Tender For Replacement Of Asbestos Sheets And Enclosure For Installation Of Sustainable Waste Transformation Unit At Ppc Moula-Ali, Hyderabad.

Issued by Statutory Bodies & Commissions/Committees · Hyderabad, Telangana
Tender Value
7.47 Lakhs
Estimated cost
Bid Submission
10 Aug 2026
6 days left
EMD
14956
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Hyderabad → Telangana
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Replacement Of Asbestos Sheets And Enclosure For Installation Of Sustainable Waste Transformation Unit At Ppc Moula-Ali, Hyderabad.

BOQ

Name of Work:- Replacement of asbestos sheets and enclosure for installation of Sustainable waste transformation Unit at PPC Moula-ali, Hyderabad.
Sl. No. Item Description
1Demolishing brick work in cement or lime mortar including required cost of scaffolding propping etc.,and stacking of serviceable materials and disposal of unserviceable material to out side of the campus as directed by Engineer-In-Charge.
2Demolishing of RCC work including stacking of steel bars and disposal of unserviceable material to out side of the campus as directed including cost of required scaffolding.
3Dismantling roofing including ridges, hips, valleys and gutters etc., and disposal of material outside the campus to approved muncipal grounds including all leads and lifts as directed by the Engineer-In-Charge. Asbestos Cement sheet
4Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. Including grooving to existing wall and place the sheet of minimum 50mm depth into the wall and good the same for avoiding leakages from wall side of the shed as directed by the Engineer-In-Charge.
5Steel work in built up tubular (round, square or rectangular hollow tubes, angles, flats etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes
6Supplying and fixing 10 Gauge weld mesh of size 50 mm x 50 mm openings and shall be fixid for floor/roof /vertical fixings for enclosures etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel paint primer. The weld mesh shall be fixed as per drawing and including all leads and lifts as directed by the Engineer-In-Charge.
7Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport and also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation, floorings etc. complete for all leads and lifts as directed by the Engineer-In-Charge.
8Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-lll) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
9Neat cement punning (cement slurry layer aplied over a freshly plastered surface)
10Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in: Cement Mortar 1:6 (1 cement : 6 coarse sand).
1115 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand)
12Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :One or more coats
13Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.25 mm nominal dia Pipes
14Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia Pipes
15Providing and fixing ball valve (brass) including provision of GI end pipe point for discharge of water etc., complete approved quality, High or low pressure as directed by the Engineer-In-Charge. 15mm dia
16Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15 mm nominal bore
17Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows(Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. Float glass panes 4 mm thick glass pane (weight not less than 10 kg/sqm).
18Cleaning the all types of tile surface and removing dirt, dust, bird dropping, grease, oil, algae, fungus, vegetable growth etc., including providing, applying and washing the surface with liquid Ammonia Chemical of 5% solution and other chemical cleaning agent as approved by Engineer-in-charge, of approved brand and manufacturer, with the help of required scrubbers and also cleaning with machine operated water jet mixed with desired quantity of fine silica where ever required, without causing any scratching/ damage to the stone surface and finally washing the surface with clean water with the help of pressure jet machine, complete in all respect, including taking all precautions to safe guard ventilators, windows, doors etc. by suitable covering so as to avoid any damage to the building/structure, including all leads and lifts as per direction of Engineer-in-charge.
19Providing & fixing White vitreous china water closet squatting pan (Indian type) along with “S” or “P” trap, angle cocok, connection pipe, flushtank etc., complete including dismantling of old WC pan and “S” or “P” trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material including malba, all complete as per the direction of Engineer-in charge.Orissa pattern W.C Pan of size 580x440 mm
20Earth work by mechinical/ manual means in rough excavation, banking excavated earth in layers not exceeding 20cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up in embankments for roads, flood banks, marginal banks and guide banks or filling up ground depressions, lead upto 50 m and for all lift
21Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
22Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.
23Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including scrapping and applying additional coats wherever required to achieve even shade and colour.
24Finishing walls with Acrylic Smooth exterior paint of required shade : including scrapping and applying additional coats wherever required to achieve even shade and colour. Old work (One or more coat applied @ 0.90 ltr/10 sqm)
25Providing, fixing and jointing/welding with Polypropylene material 110mm outer diameter Polypropylene pipes including necessary bends/tees/ y, hardware etc., and and making of holes with good the same after fixing etc., complete with all leads and lifts as directed by Engineer-in-charge.
26Dismantling of Existing sub panels : The work includes complete disconnection of panels and disconnection of existing connected cables of different sizes , Wires, Earth Wires from the swithcgears.The work also includes dismantling of angle iron frame work ,CRCA/MS sheet works , welding, cutting removing of unused cables from panels including all related chipping / minor civil works for making good complete and transporting the dismantled material over lead distance of about 1000Mtrs from the site to Departmental stores as directed by as the engineer incharge ( Each panel generally Consists of MCCBs as I/C and MCB/MCCB/ Isolators as O/G or Busbars with connected cables ) (Temparary power supply should be provided at the affected areas at time of Dismantling )
27Supply of 3.5Cx50Sq.mm aluminium armoured XLPE insulated under ground cable as per IS standards etc., as required and as directed by the engineer in charge.
28Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 50 sq. mm (35mm)
29Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 35 sq. mm and upto 95 sq. mm
30Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
31Group A
32Group B
33Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (Make:Sudhakar)
34Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. (Make: Finolex)
35(i) 3 x 2.5 sq.mm
36(ii) 3 x 4 sq. mm
37(iii) 5 x 4 sq. mm
38Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
39(i) 5/6 A switch
40(ii) 15/16 A switch
41(iii) 3pin 5/6 A socket outlet
42(iv)6 pin 15/16 A socket outlet
43Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.
44(i) 6 Module (200mmX75mm)
45(ii) 12 Module (200mmX150mm)
46Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
47Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note: Vertical type MCB TPDB is normally usedwhere 3 phase outlets are required.)
48(i) 8 way (4 + 24), Double door
49(ii) 12 way (4 + 36), Double door
50Supply and fixing of 63 A, TP MCB in existing VTPN DB Make: L&T/Legrand
51Supply and fixing of 125 A, 25kA MCCB in existing VTPN DB Make: L&T/Legrand
52Supplying & fixing of TP&N sheet steel enclosure MCB DB in recess/surface including painting, earthing etc., as required.Make: Legrand
53Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing andcommissioning etc. as required. Make:Legrand
54(i) Single pole
55(ii) Double pole
56(iii) Triple pole and neutral
57Supply of single phase, 230 V, 50Hz, 450mm sweep, 900 RPM Heavy duty exhaust fan complete set as directed by Engineer incharge.Make:Crompton/Havells/Almonard
58Installation,Testing and Commissioning of exhaust fan in the existingopening, including making good the damage, connection, testing, commissioning etc. asrequired..Upto 450 mm sweeep
59Extra for fixing the louvers/ shutters complete with frame for aexhaust fan of all sizes.
60Supply and fixing of 50W LED High Bay lights with required length of Chain and with necessory accessories.
61Supply of 450MM Pedestal Fan - High Speed Stand Fan With 3 Speed Settings & Cast Aluminum Metal Blades - 90 Degree Oscillating Pedestal Fan With Adjustable Fan Height & Tilt Make: Almonard.
62Supply and fixing of 50W LED floodlight outdoor fixture completely with all accessories as directed by Engineer incharge. Make: Philips /Crompton
63Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having lockingarrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required.
64Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
65Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56771485
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 7.47 Lakhs
LAST DATE 10-08-2026
Authority
Authority Name Council Of Scientific And Industrial Research
Work Description Tender for Replacement Of Asbestos Sheets And Enclosure For Installation Of Sustainable Waste Transformation Unit At Ppc Moula-Ali, Hyderabad.
Basic Detail
Tender No ESD/L-498/2026
Bidding Type Tender
Location
City Hyderabad
State Telangana
Key Dates
Publish Date 31 Jul 2026
Submission Date 10 Aug 2026
Open Date 12 Aug 2026
Finance
Tender Value 7.47 Lakhs
Tender Fee 500
EMD 14956
Exemption Available
Document List
5fe02e06-db9b-4aaf-ac04-7ebc0a96cdd2.html
BOQ_334046.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 31, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 10, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Aug 12, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
html

5fe02e06-db9b-4aaf-ac04-7ebc0a96cdd2.html

xls

BOQ_334046.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender