Tender For repair maintenance E&M Services At Chhatrasal Stadium, Model Town, Delhi. (Sh:- Operation & Maintenance Of electrical installation & Fans, Sub-Station, Dg Set, Fire Alarm, Wet Riser Cum Sprinkler System, Fountain, Pump Sets & Annual Compre
Tender Overview
Project Description
Tender for repair maintenance E&M Services At Chhatrasal Stadium, Model Town, Delhi. (Sh:- Operation & Maintenance Of electrical installation & Fans, Sub-Station, Dg Set, Fire Alarm, Wet Riser Cum Sprinkler System, Fountain, Pump Sets & Annual Comprehensive Maintenance And Operation Of 3 X 140 Tr Central Ac Plant Blue Star Make, Comprehensive Maintenance And Operation Of Existing Mitel-Astra And Coral Make Digital Telephone Exchange).
BOQ
| Sl. No. | Item Description |
| 1 | SH-I EI WorkProviding skilled and unskilled staff for operation and routine maintenance of electrical and mechanical installations at Chhatrasal Stadium as per the inventory and as per direction of Engineer-in-charge & as per the terms and conditions for the following works:-a) For operation and routine maintenance of EI & Fans, DG Set.i) Wireman cum Operator - 03 Nos. (One in each shift (6 AM to 2 PM, 2 PM to 10 PM & 10 PM to 6 AM)) ii) Khallasi - 03 Nos. (One in each shift (6 AM to 2 PM, 2 PM to 10 PM & 10 PM to 6 AM))b) For operation and routine maintenance of Fire Alarm and Wet Riser cum Sprinklar System.i) Wireman cum Operator - 03 Nos. (One in each shift (6 AM to 2 PM, 2 PM to 10 PM & 10 PM to 6 AM)) ii) Khallasi - 03 Nos. (One in each shift (6 AM to 2 PM, 2 PM to 10 PM & 10 PM to 6 AM))c) For operation and routine maintenance of RO Plant, Water Supply pump sets and Fountain.i) Wireman cum Operator - 03 Nos. (One in each shift (6 AM to 2 PM, 2 PM to 10 PM & 10 PM to 6 AM))ii) Khallasi - 01 No. in General shift (9 AM to 5 PM)d) Operation and routine maintenance of 13 Passengers Lifti) Lift Operator - 02 Nos. (One in each lift (9 AM to 5 PM)) |
| 2 | Lifting of existing submersible bore well / open well 3 HP to 15 HP capacity Pump set from the bore well with the help of chain pulley block & tripod stand i/c cartage charge at site from the work shop. |
| 3 | Lowering of 3 HP to 15 HP capacity bore well/open well pumpset in the bore well with the help of chain pulley block and tripod stand i/c cartage charge pump set from work shop to site. |
| 4 | Repairing of Mono submersible motor upto 7.5 HP complete dismantling and carrying out the following works i/c cartage pf pump to and from site to workshop i/c credit of dismantle, testing & commissioning etc as required.Motor bush bearing - 1 No.Rotor sleeve polishing grinding - 1 No.Motor seal - 04 Nos.Motor Studs - 01 No. |
| 5 | Rewinding of Mono submersible motor upto 7.5 HP complete dismantling and carrying out the following works i/c cartage pf pump to and from site to workshop i/c credit of dismantle, testing & commissioning etc as required. |
| 6 | Charges for hiring of Tower wagon/ Hydra of suitable height for installation of stands light/ fixing of cable etc complete as reqd. as per the direction of Engineer-incharge. |
| 7 | Supply of following materials (Note:- No labour is considered for fixing of these items.)5/6 A switch (Modular type) |
| 8 | 15/16 A switch (Modular type) |
| 9 | 3 pin 5/6 A socket outlet (Modular type) |
| 10 | 6 pin 15/16 A socket outlet (Modular type) |
| 11 | Step Type Modular Fan Regulator (switch type) |
| 12 | 5/6 A switch (Piano Type) |
| 13 | 15/16 A switch (Piano type) |
| 14 | 3 pin 5/6 A socket outlet (Piano type) |
| 15 | 6 pin 15/16 A socket outlet (Piano type) |
| 16 | Bell Push (Piano type) |
| 17 | PVC Batten/ Angle Holder |
| 18 | 1 or 2 Module Cover plate |
| 19 | 3 Module Cover plate |
| 20 | 6 Module Cover plate |
| 21 | 8 Module Cover plate |
| 22 | 12 Module Cover plate |
| 23 | 1.5 Sq.mm. ISI marked, FRLS PVC insulated, single core copper conductor cable |
| 24 | 4 Sq.mm. ISI marked, FRLS PVC insulated, single core copper conductor cable |
| 25 | 6A to 32 A, ratings, SP MCB, \\"C\\" curve, 10 KA breaking capacity |
| 26 | 6A to 32 A, ratings, SPN MCB, \\"C\\" curve, 10 KA breaking capacity |
| 27 | 3 pole MCCB, 100A, 16kA (Ics = 100% Icu) |
| 28 | 3 pole MCCB, 200A, 25kA (Ics = 100% Icu) |
| 29 | 4 pole MCCB, 400A, 50kA (Ics = 100% Icu) |
| 30 | 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) ceiling fan with Brush Less Direct Current (BLDC) Motor, etc. complete as req |
| 31 | 18-22 watt4 feet indoor commercial LED Batten light (System lumen efficacy ≥105 <120 lm/Watt) Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) |
| 32 | 36 watt4 feet indoor commercial LED Batten light (System lumen efficacy ≥105 <120 lm/Watt) Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) |
| 33 | 40 Watt LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt) Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) |
| 34 | 120 Watt LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥105 <120 lm/Watt) |
| 35 | 250 Watt LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy 105 <120 lm/Watt) |
| 36 | 12-15 Watt LED Down lighter (SMD Type) (System lumen efficacy ≥ 105 < 120 lm/Watt ) Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector |
| 37 | 18 Watt LED Down lighter (SMD Type) (System lumen efficacy ≥ 105 < 120 lm/Watt ) Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector |
| 38 | 2.5 mfd capacitor |
| 39 | 3.15 mfd capacitor |
| 40 | Heavy duty metal exhaust fan of 300 mm sweep 900 rpm. |
| 41 | Heavy duty metal exhaust fan of 380 mm sweep 1400 rpm. |
| 42 | 40/63 A DP , MCB 10KA rating \\"C\\" Curve |
| 43 | 63 A TP , MCB 10KA rating \\"C\\" Curve |
| 44 | SH-II Sub-Station workServicing and overhauling of HT 400/630/800 Amp VCB complete etc. as required i/c routine yearly check up and reports etc. as well as testing & calibration of micro processor controlled relay of HT panel routine test etc. as reqd. with the help of relay testing machine etc. as required (a) O/C relay-2 nos. (b) Earth fault relay-1 no. (c) Master relay-1 no. (d) Trip circuit supervision relay-1 no Please Enable Macros to View BoQ information |
| 45 | SH-II Sub-Station workServicing and overhauling of HT 400/630/800 Amp VCB complete etc. as required i/c routine yearly check up and reports etc. as well as testing & calibration of micro processor controlled relay of HT panel routine test etc. as reqd. with the help of relay testing machine etc. as required (a) O/C relay-2 nos. (b) Earth fault relay-1 no. (c) Master relay-1 no. (d) Trip circuit supervision relay-1 no Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender