Housing Urban and Rular Development Government Departments Closing in 6 days TDR #56772013

Tender For repair maintenance All E & M Services Installed At Dseu Maharani Bagh C Us, Meera Bai Institute Of Technology, New Delhi During Year 2026-27.

Issued by Government Departments · Delhi, Delhi
Tender Value
36.41 Lakhs
Estimated cost
Bid Submission
07 Aug 2026
6 days left
EMD
72831
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for repair maintenance All E & M Services Installed At Dseu Maharani Bagh C Us, Meera Bai Institute Of Technology, New Delhi During Year 2026-27.

BOQ

Name of Work:- RMO all E & M Services installed at DSEU Maharani Bagh C us, Meera Bai Institute of Technology, New Delhi during year 2026-27.
Sl. No. Item Description
1SH-I: Providing staff and EI Works etc Operation and Routine Maintenance of 1x500 KVA 11/0.440KV electric Sub Station comprising of HT Panel, LT panel APFC panles, transformers, electric driven water supply pump and operation of 01No. 180KVA DG Set with AMF panel round the clock on all days i/c Sunday & Holidays as required. a) E&M Operator -03 Nos. (one no. in each shift)b) Khallasi:-01 No. (In General shift)
2Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mmFRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
3a) Group C
4Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required.
5a) Group C
6Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
7a) 20 mm
8b) 25 mm
9Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface / recessed steel / PVC conduit as required.
10a) 3 x 1.5 sq.mm
11b) 3 x 4 sq.mm
12c) 3 x 6 sq.mm
13Supplying of following items to be used during day to day maintenance
14S.P. 5/6A one way Modular switch ISI marked.
15S.P. 15/16 A one way modular switch ISI marked.
163 Pin 5/6 A Modular Socket outlet ISI marked.
176 Pin 15/16A Modular Socket outlet ISI Marked.
18Bell Push modular type.
19Stepped type modular fan regulator(2 module)
203 pole MCCB, 100A, 16kA Ics=100% Icu and Operational Voltage 690V
213 pole MCCB, 200A, 25kA Ics=100% Icu and Operational Voltage 690V
224 pole MCCB,100A,30kA Ics=100% Icu and Operational Voltage 690V
234 pole MCCB, 200A, 36kA Ics=100% Icu andOperational Voltage 690V
246A, 32A, ratings, SP MCB, \\"C\\", curve, 10 KA braking capacity.
2563 A rating Double Pole isolator
26100A, 4 pole isolator
27Supply of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.a) 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
28Supplying of 300 mm sweep metallic heavy duty 900 rpm exhaust fan suitable for operation on 230V, 50 Hz single phase AC supply complete with louvers / shutters in the existing opening including making the hole to suit the size of the above fan making good the damage and connections etc. as reqd.
29Supplying of fresh air fan 200 mm sweep with shutter and louver in the existing opeining , including making the hole to suit the size of the above fan, making good the damage, connection, testing, commissioning etc. as required.
30Supplying 400mm sweep wall mounted cabin fan with speed regulator oscilatting type i/c testing & commsisioning suitable for 230volt 50Hz AC supply etc as reqd.
31Supplying of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder Coated CRCA Sheet Body (Thickness > 0.50 mm) a) 18-22watt
32Supplying of LED Recessed / surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim a) 18 watt
33Supplying of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K/ 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.) Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder Coated CRCA Sheet Body (Thickness > 0.50 mm) a) 36watt
34Supplying of Panel light 1x4 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K/ 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.) Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder Coated CRCA Sheet Body (Thickness >0.50 mm) a) 40watt
35Supplying of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -5 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection,EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirementdeg., suitable tilt able fitting, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy 105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).a) 70 Watt LED Flood light.
36100 Watt LED Flood light.
37Supplying of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). a) b) 90 Watt LED street light.
38Supplying & Laying of following sizes of XLPE insulated and PVC sheathed aluminium conductor armoured cable in pipe/HUME/Surface as reqd.
39a) 3 x 6 sqmm XLPE Al. Armoured cable
40b) 3 x 10 sqmm XLPE Al. Armoured cable
41c) 3.5 x 50 sqmm XLPE Al. Armoured cable
42Preventive and routine maintenance contract of 180 KVA DG Set i/e Engine, Alternator installed at Meera Bai Institute of Technology Maharani Bagh, Complete etc as reqd. (Labour charges and freight charges only)
43Supplying & Replacement of following parts with new one \\"B\\" check of 1 X180 KVA DG SET (Old materials shall be retained by the contractor) a) Filter Fuel - 01 b) Diesel Filter-01 No c) Gasket Cyl Head Cover-01 No d) Safety Element-01 No e) Primary Element-01 No f) Coolant Additive-10 Ltr- 01 No g) Lub Oil - 35 Ltr
44Supplying and replacement of following unservicable/damaged spare parts of 1 X 6CTA,180 KVA, DG Set (Old materials shall be retained by the contractor)
45a) Set of Hose
46b) Set of Hose Clip
47c) Flexible pipe
48Supply & replacement of 12V 180 AH Genset batteries including buyback of old batteries
49SH-III: Servicing and Maint. Of WTAC/STAC and Water Cooler Supply & Charging R-22/410/407/32/134a gas in the existing WTAC/STAC of 1.5/2.0 TR unit and water coolers i/c pressure testing, flushing the system and Gas Charging complete as reqd.
50Supplying & Fixing 25 mm diameter PVC heavy duty pipe for drainage in the existing split type AC unit with supporting clamps etc . complete as reqd.
51Supplying and fixing of Extra copper refrigerant piping of 5/8”, 3/8”, 1/4” i/c nitrile rubber insulation wrapping etc. complete as reqd.
52Providing and fixing of 3 core 2.5 sqmm PVC insulated and PVC sheathed bright annealed copper conductor cable for communication between indoor unit/outdoor unit/controllers inside building in existing steel/PVC Conduit/ surface/ existing channel, i/c making connection etc as reqd.
53Replacement of following capacity compressor in the existing WTAC/Split AC with new one and making copper pipe connection, brazing pressure testing and supplying and charging refrigerant gas i/c cutting the copper piping dismantling of the old compressor complete as Reqd.
54a) 1.5TR capacity
55b) 2.0TR capacity
56Replacement of upto 1 TR capacity compressor in the existing water cooler with new one and making copper pipe connection, brazing pressure testing and supplying and charging refrigerant gas i/c cutting the copper piping dismantling of the old compressor complete as Reqd.
57Supplying and replacement of wornout/defective copper condensor coil with new one in same size of design suitable for following capacity split type AC out door unit i/c breezing the all copper pipe with all distribution joints of make sure the connection with capiliary tube linking dryer duly proper etc pressure testing leak detection, vaccumizing the unit, gas charging etc complete as reqd.
58a) 1.5/2.0TR capacity
59Supplying and replacement of wornout/defective copper condensor coil with new one in same size of design suitable for following capacity window type AC i/c breezing the all copper pipe with all distribution joints of make sure the connection with capiliary tube linking dryer duly proper etc pressure testing leak detection, vaccumizing the unit, gas charging etc complete as reqd.
60a) 1.5TR capacity
61Supplying and replacement of wornout/defective copper cooling coil with new one in same size of design suitable for following capacity split type AC out door unit i/c breezing the all copper pipe with all distribution joints of make sure the connection with capiliary tube linking dryer duly proper etc pressure testing leak detection, vaccumizing the unit, gas charging etc complete as reqd.
62a) 1.5/2.0TR capacity
63Supplying and replacement of wornout/defective copper cooling coil with new one in same size of design suitable for following capacity window type AC i/c breezing the all copper pipe with all distribution joints of make sure the connection with capiliary tube linking dryer duly proper etc pressure testing leak detection, vaccumizing the unit, gas charging etc complete as reqd.
64a) 1.5TR capacity
65Replacement of non repairable inverter PCB in existing indoor/outdoor unit of STAC and WTAC complete etc as reqd.
66Replacement of non repairable non inverter PCB in existing indoor/outdoor unit of STAC and WTAC complete etc as reqd.
67Dismantling, shifting and reinstallating of existing 1.5TR/ 2.0TR capacity STAC (indoor and outdoor unit) including repairing the damaged caused due to dismantling within same office etc as required.
68Providing & replacement WTAC/STAC fan motor Capacity 1/4 to 1/8 hp including dismantling the burnt motor from the existing unit & fixing of new motor, making connections testing, commissioning etc.as reqd.
69Supplying and replacement of following defective spare parts in the existing AC unit with new one i/c connection testing etc. complete as required.
70a) Running capacitor - 36 Mfd/45 Mfd
71b) Starting capacitor- 80/100 Mfd
72Supply and fixing of 15/16Amp 3pin top plug including connection complete as reqd.
73Supplying and fixing stand for the outdoor unit of the STAC made of MS duly powder coated complete etc as required.
74Preventive maintenance & servicing of WTAC/STAC unit and water cooler i/c cleaning of water tank, attending day to day complaints from 9 AM to 5 PM and rectifying the defects, replacement of worn out parts such starting / running capacitor, starting relays, overload relays, thermostate, selector switches, sleeves, knobs, Front grills connectors, PCB etc. which required to be replaced during preventive maintenance & cleaning of filters, condenser fan, blower, fan/blower motor, Coils, Gas charging and any work related to AC/Water cooler is to be carried out as per instruction of Engineer-in-charge etc complete as required by deploying following staff:-(1) AC Mechanic :- 1 No. (9am to 5pm) For 03 Months for financial year 2026-27 & For 05 Months for financial year 2027-28
75Preventive Maintenance of 50 LPH and all type RO plants connected with/within water coolers i/c services (cleaning of all Filters), repair/ replacement of all electrical and electronic spare parts and replacement of consumables and non consumables items as when required like Pre Filter, Sediment Filter, Pre Carbon Filter and Post Carbon Filter alongwith membranes, pump and its accessories etc. as required. (Contractor has to pay minimum transportation charges Rs 100/- per visit to attend complaints for GB Pant College Campus. a) Per Visit for 8 hours RO Technician
76Supply & Replacement of RO TFC Membrane 75 GPD Eureka Forbes make i/c testing, commissioning etc. as required. (old dismantle shall be retained by the contractor.)
77Supply & Replacement of RO TFC Membrane 150 GPD Eureka Forbes make i/c testing, commissioning etc. as required, old dismantle shall be retained by the contractor. (old dismantle shall be retained by the contractor.)
78Supply and replacement of Particulate / Sediment/ Pre-Filter 10/20\\" Eureka Forbes make i/c Leak testing, commissioning etc complete as reqd at site. Dismantle shall be retained by the contractor.
79Supply and replacement of Pre /Post Carbon Filter 10/20\\" Eureka Forbes make i/c Leak testing, commissioning etc complete as reqd at site. (Dismantle shall be retained by the contractor.)
80Supply and Fixing of 20\\"x 2.5\\" Pre Filter bowl assly to prevent of excess silt in feed water to RO machines i/c Leak testing, commissioning etc complete as reqd at site. (old dismantle shall be retained by the contractor.)
81Supply and fixing of Automated Switching on/off device as per level of water in storage tank/ Water cooler etc as reqd. (old dismantle shall be retained by the contractor.)
82Suppy & Replacement of the defective spare Parts in existing Water PurificationSystem to make the machines operational i/c testing , commissioning etc. complete as reqd. (Old materials shall be retained by the contractor)
83SMPS 24/48V
84RO Pump 48V
85Solenoid Valve 24V
86Push type chrome Platted Brass Tap
87Providing and replacing of old defected/ rusted RO body parts with new one in existing Eureka Forbes RO Systems (old dismantle shall be retained by the contractor.)
88Supply and replacement of defective RO Body Spares Chassis of existing AG Reviva 50 LPH RO Water Purification system i/c testing &commissioning etc complete as reqd.
89Supply and replacement of defective RO Spare Mounting Tray of existing AG Reviva 50 LPH RO Water Purification system i/c testing &commissioning etc complete as reqd.
90Supply and replacement of defective Back Plate of existing AG Reviva 50 LPH RO Water Purification system i/c testing &commissioning etc complete as reqd.
91Supply and replacement of defective Top Cover of of existing AG Reviva 50 LPH RO Water Purification system i/c testing &commissioning etc complete as reqd.
92Supply and replacement of defective Wall mount Stand of existing AG Reviva 50 LPH RO Water Purification system i/c testing &commissioning etc complete as reqd.
93SH-IV: Comprehensive maintenance Lift Comprehensive maintenance of 1 No. 13 passengers (884 kgs) OTIS passenger lift complete with all the connected accessories, control panel, AC motor, Gear Box Fly wheels, Ropes, lift pit, guide rails counter weights, lambda mechanism and greasing / oiling the moving parts of the lift, cleaning & decarbonising all the electrical controls complete etc. as per terms & condition.
94Credit for dismantle materials
95Assorted Ceiling Fans
96Assorted Exhaust fans
97Assorted wall/PVC fresh air fan
98Assorted Switch /sockets/Regulators
99Assorted all type indoor fittings
100Assorted Flood light/street light fitting
101Assorted MCCB
102Assorted wire with insulation copper
103Assorted SP MCB
104Assorted compressor 1TR/1.5TR/ 2TR
105Assorted Refrigerant copper pipe
106Assorted 3 core 2.5sqmm wire with insulation
107Assorted cooling/condensor coil
108Assorted PCB
109Assorted Fan Motor
110Assorted Running/Starting capacitor
111Assorted Al. armoured Cable Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56772013
AUTHORITY Government Departments
TENDER VALUE 36.41 Lakhs
LAST DATE 07-08-2026
Authority
Authority Name Public Works Department
Work Description Tender for repair maintenance All E & M Services Installed At Dseu Maharani Bagh C Us, Meera Bai Institute Of Technology, New Delhi During Year 2026-27.
Basic Detail
Tender No 83/EE(E)/EMD South East/PWD/2026-27
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 31 Jul 2026
Submission Date 07 Aug 2026
Open Date 07 Aug 2026
Finance
Tender Value 36.41 Lakhs
Tender Fee Ref. Documents
EMD 72831
Exemption Not Available
Document List
a2438b3b-4632-4a5d-9462-7fbea20b3ae9.html
BOQ_394295.xls
tender.pdf
Tendernotice_1 (11).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 31, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 07, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Aug 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.