Ayushman Bharat schemes\\". The painting colour schemes includes patterns, illustrations, National Health mission logo, Ayushman Bharat logo along with perimeters of doors, windows, ventilation and like. the size, dimensions and design of logo is as per drawing supplied by client department. The rates further includes the cost of priming/preparing base smooth for painting complete in all respect and to the entire satisfaction of E.I.C in time bound manner (N.S.) |
| 32 | Providing and fixing PVC rain water pipe 6\\" dia., 6kg/sqm complete in all respects with elbow, socket and clamp and to the entire satisfaction of Engineer-in-charge (N.S.) |
| 33 | Providing and fixing 35mm thick phenol bounded factory manufactured solid flush door shutter ISI marked with both side commercial face in the existing chowkhat. The rate includes the cost of iron hinges, all necessary Aluminium fittings and painting two coats over one coat of primer after preparation of surface (special quality) complete in all respect to the entire satisfaction of Engineer-in-charge. (N.S.) |
| 34 | Providing and fixing golden champ wood chowkhat (kiln seasoned) 4 1/2\\" x 2 1/4\\"including cost of corner straps, iron hold fasts, hinges, screws,nails, fevicol etc. and painting two coats of wood preserver to sides of chowkhats. Rate includes the cost of dismantling of all damaged chowkhats and making good the damage to walls plaster and floors as required including, disposal of rubbish to the dumping ground the rate further includes the cost of painting two coats synthetic enamel paint over one coat of wood primer complete in all respect and to the entire satisfaction of Engineer-in-Charge (N.S.) |
| 35 | Providing and laying antiskid ceramic floor tiles of specified size (thickness to be specified by the manufacturer) of 1st quality with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), the tiles are to be fixed by using 2mm grove spacers., complete. Size of Tile 300x300 mm. (N.S.) |
| 36 | Providing and laying vitrified floor tiles of specified size 600x600 mm single charge (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved brand and manufacture, in all colours and shades,The tiles are to be fixed with 3mm grove using spacers, The tiles are to be laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm The groves are to be filled with cementious grout mix with prportion of 0.90 kg grout and 0.10 kg of hardner for each kg of Filling material . Single Charge vitrtified Tile of size 600x600 mm (N.S.) |
| 37 | Providing and laying vitrified floor tiles of specified sizes (thickness to be specified by the manufacturer) of 1st quality with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, in skirting, The tiles are to be fixed with 3mm grove using spacers, The tiles are to be laid on 12mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm The groves are to be filled with cementious grout mix with prportion of 0.90 kg grout and 0.10 kg of hardner for each kg of Filling material . Single Charge vitrtified Tile of size 600x600 mm (N.S.) |
| 38 | Providing and laying 1st quality ceramic glazed wall tiles of size 300x450 mm conforming to IS : 15622 (thickness to be specified by the manufacturer) of approved make, in all colours, shades as approved by Engineer-in-Charge,in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand). The tiles are to be fixed by provding 2 mm thick spacer. The area of spacer is to be filled by using cement based grout of approved shade. The grooves are to be filled with cemenitious grout mix with proportion of 0.90 kg grout and 0.10 kg of hardener for each kg of filling material complete in all respect and to entire statisfaction of Engineer-in-Charge. (N.S.) |
| 39 | Dismantling of ceramic tiles or vitrified and plaster to making the surface clean for refixing the glazed tiles including removing of malba complete in all respect and to the entire satisfaction of the Engineer in charge. (N.S.) |
| 40 | Providing and fixing 15 to 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble ( Based on DSR No. 8.2.1.2) (N.S.) |
| 41 | Repair of deteriorated RCC Balconies, Beams, Walls, Ceiling, Column or other concrete surface having exposed rusted bars consisting of following operations (a) chipping of concrete surface 25mm thick average depth afterwards remocal of loose concrete and exposing the steel bars. Cleaning the surface properly to remove dust particles and rust from the steel bars. (b) Moistening the surface properly and applying arcylic polymer (acrocrete/ pidilite/ mastercrete or its equivalent) coating mixed with cement for proper bonding of old and new concrete in two coats 0.2kg per 1kg of cement. (c) Providing and fixing chicken mesh of standard size and 26 guage with steel reinforcement by using binding wire and nails complete. (d) Proving and placing of cement concrete l:11/2:3 having average thickness 1\\" (3/4\\" to 11/4\\" thick) mixed with arcylic polymer admixture @ 1kg per bag of cement and waterproof agent @ 400ml per 2 bags of cement including finishing the surface complete in all respect as per the direction and to the entire satisfaction of Engineer-in-Charge. (N.S.) |
| 42 | Cutting/Dismantling of existing broken and required floor and wall tile using electric cutter,chisel hammer.etc wherever required complete in all respect and removel of malba within 50 meter lead clean the surface thoroughly as per the direction and to the entire satisfaction of Engineer in charge (N.S.) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 01, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysAug 10, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender