Tender For Providing Power Cable For Pillar Ac In Physiotherapy Room Near Honble Judges Library & Multilevel Parking At Punjab & Haryana High Court Sector 1, Chandigarh (Mtc. Of electrical installation In Nrb At Chandigarh)
Tender Overview
Project Description
Tender for Providing Power Cable For Pillar Ac In Physiotherapy Room Near Honble Judges Library & Multilevel Parking At Punjab & Haryana High Court Sector 1, Chandigarh (Mtc. Of electrical installation In Nrb At Chandigarh)
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 07-Aug-2026 | Tender Extend1 | Date | 10-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Supply and Laying of following PVC insulated and PVC sheathed Aluminium Cond. Arm. & Served cable working voltage upto 1100 Volt. grade of following size to be laid on surface/ in pipe/ trench. The job include the cost of making connections with suitable size of Al. Lugs/ thimbles, testing, commissioning etc. as required to the entire satisfaction of Engineer in Charge. |
| 2 | Size 70 Sq.mm 3.5 core PVC Al. Arm. Cond. Cable |
| 3 | Size 400 Sq.mm 3.5 core PVC Al. Arm. Cond. Cable |
| 4 | Shifting of existing switchgear after disconnection of cables/ wires etc. safely and reconnection the same after shifting at suitable /proposed place as per directions of EIC of work. The job includes all labour and petty material required to complete the job to the entire satisfaction of EIC of work. |
| 5 | DSR 11.1 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 6 | 3½ X 70 sq. mm (32mm) |
| 7 | 3½ X 400 sq. mm (82mm) |
| 8 | DSR 23.4 Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : |
| 9 | 300/400 sq. mm |
| 10 | Dismantling & re-installation of paver block including cement & concrete work as required to furnish similar existing look. The job includes all labour and petty material required to complete the job to the entire satisfaction of EIC of work. |
| 11 | DSR 15.16 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 100 mm DWC pipe in trench |
| 12 | 120 mm dia (OD-120 mm & ID-103 mm nominal) |
| 13 | DSR 2.2 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. |
| 14 | 400 A, 35 KA,TPMCCB |
| 15 | 200 A, 25 KA,TPMCCB |
| 16 | Supply & erection of Exhaust Fan (heavy duty motor with copper wound metallic body) following size complete with motor, metallic blades, double ball bearing with minimum power consumption, rigid frame with rubber mounting for silent operation, epoxy powder coating along with metallic louver to be installed in the existing opening including cost of carriage charges, making connection, testing, commissioning, and should be fixed inside the existing GI duct with suitable arrangements alongwith petty material required to complete the job to the entire satisfaction of Engineer-in-Charge. |
| 17 | Size 18” with louver Crompton/Havells/ Bajaj/ Orient/ Usha make |
| 18 | S/E of PVC sheathed copper wire following sizes to be drawn in existing pipes. The job includes making connections all labour and petty material required to complete the job to the entire satisfaction of the E.I.C. of the work. The copper wire should be of ISI marked only. |
| 19 | 2.5 sq mm x 3 core double sheathed |
| 20 | S/E of sheet metal 3 phase bus-bur chamber on existing surface with 4 nos. of bus-bar strips rating 250 amp. of require thickness as per ISI standards with detachable cover fitted with dust excluding gasket and secured with sufficient no. of cadmium plated iron screws and of given overall dimensions and to be fixed with GI bolts and nuts/rag bolts and nuts etc. complete with all accessories including connections with suitable size tin coated copper thimbles, bonding to the existing earth & painting etc as desired by the EIC. |
| 21 | Sheet metal bus-bar chamber 250 amp 415 V capacity with 4 aluminum strip 3 feet long |
| 22 | Supply & erection of MCCB enclosure to accommodate 200 amp rating MCCB with 16 GMS sheet. The enclosure should be sufficient size to accommodate to PVC aluminum armd. Cable connection upto 95 sq.mm 3 ½ core. The job includes all labour & petty material required to complete the job to the entire satisfaction of EIC. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
TodayBid Submission Deadline
Online submission via eProcurement portal.
TodayBid Opening Date
Technical bids will be opened and evaluated.
TodayTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender