Defence Statutory Bodies & Commissions/Committees Closing in 17 days TDR #56771852

Tender For Repair And Maintenance Of 11/.415Kv Damaged Cable And Electric Breakdown Including Fault Detection, Localization, Rectification Works In 11/.415Kv Underground Cable Network, Overhead Lines And Lt Panels At Map Naraina, Naraina Baugh, Mh Li

Issued by Statutory Bodies & Commissions/Committees · New Delhi, Delhi
Tender Value
49.50 Lakhs
Estimated cost
Bid Submission
21 Aug 2026
17 days left
EMD
99000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair And Maintenance Of 11/.415Kv Damaged Cable And Electric Breakdown Including Fault Detection, Localization, Rectification Works In 11/.415Kv Underground Cable Network, Overhead Lines And Lt Panels At Map Naraina, Naraina Baugh, Mh Line, Kv No-3, Naraina Pump House, Me Line, 5 Sikh Li Line & Md Accn, Dental Officers Mess, Oval Sub Stn, Cicg Sub Stn, Bor Sub Stn, Cod Depot Sub Stn No 1 To 3, Adp Sub Stn, Mcc Sub Stn, 505 Abw Sub Stn No 1 To 6, Cod Power House, Local Sub Stn, Map Kirby Place, Esd I & Ii, 226 Supply Depot, Shamshan Ghat Sub Stn, Fol Depot, Subraminiam Line And 1181 Pnr Coy, Kirby Grid To Subroto Park Ss/Rr Hosp Ss/ Sekhawati Grid In The Area Of Age (U) E/S - I, Under Ge (U) Elect Supply Deihi Cantt-10

BOQ

Name of Work:- REPAIR AND MAINTENANCE OF 11/.415KV DAMAGED CABLE AND ELECTRIC BREAKDOWN INCLUDING FAULT DETECTION, LOCALIZATION, RECTIFICATION WORKS IN 11/.415KV UNDERGROUND CABLE NETWORK, OVERHEAD LINES AND LT PANELS AT MAP NARAINA, NARAINA BAUGH, MH LINE, KV NO-3, NARAINA PUMP HOUSE, ME LINE, 5 SIKH LI LINE & MD ACCN, DENTAL OFFICERS MESS, OVAL SUB STN, CICG SUB STN, BOR SUB STN, COD DEPOT SUB STN NO 1 TO 3, ADP SUB STN, MCC SUB STN, 505 ABW SUB STN NO 1 TO 6, COD POWER HOUSE, LOCAL SUB STN, MAP KIRBY PLACE, ESD I & II, 226 SUPPLY DEPOT, SHAMSHAN GHAT SUB STN, FOL DEPOT, SUBRAMINIAM LINE AND 1181 PNR COY, KIRBY GRID TO SUBROTO PARK SS/RR HOSP SS/ SEKHAWATI GRID IN THE AREA OF AGE (U) E/S - I, UNDER GE (U) ELECT SUPPLY DEIHI CANTT-10
Sl. No. Item Description
1Testing the cables with high voltage DC testing machine and locating the fault in the cables by fault locating machine to pin point exact position of fault, disconnecting faulty 11 KV HT cables of different sizes from both ends, removal of Fault, Re-connections and testing of cables after removal of fault complete all as specified and directed by the Engr-in-Charge.Note: (a) 11 KV HT cable & joints shall be measured and paid for separately under respective items of schedule.(b) Retrieved old serviceable cable cover will be laid in trenches for cable protection. If extra PCC cover and sand required at site shall be measured and paid separately under respective items of BOQs.(c) Excavation and earth work will be measured and paid for separately under respective items of schedule.
2All as per item Ser No 1.00 here in before but 1100 Volt LT cables complete all as specified and directed by the Engr-in-Charge.
3M&L for disconnecting faulty /burnt end or portion of cable by removing the cable from loop including necessary excavation & earth work, suitable size of thimble LT tap, relaying and reconnecting the cable by removing faulty/burnt portion of cable and preparing fresh terminals for 25 Sqmm 3.5/4 core to 240 Sqmm 3.5 core of LT cable in LT Panel/pole/main switch etc complete all as specified and directed by the Engr-in-Charge.
4S&F of Cable jointing kit for 11 KV (Earthed) grade cable for Indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armored aluminum conductor cable incl testing and commissioning complete all as specified and directed by the Engr-in-Charge of following size :-
595 Sqmm 3 core.
6120 sqmm 3 core
7150 sqmm 3 core.
8185 Sqmm, 3 core.
9240 Sqmm 3 core.
10300 Sqmm 3 core
11S&F of Cable jointing kit for 11 KV (Earthed) grade cable for Outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armored aluminum conductor cable incl testing and commisioning complete all as specified and directed by the Engr-in-Charge of following size :-
1295 Sqmm 3 core.
13120 sqmm 3 core
14150 sqmm 3 core.
15185 Sqmm, 3 core.
16240 Sqmm 3 core.
17300 Sqmm 3 core
18S&F Cable jointing kit for 11 KV (Earthed) grade cable for Straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armored aluminum conductor cable incl testing and commissionig complete all as specified and directed by the Engg-in-Charge of following size :-
1995 Sqmm 3 core.
20120 sqmm 3 core
21150 sqmm 3 core.
22185 Sqmm, 3 core.
23240 Sqmm 3 core.
24300 Sqmm 3 core
25Supply, fixing and testing of Straight through joint heat shrinkable type with jointing kit suitable for cable PVC/XLPE insulated armored heavy duty aluminum conductor 1100 Volts grade complete all as specified and directed by the Engr-in-Charge for the following sizes:-
2616 -25 sqmm x 4 core
2735-50 sqmm x 3.5 core
2870-95 sqmm x 3.5 core
29120-150 Sqmm x 3.5 core
30185-240 Sqmm x 3.5 core
31300 Sqmm x 3.5 core
32400 sqmm x 3.5 Core
33M&L for excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft loose soil for laying / taking up/ taking down of cables and getting out and leveling of bottom surface to required level complete all as specified and directed by the Engr-in-Charge .
34M&L for returning filling in, including spreading, leveling, watering and well ramming soil in layers not exceeding 25 cm thick complete all as specified and directed by the Engr-in-Charge.
35M&L for removing excavated material (i.e. soil) from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point complete all as specified and directed by the Engr-in-Charge.
36M&L for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc, complete all as specified and directed by the Engr-in-Charge. Note : Measurement shall be taken after punning down.
37Supplying and laying of un-reinforced precast concrete cable cover, class HV, type 1, flat size 300mmx180mmx40mm complete all as specified and directed by the Engr-in-Charge.
38All as per srl item No 12.00 here-in-before but using old cable cover complete all as specified and directed by the Engg-in-Charge.
39S&F of sub class B bricks having minimum compressive strength 75Kg/Sqcm laid in trenches for cable protection etc complete all as specified and directed by the Engr-in-Charge.
40All as per srl item No 14.00 here-in-before but using old bricks complete all as specified and directed by the Engr-in-Charge.
41Supplying, laying, jointing, testing and connecting in replacement XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armored, electric power cable (heavy duty) with multistranded aluminum conductors, 11 KV grade, IS 7098 marked, suitable for HT 11 KV(E) system, laid in trenches / ducts / encased in GI pipe / fixed to pole, including jointing & testing complete all as specified and directed by the Engr-in-Charge of following sizes:-
4295 sqmm 3 core.
43120 sqmm 3 core.
44150 sqmm 3 core.
45185 sqmm 3 core
46240 sqmm 3 core
47300 sqmm 3 core
48Supply, laying, jointing, testing and commissioning in replacement LT underground cables 1100 volts grade, PVC insulated XLPE and PVC sheathed, heavy duty armored, with multistranded aluminum conductors, IS-1554 marked, laid in trenches complete all as specified and directed by the Engr-in-Charge of the following sizes:-Note :- Excavation, earth work, cable protection, sand fillings, cable joint shall be measured and paid separately.
4916 Sqmm 4 core
5025 Sqmm 4 core
5135 Sq mm 3.5 core.
5250 Sq mm 3.5 core.
5370 Sqmm 3.5 core
5495 Sqmm 3.5 core
55120 Sqmm 3.5 core
56150 Sqmm 3.5 core
57185 Sqmm 3.5 core
58240 Sqmm 3.5 core
59300 Sqmm 3.5 core
60M&L for boring of hole under road/pavement/hard standing or any other situation by manual means and suitable for passing of GI pipe 80 to 100 mm bore and making good both ends complete all as specified and directed by the Engr-in-Charge.
61S&F in replacement GI Pipe (light grade) with necessary accessories/ fittings for cable protections/pole or for crossing of culverts/nallah etc complete all as specified and directed by the Engr-in-Charge of following bore sizes:-
6240 mm
6350 mm
6480 mm
65100 mm .
66M&L for cutting and removing grass, vegetation bushes etc from surrounding 4 pole/6 pole, Transformer, LT panels, in and outside area of HT/LT Sub stn and removing all rubbish to a distance not exceeding 50 m complete all as specified and directed by the Engr-in-Charge.
67M&L for testing, setting & co-ordination of relay parameters consideration with incoming and outgoing feeders including following tests and setting complete all as specified and directed by the Engr-in-Charge as per detalis mentioned as under :- (i) testing of following relays of control panel with secondary injection kit checking and programming of realy (ii) OVER CURRENT IDMT with pick upsetting ,TMS ,CTR >,Td,I>>>,Td setting(iv) Earth fault DMT IDMT with pick up setting ,TMS,CTR fault current operating time setting(v) Earth fault DMT with I>>,Td,I>>>,Td setting
68M&L for re-painting of existing transformer/RMU GI fencing of any sizes by applying 2 coats of aluminum paint including rubbing with wire brush/sand paper to fencing/angle irons, at different location after disconnecting of HT supply from incoming and LT supply complete all as specified and directed by the Engr-in-Charge.
69M&L for fixing of LT Panel door having thickness 3.15 of existing panels complete with locking arrangement, welding of door using hinges, and painting after fixing complete all as directed and specified by Engr-in-Charge.
70M&L for Decarbunizing/cleaning complete outgoing/Incoming LT Air Circuit Breaker circuit of size 800/1000/1200 Amps, srpring, arcing surfaces, 3 phase, cleaning with CTC and ensure proper decarburizing, re-fixing the same tightening the nuts, bolts thimbles for incoming and outgoing system complete all as specified and directed by the Engr-in-Charge, the rate quoted is inclusive of spring & cotton waste to be provided by contractor.
71Note : Contractor should procure and provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Engr-in-charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56771852
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 49.50 Lakhs
LAST DATE 21-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair And Maintenance Of 11/.415Kv Damaged Cable And Electric Breakdown Including Fault Detection, Localization, Rectification Works In 11/.415Kv Underground Cable Network, Overhead Lines And Lt Panels At Map Naraina, Naraina Baugh, Mh Line, Kv No-3, Naraina Pump House, Me Line, 5 Sikh Li Line & Md Accn, Dental Officers Mess, Oval Sub Stn, Cicg Sub Stn, Bor Sub Stn, Cod Depot Sub Stn No 1 To 3, Adp Sub Stn, Mcc Sub Stn, 505 Abw Sub Stn No 1 To 6, Cod Power House, Local Sub Stn, Map Kirby Place, Esd I & Ii, 226 Supply Depot, Shamshan Ghat Sub Stn, Fol Depot, Subraminiam Line And 1181 Pnr Coy, Kirby Grid To Subroto Park Ss/Rr Hosp Ss/ Sekhawati Grid In The Area Of Age (U) E/S - I, Under Ge (U) Elect Supply Deihi Cantt-10
Basic Detail
Tender No GE ELECT/TOKEN-28/2026-2027
Bidding Type Tender
Location
City New Delhi
State Delhi
Key Dates
Publish Date 31 Jul 2026
Submission Date 21 Aug 2026
Open Date 24 Aug 2026
Finance
Tender Value 49.50 Lakhs
Tender Fee 500
EMD 99000
Exemption Not Available
Document List
5e69b37c-6082-468c-b1f2-c2205d376f45.html
BOQ_876167.xls
TD28.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 31, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 17 days
Aug 24, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 20 days

Tender Documents

Download All (ZIP) ↓
html

5e69b37c-6082-468c-b1f2-c2205d376f45.html

xls

BOQ_876167.xls

pdf

TD28.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail