Bids Are invited for Annual Maintenance Service - Desktops, Laptops And Peripherals - As Per Tender Document; As Per Tender Document - Printer , Computers , Network Switch , Io Nodes , Ups , Ups , Manpower , Supply, Installation, Testing, And Commiss
Tender Overview
Project Description
Bids Are invited for Annual Maintenance Service - Desktops, Laptops And Peripherals - As Per Tender Document; As Per Tender Document - Printer , Computers , Network Switch , Io Nodes , Ups , Ups , Manpower , Supply, Installation, Testing, And Commissioning Advance Maintenance Free Environment Friendly Chemical Earthing System Consisting Of Earth Pit Minimum Dia 150 Mm Size With 2/3Mtr Length, 50 Mm Dia Earth Electrode Molecular Bonded Copper On Outer Surface ( Minimum Copper Bonding Thickness 250 Microns) And Pre-Filled With Hygroscopic Powder With Terminals Connect Conductor And The Electrode Shall Be Surrounded By Suitable Powered From Beemoist(Backfilling Compound) Of Quantity Should Not Be Less Than 25 Kgs 2 Bags With Each Of Provided Maximum Contact Between The Electrode And Soil Sand With Complete Masonry Work. The Life Span For Chemical Earthing / Materials Should Be 10 Years. , Providing And Laying Earth Connections From Earth Electrode With Earth 8 Swg Dia Copper Wire In 15 Mm G.I Pipe (B Class) From Earth Electrode As Required & After Completion Of Earth Work, Earthing Parameter N-E Between 0.1 V To 2.0 V And As Per Direction Of Competent Authority. , Supply And Complete Installation Of Cat-6 Lan Cable Inside Pvc Conduit With Required Accessories (Including Saddle, Flexible Pipe, Tie, Band Etc.) Of Standard Oem And As Per The Direction Of Competent Authority. , Supply And Fixing Of Cat-6 Io Boxes With Cover For Lan (Gang Box, Faceplate & Io Port) Standard Oem.Numbering Tag On Each Io Box & Plastic Tag Strip On Each Cable And As Per The Direction Of Competent Authority. , Supply And Fixing Of Patch Panel -24 Port D-Link , Supply And Fixing Of Cat-6 Patch Chord 3 Meter Long , Supply And Fixing Of Cat-6 Patch Chord 1Mtr Long , Supply And Fixing Of 12U Data Rack-D-Link , Supply And Fixing Of Power Extension (6-Socket) Inside Rack , Supply, Fixing & Proper Configuration Of 24 Port Lan Edge Switch - Cisco Cbs350 24 Port With Poe & Sfp Port On Esic Network , Supply, Fixing & Proper Configuration Of 24 Port Lan Edge Switch - Cisco 3750 With Poe & Sfp Port On Esic Network , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface/Recessed Steel/ Pvc Conduit As Required. (Isi Marked) In Meter , 3 X 1.5 Sq. Mm , 3 X 2.5 Sq. Mm , 3 X 4 Sq. Mm , Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. (Isi Marked) In Meter , 25Mm , 32Mm , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. (Isi Marked) Each , 5/6 A Switch , 15/16 A Switch , 3 Pin 5/6 A Socket Outlet , 6 Pin 15/16 A Socket Outlet , Telephone Socket Outlet , Supplying And Fixing Following Size/ Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required. (Isi Marked) Each , 6 Modules (200 Mmx75 Mm) , 8 Modules (125 Mmx125 Mm) , 12 Modules (200 Mmx150 Mm) , Supplying And Fixing Following Modular Base & Cover Plate On Existing Modular Metal Boxes Etc. As Required. (Isi Marked) Each , 6 Modules , 8 Modules , 12 Modules , Supplying And Fixing 5 A To 32 A Rating, 240/415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. (Isi Marked) Each , Single Pole , Single Pole And Neutral , Double Pole , Triple Pole , Triple Pole And Neutral
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 12-Aug-2026 | 19-Aug-2026 |
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | Printer | Printer |
| 2 | Computers | Computers |
| 3 | Network Switch | Network Switch |
| 4 | IO Nodes | IO Nodes |
| 5 | UPS | UPS |
| 6 | UPS | UPS |
| 7 | Manpower | Manpower |
| 8 | Supply, installation, testing, and commissioning advance maintenance free environment friendly chemical earthing system consisting of earth pit minimum dia 150 mm size with 2/3mtr length, 50 mm dia earth electrode molecular bonded copper on outer surface ( minimum copper bonding thickness 250 microns) and pre-filled with hygroscopic powder with terminals connect conductor and the electrode shall be surrounded by suitable powered from BEEMOIST(Backfilling Compound) of quantity should not be less than 25 kgs 2 bags with each of provided maximum contact Between the electrode and soil sand with complete masonry work. The life span for chemical earthing / materials should be 10 years. | Supply, installation, testing, and commissioning advance maintenance free environment friendly chemical earthing system consisting of earth pit minimum dia 150 mm size with 2/3mtr length, 50 mm dia earth electrode molecular bonded copper on outer surface ( minimum copper bonding thickness 250 microns) and pre-filled with hygroscopic powder with terminals connect conductor and the electrode shall be surrounded by suitable powered from BEEMOIST(Backfilling Compound) of quantity should not be less than 25 kgs 2 bags with each of provided maximum contact Between the electrode and soil sand with complete masonry work. The life span for chemical earthing / materials should be 10 years. |
| 9 | Providing and laying earth connections from earth electrode with earth 8 SWG dia copper wire in 15 mm G.I pipe (B class) from earth electrode as required & after completion of earth work, earthing parameter N-E between 0.1 V to 2.0 V and as per direction of competent authority. | Providing and laying earth connections from earth electrode with earth 8 SWG dia copper wire in 15 mm G.I pipe (B class) from earth electrode as required & after completion of earth work, earthing parameter N-E between 0.1 V to 2.0 V and as per direction of competent authority. |
| 10 | Supply and complete installation of CAT-6 LAN cable inside PVC conduit with required accessories (including saddle, flexible pipe, tie, band etc.) of standard OEM and as per the direction of competent authority. | Supply and complete installation of CAT-6 LAN cable inside PVC conduit with required accessories (including saddle, flexible pipe, tie, band etc.) of standard OEM and as per the direction of competent authority. |
| 11 | Supply and fixing of Cat-6 IO boxes with cover for LAN (Gang box, faceplate & IO port) standard OEM.Numbering tag on each IO box & plastic tag strip on each cable and as per the direction of competent authority. | Supply and fixing of Cat-6 IO boxes with cover for LAN (Gang box, faceplate & IO port) standard OEM.Numbering tag on each IO box & plastic tag strip on each cable and as per the direction of competent authority. |
| 12 | Supply and fixing of Patch Panel -24 port D-Link | Supply and fixing of Patch Panel -24 port D-Link |
| 13 | Supply and fixing of Cat-6 Patch chord 3 meter long | Supply and fixing of Cat-6 Patch chord 3 meter long |
| 14 | Supply and fixing of Cat-6 Patch chord 1mtr long | Supply and fixing of Cat-6 Patch chord 1mtr long |
| 15 | Supply and fixing of 12U Data Rack-D-Link | Supply and fixing of 12U Data Rack-D-Link |
| 16 | Supply and fixing of Power extension (6-Socket) inside rack | Supply and fixing of Power extension (6-Socket) inside rack |
| 17 | Supply, fixing & proper configuration of 24 Port LAN Edge Switch - Cisco CBS350 24 Port with PoE & SFP port on ESIC network | Supply, fixing & proper configuration of 24 Port LAN Edge Switch - Cisco CBS350 24 Port with PoE & SFP port on ESIC network |
| 18 | Supply, fixing & proper configuration of 24 Port LAN Edge Switch - Cisco 3750 with PoE & SFP port on ESIC network | Supply, fixing & proper configuration of 24 Port LAN Edge Switch - Cisco 3750 with PoE & SFP port on ESIC network |
| 19 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. (ISI marked) in meter | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. (ISI marked) in meter |
| 20 | 3 x 1.5 sq. mm | 3 x 1.5 sq. mm |
| 21 | 3 x 2.5 sq. mm | 3 x 2.5 sq. mm |
| 22 | 3 x 4 sq. mm | 3 x 4 sq. mm |
| 23 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (ISI marked) in meter | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (ISI marked) in meter |
| 24 | 25mm | 25mm |
| 25 | 32mm | 32mm |
| 26 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (ISI marked) Each | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (ISI marked) Each |
| 27 | 5/6 A switch | 5/6 A switch |
| 28 | 15/16 A switch | 15/16 A switch |
| 29 | 3 pin 5/6 A socket outlet | 3 pin 5/6 A socket outlet |
| 30 | 6 pin 15/16 A socket outlet | 6 pin 15/16 A socket outlet |
| 31 | Telephone socket outlet | Telephone socket outlet |
| 32 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. (ISI marked) Each | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. (ISI marked) Each |
| 33 | 6 Modules (200 mmX75 mm) | 6 Modules (200 mmX75 mm) |
| 34 | 8 Modules (125 mmX125 mm) | 8 Modules (125 mmX125 mm) |
| 35 | 12 Modules (200 mmX150 mm) | 12 Modules (200 mmX150 mm) |
| 36 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. (ISI marked) Each | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. (ISI marked) Each |
| 37 | 6 Modules | 6 Modules |
| 38 | 8 Modules | 8 Modules |
| 39 | 12 Modules | 12 Modules |
| 40 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (ISI marked) Each | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (ISI marked) Each |
| 41 | Single pole | Single pole |
| 42 | Single pole and neutral | Single pole and neutral |
| 43 | Double pole | Double pole |
| 44 | Triple pole | Triple pole |
| 45 | Triple pole and neutral | Triple pole and neutral |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 4 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender