Tender For Civil, S&P And Electrical Repair, Renovation,Modification And Refurbishing Work At Vice Chancellors Residence At Railghumti, Cooch Behar Under Uttar Banga Krishi Viswavidyalaya, Pundibari,Cooch Behar. [Composite Work].
Tender Overview
Project Description
Tender for Civil, S&P And Electrical Repair, Renovation,Modification And Refurbishing Work At Vice Chancellors Residence At Railghumti, Cooch Behar Under Uttar Banga Krishi Viswavidyalaya, Pundibari,Cooch Behar. [Composite Work].
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars. (a) In ground floor including roof. |
| 2 | Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor including removing rubbish within a lead of 75m as directed. |
| 3 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course,scaffolding / staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (i) With 1:6 cement mortar. (b) 15 mm thick plaster |
| 4 | Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick) |
| 5 | Brick work with 1st class bricks in cement mortar (1:6)b) In Super Structure,Ground floor. |
| 6 | Applying 2 coats of bonding agent with synthetic multi functional rubber emulsion having adhesive and water proofing properties by mixing with water in proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturer's specification [Cement to be supplied by the Department] |
| 7 | Removing old scales, blisters etc. of interior surface of walls,ceiling by scraping etc. and preparing smooth and even surface with rendering or cement mortar (1:2) (as necessary), to make the surface suitable for receiving distemper. |
| 8 | Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (a) One Coat. i) Water based interior grade Acrylic Primer |
| 9 | Applying Acrylic Emulsion Paint of approved make and brand on wallsand ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) :ii) Luxury Quality |
| 10 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary. (a) On timber or plastered surface :With super gloss (hi-gloss) -(iv) Two coats (with any shade except white) |
| 11 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary. (b) On steel or other metal surface ::With super gloss (hi-gloss) -(iv) Two coats (with any shade except white) |
| 12 | Supplying, fitting & fixing best quality digital printed Ceramic tiles in coloured decorative on walls and floors to match with the existing work & 4 nos. key stones (10mm) fixed with adhesive 4.5 mm thick at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. With polymerised adhesive and epoxy grout pointing including spacer - 2mm (When tiles are laid over existing hard ready surface) all complete as per direction of Engineer-in-charge. |
| 13 | Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry back side of tiles using cement @ 2.91Kg./sqM or using polymerised adhesive (6 mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per sqM below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles / epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and p manufacturer's specification and direction of Engineer-in-Charge.(B) Light Colour |
| 14 | Providing and fixing of false ceiling with powder coated exposed G.I. grid suspension system (E-Grid U-1520 or equivalent load carrying capacity with mid span deflection not exceeding 1/360 span with hanger spacing of 1200mm c/c ) consisting of Main Runner 3600 mm long, Cross Tee 1200 mm / 600 mm long and Wall Angle. The Wall Angle shall be fixed on PVC Dash Fasteners on the perimeter of the wall by steel screws with distance 300mm c/c. The Main Runners to be placed @ 1200 megular interval of 600 mm to form a modular grid of 1200mm X 600mm. Additional Cross Tees of 600 mm shall be placedperpendicular to the Cross Tee 1200 mm long to finally form a grid of 600 mm X 600 mm. Grid of module size 600 mm X 600 mm shall be supported by 6 mm dia G.I. wire from purlins / soffit. 15mm thick OW Acoustic Board (Mineral Fiber Acoustic Ceiling Tiles) of approved patern and size 595mm X 595mm with NRC value > 0.65 should be placed in the Grid module to form a False Ceiling. All complete as per the drawing & directions of Engineer-in-charge. In ground floor. |
| 15 | Supplying, fitting and fixing boiling water resistant ply conforming to IS: 303- 1989 bonded with phenol formaldehyde synthetic resin of approved make and brand fitted and fixed as per design as per approval and direction of Engineer-in- Charge.[excluding the cost of supporting frame work and teak wood batten/Lipping] In Ground Floor. (vi) 19mm |
| 16 | Supplying, fitting and fixing boiling water resistant ply conforming to IS: 303- 1989 bonded with phenol formaldehyde synthetic resin of approved make and brand fitted and fixed as per design as per approval and direction of Engineer-in- Charge.[excluding the cost of supporting frame work and teak wood batten/Lipping] In Ground Floor. (ii) 6mm |
| 17 | Supplying fitting, fixing decorative lamination conforming to IS: 2046 : 1995 as per approved make, brand, finish and thickness with fitting, fixing the same on Particle/MDF / Ply Boards with recommended / approved adhesive with proper clipping the sides for better attachment as per direction of Engineer-incharge. The rate includes the cost of labour, adhesive and all incidental charges thereof. In ground floor. (ii) Thickness of laminate 1 mm |
| 18 | Supplying fitting, fixing 7 to 8 mm thick pvc wall panelling including supporting frame work in wall as per direction of Engineer-In Charge |
| 19 | Anodised aluminium butt hinges of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 205/66) and fitted and fixed with cadmium plated screws:(iv) 75 x 63 x 3.2mm. |
| 20 | Anodised aluminium Aldrop / Sliding bolts of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 2681/66) fitted and fixed complete. (i) 250mm x 16mm dia bolt. |
| 21 | Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete: (vii) 150 mm grip x 12 mm dia rod. |
| 22 | Supplying,fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charges for fitting & fixing of aluminium 2-track/3-track sliding window with fixing of glass |
| 23 | Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (c) Sal : Siliguri. |
| 24 | Panel shutters of door and window, as per design (each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings. In ground floor.(a) Ordinary Teak Wood. |
| 25 | Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor..(b) 32 mm thick shutters (single leaf) |
| 26 | Scraping of moss, blisters etc.thoroughly from exterior surface of walls necessitating the use of scraper, wire brush etc.(Payment against this item will be made only when this has been done on the specific direction of the Engineer-in-charge) |
| 27 | Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor including removing rubbish within a lead of 75m as directed. |
| 28 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course,scaffolding / staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (i) With 1:6 cement mortar. (b) 15 mm thick plaster |
| 29 | Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick) |
| 30 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC.(b) Two Coats |
| 31 | Protective and Decorative Textured exterior high class matt finish paint of approved quality, composed of special Tharmoplastic Resin containing fine crystalline additives derive from Granite as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. In Ground floor. Two Coat |
| 32 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary. (b) On steel or other metal surface ::With super gloss (hi-gloss) -(iv) Two coats (with any shade except white) |
| 33 | Brick work with 1st class bricks in cement mortar (1:6)b) In Super Structure,Ground floor. |
| 34 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:4) inground floor. |
| 35 | Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn) coating of 150 grams per sq. metre (followed by colour coated on both side) steel sheet work having minimum yield strength of 550 Mpa of trapizoidal profile of approved make (excluding the supporting frame work) fitted and fixed with 55 mm & 25 mm self tapping screw, EPDM Washer 16 mm dia & 3 mm th. washer etc. complete with 150 mm end lap and one corrugation minimum side lap. (Payment to be made on area of finished work).(i) In Roof:- a) With 0.5 mm thick sheet |
| 36 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes.(b) River bazree |
| 37 | Scraping of moss, blisters etc.thoroughly from exterior surface of walls necessitating the use of scraper, wire brush etc.(Payment against this item will be made only when this has been done on the specific direction of the Engineer-in-charge) |
| 38 | Colour washing with any shade with Stainers, as required includingcleaning and smoothening surface thoroughly :(ii) External surface (Ground floor)(b) Two coats(i) Other than yellow, pink. |
| 39 | (a) Supplying, fitting galvanised 3 ply 12 gauge / 4 points line of barbed wire in fencing (holes already made in the body of the post) or fixed by staples tightening and fixing the wires in taut condition |
| 40 | Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete. A) UPVC Pipes: (i) 75 mm. Dia. |
| 41 | Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement conc (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials. With 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and1.00m inside dia. (Other than SAIL/TATA/RINL) |
| 42 | Supplying, fitting and fixing E.W.C. in white glazed vitreous chinaware of approved make complete in position with necessary bolts, nuts etc(a) With 'P' trap. |
| 43 | Supplying, fitting and fixing Closet seat of approved make with lid and C.P. hinges, rubber buffer and brass screws complete.(a) E.W.C.(ii) Plastic (hallow type) white |
| 44 | Supplying, fitting and fixing soap holder.(a) PTMT (Prayag or equivalent) |
| 45 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992(ii) Double Socketed 3 Meter Length (a) 75 mm |
| 46 | Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to AST MD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) (a) For Exposed Work PVC Pipes. 25 mm |
| 47 | Supplying, fitting and fixing bib cock or stop cock.(a) (i) Chromium plated Bib Cock short body (Equivalent to Code No. 511 & Model - Tropical / Sumthing Special of ESSCO or similar brand). |
| 48 | b) (i) Chromium plated Stop Cock (Equivalent to Code No. 513(A) & 513(B) & Model - Tropical / Sumthing Special of ESSCO or similar |
| 49 | Supplying, fitting and fixing 10 litre porcelain low-down cistern of approved make with either side or bottom inlet, side overflow, brackets complete with all internnal PVC fittings. White |
| 50 | Distribution wiring in 1.1 KV, 3x1.5 sq.mm. single core stranded 'FR' PVC insulated & unsheathed copper wire (Finolex, Havell’s) in19 mm bore, 3 mm thick polythene pipe complete with all accessories embedded in wall to LED surface mounted light /fan / ex-haust fan points with Modular type switch ( Legrand) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages . Average length- 8mtr. |
| 51 | Distribution wiring in 3x1.5 sq.mm. single core stranded 'FR' PVC insulated & unsheathed copper wire (Finolex, Havell’s, RR cable ) in 19 mm bore, 3 mm thick polythene pipe complete with all accessories embedded in wall to 240 V, 6A 3/5 pin plug point incl. S& F 240 V, 6A , 3/5 pin Modular type Socket & switch ( Legrand ) fixed on Modular GI switch board incl. earth continuity wire with Modular top cover plate flushed in wall incl. mending good damages to original finish. On board socket. |
| 52 | Fixing of 6/18 watt LED Panel/surface mounted light fittings on wall/ceiling by screws etc. . |
| 53 | S & F. 240V, 2 Modular socket type fan regulator (Step type) (Crabtree) on existing Modular GI switch board with top cover plate incl. making necy. connections etc. |
| 54 | Fixing of 240 volt, 1200 mm sweep ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 3x1.5 sq.mm. flexible copper wire. |
| 55 | Supply & Fixing 240 V, 2x6 A, 3 pin Modular type plug socket (Legrand ) with 6A Modular type switch, without plug top on GI / PVC Modular type switch board with Modular top cover plate on wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 56 | Supply & Fixing 240 V, 6/16 A, 3/5 pin Modular type plug socket (Legrand) with 16A Modular type switch, without plug top on GI Modular type switch board with top cover plate on wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 57 | Supply & fixing of 2 nos. 240 volt, 6 amp. Modular plug socket with 2 nos, 6 A modular switch & 1 no. 240 volt, 16 amp. Modular plug socket with switch in a single modular PVC/GI switch board ( Legrand) with top cover plate on wall incl. making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 58 | Supplying and fixing double door 4 way Vertical TPN MCB DB for 415 volt, 160amp. MCCB enclosure incomer with IP-42/43 protection, embeded on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Legrand). |
| 59 | Supplying and fixing 415 V, 125 amp, Four Pole MCCB of Breaking capacity 25kA /35kA with fixed thermal and fixed magnetic / adjus- table thermal and fixed magnetic setting in exis ting DBs / enclosure and necessary connection (Legrand). |
| 60 | Supplying and fixing 415 V, 63 A, TP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary con nection (Legrand). |
| 61 | Supplying and fixing 63 amp,6 way double door HTPN MCB DB with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment and painting for AC, SPNDB,single phase power point. (Make- Legrand ) |
| 62 | Supplying and fixing 415 V 63 A, 4 pole MCB on din rail of existing DBs and necessary connection.( Legrand) |
| 63 | S & F. 10-32 amp, 240V SPN MCB, ‘C’ curve on din rail of existing PDB & DB and necy. connection (Legrand). For HTPN MCB DB. & SPN MCB DB |
| 64 | Supplying and fixing double-door (2+8) SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.(Legrand) |
| 65 | S & F. 240 volt, 40 amp. DP MCB on din rail of existing DB and necessary connection ( Legrand). |
| 66 | S & F. 10-16 amp, 240V SPN MCB, ‘C’ curve on din rail of existing PDB & DB and necy. connection (Legrand). For HTPN MCB DB. & SPN MCB DB |
| 67 | S and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Finolex, Havell’s,RRcable) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required.a) 3x1.5 sq.mm for Switch board , 6 amp plug socketand . |
| 68 | b) 2x 2.5 +1x1.5 Sq mm Geyser and power point |
| 69 | c) 2x 4.0 +1x2.5 Sq mm for A.C. |
| 70 | c) 2x 6.0 +1x4 Sq mm for HTPN MCB DB to SPN MCB DB |
| 71 | Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket with 2 Module GI Modular type switch board with 2 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 72 | Supply & Fixing 240 V, 25 A, Modular type starter (Make- Legrand) with 25A Modular switch type DP MCB ('C' Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc |
| 73 | Laying of 3.5 core 25 sqmm cables after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth75 mm in floor/pavement/wall etc. and mending good the damages to original finish incl. removing the rubbish. |
| 74 | Laying of 3.5 core 50 sqmm cables after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth75 mm in floor/pavement/wall etc. and mending good the damages to original finish incl. removing the rubbish. |
| 75 | S&F of 3.5 core 25 Sq. mm compression type gland complete for following XLPE/PVC armoured cables. |
| 76 | S&F of 3.5 core 50 Sq. mm compression type gland complete for following XLPE/PVC armoured cables. |
| 77 | Finishing the end of 3.5 core 25 Sq. mm XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials. |
| 78 | Finishing the end of 3.5 core 50 Sq. mm XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials. |
| 79 | Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 40 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required. |
| 80 | Supply and fixing 240 volt AC/DC superior type multitune (min 10 nos tune) Call bell (Anchor or equivalent) with selector switch for single/Multi Tunes mode Batter operated on HW/PVC/ Bakelite board including S&F board and battery as required. |
| 81 | Supplying and fixing 2 way 240 volt MCB SS enclosure with IP-20/30 protection, powder coated MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment. Make- Legrand. |
| 82 | S & F. 240 volt, 20 amp. DP MCB on din rail of existing DB and necessary connection ( Legrand). For out door light fittings |
| 83 | Earthing with 80 mm dia. ISI medium GI pipe( TATA MEDIUM) 3.64 mm thick x6 mts. long and 1 no 65 mm x 6 mm x 8 mm galvanized ( hot Dip) steel dtrip ( 4 mtr long) 20 mm dia x 125 mm long galvanized bolt, double nut bolt s double washers including finishing both ends by making holes etc and supply and 80 mm dia GI pipe protection ( 6 mtr long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 7.3 mtr. ***Earth resistance should be below 1 ohm. |
| 84 | Supply and fixing of 415 volt 100 amp TPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc innc. S & F 3 nos. DIN type HRC as same rating . Make- L & T . Front handle |
| 85 | Connecting the equipments to earth busbar including S & F. 8 SWG copper solid wire on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages.Earth wire should be connected earth pit to all bushbar and earth bus bar to HTPN MCB DB & SPN MCB DB . |
| 86 | Connecting the equipments to earth busbar including S & F. 10 SWG copper solid wire on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages.Earth wire should be connected earth pit to all bushbar and earth bus bar to HTPN MCB DB & SPN MCB DB . |
| 87 | Supply of XLPE/ PVC Armoured Aluminium cable (GLOSTER, CRYSTOL, Havells). 1.1 kv grade, 3.5 core ,25 sq mm XLPE/PVC armoured aluminium cable, |
| 88 | Supply of XLPE/ PVC Armoured Aluminium cable (GLOSTER, CRYSTOL, Havells). 1.1 kv grade, 3.5 core ,50 sq mm XLPE/PVC armoured aluminium cable, |
| 89 | Supply of 230volt, 1200 mm sweep , AC ceiling Fan ( Orient - Summer King, SummerCool, Summer Breeze,) |
| 90 | Supply and fixing of 240 volt 250 mm modular PVC Exhaust fan , Make Havells - FHVVEDXOWH10 Ventil Air Dx. |
| 91 | Supply of 240 volt, 20 watt LED surface mounted light fittings Make- Philips, Model- SM251C LED20S- 6500 PSU WH. OR MAKE - Havells, Model - INTEGRANXTRDDLRSURD24WLED840S |
| 92 | Supply of 240 volt, 20 watt LED recessed panel light fittings Make- Philips, Model- DN296B LED20S-6500 PSE WH S2 |
| 93 | Supply of 240 volt, 6 watt LED surface mounted light fittings Make- Philips, Model- SM250C LED7S- 6500 PSU WH. OR MAKE - Havells, |
| 94 | Desmaintaling of existing electrification of proposed existing V.C. Bunglow and desmaintaling materials should be deposit to University store as per instruction of AE (El) |
| 95 | Supply, installation, testing and commissioning including supply and fixing of supporting bracket for out side unit of 2.0 ton ,3 star Split inverter AC incliding supply and fixing of mounting bracket . Make- Voltas, Model - 183 V CAZS.or equivalent Blue Star, HITACHI.[74990+1500+1500 =77990.00] |
| 96 | Add GST @18.00% from S.L. No- 01 to 95 |
| 97 | Add Cess @1.00% from S.L. No- 01 to 95 Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender