Tender For Maintenance Of Street Lights, High Masts, Subways, Underdeck & Fob Lights On Delhi Pwd Roads Under Sd-Iii, Pwd Emd South West. (Sh : Dismantling Of Existing Street Light Pole And Re-Installation I/C Laying Of Cable In Various Pwd Roads Und
Tender Overview
Project Description
Tender for Maintenance Of Street Lights, High Masts, Subways, Underdeck & Fob Lights On Delhi Pwd Roads Under Sd-Iii, Pwd Emd South West. (Sh : Dismantling Of Existing Street Light Pole And Re-Installation I/C Laying Of Cable In Various Pwd Roads Under Sub-Div. Iii Dhaula Kuan).
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling of Octagonal GI Pole of Various Height (8 to 12 mtr) with street light Fittings From existing foundation i/c cutting of foundation bolts etc. and making good smooth surface & Re-erection of these poles on new foundation with street light fittings by suitable means i/c testing, commissioning etc. as required. |
| 2 | Providing and laying in position 1:2:4 reinforced cement concrete foundation of size 850 mm.(L) X 850 mm. wide and 1500 mm. deep i/c excavation of earth, providing cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm. dia- 1660mm long (approx)- 8 Nos. and reinforcement ring of cold twisted bar of 8mm dia - 2800mm (approx) - 10nos. (with 150mm spacing) as required with positioning of foundation bolts (as per item below) and providing two nos. 90 mm. (O.D) DWC, HDPE Pipe for cable entry & exit as required (For 8-12 mtr Pole) |
| 3 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. |
| 4 | Upto 35 sq. mm |
| 5 | Above 35 sq. mm and upto 95 sq. mm |
| 6 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 7 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 8 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 9 | Supplying and fixing 4 Nos. 20 to 25mm dia X 750mm long GI foundation bolt (EN8 grade) with nuts, washer including 2 Nos. template of 4mm thick size 320mm x 320mm with 4 nos. 28mm dia holes, to match with PCD of Pole base plate as reqd. (For 8-12 mtr Pole) |
| 10 | Cutting of hard rock/road/ PCC/Paver Block for laying of UG cable for Street light pole to pole with the help of hilty/ hammer etc. i/c making good by laying in position cement concrete 1:2:4: (1 Cement :2 coars sand : 4 graded stone ) of size 0.2 B x 0.2 D mtr etc. as required. |
| 11 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 12 | Fabrication, Designing, Supplying & Fixing of Galvanized arm street light pole bracket (single/double/tripple over hang) with tightening bolt etc. (due to accident of poles) as per existing design of brackets of roads where the street light pole bracket to be fixed or as per approved by Engineer-In-Charge. (Similar type as per existing pole) |
| 13 | Supplying and fixing of terminal block suitable for16 to 25 sq.mm conductor -4 nos. & shorting links – 5nos. on DIN channel i/c providing and fixing DIN channel of suitable length – 2 nos. on the existing laminated sheet. Supplying and fixing 6 Amp, SPMCB, ‘C’ Characteristics Curve - 1/2 No. Earth stud - 1/2Nos. welded at suitable height two nos. washers, springs washers & nuts etc complete as required. |
| 14 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 15 | 3½ X 50 sq. mm (35mm |
| 16 | 4 X 25 sq. mm (28mm) |
| 17 | Supplying & fixing of pole window cover made of G.I of 3mm thickness with sleeve type arrangement on existing pole whose cover is missing i/c welding of sleeve around pole, providing and fixing allen bolt of suitable size as per direction of Engineer-in-charge. (Note: Sample must approved before installation at site). |
| 18 | Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 19 | 150 watt |
| 20 | 200 watt |
| 21 | Installation of Decorative LED Post Top fittings on the existing decorative pole & fixing with suitable size reducer as per dia of the pole i/c making connection testing, commissioning etc complete as required. |
| 22 | Dismantling of existing Feeder Pillar Panel along with accessories after disconnection the existing supply From existing foundation i/c cutting of angle iron frame etc. and making good smooth surface & Reinstallation the feeder pillar panel along with accessories and angle Iron frame on the new location (as decided by the Engineer in Charge) and making foundation of suitable size means Cement concrete 1:2:4 with centering, shuttering i/c testing, commissioning etc. as required. |
| 23 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 24 | SITC of 255 Amp Four Pole 2 No. + 2 NC Power Contactor in the existing panel i/c connection cable and thimbling etc complete as required. |
| 25 | SITC of 32 Amp Three Pole (ML-2 or equivalent) Power Contactor in the existing panel i/c connection cable and thimbling etc complete as required. |
| 26 | SITC of Digital Type Timer in the existing panel i/c connection cable and thimbling etc complete as required. |
| 27 | Providing & Fixing of following electrical accessories/switches etc in the above existing panel board including making connection testing, commissioning etc. complete as reqd. |
| 28 | 250 A,50KA,FPMCCB (Ics=Icu=100%) Incoming |
| 29 | 100 A,30KA,FPMCCB (Ics=Icu=100%) Outgoing Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender