Banking and Finance Government Departments Closing in 4 days TDR #56774370

Bids Are invited for Annual Maintenance Service - Desktops, Laptops And Peripherals - As Per Tender Document; As Per Tender Document - Printer , Computers , Network Switch , Io Nodes , Ups , Ups , Manpower , Supply, Installation, Testing, And Commiss

Issued by Government Departments · Faridabad, Haryana
Tender Value
19.30 Lakhs
Estimated cost
Bid Submission
19 Aug 2026
4 days left
EMD
38619
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Faridabad → Haryana
EMD Exemption
Available
Quantity
1

Project Description

Bids Are invited for Annual Maintenance Service - Desktops, Laptops And Peripherals - As Per Tender Document; As Per Tender Document - Printer , Computers , Network Switch , Io Nodes , Ups , Ups , Manpower , Supply, Installation, Testing, And Commissioning Advance Maintenance Free Environment Friendly Chemical Earthing System Consisting Of Earth Pit Minimum Dia 150 Mm Size With 2/3Mtr Length, 50 Mm Dia Earth Electrode Molecular Bonded Copper On Outer Surface ( Minimum Copper Bonding Thickness 250 Microns) And Pre-Filled With Hygroscopic Powder With Terminals Connect Conductor And The Electrode Shall Be Surrounded By Suitable Powered From Beemoist(Backfilling Compound) Of Quantity Should Not Be Less Than 25 Kgs 2 Bags With Each Of Provided Maximum Contact Between The Electrode And Soil Sand With Complete Masonry Work. The Life Span For Chemical Earthing / Materials Should Be 10 Years. , Providing And Laying Earth Connections From Earth Electrode With Earth 8 Swg Dia Copper Wire In 15 Mm G.I Pipe (B Class) From Earth Electrode As Required & After Completion Of Earth Work, Earthing Parameter N-E Between 0.1 V To 2.0 V And As Per Direction Of Competent Authority. , Supply And Complete Installation Of Cat-6 Lan Cable Inside Pvc Conduit With Required Accessories (Including Saddle, Flexible Pipe, Tie, Band Etc.) Of Standard Oem And As Per The Direction Of Competent Authority. , Supply And Fixing Of Cat-6 Io Boxes With Cover For Lan (Gang Box, Faceplate & Io Port) Standard Oem.Numbering Tag On Each Io Box & Plastic Tag Strip On Each Cable And As Per The Direction Of Competent Authority. , Supply And Fixing Of Patch Panel -24 Port D-Link , Supply And Fixing Of Cat-6 Patch Chord 3 Meter Long , Supply And Fixing Of Cat-6 Patch Chord 1Mtr Long , Supply And Fixing Of 12U Data Rack-D-Link , Supply And Fixing Of Power Extension (6-Socket) Inside Rack , Supply, Fixing & Proper Configuration Of 24 Port Lan Edge Switch - Cisco Cbs350 24 Port With Poe & Sfp Port On Esic Network , Supply, Fixing & Proper Configuration Of 24 Port Lan Edge Switch - Cisco 3750 With Poe & Sfp Port On Esic Network , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface/Recessed Steel/ Pvc Conduit As Required. (Isi Marked) In Meter , 3 X 1.5 Sq. Mm , 3 X 2.5 Sq. Mm , 3 X 4 Sq. Mm , Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. (Isi Marked) In Meter , 25Mm , 32Mm , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. (Isi Marked) Each , 5/6 A Switch , 15/16 A Switch , 3 Pin 5/6 A Socket Outlet , 6 Pin 15/16 A Socket Outlet , Telephone Socket Outlet , Supplying And Fixing Following Size/ Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required. (Isi Marked) Each , 6 Modules (200 Mmx75 Mm) , 8 Modules (125 Mmx125 Mm) , 12 Modules (200 Mmx150 Mm) , Supplying And Fixing Following Modular Base & Cover Plate On Existing Modular Metal Boxes Etc. As Required. (Isi Marked) Each , 6 Modules , 8 Modules , 12 Modules , Supplying And Fixing 5 A To 32 A Rating, 240/415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. (Isi Marked) Each , Single Pole , Single Pole And Neutral , Double Pole , Triple Pole , Triple Pole And Neutral

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 12-Aug-2026 19-Aug-2026

BOQ

Sl. No. Item TitleItem Description
1PrinterPrinter
2ComputersComputers
3Network SwitchNetwork Switch
4IO NodesIO Nodes
5UPSUPS
6UPSUPS
7ManpowerManpower
8Supply, installation, testing, and commissioning advance maintenance free environment friendly chemical earthing system consisting of earth pit minimum dia 150 mm size with 2/3mtr length, 50 mm dia earth electrode molecular bonded copper on outer surface ( minimum copper bonding thickness 250 microns) and pre-filled with hygroscopic powder with terminals connect conductor and the electrode shall be surrounded by suitable powered from BEEMOIST(Backfilling Compound) of quantity should not be less than 25 kgs 2 bags with each of provided maximum contact Between the electrode and soil sand with complete masonry work. The life span for chemical earthing / materials should be 10 years.Supply, installation, testing, and commissioning advance maintenance free environment friendly chemical earthing system consisting of earth pit minimum dia 150 mm size with 2/3mtr length, 50 mm dia earth electrode molecular bonded copper on outer surface ( minimum copper bonding thickness 250 microns) and pre-filled with hygroscopic powder with terminals connect conductor and the electrode shall be surrounded by suitable powered from BEEMOIST(Backfilling Compound) of quantity should not be less than 25 kgs 2 bags with each of provided maximum contact Between the electrode and soil sand with complete masonry work. The life span for chemical earthing / materials should be 10 years.
9Providing and laying earth connections from earth electrode with earth 8 SWG dia copper wire in 15 mm G.I pipe (B class) from earth electrode as required & after completion of earth work, earthing parameter N-E between 0.1 V to 2.0 V and as per direction of competent authority.Providing and laying earth connections from earth electrode with earth 8 SWG dia copper wire in 15 mm G.I pipe (B class) from earth electrode as required & after completion of earth work, earthing parameter N-E between 0.1 V to 2.0 V and as per direction of competent authority.
10Supply and complete installation of CAT-6 LAN cable inside PVC conduit with required accessories (including saddle, flexible pipe, tie, band etc.) of standard OEM and as per the direction of competent authority.Supply and complete installation of CAT-6 LAN cable inside PVC conduit with required accessories (including saddle, flexible pipe, tie, band etc.) of standard OEM and as per the direction of competent authority.
11Supply and fixing of Cat-6 IO boxes with cover for LAN (Gang box, faceplate & IO port) standard OEM.Numbering tag on each IO box & plastic tag strip on each cable and as per the direction of competent authority.Supply and fixing of Cat-6 IO boxes with cover for LAN (Gang box, faceplate & IO port) standard OEM.Numbering tag on each IO box & plastic tag strip on each cable and as per the direction of competent authority.
12Supply and fixing of Patch Panel -24 port D-LinkSupply and fixing of Patch Panel -24 port D-Link
13Supply and fixing of Cat-6 Patch chord 3 meter longSupply and fixing of Cat-6 Patch chord 3 meter long
14Supply and fixing of Cat-6 Patch chord 1mtr longSupply and fixing of Cat-6 Patch chord 1mtr long
15Supply and fixing of 12U Data Rack-D-LinkSupply and fixing of 12U Data Rack-D-Link
16Supply and fixing of Power extension (6-Socket) inside rackSupply and fixing of Power extension (6-Socket) inside rack
17Supply, fixing & proper configuration of 24 Port LAN Edge Switch - Cisco CBS350 24 Port with PoE & SFP port on ESIC networkSupply, fixing & proper configuration of 24 Port LAN Edge Switch - Cisco CBS350 24 Port with PoE & SFP port on ESIC network
18Supply, fixing & proper configuration of 24 Port LAN Edge Switch - Cisco 3750 with PoE & SFP port on ESIC networkSupply, fixing & proper configuration of 24 Port LAN Edge Switch - Cisco 3750 with PoE & SFP port on ESIC network
19Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. (ISI marked) in meterSupplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. (ISI marked) in meter
203 x 1.5 sq. mm3 x 1.5 sq. mm
213 x 2.5 sq. mm3 x 2.5 sq. mm
223 x 4 sq. mm3 x 4 sq. mm
23Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (ISI marked) in meterSupplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (ISI marked) in meter
2425mm25mm
2532mm32mm
26Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (ISI marked) EachSupplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (ISI marked) Each
275/6 A switch5/6 A switch
2815/16 A switch15/16 A switch
293 pin 5/6 A socket outlet3 pin 5/6 A socket outlet
306 pin 15/16 A socket outlet6 pin 15/16 A socket outlet
31Telephone socket outletTelephone socket outlet
32Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. (ISI marked) EachSupplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. (ISI marked) Each
336 Modules (200 mmX75 mm)6 Modules (200 mmX75 mm)
348 Modules (125 mmX125 mm)8 Modules (125 mmX125 mm)
3512 Modules (200 mmX150 mm)12 Modules (200 mmX150 mm)
36Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. (ISI marked) EachSupplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. (ISI marked) Each
376 Modules6 Modules
388 Modules8 Modules
3912 Modules12 Modules
40Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (ISI marked) EachSupplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (ISI marked) Each
41Single poleSingle pole
42Single pole and neutralSingle pole and neutral
43Double poleDouble pole
44Triple poleTriple pole
45Triple pole and neutralTriple pole and neutral

AI Tender Summary

OUR REF NO 56774370
AUTHORITY Government Departments
TENDER VALUE 19.30 Lakhs
LAST DATE 19-08-2026
Authority
Authority Name Employees State Insurance Corporation
Work Description Bids Are invited for Annual Maintenance Service - Desktops, Laptops And Peripherals - As Per Tender Document; As Per Tender Document - Printer , Computers , Network Switch , Io Nodes , Ups , Ups , Manpower , Supply, Installation, Testing, And Commissioning Advance Maintenance Free Environment Friendly Chemical Earthing System Consisting Of Earth Pit Minimum Dia 150 Mm Size With 2/3Mtr Length, 50 Mm Dia Earth Electrode Molecular Bonded Copper On Outer Surface ( Minimum Copper Bonding Thickness 250 Microns) And Pre-Filled With Hygroscopic Powder With Terminals Connect Conductor And The Electrode Shall Be Surrounded By Suitable Powered From Beemoist(Backfilling Compound) Of Quantity Should Not Be Less Than 25 Kgs 2 Bags With Each Of Provided Maximum Contact Between The Electrode And Soil Sand With Complete Masonry Work. The Life Span For Chemical Earthing / Materials Should Be 10 Years. , Providing And Laying Earth Connections From Earth Electrode With Earth 8 Swg Dia Copper Wire In 15 Mm G.I Pipe (B Class) From Earth Electrode As Required & After Completion Of Earth Work, Earthing Parameter N-E Between 0.1 V To 2.0 V And As Per Direction Of Competent Authority. , Supply And Complete Installation Of Cat-6 Lan Cable Inside Pvc Conduit With Required Accessories (Including Saddle, Flexible Pipe, Tie, Band Etc.) Of Standard Oem And As Per The Direction Of Competent Authority. , Supply And Fixing Of Cat-6 Io Boxes With Cover For Lan (Gang Box, Faceplate & Io Port) Standard Oem.Numbering Tag On Each Io Box & Plastic Tag Strip On Each Cable And As Per The Direction Of Competent Authority. , Supply And Fixing Of Patch Panel -24 Port D-Link , Supply And Fixing Of Cat-6 Patch Chord 3 Meter Long , Supply And Fixing Of Cat-6 Patch Chord 1Mtr Long , Supply And Fixing Of 12U Data Rack-D-Link , Supply And Fixing Of Power Extension (6-Socket) Inside Rack , Supply, Fixing & Proper Configuration Of 24 Port Lan Edge Switch - Cisco Cbs350 24 Port With Poe & Sfp Port On Esic Network , Supply, Fixing & Proper Configuration Of 24 Port Lan Edge Switch - Cisco 3750 With Poe & Sfp Port On Esic Network , Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface/Recessed Steel/ Pvc Conduit As Required. (Isi Marked) In Meter , 3 X 1.5 Sq. Mm , 3 X 2.5 Sq. Mm , 3 X 4 Sq. Mm , Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. (Isi Marked) In Meter , 25Mm , 32Mm , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. (Isi Marked) Each , 5/6 A Switch , 15/16 A Switch , 3 Pin 5/6 A Socket Outlet , 6 Pin 15/16 A Socket Outlet , Telephone Socket Outlet , Supplying And Fixing Following Size/ Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required. (Isi Marked) Each , 6 Modules (200 Mmx75 Mm) , 8 Modules (125 Mmx125 Mm) , 12 Modules (200 Mmx150 Mm) , Supplying And Fixing Following Modular Base & Cover Plate On Existing Modular Metal Boxes Etc. As Required. (Isi Marked) Each , 6 Modules , 8 Modules , 12 Modules , Supplying And Fixing 5 A To 32 A Rating, 240/415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. (Isi Marked) Each , Single Pole , Single Pole And Neutral , Double Pole , Triple Pole , Triple Pole And Neutral
Basic Detail
Tender No GEM/2026/B/7783491
Bidding Type Tender
Location
City Faridabad
State Haryana
Key Dates
Publish Date 12 Aug 2026
Submission Date 19 Aug 2026
Open Date 19 Aug 2026
Finance
Tender Value 19.30 Lakhs
Tender Fee Ref. Documents
EMD 38619
Exemption Available
Document List
b530365e-39a9-490c-94d1-d99ae0b5c40f.pdf
1784197037.xlsx
1784197471.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 12, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 19, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 4 days
Aug 19, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Aug 19, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
pdf

b530365e-39a9-490c-94d1-d99ae0b5c40f.pdf

xlsx

1784197037.xlsx

pdf

1784197471.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders