Educational and Research Institute Boards / Undertakings / PSU Closing in 13 days TDR #56771635

Tender For Civil, S&P And Electrical Repair, Renovation,Modification And Refurbishing Work At Vice Chancellors Residence At Railghumti, Cooch Behar Under Uttar Banga Krishi Viswavidyalaya, Pundibari,Cooch Behar. [Composite Work].

Issued by Boards / Undertakings / PSU · Coochbehar, West Bengal
Tender Value
15.01 Lakhs
Estimated cost
Bid Submission
14 Aug 2026
13 days left
EMD
30022
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Coochbehar → West Bengal
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Civil, S&P And Electrical Repair, Renovation,Modification And Refurbishing Work At Vice Chancellors Residence At Railghumti, Cooch Behar Under Uttar Banga Krishi Viswavidyalaya, Pundibari,Cooch Behar. [Composite Work].

BOQ

Name of Work:- Civil, S&P and Electrical Repair, Renovation,Modification and Refurbishing work at Vice Chancellors Residence at Railghumti, Cooch Behar under Uttar Banga Krishi Viswavidyalaya, Pundibari,Cooch Behar. [Composite work].
Sl. No. Item Description
1Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars. (a) In ground floor including roof.
2Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor including removing rubbish within a lead of 75m as directed.
3Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course,scaffolding / staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (i) With 1:6 cement mortar. (b) 15 mm thick plaster
4Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick)
5Brick work with 1st class bricks in cement mortar (1:6)b) In Super Structure,Ground floor.
6Applying 2 coats of bonding agent with synthetic multi functional rubber emulsion having adhesive and water proofing properties by mixing with water in proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturer's specification [Cement to be supplied by the Department]
7Removing old scales, blisters etc. of interior surface of walls,ceiling by scraping etc. and preparing smooth and even surface with rendering or cement mortar (1:2) (as necessary), to make the surface suitable for receiving distemper.
8Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (a) One Coat. i) Water based interior grade Acrylic Primer
9Applying Acrylic Emulsion Paint of approved make and brand on wallsand ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) :ii) Luxury Quality
10Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary. (a) On timber or plastered surface :With super gloss (hi-gloss) -(iv) Two coats (with any shade except white)
11Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary. (b) On steel or other metal surface ::With super gloss (hi-gloss) -(iv) Two coats (with any shade except white)
12Supplying, fitting & fixing best quality digital printed Ceramic tiles in coloured decorative on walls and floors to match with the existing work & 4 nos. key stones (10mm) fixed with adhesive 4.5 mm thick at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. With polymerised adhesive and epoxy grout pointing including spacer - 2mm (When tiles are laid over existing hard ready surface) all complete as per direction of Engineer-in-charge.
13Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry back side of tiles using cement @ 2.91Kg./sqM or using polymerised adhesive (6 mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per sqM below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles / epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and p manufacturer's specification and direction of Engineer-in-Charge.(B) Light Colour
14Providing and fixing of false ceiling with powder coated exposed G.I. grid suspension system (E-Grid U-1520 or equivalent load carrying capacity with mid span deflection not exceeding 1/360 span with hanger spacing of 1200mm c/c ) consisting of Main Runner 3600 mm long, Cross Tee 1200 mm / 600 mm long and Wall Angle. The Wall Angle shall be fixed on PVC Dash Fasteners on the perimeter of the wall by steel screws with distance 300mm c/c. The Main Runners to be placed @ 1200 megular interval of 600 mm to form a modular grid of 1200mm X 600mm. Additional Cross Tees of 600 mm shall be placedperpendicular to the Cross Tee 1200 mm long to finally form a grid of 600 mm X 600 mm. Grid of module size 600 mm X 600 mm shall be supported by 6 mm dia G.I. wire from purlins / soffit. 15mm thick OW Acoustic Board (Mineral Fiber Acoustic Ceiling Tiles) of approved patern and size 595mm X 595mm with NRC value > 0.65 should be placed in the Grid module to form a False Ceiling. All complete as per the drawing & directions of Engineer-in-charge. In ground floor.
15Supplying, fitting and fixing boiling water resistant ply conforming to IS: 303- 1989 bonded with phenol formaldehyde synthetic resin of approved make and brand fitted and fixed as per design as per approval and direction of Engineer-in- Charge.[excluding the cost of supporting frame work and teak wood batten/Lipping] In Ground Floor. (vi) 19mm
16Supplying, fitting and fixing boiling water resistant ply conforming to IS: 303- 1989 bonded with phenol formaldehyde synthetic resin of approved make and brand fitted and fixed as per design as per approval and direction of Engineer-in- Charge.[excluding the cost of supporting frame work and teak wood batten/Lipping] In Ground Floor. (ii) 6mm
17Supplying fitting, fixing decorative lamination conforming to IS: 2046 : 1995 as per approved make, brand, finish and thickness with fitting, fixing the same on Particle/MDF / Ply Boards with recommended / approved adhesive with proper clipping the sides for better attachment as per direction of Engineer-incharge. The rate includes the cost of labour, adhesive and all incidental charges thereof. In ground floor. (ii) Thickness of laminate 1 mm
18Supplying fitting, fixing 7 to 8 mm thick pvc wall panelling including supporting frame work in wall as per direction of Engineer-In Charge
19Anodised aluminium butt hinges of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 205/66) and fitted and fixed with cadmium plated screws:(iv) 75 x 63 x 3.2mm.
20Anodised aluminium Aldrop / Sliding bolts of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 2681/66) fitted and fixed complete. (i) 250mm x 16mm dia bolt.
21Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete: (vii) 150 mm grip x 12 mm dia rod.
22Supplying,fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charges for fitting & fixing of aluminium 2-track/3-track sliding window with fixing of glass
23Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (c) Sal : Siliguri.
24Panel shutters of door and window, as per design (each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings. In ground floor.(a) Ordinary Teak Wood.
25Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor..(b) 32 mm thick shutters (single leaf)
26Scraping of moss, blisters etc.thoroughly from exterior surface of walls necessitating the use of scraper, wire brush etc.(Payment against this item will be made only when this has been done on the specific direction of the Engineer-in-charge)
27Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor including removing rubbish within a lead of 75m as directed.
28Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course,scaffolding / staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (i) With 1:6 cement mortar. (b) 15 mm thick plaster
29Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick)
30Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC.(b) Two Coats
31Protective and Decorative Textured exterior high class matt finish paint of approved quality, composed of special Tharmoplastic Resin containing fine crystalline additives derive from Granite as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. In Ground floor. Two Coat
32Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary. (b) On steel or other metal surface ::With super gloss (hi-gloss) -(iv) Two coats (with any shade except white)
33Brick work with 1st class bricks in cement mortar (1:6)b) In Super Structure,Ground floor.
34125 mm. thick brick work with 1st class bricks in cement mortar (1:4) inground floor.
35Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn) coating of 150 grams per sq. metre (followed by colour coated on both side) steel sheet work having minimum yield strength of 550 Mpa of trapizoidal profile of approved make (excluding the supporting frame work) fitted and fixed with 55 mm & 25 mm self tapping screw, EPDM Washer 16 mm dia & 3 mm th. washer etc. complete with 150 mm end lap and one corrugation minimum side lap. (Payment to be made on area of finished work).(i) In Roof:- a) With 0.5 mm thick sheet
36Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes.(b) River bazree
37Scraping of moss, blisters etc.thoroughly from exterior surface of walls necessitating the use of scraper, wire brush etc.(Payment against this item will be made only when this has been done on the specific direction of the Engineer-in-charge)
38Colour washing with any shade with Stainers, as required includingcleaning and smoothening surface thoroughly :(ii) External surface (Ground floor)(b) Two coats(i) Other than yellow, pink.
39(a) Supplying, fitting galvanised 3 ply 12 gauge / 4 points line of barbed wire in fencing (holes already made in the body of the post) or fixed by staples tightening and fixing the wires in taut condition
40Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete. A) UPVC Pipes: (i) 75 mm. Dia.
41Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement conc (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials. With 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and1.00m inside dia. (Other than SAIL/TATA/RINL)
42Supplying, fitting and fixing E.W.C. in white glazed vitreous chinaware of approved make complete in position with necessary bolts, nuts etc(a) With 'P' trap.
43Supplying, fitting and fixing Closet seat of approved make with lid and C.P. hinges, rubber buffer and brass screws complete.(a) E.W.C.(ii) Plastic (hallow type) white
44Supplying, fitting and fixing soap holder.(a) PTMT (Prayag or equivalent)
45Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992(ii) Double Socketed 3 Meter Length (a) 75 mm
46Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to AST MD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) (a) For Exposed Work PVC Pipes. 25 mm
47Supplying, fitting and fixing bib cock or stop cock.(a) (i) Chromium plated Bib Cock short body (Equivalent to Code No. 511 & Model - Tropical / Sumthing Special of ESSCO or similar brand).
48b) (i) Chromium plated Stop Cock (Equivalent to Code No. 513(A) & 513(B) & Model - Tropical / Sumthing Special of ESSCO or similar
49Supplying, fitting and fixing 10 litre porcelain low-down cistern of approved make with either side or bottom inlet, side overflow, brackets complete with all internnal PVC fittings. White
50Distribution wiring in 1.1 KV, 3x1.5 sq.mm. single core stranded 'FR' PVC insulated & unsheathed copper wire (Finolex, Havell’s) in19 mm bore, 3 mm thick polythene pipe complete with all accessories embedded in wall to LED surface mounted light /fan / ex-haust fan points with Modular type switch ( Legrand) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages . Average length- 8mtr.
51Distribution wiring in 3x1.5 sq.mm. single core stranded 'FR' PVC insulated & unsheathed copper wire (Finolex, Havell’s, RR cable ) in 19 mm bore, 3 mm thick polythene pipe complete with all accessories embedded in wall to 240 V, 6A 3/5 pin plug point incl. S& F 240 V, 6A , 3/5 pin Modular type Socket & switch ( Legrand ) fixed on Modular GI switch board incl. earth continuity wire with Modular top cover plate flushed in wall incl. mending good damages to original finish. On board socket.
52Fixing of 6/18 watt LED Panel/surface mounted light fittings on wall/ceiling by screws etc. .
53S & F. 240V, 2 Modular socket type fan regulator (Step type) (Crabtree) on existing Modular GI switch board with top cover plate incl. making necy. connections etc.
54Fixing of 240 volt, 1200 mm sweep ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 3x1.5 sq.mm. flexible copper wire.
55Supply & Fixing 240 V, 2x6 A, 3 pin Modular type plug socket (Legrand ) with 6A Modular type switch, without plug top on GI / PVC Modular type switch board with Modular top cover plate on wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
56Supply & Fixing 240 V, 6/16 A, 3/5 pin Modular type plug socket (Legrand) with 16A Modular type switch, without plug top on GI Modular type switch board with top cover plate on wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
57Supply & fixing of 2 nos. 240 volt, 6 amp. Modular plug socket with 2 nos, 6 A modular switch & 1 no. 240 volt, 16 amp. Modular plug socket with switch in a single modular PVC/GI switch board ( Legrand) with top cover plate on wall incl. making necy. connections with PVC Cu wire and earth continuity wire etc.
58Supplying and fixing double door 4 way Vertical TPN MCB DB for 415 volt, 160amp. MCCB enclosure incomer with IP-42/43 protection, embeded on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Legrand).
59Supplying and fixing 415 V, 125 amp, Four Pole MCCB of Breaking capacity 25kA /35kA with fixed thermal and fixed magnetic / adjus- table thermal and fixed magnetic setting in exis ting DBs / enclosure and necessary connection (Legrand).
60Supplying and fixing 415 V, 63 A, TP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary con nection (Legrand).
61Supplying and fixing 63 amp,6 way double door HTPN MCB DB with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment and painting for AC, SPNDB,single phase power point. (Make- Legrand )
62Supplying and fixing 415 V 63 A, 4 pole MCB on din rail of existing DBs and necessary connection.( Legrand)
63S & F. 10-32 amp, 240V SPN MCB, ‘C’ curve on din rail of existing PDB & DB and necy. connection (Legrand). For HTPN MCB DB. & SPN MCB DB
64Supplying and fixing double-door (2+8) SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.(Legrand)
65S & F. 240 volt, 40 amp. DP MCB on din rail of existing DB and necessary connection ( Legrand).
66S & F. 10-16 amp, 240V SPN MCB, ‘C’ curve on din rail of existing PDB & DB and necy. connection (Legrand). For HTPN MCB DB. & SPN MCB DB
67S and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Finolex, Havell’s,RRcable) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required.a) 3x1.5 sq.mm for Switch board , 6 amp plug socketand .
68b) 2x 2.5 +1x1.5 Sq mm Geyser and power point
69c) 2x 4.0 +1x2.5 Sq mm for A.C.
70c) 2x 6.0 +1x4 Sq mm for HTPN MCB DB to SPN MCB DB
71Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket with 2 Module GI Modular type switch board with 2 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
72Supply & Fixing 240 V, 25 A, Modular type starter (Make- Legrand) with 25A Modular switch type DP MCB ('C' Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc
73Laying of 3.5 core 25 sqmm cables after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth75 mm in floor/pavement/wall etc. and mending good the damages to original finish incl. removing the rubbish.
74Laying of 3.5 core 50 sqmm cables after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth75 mm in floor/pavement/wall etc. and mending good the damages to original finish incl. removing the rubbish.
75S&F of 3.5 core 25 Sq. mm compression type gland complete for following XLPE/PVC armoured cables.
76S&F of 3.5 core 50 Sq. mm compression type gland complete for following XLPE/PVC armoured cables.
77Finishing the end of 3.5 core 25 Sq. mm XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials.
78Finishing the end of 3.5 core 50 Sq. mm XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials.
79Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 40 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required.
80Supply and fixing 240 volt AC/DC superior type multitune (min 10 nos tune) Call bell (Anchor or equivalent) with selector switch for single/Multi Tunes mode Batter operated on HW/PVC/ Bakelite board including S&F board and battery as required.
81Supplying and fixing 2 way 240 volt MCB SS enclosure with IP-20/30 protection, powder coated MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment. Make- Legrand.
82S & F. 240 volt, 20 amp. DP MCB on din rail of existing DB and necessary connection ( Legrand). For out door light fittings
83Earthing with 80 mm dia. ISI medium GI pipe( TATA MEDIUM) 3.64 mm thick x6 mts. long and 1 no 65 mm x 6 mm x 8 mm galvanized ( hot Dip) steel dtrip ( 4 mtr long) 20 mm dia x 125 mm long galvanized bolt, double nut bolt s double washers including finishing both ends by making holes etc and supply and 80 mm dia GI pipe protection ( 6 mtr long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 7.3 mtr. ***Earth resistance should be below 1 ohm.
84Supply and fixing of 415 volt 100 amp TPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc innc. S & F 3 nos. DIN type HRC as same rating . Make- L & T . Front handle
85Connecting the equipments to earth busbar including S & F. 8 SWG copper solid wire on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages.Earth wire should be connected earth pit to all bushbar and earth bus bar to HTPN MCB DB & SPN MCB DB .
86Connecting the equipments to earth busbar including S & F. 10 SWG copper solid wire on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages.Earth wire should be connected earth pit to all bushbar and earth bus bar to HTPN MCB DB & SPN MCB DB .
87Supply of XLPE/ PVC Armoured Aluminium cable (GLOSTER, CRYSTOL, Havells). 1.1 kv grade, 3.5 core ,25 sq mm XLPE/PVC armoured aluminium cable,
88Supply of XLPE/ PVC Armoured Aluminium cable (GLOSTER, CRYSTOL, Havells). 1.1 kv grade, 3.5 core ,50 sq mm XLPE/PVC armoured aluminium cable,
89Supply of 230volt, 1200 mm sweep , AC ceiling Fan ( Orient - Summer King, SummerCool, Summer Breeze,)
90Supply and fixing of 240 volt 250 mm modular PVC Exhaust fan , Make Havells - FHVVEDXOWH10 Ventil Air Dx.
91Supply of 240 volt, 20 watt LED surface mounted light fittings Make- Philips, Model- SM251C LED20S- 6500 PSU WH. OR MAKE - Havells, Model - INTEGRANXTRDDLRSURD24WLED840S
92Supply of 240 volt, 20 watt LED recessed panel light fittings Make- Philips, Model- DN296B LED20S-6500 PSE WH S2
93Supply of 240 volt, 6 watt LED surface mounted light fittings Make- Philips, Model- SM250C LED7S- 6500 PSU WH. OR MAKE - Havells,
94Desmaintaling of existing electrification of proposed existing V.C. Bunglow and desmaintaling materials should be deposit to University store as per instruction of AE (El)
95Supply, installation, testing and commissioning including supply and fixing of supporting bracket for out side unit of 2.0 ton ,3 star Split inverter AC incliding supply and fixing of mounting bracket . Make- Voltas, Model - 183 V CAZS.or equivalent Blue Star, HITACHI.[74990+1500+1500 =77990.00]
96Add GST @18.00% from S.L. No- 01 to 95
97Add Cess @1.00% from S.L. No- 01 to 95 Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56771635
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 15.01 Lakhs
LAST DATE 14-08-2026
Authority
Authority Name Uttar Banga Krishi Viswavidyalaya
Work Description Tender for Civil, S&P And Electrical Repair, Renovation,Modification And Refurbishing Work At Vice Chancellors Residence At Railghumti, Cooch Behar Under Uttar Banga Krishi Viswavidyalaya, Pundibari,Cooch Behar. [Composite Work].
Basic Detail
Tender No NIeT-01 of 2026-27
Bidding Type Tender
Location
City Coochbehar
State West Bengal
Key Dates
Publish Date 31 Jul 2026
Submission Date 14 Aug 2026
Open Date 17 Aug 2026
Finance
Tender Value 15.01 Lakhs
Tender Fee 1000
EMD 30022
Exemption Available
Document List
67a03396-9b73-4f22-9064-d2233e1251ce.html
BOQ_2543162.xls
Tendernotice_1 (16).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 31, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 14, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 13 days
Aug 17, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 16 days

Tender Documents

Download All (ZIP) ↓
html

67a03396-9b73-4f22-9064-d2233e1251ce.html

xls

BOQ_2543162.xls

pdf

Tendernotice_1 (16).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders