| Sl. No. | Item Description |
| 1 | A) Erection Part |
| 2 | 11kV HT Line |
| 3 | Erection of S.T Single Pole Str. 11 Mtr. Long :- Digging of Pit fixing of insulator, disc and drilling of holes in X-Arm , Bracing Set, Top Clamp, erection of pole, fixing of barbed wire and danger plate, filling of Pit , Alluminium Paint and ramming & painting of poles complete in all respect. |
| 4 | Stringing and sagging conductor:- Laying of conductor stringing and sagging, binding with insulator complete in all respect. |
| 5 | Laying of G.I Wire, Stringing, Sagging and binding complete in all respect. |
| 6 | Fixing of earthing pipe of pit for coal earthing, fixing of G.I wire to system filling of pit and remaning work complete in all respect. |
| 7 | Erection of Stay Set HT:- Digging of Pit fixing of Stay Rod, filling of Pit, Nozeiling & Tightning complete in all respect. |
| 8 | Erection iof GO/DO Fuse Switch |
| 9 | 11kV Isolator Motorised (12kV, 1250A,25kA) without earth switch. ( Santokhgarh local feeder Near Holi Khad Santokhgarh ) |
| 10 | Inspection fees for initial or peroodical inspection for 11kv HT Line |
| 11 | Providing manual carriage and transportation of departmental materials from Central Store to the work site by the contractor at his own arrangement, including loading, unloading, handling, stacking, labour, tools & plants, transportation vehicles, fuel, watch and ward, and all other incidental charges complete in all respects as directed by the Engineer-in-Charge. |
| 12 | LT Line |
| 13 | Erection of LT line. Digging of pit, erection of Steel pole 8 mtr long, erection of C.I X-arm, Shakle insulators, D-iron and filling of pit and remming etc complete in all respect. |
| 14 | Erection of stay Set.:- Digging of pit of stay, fixing of stay rod, noziling and tightening and filling of pit ramming etc.complete in all respect. |
| 15 | Erection of Earthing Set.:- Digging of Pit, Fixing of GI Wire To The Earth System and Filling of Pit etc.complete in all respect. |
| 16 | Laying of conductor :- Laying of conductor, striging, sagging and biding with insulator with 7/2.50mm/7/3.15 mm Conductor aug. of New 3-Ph. Re-cond, 7/3.15 mm for 1-Ph. LT complete in all respect., |
| 17 | Laying of G.I Wire, Stringing, Sagging and binding complete in all respect. |
| 18 | Inspection fees for initial or peroodical inspection for LT Line |
| 19 | Providing manual carriage and transportation of departmental materials from Central Store to the work site by the contractor at his own arrangement, including loading, unloading, handling, stacking, labour, tools & plants, transportation vehicles, fuel, watch and ward, and all other incidental charges complete in all respects as directed by the Engineer-in-Charge. |
| 20 | 11/0.4kV,63 KVA Sub-Station |
| 21 | Erection of 63 kva S/Stn. Str.:-Digging of Pit for S/T Pole and earthing, drilling of holes in X-arm, preparation of plate form str. Member CI, Alluminium Paint AI i.e X-arml, Knee bracing set, erection of D-pole,errection of plate form, ercetion of x-Arm, drop out, fuse unit, linghting arrestor, MCCB Switch of LT Box, Energy Meter, Erection of T/F, and earthing conn. to T/F G.O Switch lightning etc. erection of Stay Set, Erection of Jumper, Pipe earthing 3 Nos., Erection of LT cable, brabed wire and painting, 3 Nos. earthing to S/Stn. by prov. 50Kg Salt charcole in each earthing i/c construction of trench for earthing as per REC Board Standard complete in all respect. |
| 22 | Providing manual carriage and transportation of departmental materials from Central Store to the work site by the contractor at his own arrangement, including loading, unloading, handling, stacking, labour, tools & plants, transportation vehicles, fuel, watch and ward, and all other incidental charges complete in all respects as directed by the Engineer-in-Charge. |
| 23 | Inspection fees for initial or peroodical inspection for 11/0.4kv,63 kva Sub-Station. |
| 24 | SUPPLY PART |
| 25 | 11kV HT Line |
| 26 | Prov. Steel Tublar 11 mtr long with cap. |
| 27 | Prov. RCC Muff |
| 28 | Prov.AAAC 7/4.26 mm Conductor |
| 29 | Prov.G.I.Wire No. 8 SWG in mtr. |
| 30 | Run Through Str. ( ∆) Formation on Singlr Pole Str. |
| 31 | Prov. Cross Arm (Channel Iron (100x50x6) Length 1270 mm |
| 32 | Prov. Angle Iron (50x50x6mm) Leggth 750 mmx2 |
| 33 | Prov. Pole Top Bracket (MSCI) (100X50X6 mm) Length 100 mm |
| 34 | Prov.MS Half Clamp |
| 35 | Prov.MS Full Clamp |
| 36 | Prov.Barbed Wire |
| 37 | Prov.Eye/Earth Hook |
| 38 | Prov.11kv Pin Insulator with pin complete in all respect |
| 39 | Prov.11kv Stay Set |
| 40 | Prov. Stay Wire (7/3.15 mm) (10 kg. per Stay Set) |
| 41 | Prov.11kv Earthing set complete in all respect. |
| 42 | Prov.Red Oxide (1.5 Ltr. Per Pole) |
| 43 | Prov.Alluminum Paint |
| 44 | GO Switche |
| 45 | Prov. 11kv D.O.Fuse unit. |
| 46 | Prov.11kv Danger Plate (250x200x1.6 mm) |
| 47 | Providing and replacement of old damaged GO Switches at various 11/0.4 kV Distribution Sub-Stations and T-Off Points under the jurisdiction of HPSEBL, including dismantling of existing damaged GO Switches and installation, testing and commissioning of new 11 kV, 400 Amp, 25 kA Triple Pole Outdoor Type GOAB Switch Units complete in all respect, as per HPSEBL specifications and directions of the Engineer-in-Charge Location (11/0.4 kV, 250 kVA (JK) Jakhera, 250 kVA (BTA) Bhatoli, 100 kVA (JKC-1st) Jakhera and T-Off Point Jakhera under ESD HPSEBL Mehatpur and Existing 11KV Nangran Feeder, 11KV Una-Santokhgarh Feeder and 11KV Nangran Feeder near Jatpur village) |
| 48 | Prov. 11kv D.O.Fuse unit. |
| 49 | 11kV Isolator Motorised (12kV, 1250A,25kA) without earth switch. ( Santokhgarh local feeder Near Holi Khad Santokhgarh ) |
| 50 | LT Line |
| 51 | Steel Pole 8 mtr. Long. |
| 52 | AAAC 7/3.15 mm2 Conductor (Provided By HPSEBL) |
| 53 | GI Wire |
| 54 | RCC Muff |
| 55 | Channel Iron (75x40x5) [Length-1.50 Mtr + 0.2 Mtr] |
| 56 | Full Clamp |
| 57 | Half Clamp for Cross Arm |
| 58 | Nut and Bolts |
| 59 | Shackle Insulator with D-Iron |
| 60 | Earth Hook/Eye Hook Bolt |
| 61 | Stay Set Complete (i/c stay clamp) |
| 62 | Stay Wire (7/3.15mm) (6.0 kg per stay set) |
| 63 | Earthing Set Complete (preferbly coil earthing) |
| 64 | Aluminium Paint |
| 65 | Red Oxide |
| 66 | PVC Spacers |
| 67 | 11/0.4kV,63 KVA Sub-Station |
| 68 | Distribution Transformer (Ordinary) 11/0.4 KV, 63 KVA |
| 69 | Steel Tubular Poles (9 m, Working load>200Kgf/m2) |
| 70 | Muffs with concrete filling |
| 71 | X-Arm (Channel Iron (100X50X6mm) Length 2800mm X 2 No's) for incomer Line. |
| 72 | MS Angle Iron (50X50X5mm) Length 2800mm x1 No's for LA's . |
| 73 | X-Arm (Channel Iron (75X40X6mm) Length: ( 2800mm x 4 No's) for supporting DO fuse unit & GO switch |
| 74 | Providing and Fixing wooven mesh fencing along with Gate & locking arrangement (for more detail check attached drawing and measurement detail) |
| 75 | Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m. |
| 76 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand) : 8 graded stone aggregate 40 mm nominal size) |
| 77 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement- All work up to plinth level 1:1.5:3 (1 cement : 1.5 coarse sand): 3 graded stone aggregate 20 mm nominal size) |
| 78 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. wherever required, all complete In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 79 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge Made of G.I. wire of dia 4 mm |
| 80 | Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc. complete 100x58x1.90 mm |
| 81 | Providing and fixing ISI markedoxidisedM.S. sliding door bolts with nuts and screws etc. complete : 250x16 mm |
| 82 | Transformer Belting & Knee Bracing |
| 83 | X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for Transformer Bed |
| 84 | X-Arm [Channel Iron (100x50x6 mm), Length : (460 mm) x 2 Nos for supporting Main Channel of Transformer] |
| 85 | MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos |
| 86 | MS Angle Iron (35X35x5 mm), Length : (460 ) x 2 Nos |
| 87 | MS Angle Iron (50X50x6 mm), Length : (950 mm) x 2 Nos for Bed Knee Bracing |
| 88 | Transformer LT Distribution Box and GO Switch fixing Assembly |
| 89 | MS Angle Iron (50X50x6 mm), Length: (2800 mm) x 2 Nos |
| 90 | MS Angle Iron (50X50x6 mm), Length: (450 mm) x 1 Nos |
| 91 | GO Switch Handle Supporting: [Channel Iron (75x40x6 mm), Length: 460 mm |
| 92 | GO AB Switch Unit (11kV, 400A, 25 KA) Tripple pole O/D type |
| 93 | D.O Fuse Unit |
| 94 | Surge Arrester, 9 kV Station Class (Porcelain Type) |
| 95 | Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) |
| 96 | Stay set complete |
| 97 | Stay Wire (7/3.15 mm) (7.0 kg per Stay Set) |
| 98 | Pipe Earthing Set |
| 99 | LT Distribution Panel Box with MCCB (160A, 10 kA, 4P,1 no) and MCCB (SFU 32 A 5No. rewirable) |
| 100 | Half Clamp (M.S. Flat 50X6 mm) |
| 101 | Full Clamps (M.S. Flat 50X6 mm) |
| 102 | Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm Φ or more (with flat and spring washers)] |
| 103 | Aluminium Thimble |
| 104 | Aluminium Thimble |
| 105 | Danger Plate |
| 106 | Barbed Wire |
| 107 | LT Cable (3.5 Core) 70 mm² outgoing |
| 108 | LT Cable (3.5 Core) 120 mm² Incoming |
| 109 | Smart Meter for 63KVA Transformer. |
| 110 | Aluminium Paint. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender